Download - MAXRaft Brochure

Transcript

• Healthy,comfortablehomes.

• Reducedheatinganddoctors’bills.

• FullyinsulatedwithaverageR-valueofapproximatelyR4.5

• Minimalthermalbridging.

• Minimalsiteworksleadtoreducedcosts.

• Lesstimeonsite

• Seismicallystrong.

• Sitespecificengineering.

• Capableonsoilswithaminimumallowablebearingcapacityof75kPa.

• UPto30%-40%efficiencygainsforunderfloorheating

“Onastandardflatsection220m2house,wecanexcavateonaMonday,andbyFriday,beplacingtheconcrete,readyforframestobeerectedonMonday–oneweekturnaround.MAXRaft®issimplythequickestandmostefficientbuildingmethodforaconcreteflooronthemarkettoday,letaloneitsexcellentthermalefficiencywhichisitsmainadvantage.Ibelievethisisthewayofthefuture.”- David Reid Homes

Phone:0800MAXRaft(629723)Christchurch:027MAXRaft(6297238)Email:[email protected]:[email protected]

“HavingmadethedecisiontoinstallunderfloorheatinginmynewhomeIknewfrompreviousexperiencethatIwantedafullyinsulatedfoundationtopreventheatloss.AfterabitofsearchingaroundIcameacrossMAXRaftandknewstraightawayitwasexactlywhatIwaslookingfor.CombiningMAXRaftwithaheatedslabhasgivenmeawarmhomeineveryroomallyearroundandthebestthingismypowerbillsarealotlowerthanmanypeopleIknow.Duringwinterthecostofmyhydronicheatinghasaveraged60.8cperm2permonth!WhenIbuildmynexthomeIwilldefinitelybeusingafullyinsulatedslabagain”- Terry Robb

“InourexperienceMAXRaftisoneofthemostefficientwaysofpreppingaconcreteslabthananyothersystem.ThereislimitedbracingandboxingrequiredastheMAXRaftisprefabricatedinthefactoryanddeliveredontositereadytobeinstalled.ItsratingisaR4.5whichmakesanybuildingusingitextremelywellinsulated.Highlyrecommended.”- Evolution Homes

BENEFITS TESTIMONIALS

CONTACT US

TM

Know your home

MAXRaft® is changing the way people think about foundations. Build Better today for a better tomorrow.

Witheverydesign,wearehelpingpeopleliveinwarmer,healthier,moreefficienthomes.

eboss

• ExcavatebuildingsitetoappropriatelevelinlinewithGeotechandEngineer’srecommendations,compactingandbackfillingasnecessary.

• Levelthesiteusingalayeroffinescreed,putupboxingaroundperimeter

• Laydampproofmembraneoverentirebuildingplatform,ensurethereisenoughmaterialtoextend100mmoutsidethefoundation.Ensureunderfloordrainsaretapedup

• ReceivedeliveryofMAXRaftinsulation.Placepre-cutMAXRaftinsulationinlinewithPanelplan,followPanelplandirectlytoensurethatloadbearingthickeningsandthermalbreaksareincorrectplace

• Placereinforcingsteel(designedinlinewithengineer’sspecifications)inperimeterfootingwells.Underfloorheatingcanbeinstalledatthisstage,dependingoninstaller’srequirements.

• PlacereinforcingmeshontopoftheMAXRaft.Tiemeshtoreinforcingaroundperimeterandbeneathloadbearingwalls.

• Placingfinishedconcretetospecifications.

• EnjoythewarmthandcomfortcreatedwithaMAXRaftfloor.

CONSTRUCTION PROCESS

D1 © - 01

SheetTitle

Drawn

Revision

Scale @ A4

ProjectNumber.

Date

DrawingNumber.

Project

MAXRaft© Detailswww.maxraft.co.nzCWL 20/61:10

0D1

MAXRaft 90x45 Frame Foundation

Note:Prop wall while backfilling untilsuspended floor is poured and cured.

