maxraft brochure

2
Healthy, comfortable homes. Reduced heating and doctors’ bills. Fully insulated with average R-value of approximately R4.5 Minimal thermal bridging. Minimal site works lead to reduced costs. Less time on site Seismically strong. Site specific engineering. Capable on soils with a minimum allowable bearing capacity of 75kPa. UP to 30%-40% efficiency gains for underfloor heating “On a standard flat section 220m2 house, we can excavate on a Monday, and by Friday, be placing the concrete, ready for frames to be erected on Monday – one week turnaround. MAXRaft® is simply the quickest and most efficient building method for a concrete floor on the market today, let alone its excellent thermal efficiency which is its main advantage. I believe this is the way of the future.” - David Reid Homes Phone: 0800 MAXRaft (629 723) Christchurch: 027 MAXRaft (629 7238) Email: [email protected] Christchurch: [email protected] WWW.MAXRAFT.CO.NZ “Having made the decision to install underfloor heating in my new home I knew from previous experience that I wanted a fully insulated foundation to prevent heat loss. After a bit of searching around I came across MAXRaft and knew straight away it was exactly what I was looking for. Combining MAXRaft with a heated slab has given me a warm home in every room all year round and the best thing is my power bills are a lot lower than many people I know. During winter the cost of my hydronic heating has averaged 60.8c per m2 per month! When I build my next home I will definitely be using a fully insulated slab again” - Terry Robb “In our experience MAXRaft is one of the most efficient ways of prepping a concrete slab than any other system. There is limited bracing and boxing required as the MAXRaft is prefabricated in the factory and delivered onto site ready to be installed. Its rating is a R4.5 which makes any building using it extremely well insulated. Highly recommended.” - Evolution Homes BENEFITS TESTIMONIALS CONTACT US TM Know your home MAXRaft® is changing the way people think about foundations. Build Better today for a better tomorrow. With every design, we are helping people live in warmer, healthier, more efficient homes. eboss

Upload: henry-edney

Post on 11-Aug-2015

54 views

Category:

Documents


3 download

TRANSCRIPT

• Healthy,comfortablehomes.

• Reducedheatinganddoctors’bills.

• FullyinsulatedwithaverageR-valueofapproximatelyR4.5

• Minimalthermalbridging.

• Minimalsiteworksleadtoreducedcosts.

• Lesstimeonsite

• Seismicallystrong.

• Sitespecificengineering.

• Capableonsoilswithaminimumallowablebearingcapacityof75kPa.

• UPto30%-40%efficiencygainsforunderfloorheating

“Onastandardflatsection220m2house,wecanexcavateonaMonday,andbyFriday,beplacingtheconcrete,readyforframestobeerectedonMonday–oneweekturnaround.MAXRaft®issimplythequickestandmostefficientbuildingmethodforaconcreteflooronthemarkettoday,letaloneitsexcellentthermalefficiencywhichisitsmainadvantage.Ibelievethisisthewayofthefuture.”- David Reid Homes

Phone:0800MAXRaft(629723)Christchurch:027MAXRaft(6297238)Email:[email protected]:[email protected]

“HavingmadethedecisiontoinstallunderfloorheatinginmynewhomeIknewfrompreviousexperiencethatIwantedafullyinsulatedfoundationtopreventheatloss.AfterabitofsearchingaroundIcameacrossMAXRaftandknewstraightawayitwasexactlywhatIwaslookingfor.CombiningMAXRaftwithaheatedslabhasgivenmeawarmhomeineveryroomallyearroundandthebestthingismypowerbillsarealotlowerthanmanypeopleIknow.Duringwinterthecostofmyhydronicheatinghasaveraged60.8cperm2permonth!WhenIbuildmynexthomeIwilldefinitelybeusingafullyinsulatedslabagain”- Terry Robb

“InourexperienceMAXRaftisoneofthemostefficientwaysofpreppingaconcreteslabthananyothersystem.ThereislimitedbracingandboxingrequiredastheMAXRaftisprefabricatedinthefactoryanddeliveredontositereadytobeinstalled.ItsratingisaR4.5whichmakesanybuildingusingitextremelywellinsulated.Highlyrecommended.”- Evolution Homes

BENEFITS TESTIMONIALS

CONTACT US

TM

Know your home

MAXRaft® is changing the way people think about foundations. Build Better today for a better tomorrow.

Witheverydesign,wearehelpingpeopleliveinwarmer,healthier,moreefficienthomes.

eboss

• ExcavatebuildingsitetoappropriatelevelinlinewithGeotechandEngineer’srecommendations,compactingandbackfillingasnecessary.

• Levelthesiteusingalayeroffinescreed,putupboxingaroundperimeter

• Laydampproofmembraneoverentirebuildingplatform,ensurethereisenoughmaterialtoextend100mmoutsidethefoundation.Ensureunderfloordrainsaretapedup

• ReceivedeliveryofMAXRaftinsulation.Placepre-cutMAXRaftinsulationinlinewithPanelplan,followPanelplandirectlytoensurethatloadbearingthickeningsandthermalbreaksareincorrectplace

• Placereinforcingsteel(designedinlinewithengineer’sspecifications)inperimeterfootingwells.Underfloorheatingcanbeinstalledatthisstage,dependingoninstaller’srequirements.

