Download - NodeB Fault Management
-
Fault ManagementContents1 Fault Management1.1 NodeB Alarm Reference1.1.1 NodeB Alarm List1.1.2 ALM-25600 Monitoring Device Maintenance Link Failure1.1.3 ALM-25601 Monitoring Device Hardware Fault1.1.4 ALM-25602 Sensor Failure1.1.5 ALM-25620 Monitoring Device Power Supply Problem1.1.6 ALM-25621 Power Supply DC Output Out of Range1.1.7 ALM-25622 Mains Input Out of Range1.1.8 ALM-25623 Load Disconnected1.1.9 ALM-25624 Battery Power Unavailable1.1.10 ALM-25625 Battery Current Out of Range1.1.11 ALM-25626 Power Module Abnormal1.1.12 ALM-25628 AC Surge Protector Fault1.1.13 ALM-25630 Power Module and Monitoring Module Communication Failure1.1.14 ALM-25631 Load Fuse Broken1.1.15 ALM-25632 Battery Cabin Heater Fault1.1.16 ALM-25633 PMU Internal Interface Communication Failure1.1.17 ALM-25634 Battery Not In Position1.1.18 ALM-25636 Loss of Power Supply Redundancy1.1.19 ALM-25650 Ambient Temperature Unacceptable1.1.20 ALM-25651 Ambient Humidity Unacceptable1.1.21 ALM-25652 Cabinet Temperature Unacceptable1.1.22 ALM-25653 Cabinet Humidity Unacceptable1.1.23 ALM-25654 Battery Temperature Unacceptable1.1.24 ALM-25655 Cabinet Air Outlet Temperature Unacceptable1.1.25 ALM-25656 Cabinet Air Inlet Temperature Unacceptable1.1.26 ALM-25657 TEC Cooler Fault1.1.27 ALM-25670 Water Alarm1.1.28 ALM-25671 Smoke Alarm1.1.29 ALM-25672 Burglar Alarm1.1.30 ALM-25673 Fan Stalled1.1.31 ALM-25695 Diesel Generator Fault1.1.32 ALM-25696 Diesel Generator Low Fuel1.1.33 ALM-25697 Diesel Generator Startup Failure1.1.34 ALM-25710 Loss of Solar Array1.1.35 ALM-25711 Solar Array Fault1.1.36 ALM-25713 Solar Controller Temperature Unacceptable1.1.37 ALM-25719 CCU Topology and Configuration Mismatch1.1.38 ALM-25720 Inter-CCU Port Connection Error1.1.39 ALM-25721 CCU-BBU Communication Failure1.1.40 ALM-25800 E1/T1 Loss of Signal1.1.41 ALM-25801 E1/T1 Alarm Indication Signal1.1.42 ALM-25802 E1/T1 Remote Alarm Indication Signal1.1.43 ALM-25803 E1/T1 Loss of Frame Alignment1.1.44 ALM-25804 E1/T1 Loss of Multiframe Alignment1.1.45 ALM-25805 E1/T1 Excessive Slip Frames1.1.46 ALM-25806 E1/T1 Excessive Bit Error Rate
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
1 de 526 13/11/2012 9:15
-
1.1.47 ALM-25807 E1/T1 Loopback1.1.48 ALM-25820 Fractional ATM Link Loss of Cell Delineation1.1.49 ALM-25821 IMA/ATM Link Loss of Cell Delineation1.1.50 ALM-25823 IMA Link Loss of Frame1.1.51 ALM-25824 IMA Link Out of Delay Synchronization1.1.52 ALM-25825 IMA Link Remote Failure Indication1.1.53 ALM-25826 IMA Link RX Fault1.1.54 ALM-25827 IMA Link TX Unusable at Far End1.1.55 ALM-25828 IMA Link RX Unusable at Far End1.1.56 ALM-25829 IMA Group Startup at Far End1.1.57 ALM-25830 IMA Group Configuration Aborted1.1.58 ALM-25831 IMA Group Configuration Aborted at Far End1.1.59 ALM-25832 IMA Group Activated Links Insufficient1.1.60 ALM-25833 IMA Group Activated Links Insufficient at Far End1.1.61 ALM-25834 IMA Group Blocked at Far End1.1.62 ALM-25835 NCP Fault1.1.63 ALM-25836 CCP Fault1.1.64 ALM-25837 ALCAP Fault1.1.65 ALM-25838 AAL2 Path Fault1.1.66 ALM-25840 SAAL Link Fault1.1.67 ALM-25841 SAAL Link Congestion1.1.68 ALM-25860 PPP/MLPPP Link Fault1.1.69 ALM-25861 MLPPP Group Fault1.1.70 ALM-25862 MLPPP Group Excessive Packet Loss Rate1.1.71 ALM-25863 PPP Link Excessive Frame Error Rate1.1.72 ALM-25879 Ethernet Port Broadcast Packets Exceeding Alarm1.1.73 ALM-25880 Ethernet Link Fault1.1.74 ALM-25881 