Download - Minilog Series of Data Loggers
![Page 1: Minilog Series of Data Loggers](https://reader038.vdocument.in/reader038/viewer/2022110101/56812b26550346895d8f2d04/html5/thumbnails/1.jpg)
Minilog Series of Data LoggersML1 Digital Input (Rainfall and Flow)ML420 4-20mA Input (Water Level)ML1-420 Digital Input + 4-20mA Input + Temp + BV
By : Steve LaurenceHydrological Services P/L
![Page 2: Minilog Series of Data Loggers](https://reader038.vdocument.in/reader038/viewer/2022110101/56812b26550346895d8f2d04/html5/thumbnails/2.jpg)
Features :Small SizeLow CostRS232Easy to configure via asciiOnboard help (?)ML1 – 3.6V AA lithium battery
ML420 – 3.6V ½ AA lithium batteryML1-420 - 1.5V AA alkaline OR 3.6V AA lithium
![Page 3: Minilog Series of Data Loggers](https://reader038.vdocument.in/reader038/viewer/2022110101/56812b26550346895d8f2d04/html5/thumbnails/3.jpg)
ML1 Minilog• Event logging – each bucket tip creates an event in the data
memory• 100,000 events can be logged• Operates on internal lithium battery only• Basic Commands :
? HelpST Display the statusINC Bucket Increment 0.2/01 (0.2mm bucket 01 event)DUR Dump Record (+ Dump Search)T TimeD Date
![Page 4: Minilog Series of Data Loggers](https://reader038.vdocument.in/reader038/viewer/2022110101/56812b26550346895d8f2d04/html5/thumbnails/4.jpg)
ML420 Minilog• Timed logging – set a schedule of when you require
measurements to be taken – eg. Every 15 mins• 50,000 measurements can be logged• Requires external 12V battery to power 4-20mA Sensor• Basic Commands :
? HelpRvHR River Height Ref (Offset) eg. 0.000 (4mA level)TxR Transducer Range eg. 30.000TxI Transducer Interval eg. 015/05 (15min log 5 sec warmup)WL Water Level nowDURV Dump River Data (+ Dump search)T TimeD Date
![Page 5: Minilog Series of Data Loggers](https://reader038.vdocument.in/reader038/viewer/2022110101/56812b26550346895d8f2d04/html5/thumbnails/5.jpg)
ML1-420 Minilog• Internal 3.6V lithium OR 1.5V Alkaline• Event logging of Rainfall + schedule logging of 4-20mA
+ TempC + Internal battery + External battery• 400,000 Events / Measurements can be logged• Requires an external 12V to power 4-20mA sensor • Basic Commands :
? HelpDUR Dump RainDURV Dump RiverDUBVI Dump BattV InternalDUBVE Dump BattV ExternalDUTMP Dump TemperatureDUALL Dump All
![Page 6: Minilog Series of Data Loggers](https://reader038.vdocument.in/reader038/viewer/2022110101/56812b26550346895d8f2d04/html5/thumbnails/6.jpg)
WinComLog :
More than a terminal program(Can also be an SDI-12 terminal to HS products)
Can custom configure / program 72 buttonsSetup scheduling / collection of data via dialupPlot / view collected dataDownload new firmware into products
![Page 7: Minilog Series of Data Loggers](https://reader038.vdocument.in/reader038/viewer/2022110101/56812b26550346895d8f2d04/html5/thumbnails/7.jpg)
WinComLog :
![Page 8: Minilog Series of Data Loggers](https://reader038.vdocument.in/reader038/viewer/2022110101/56812b26550346895d8f2d04/html5/thumbnails/8.jpg)
WinComLog :