• PlacereinforcingmeshontopoftheMAXRaft.Tiemeshtoreinforcingaroundperimeterandbeneathloadbearingwalls.

• Placingfinishedconcretetospecifications.

• EnjoythewarmthandcomfortcreatedwithaMAXRaftfloor.

CONSTRUCTION PROCESS

D1 © - 01

SheetTitle

Drawn

Revision

Scale @ A4

ProjectNumber.

Date

DrawingNumber.

Project

MAXRaft© Detailswww.maxraft.co.nzCWL 20/61:10

0D1

MAXRaft 90x45 Frame Foundation

Note:Prop wall while backfilling untilsuspended floor is poured and cured.

100

250

1200

200

Polyblock waterproofedand back filled as perarchitects details

MAXRaft on DPM, sandblinding and solidcompaction

Polyblock braced as permanufacturers details

Reinforcing as perEngineers details

D5 MAXRaft© - RetainingWall Foundation01

280

100

MAXSpan

SheetTitle

Drawn

Revision

Scale @ A4

ProjectNumber.

Date

DrawingNumber.

Project

MAXRaft© Detailswww.maxraft.co.nzCWL 20 / 61:20

0D5

MAXRaft Retaining Foundation

D4

Concrete & reinforcing as per engineers details

Supercoat tanking system asper manufacturers details

Cladding by others.

NOTE:150mm min clearance fromslab level to exterior paving,225mm min clearance fromslab level to unpaved groundto E2/AS1.

300

25

Solid compaction1000mm pastfoundation line

MAXWaffleRaft© - Timber Framewith Lightweight cladding01

Timber framed wall with bottom plate fixing toMaxRaft Specification

100

170

50

320

50

MaxWaffleRaft

Compacted hard fill orsimilar by others, min200 kPa Ultimate bearingstrength at formation.Refer to MIBE (2012)guidelines for building inTC2 locations.

1100 120

She

etTi

tleD

raw

n

Rev

isio

n

Sca

le @

A4

Pro

ject

Num

ber.

Dat

e

Dra

win

gN

umbe

r.

Pro

ject

MA

XR

aft©

Det

ails

ww

w.m

axra

ft.co

.nz

CW

L20

/ 6

N T

S

0D4

MA

XR

aft W

affle

Fou

ndat

ion

01D2 © -

SheetTitle

Drawn

Revision

Scale @ A4

ProjectNumber.

Date

DrawingNumber.

Project

MAXRaft© Detailswww.maxraft.co.nzCWL 20 / 61:10

0D2

MAXRaft Loadbearing Foundation

Ourperimeterfootingsaredesignedtomaintainheatintheslabattheexactpointwhereupto80%ofheatlossintheslaboccurs.Thisensuresthatthefloor/walljunctureremainswarm,dryandmouldfree,increasingcomfortandloweringpossiblehealthissues.

Thermalbridgefreeconstructionisessentialforperimeterfoundationstoensurethereisnocondensationriskandoptimalthermalcomfort.

Aconventionalwaffleslabfloorhasmanythermalbridgesespeciallyaroundtheperimeter.

AcomparisonstudybetweentheperimeterfoundationofatraditionalwaffleslabandafullyInsulatedfootingassumingstandardtimberwallconstruction.

CopyrighteZEDLtd

• MAXSpandeliversthebenefitsofMAXRaft®totheupperlevelsofyourhome.

• Suitableforuseonmulti-storeybuildings,abovebasementsoroninclinesites,MAXSpanwillallowyoutouseaconcretefloorabovethefoundation.

MAXRaft®offersacontinuouslayerofperimeterinsulation.Thishasadramaticeffectonthesurfacetemperatureattheflooredge.

Ouriso-thermalanalysismakesiteasytoseethedifferenceinsurfacetemperature.

• MAXRaftcanbeusedinconjunctionwithretainingwallsandsoisnotlimitedtouseonjustflatsites.Ourengineerscanprovidedesignsthatwillallowyoutomaintainafullyinsulatedslabwhilealsoprovidingthestrengthneededtoprotectyourhomefromgroundaroundit

MAXWaffleRaftisdesignedtocomplywithDBHguidelinesforbuildingsonTC2landcategoriesandthosesitesongroundof‹100kPa,whilestillmaintainingathermalenvelopearoundyourhome.

Ourloadbearingthickeningsaredesignedsupportloadbearingwallswithinyourhomewhilemaintainingacompletethermalenvelopearoundyourfoundation.

NZS3604/TC1 MAXRaft Perimeter Footing

Traditional Waffle Slab

MAXSpan

MAXRaft® Slab

Retaining walls

MAXWaffleRaft / TC2 Solution

Internal Thickenings / Tie Beams