MAC Excessive Frame Error Rate1.1.75 ALM-25882 ETHOAM 3AH Discovery Failure1.1.76 ALM-25883 ETHOAM 3AH Local Fault1.1.77 ALM-25884 ETHOAM 3AH Remote Fault1.1.78 ALM-25885 IP Address Conflict1.1.79 ALM-25886 IP Path Fault1.1.80 ALM-25887 Ethernet Trunk Link Fault1.1.81 ALM-25888 SCTP Link Fault1.1.82 ALM-25889 SCTP Link Congestion1.1.83 ALM-25891 IKE Negotiation Failure1.1.84 ALM-25894 ETHOAM 3AH Remote Loopback1.1.85 ALM-25895 Ethernet Trunk Group Fault1.1.86 ALM-25896 IP Remote Loopback1.1.87 ALM-25897 IP Excessive Frame Error Rate1.1.88 ALM-25898 IP Path Excessive Packet Loss Rate1.1.89 ALM-25899 BFD Session Fault1.1.90 ALM-25900 IP PM Activation Failure1.1.91 ALM-25901 Remote Maintenance Link Failure1.1.92 ALM-25902 Remote Maintenance Link Running Data and Configuration Mismatch1.1.93 ALM-25920 SDH/SONET Loss of Frame Alignment1.1.94 ALM-25921 SDH/SONET Loss of Frame1.1.95 ALM-25922 SDH/SONET Loss of Signal1.1.96 ALM-25923 SDH/SONET AU Loss of Pointer1.1.97 ALM-25924 SDH/SONET MS Alarm Indication Signal1.1.98 ALM-25925 SDH/SONET MS Remote Defect Indication1.1.99 ALM-25926 SDH/SONET Loss of Cell Delineation1.1.100 ALM-25927 SDH/SONET Optical Port Loopback1.1.101 ALM-25928 SDH/SONET RS Trace Identifier Mismatch
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
2 de 526 13/11/2012 9:15
-
1.1.102 ALM-25929 SDH/SONET RS Excessive Bit Error Rate1.1.103 ALM-25930 SDH/SONET MS Excessive Bit Error Rate1.1.104 ALM-25931 SDH/SONET MS Signal Degraded1.1.105 ALM-25932 SDH/SONET MS Remote Error Indication1.1.106 ALM-25933 SDH/SONET AU Alarm Indication Signal1.1.107 ALM-25934 SDH/SONET HP Unequipped Defect1.1.108 ALM-25935 SDH/SONET HP Signal Label Mismatch1.1.109 ALM-25936 SDH/SONET HP Trace Identifier Mismatch1.1.110 ALM-25937 SDH/SONET HP Remote Defect Indication1.1.111 ALM-25938 SDH/SONET HP Remote Error Indication1.1.112 ALM-25949 Excessive Flood Packet1.1.113 ALM-25950 Base Station Being Attacked1.1.114 ALM-26101 Inter-Board CANBUS Communication Failure1.1.115 ALM-26104 Board Temperature Unacceptable1.1.116 ALM-26106 Board Clock Input Unavailable1.1.117 ALM-26107 Board Input Voltage Out of Range1.1.118 ALM-26110 BBU Fan Stalled1.1.119 ALM-26111 BBU Fan Not at Full Speed1.1.120 ALM-26112 BBU DC Output Out of Range1.1.121 ALM-26113 Base Station DC Power Supply Abnormal1.1.122 ALM-26120 GPS Clock Output Unavailable1.1.123 ALM-26121 GPS Antenna Fault1.1.124 ALM-26122 GPS Locked Satellites Insufficient1.1.125 ALM-26123 GPS Maintenance Link Failure1.1.126 ALM-26200 Board Hardware Fault1.1.127 ALM-26201 Board Memory Soft Failure1.1.128 ALM-26202 Board Overload1.1.129 ALM-26203 Board Software Program Error1.1.130 ALM-26204 Board Not In Position1.1.131 ALM-26205 BBU Board Maintenance Link Failure1.1.132 ALM-26206 Main Control Board in Wrong Slot1.1.133 ALM-26208 Board File System Damaged1.1.134 ALM-26210 Board Blocked1.1.135 ALM-26214 Board Powered Off1.1.136 ALM-26215 Inter-Board Service Link Failure1.1.137 ALM-26216 Board Not Securely Installed1.1.138 ALM-26220 Transmission Optical Module Fault1.1.139 ALM-26221 Transmission Optical Module Not In Position1.1.140 ALM-26222 Transmission Optical Interface Error1.1.141 ALM-26223 Transmission Optical Interface Performance Degraded1.1.142 ALM-26230 BBU CPRI Optical Module Fault1.1.143 ALM-26231 BBU CPRI Optical Module or Electrical Port Not Ready1.1.144 ALM-26232 BBU Optical Module Transmit/Receive Fault1.1.145 ALM-26233 BBU CPRI Optical