100

250

1200

200

Polyblock waterproofedand back filled as perarchitects details

MAXRaft on DPM, sandblinding and solidcompaction

Polyblock braced as permanufacturers details

Reinforcing as perEngineers details

D5 MAXRaft© - RetainingWall Foundation01

280

100

MAXSpan

SheetTitle

Drawn

Revision

Scale @ A4

ProjectNumber.

Date

DrawingNumber.

Project

MAXRaft© Detailswww.maxraft.co.nzCWL 20 / 61:20

0D5

MAXRaft Retaining Foundation

D4

Concrete & reinforcing as per engineers details

Supercoat tanking system asper manufacturers details

Cladding by others.

NOTE:150mm min clearance fromslab level to exterior paving,225mm min clearance fromslab level to unpaved groundto E2/AS1.

300

25

Solid compaction1000mm pastfoundation line

MAXWaffleRaft© - Timber Framewith Lightweight cladding01

Timber framed wall with bottom plate fixing toMaxRaft Specification

100

170

50

320

50

MaxWaffleRaft

Compacted hard fill orsimilar by others, min200 kPa Ultimate bearingstrength at formation.Refer to MIBE (2012)guidelines for building inTC2 locations.

1100 120

She

etTi

tleD

raw

n

Rev

isio

n

Sca

le @

A4

Pro

ject

Num

ber.

Dat

e

Dra

win

gN

umbe

r.

Pro

ject

MA

XR

aft©

Det

ails

ww

w.m

axra

ft.co

.nz

CW

L20

/ 6

N T

S

0D4

MA

XR

aft W

affle

Fou

ndat

ion

01D2 © -

SheetTitle

Drawn

Revision

Scale @ A4

ProjectNumber.

Date

DrawingNumber.

Project

MAXRaft© Detailswww.maxraft.co.nzCWL 20 / 61:10

0D2

MAXRaft Loadbearing Foundation

Ourperimeterfootingsaredesignedtomaintainheatintheslabattheexactpointwhereupto80%ofheatlossintheslaboccurs.Thisensuresthatthefloor/walljunctureremainswarm,dryandmouldfree,increasingcomfortandloweringpossiblehealthissues.

Thermalbridgefreeconstructionisessentialforperimeterfoundationstoensurethereisnocondensationriskandoptimalthermalcomfort.

Aconventionalwaffleslabfloorhasmanythermalbridgesespeciallyaroundtheperimeter.

AcomparisonstudybetweentheperimeterfoundationofatraditionalwaffleslabandafullyInsulatedfootingassumingstandardtimberwallconstruction.

CopyrighteZEDLtd

• MAXSpandeliversthebenefitsofMAXRaft®totheupperlevelsofyourhome.

• Suitableforuseonmulti-storeybuildings,abovebasementsoroninclinesites,MAXSpanwillallowyoutouseaconcretefloorabovethefoundation.

MAXRaft®offersacontinuouslayerofperimeterinsulation.Thishasadramaticeffectonthesurfacetemperatureattheflooredge.

Ouriso-thermalanalysismakesiteasytoseethedifferenceinsurfacetemperature.

• MAXRaftcanbeusedinconjunctionwithretainingwallsandsoisnotlimitedtouseonjustflatsites.Ourengineerscanprovidedesignsthatwillallowyoutomaintainafullyinsulatedslabwhilealsoprovidingthestrengthneededtoprotectyourhomefromgroundaroundit

MAXWaffleRaftisdesignedtocomplywithDBHguidelinesforbuildingsonTC2landcategoriesandthosesitesongroundof‹100kPa,whilestillmaintainingathermalenvelopearoundyourhome.

Ourloadbearingthickeningsaredesignedsupportloadbearingwallswithinyourhomewhilemaintainingacompletethermalenvelopearoundyourfoundation.

NZS3604/TC1 MAXRaft Perimeter Footing

Traditional Waffle Slab

MAXSpan

MAXRaft® Slab

Retaining walls

MAXWaffleRaft / TC2 Solution

Internal Thickenings / Tie Beams


Top Related