minilog series of data loggers

8
Minilog Series of Data Loggers ML1 Digital Input (Rainfall and Flow) ML420 4-20mA Input (Water Level) ML1-420 Digital Input + 4-20mA Input + Temp + BV By : Steve Laurence Hydrological Services P/L

Upload: cullen-hutchinson

Post on 30-Dec-2015

41 views

Category:

Documents


4 download

DESCRIPTION

Minilog Series of Data Loggers. ML1Digital Input (Rainfall and Flow) ML4204-20mA Input (Water Level) ML1-420Digital Input + 4-20mA Input + Temp + BV. By : Steve Laurence Hydrological Services P/L. Features :. Small Size Low Cost RS232 Easy to configure via ascii Onboard help (?) - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Minilog Series of Data Loggers

Minilog Series of Data LoggersML1 Digital Input (Rainfall and Flow)ML420 4-20mA Input (Water Level)ML1-420 Digital Input + 4-20mA Input + Temp + BV

By : Steve LaurenceHydrological Services P/L

Page 2: Minilog Series of Data Loggers

Features :Small SizeLow CostRS232Easy to configure via asciiOnboard help (?)ML1 – 3.6V AA lithium battery

ML420 – 3.6V ½ AA lithium batteryML1-420 - 1.5V AA alkaline OR 3.6V AA lithium

Page 3: Minilog Series of Data Loggers

ML1 Minilog• Event logging – each bucket tip creates an event in the data

memory• 100,000 events can be logged• Operates on internal lithium battery only• Basic Commands :

? HelpST Display the statusINC Bucket Increment 0.2/01 (0.2mm bucket 01 event)DUR Dump Record (+ Dump Search)T TimeD Date

Page 4: Minilog Series of Data Loggers

ML420 Minilog• Timed logging – set a schedule of when you require

measurements to be taken – eg. Every 15 mins• 50,000 measurements can be logged• Requires external 12V battery to power 4-20mA Sensor• Basic Commands :

? HelpRvHR River Height Ref (Offset) eg. 0.000 (4mA level)TxR Transducer Range eg. 30.000TxI Transducer Interval eg. 015/05 (15min log 5 sec warmup)WL Water Level nowDURV Dump River Data (+ Dump search)T TimeD Date

Page 5: Minilog Series of Data Loggers

ML1-420 Minilog• Internal 3.6V lithium OR 1.5V Alkaline• Event logging of Rainfall + schedule logging of 4-20mA

+ TempC + Internal battery + External battery• 400,000 Events / Measurements can be logged• Requires an external 12V to power 4-20mA sensor • Basic Commands :

? HelpDUR Dump RainDURV Dump RiverDUBVI Dump BattV InternalDUBVE Dump BattV ExternalDUTMP Dump TemperatureDUALL Dump All

Page 6: Minilog Series of Data Loggers

WinComLog :

More than a terminal program(Can also be an SDI-12 terminal to HS products)

Can custom configure / program 72 buttonsSetup scheduling / collection of data via dialupPlot / view collected dataDownload new firmware into products

Page 7: Minilog Series of Data Loggers

WinComLog :

Page 8: Minilog Series of Data Loggers

WinComLog :