Interface Performance Degraded1.1.146 ALM-26234 BBU CPRI Interface Error1.1.147 ALM-26235 RF Unit Maintenance Link Failure1.1.148 ALM-26236 RRU Cascading Levels and Configuration Mismatch1.1.149 ALM-26237 RRU Network Breakpoint1.1.150 ALM-26238 RRU Network Topology Type and Configuration Mismatch1.1.151 ALM-26240 BBU Topology and Configuration Mismatch1.1.152 ALM-26241 Configuration File Update Failure1.1.153 ALM-26242 Configuration File Damaged1.1.154 ALM-26245 Configuration Data Inconsistency1.1.155 ALM-26250 Active Workspace Version Unavailable1.1.156 ALM-26251 Board Type and Configuration Mismatch
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
3 de 526 13/11/2012 9:15
-
1.1.157 ALM-26253 Board Software Auto-Supply Failure1.1.158 ALM-26254 Board Software Synchronization Failure1.1.159 ALM-26255 Automatic Version Rollback1.1.160 ALM-26260 System Clock Failure1.1.161 ALM-26261 External Clock Reference Not Configured1.1.162 ALM-26262 External Clock Reference Problem1.1.163 ALM-26263 IP Clock Link Failure1.1.164 ALM-26264 System Clock Unlocked1.1.165 ALM-26265 Base Station Frame Number Synchronization Error1.1.166 ALM-26266 Time Synchronization Failure1.1.167 ALM-26270 Inter-System Communication Failure1.1.168 ALM-26271 Inter-System Monitoring Device Parameter Settings Conflict1.1.169 ALM-26272 Inter-System RF Unit Parameter Settings Conflict1.1.170 ALM-26273 Inter-System BBU Board Parameter Settings Conflict1.1.171 ALM-26274 Inter-System Board Object Configuration Conflict1.1.172 ALM-26275 Inter-System Cabinet Configuration Conflict1.1.173 ALM-26276 Inter-System Site-Level Configuration Conflict1.1.174 ALM-26277 Inter-System Control Rights Conflict1.1.175 ALM-26278 RF Unit Working Mode and Mode Capability Inconsistency1.1.176 ALM-26279 Inter-System Board Installation and Configuration Mismatch1.1.177 ALM-26310 Inter-BBU Optical Module Fault1.1.178 ALM-26311 Inter-BBU Optical Module Not in Position1.1.179 ALM-26312 Inter-BBU Optical Module Receive Failure1.1.180 ALM-26313 Inter-BBU Optical Module Transmit Failure1.1.181 ALM-26314 Inter-BBU Port Failure1.1.182 ALM-26315 Inter-BBU Port Connection Error1.1.183 ALM-26501 RF Unit Optical Module or Electrical Port Not Ready1.1.184 ALM-26502 RF Unit Optical Module Type Mismatch1.1.185 ALM-26503 RF Unit Optical Module Transmit/Receive Fault1.1.186 ALM-26504 RF Unit CPRI Interface Error1.1.187 ALM-26506 RF Unit Optical Interface Performance Degraded1.1.188 ALM-26507 RF Unit Optical Module Fault1.1.189 ALM-26520 RF Unit TX Channel Gain Out of Range1.1.190 ALM-26521 RF Unit RX Channel RTWP/RSSI Too Low1.1.191 ALM-26522 RF Unit RX Channel RTWP/RSSI Unbalanced1.1.192 ALM-26524 RF Unit PA Overcurrent1.1.193 ALM-26525 RF Unit Temperature Unacceptable1.1.194 ALM-26527 RF Unit Input Power Out of Range1.1.195 ALM-26529 RF Unit VSWR Threshold Crossed1.1.196 ALM-26530 RF Unit ALD Current Out of Range1.1.197 ALM-26531 RF Unit ALD Switch Configuration Mismatch1.1.198 ALM-26532 RF Unit Hardware Fault1.1.199 ALM-26533 RF Unit Software Program Error1.1.200 ALM-26534 RF Unit Overload1.1.201 ALM-26536 RF Unit Multi-Mode Configuration Conflict1.1.202 ALM-26538 RF Unit Clock Problem1.1.203 ALM-26540 RF Unit AC Input Power Failure1.1.204 ALM-26541 ALD Maintenance Link Failure1.1.205 ALM-26542 RF Unit Backup Power Device Maintenance Link Failure1.1.206 ALM-26543 RF Unit External Device Maintenance Link Failure1.1.207 ALM-26544 RF Unit Power Surge Protector Fault1.1.208 ALM-26545 RF Unit TX Channel Switched Off Through Command1.1.209 ALM-26546 RF Unit External Power Supply Insufficient1.1.210 ALM-26751 RET Antenna Motor Fault1.1.211 ALM-26752 ALD Hardware Fault
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
4 de 526 13/11/2012 9:15
-
1.1.212 ALM-26753 RET Antenna Not Calibrated1.1.213 ALM-26754 RET Antenna Data Loss1.1.214 ALM-26755 TMA Bypass1.1.215 ALM-26756 SASU VSWR Threshold Crossed1.1.216 ALM-26757 RET Antenna Running Data and Configuration Mismatch1.1.217 ALM-26758 TMA Running Data and Configuration Mismatch1.1.218 ALM-26759 SASU Running Data and Configuration Mismatch1.1.219 ALM-26760 SASU Bypass1.1.220 ALM-26765 RHUB Hardware Fault1.1.221 ALM-26766 RHUB Software Program Error1.1.222 ALM-26767 RHUB Overload1.1.223 ALM-26768 RHUB Clock Problem1.1.224 ALM-26770 UPS Surge Protection Device Fault1.1.225 ALM-26771 Mains Breakdown with UPS1.1.226 ALM-26772 UPS Battery Undervoltage1.1.227 ALM-26773 UPS Failure1.1.228 ALM-26774 RHUB AC/DC Maintenance Link Failure1.1.229 ALM-26775 RHUB AC/DC Module Problem1.1.230 ALM-26776 RHUB PSE Power Supply Failure1.1.231 ALM-26777 RHUB PSE Fault1.1.232 ALM-26780 RHUB Optical Module or Electrical Port Not Ready1.1.233 ALM-26781 RHUB Optical Module Type Mismatch1.1.234 ALM-26782 RHUB Optical Module Transmit/Receive Fault1.1.235 ALM-26783 RHUB CPRI Interface Error1.1.236 ALM-26785 RHUB Optical Interface Performance Degraded1.1.237 ALM-26786 RHUB Optical Module Fault1.1.238 ALM-26787 RHUB-PRRU CPRI Interface Error1.1.239 ALM-26810 License Data Loss1.1.240 ALM-26811 Configured Capacity Limit Exceeding Licensed Limit1.1.241 ALM-26812 System Dynamic Traffic Exceeding Licensed Limit1.1.242 ALM-26830 Local User Consecutive Login Retries Failed1.1.243 ALM-26832 Peer Certificate Expiry1.1.244 ALM-26840 Imminent Certificate Expiry1.1.245 ALM-26841 Certificate Invalid1.1.246 ALM-26842 Automatic Certificate Update Failed1.1.247 ALM-28201 Local Cell Blocked1.1.248 ALM-28203 Local Cell Unusable1.1.249 ALM-28204 Cell DL Load Simulation Startup1.1.250 ALM-28205 Cell Output Power too Low1.1.251 ALM-28206 Local Cell Capability Decline1.1.252 ALM-28207 Carrier Wave Share Failure1.1.253 ALM-28209 Cell No Traffic1.1.254 ALM-28210 Frequency Separation Configuration Mismatch1.1.255 ALM-28211 Cell Configuration Abnormal1.1.256 ALM-28221 IMB Local Cell Blocked1.1.257 ALM-28223 IMB Local Cell Unusable1.1.258 ALM-28224 IMB Cell Output Power too Low1.1.259 ALM-28225 IMB Local Cell Capability Decline1.1.260 ALM-28226 IMB Cell Configuration Abnormal1.1.261 ALM-28230 Base Station Service Overload1.1.262 ALM-28244 GPS Receiver Hardware Fault1.1.263 ALM-28245 GPS Receiver Antenna Power Problem1.1.264 ALM-28246 GPS Receiver Antenna Fault1.1.265 ALM-28247 GPS Receiver Software Program Error1.1.266 ALM-28248 GPS Receiver Position Not Locked
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
5 de 526 13/11/2012 9:15
-
1.1.267 ALM-28249 GPS Receiver Maintenance Link Failure1.1.268 ALM-28250 GPS Receiver Initialization Configuration Failure1.1.269 ALM-28253 Ethernet Link Abnormal1.1.270 ALM-28255 Transport Configuration Failure1.1.271 ALM-28300 Board Uplink Service Processing Channel Abnormal1.1.272 ALM-28301 Board Downlink Service Processing Channel Abnormal1.1.273 ALM-28302 Board BFN Abnormal1.1.274 ALM-28303 WBBP-WBBP Interface Abnormal1.1.275 ALM-28329 RF Unit Input Power Abnormal1.1.276 ALM-28330 RF Unit Over Backward Power Alarm1.1.277 ALM-28350 Board Configuration Inconsistent with Resource Group Configuration1.1.278 ALM-28354 Transport Backup Not Support1.1.279 ALM-28355 Data Configuration File Error1.1.280 ALM-28381 Board Startup Abnormal Alarm1.1.281 ALM-65033-ALM-65233 External Analog/Boolean Alarm1.2 NodeB Event Reference1.2.1 NodeB Event List1.2.2 EVT-25890 SCTP Link Path Switchover1.2.3 EVT-25893 Remote Maintenance Link Switchover1.2.4 EVT-26212 Board Startup1.2.5 EVT-26213 NE Startup1.2.6 EVT-26256 NE Software Download Started1.2.7 EVT-26257 NE Software Download Ended1.2.8 EVT-26258 NE Software Activation Started1.2.9 EVT-26259 NE Software Activation Ended1.2.10 EVT-26505 RF Unit CPRI Interface Switchover1.2.11 EVT-26526 RF Unit TX Channel Switched Off1.2.12 EVT-26528 RF Unit TX Channel Switched On1.2.13 EVT-26535 RF Unit Startup1.2.14 EVT-26784 RHUB CPRI Interface Switchover1.2.15 EVT-26820 License Emergency Status Activated1.2.16 EVT-26821 License Emergency Status Ceased1.2.17 EVT-28200 Iub Common Procedure Failure Indication1.2.18 EVT-28202 Local Cell Rebuild1.2.19 EVT-28222 IMB Local Cell Rebuild1.2.20 EVT-28251 Ethernet Configuration Changed1.2.21 EVT-28252 IP RAN Object Reset1.2.22 EVT-28352 Enable Downloaded Configuration File1.2.23 EVT-28353 Disable Downloaded Configuration File1.2.24 EVT-28380 NE Shutdown
1 Fault Management
Related Document Description
NodeB Alarm Reference This document describes NodeB alarm reference.
NodeB Event Reference This document describes NodeB event reference.
1.1 NodeB Alarm Reference
Purpose
This document describes all the alarms of the BTS3900 WCDMA, BTS3900A WCDMA, BTS3900L WCDMA,
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
6 de 526 13/11/2012 9:15
-
BTS3900C WCDMA, BTS3900AL WCDMA, and DBS3900 WCDMA. The MML commands involved in thisdocument takes NodeB_2U for example.
Version
The following table lists the product versions involved in this document.
Product Name Version
BTS3900 WCDMA (hereinafter referred to as BTS3900) V200R014C00
BTS3900A WCDMA (hereinafter referred to as BTS3900A) V200R014C00
BTS3900L WCDMA (hereinafter referred to as BTS3900L) V200R014C00
BTS3900C WCDMA (hereinafter referred to as BTS3900C) V200R014C00
BTS3900AL WCDMA (hereinafter referred to as BTS3900AL) V200R014C00
DBS3900 WCDMA (hereinafter referred to as DBS3900) V200R014C00
Intended Audience
This document is intended for:
Field engineers
System engineers
Shift operators
Site maintainers
Network operators
Concepts
Concept Description
Alarm ID Unique identifier of an alarm in one product.
Alarm Name Unique name of an alarm in one product. Alarm names clearly and accurately indicate alarmmeanings. There is a one-to-one mapping between alarm names and IDs.
Alarm Type There is only one alarm type: fault.
Alarm Level Impact of an alarm on service quality. There are four alarm severity levels: critical, major,minor, and warning.
Critical alarm: affects service quality. If a critical alarm is generated, immediateactions are necessary even when the fault occurs during non-working hours.Major alarm: affects service quality and requires immediate action during workinghours.Minor alarm: generally does not affect service quality, but requires handling orobservation in a reasonable amount of time to avoid more serious faults.Warning alarm: indicates a potential error that may affect service quality. Itrequires different actions depending on errors.
Event Type There are 16 event types based on monitored objects.Power alarm: relates to the power system.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
7 de 526 13/11/2012 9:15
-
Concept Description
Environment alarm: relates to equipment room environment variables, such astemperature, humidity, and door control.Signaling alarm: relates to channel associated signaling (for example, SS1) andcommon channel signaling (for example, SS7).Trunk alarm: relates to the trunk system, including trunk circuits and boards.Hardware alarm: relates to hardware, such as the clock unit and CPU.Software alarm: relates to software.System alarm: generated during system operation.Communication alarm: relates to communication.Service quality alarm: relates to service quality.Unexpected operation alarm: generated when an exception occurs.OMC alarm: generated when the OMC is not working properly.Integrity alarm: generated when information is illegally modified or deleted.Operation alarm: generated when service is unavailable or inaccessible becauseof inappropriate operations.Physical resource alarm: generated when physical resources are damaged by asuspected security attack.Security alarm: generated when security service or a security mechanism hasdetected that the system encounters security attacks.Time domain alarm: generated when an event occurs at an unexpected orforbidden time.
Description Conditions in which an alarm is generated.
Parameters Parameters related to alarms.
Impact on theSystem
Impact of an alarm on the system or services.
System Actions Actions taken by the system when an alarm is generated.
PossibleCauses
Issues that may result in an alarm. Possible causes are categorized into data configuration,hardware, software, and other causes.
Procedure Procedure for clearing an alarm step by step.
Change History
For detailed alarm changes, see the release notes.
1.1.1 NodeB Alarm List
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-25600 Monitoring DeviceMaintenance LinkFailure
Fault Major Communication
ALM-25601 Monitoring DeviceHardware Fault
Fault Major Hardware
ALM-25602 Sensor Failure Fault Major Hardware
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
8 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-25620 Monitoring DevicePower SupplyProblem
Fault Major Hardware
ALM-25621 Power Supply DCOutput Out ofRange
Fault Major Power
ALM-25622 Mains Input Out ofRange
Fault Major Power
ALM-25623 Load Disconnected Fault Major/Warning Power
ALM-25624 Battery PowerUnavailable
Fault Major/Warning Power
ALM-25625 Battery CurrentOut of Range
Fault Major Power
ALM-25626 Power ModuleAbnormal
Fault Major/Warning Power
ALM-25628 AC SurgeProtector Fault
Fault Major Power
ALM-25630 Power Module andMonitoring ModuleCommunicationFailure
Fault Major Power
ALM-25631 Load Fuse Broken Fault Major Power
ALM-25632 Battery CabinHeater Fault
Fault Major Power
ALM-25633 PMU InternalInterfaceCommunicationFailure
Fault Major Power
ALM-25634 Battery Not InPosition
Fault Major Power
ALM-25636 Loss of PowerSupplyRedundancy
Fault Warning Power
ALM-25650 AmbientTemperatureUnacceptable
Fault Major/Minor Environment
ALM-25651 Ambient HumidityUnacceptable
Fault Minor Environment
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
9 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-25652 CabinetTemperatureUnacceptable
Fault Major/Minor Environment
ALM-25653 Cabinet HumidityUnacceptable
Fault Minor Environment
ALM-25654 BatteryTemperatureUnacceptable
Fault Major/Minor Power
ALM-25655 Cabinet Air OutletTemperatureUnacceptable
Fault Major/Minor Environment
ALM-25656 Cabinet Air InletTemperatureUnacceptable
Fault Major/Minor Environment
ALM-25657 TEC Cooler Fault Fault Major Environment
ALM-25670 Water Alarm Fault Critical Environment
ALM-25671 Smoke Alarm Fault Critical Environment
ALM-25672 Burglar Alarm Fault Critical Environment
ALM-25673 Fan Stalled Fault Major Hardware
ALM-25695 Diesel GeneratorFault
Fault Major Hardware
ALM-25696 Diesel GeneratorLow Fuel
Fault Major Hardware
ALM-25697 Diesel GeneratorStartup Failure
Fault Major Hardware
ALM-25710 Loss of SolarArray
Fault Major Hardware
ALM-25711 Solar Array Fault Fault Major Hardware
ALM-25713 Solar ControllerTemperatureUnacceptable
Fault Minor Hardware
ALM-25719 CCU Topology andConfigurationMismatch
Fault Major Environment
ALM-25720 Inter-CCU PortConnection Error
Fault Major Environment
ALM-25721 CCU-BBUCommunication
Fault Minor Environment
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
10 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
Failure
ALM-25800 E1/T1 Loss ofSignal
Fault Major Trunk
ALM-25801 E1/T1 AlarmIndication Signal
Fault Major Trunk
ALM-25802 E1/T1 RemoteAlarm IndicationSignal
Fault Minor Trunk
ALM-25803 E1/T1 Loss ofFrame Alignment
Fault Major Trunk
ALM-25804 E1/T1 Loss ofMultiframeAlignment
Fault Minor Trunk
ALM-25805 E1/T1 ExcessiveSlip Frames
Fault Minor Trunk
ALM-25806 E1/T1 ExcessiveBit Error Rate
Fault Minor Trunk
ALM-25807 E1/T1 Loopback Fault Minor Trunk
ALM-25820 Fractional ATMLink Loss of CellDelineation
Fault Major Trunk
ALM-25821 IMA/ATM LinkLoss of CellDelineation
Fault Major Trunk
ALM-25823 IMA Link Loss ofFrame
Fault Major Trunk
ALM-25824 IMA Link Out ofDelaySynchronization
Fault Major Trunk
ALM-25825 IMA Link RemoteFailure Indication
Fault Minor Trunk
ALM-25826 IMA Link RX Fault Fault Major Trunk
ALM-25827 IMA Link TXUnusable at FarEnd
Fault Minor Trunk
ALM-25828 IMA Link RXUnusable at FarEnd
Fault Minor Trunk
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
11 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-25829 IMA Group Startupat Far End
Fault Minor Trunk
ALM-25830 IMA GroupConfigurationAborted
Fault Major Trunk
ALM-25831 IMA GroupConfigurationAborted at Far End
Fault Minor Trunk
ALM-25832 IMA GroupActivated LinksInsufficient
Fault Major Trunk
ALM-25833 IMA GroupActivated LinksInsufficient at FarEnd
Fault Minor Trunk
ALM-25834 IMA GroupBlocked at Far End
Fault Minor Trunk
ALM-25835 NCP Fault Fault Major Communication
ALM-25836 CCP Fault Fault Major Communication
ALM-25837 ALCAP Fault Fault Major Signaling
ALM-25838 AAL2 Path Fault Fault Major Trunk
ALM-25840 SAAL Link Fault Fault Major Trunk
ALM-25841 SAAL LinkCongestion
Fault Major Trunk
ALM-25860 PPP/MLPPP LinkFault
Fault Major Trunk
ALM-25861 MLPPP GroupFault
Fault Major Trunk
ALM-25862 MLPPP GroupExcessive PacketLoss Rate
Fault Minor Trunk
ALM-25863 PPP LinkExcessive FrameError Rate
Fault Minor Trunk
ALM-25879 Ethernet PortBroadcast PacketsExceeding Alarm
Fault Major Trunk
ALM-25880 Ethernet Link Fault Fault Major Trunk
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
12 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-25881 MAC ExcessiveFrame Error Rate
Fault Minor Trunk
ALM-25882 ETHOAM 3AHDiscovery Failure
Fault Minor Trunk
ALM-25883 ETHOAM 3AHLocal Fault
Fault Minor Trunk
ALM-25884 ETHOAM 3AHRemote Fault
Fault Minor Trunk
ALM-25885 IP Address Conflict Fault Minor Trunk
ALM-25886 IP Path Fault Fault Major Trunk
ALM-25887 Ethernet TrunkLink Fault
Fault Minor Trunk
ALM-25888 SCTP Link Fault Fault Major Trunk
ALM-25889 SCTP LinkCongestion
Fault Minor Trunk
ALM-25891 IKE NegotiationFailure
Fault Major Trunk
ALM-25894 ETHOAM 3AHRemote Loopback
Fault Major Trunk
ALM-25895 Ethernet TrunkGroup Fault
Fault Major Trunk
ALM-25896 IP RemoteLoopback
Fault Major Trunk
ALM-25897 IP ExcessiveFrame Error Rate
Fault Minor Trunk
ALM-25898 IP Path ExcessivePacket Loss Rate
Fault Minor Trunk
ALM-25899 BFD Session Fault Fault Minor Trunk
ALM-25900 IP PM ActivationFailure
Fault Minor Trunk
ALM-25901 RemoteMaintenance LinkFailure
Fault Major Trunk
ALM-25902 RemoteMaintenance LinkRunning Data andConfigurationMismatch
Fault Minor Trunk
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
13 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-25920 SDH/SONET Lossof FrameAlignment
Fault Major Trunk
ALM-25921 SDH/SONET Lossof Frame
Fault Major Trunk
ALM-25922 SDH/SONET Lossof Signal
Fault Major Trunk
ALM-25923 SDH/SONET AULoss of Pointer
Fault Major Trunk
ALM-25924 SDH/SONET MSAlarm IndicationSignal
Fault Major Trunk
ALM-25925 SDH/SONET MSRemote DefectIndication
Fault Major Trunk
ALM-25926 SDH/SONET Lossof Cell Delineation
Fault Major Trunk
ALM-25927 SDH/SONETOptical PortLoopback
Fault Warning Trunk
ALM-25928 SDH/SONET RSTrace IdentifierMismatch
Fault Minor Trunk
ALM-25929 SDH/SONET RSExcessive Bit ErrorRate
Fault Minor Trunk
ALM-25930 SDH/SONET MSExcessive Bit ErrorRate
Fault Minor Trunk
ALM-25931 SDH/SONET MSSignal Degraded
Fault Major Trunk
ALM-25932 SDH/SONET MSRemote ErrorIndication
Fault Major Trunk
ALM-25933 SDH/SONET AUAlarm IndicationSignal
Fault Major Trunk
ALM-25934 SDH/SONET HPUnequipped Defect
Fault Major Trunk
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
14 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-25935 SDH/SONET HPSignal LabelMismatch
Fault Minor Trunk
ALM-25936 SDH/SONET HPTrace IdentifierMismatch
Fault Minor Trunk
ALM-25937 SDH/SONET HPRemote DefectIndication
Fault Major Trunk
ALM-25938 SDH/SONET HPRemote ErrorIndication
Fault Major Trunk
ALM-25949 Excessive FloodPacket
Fault Major Trunk
ALM-25950 Base Station BeingAttacked
Fault Major Security
ALM-26101 Inter-BoardCANBUSCommunicationFailure
Fault Minor Hardware
ALM-26104 BoardTemperatureUnacceptable
Fault Major/Minor Environment
ALM-26106 Board Clock InputUnavailable
Fault Major Hardware
ALM-26107 Board InputVoltage Out ofRange
Fault Major Hardware
ALM-26110 BBU Fan Stalled Fault Major Hardware
ALM-26111 BBU Fan Not atFull Speed
Fault Major Hardware
ALM-26112 BBU DC OutputOut of Range
Fault Major Power
ALM-26113 Base Station DCPower SupplyAbnormal
Fault Major Power
ALM-26120 GPS Clock OutputUnavailable
Fault Minor Hardware
ALM-26121 GPS Antenna Fault Fault Minor Hardware
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
15 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-26122 GPS LockedSatellitesInsufficient
Fault Minor Running
ALM-26123 GPS MaintenanceLink Failure
Fault Minor Running
ALM-26200 Board HardwareFault
Fault Major/Minor Hardware
ALM-26201 Board MemorySoft Failure
Fault Minor Hardware
ALM-26202 Board Overload Fault Minor Running
ALM-26203 Board SoftwareProgram Error
Fault Major Running
ALM-26204 Board Not InPosition
Fault Major Hardware
ALM-26205 BBU BoardMaintenance LinkFailure
Fault Major Hardware
ALM-26206 Main ControlBoard in WrongSlot
Fault Major Hardware
ALM-26208 Board File SystemDamaged
Fault Major Hardware
ALM-26210 Board Blocked Fault Major Running
ALM-26214 Board PoweredOff
Fault Major Hardware
ALM-26215 Inter-BoardService LinkFailure
Fault Major Hardware
ALM-26216 Board NotSecurely Installed
Fault Major Hardware
ALM-26220 TransmissionOptical ModuleFault
Fault Warning Hardware
ALM-26221 TransmissionOptical Module NotIn Position
Fault Major Hardware
ALM-26222 TransmissionOptical InterfaceError
Fault Major/Minor Hardware
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
16 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-26223 TransmissionOptical InterfacePerformanceDegraded
Fault Major/Minor Communication
ALM-26230 BBU CPRI OpticalModule Fault
Fault Warning Hardware
ALM-26231 BBU CPRI OpticalModule orElectrical Port NotReady
Fault Major Hardware
ALM-26232 BBU OpticalModuleTransmit/ReceiveFault
Fault Major/Minor Hardware
ALM-26233 BBU CPRI OpticalInterfacePerformanceDegraded
Fault Major/Minor Hardware
ALM-26234 BBU CPRIInterface Error
Fault Major Hardware
ALM-26235 RF UnitMaintenance LinkFailure
Fault Major Hardware
ALM-26236 RRU CascadingLevels andConfigurationMismatch
Fault Major Hardware
ALM-26237 RRU NetworkBreakpoint
Fault Major Hardware
ALM-26238 RRU NetworkTopology Type andConfigurationMismatch
Fault Major Hardware
ALM-26240 BBU Topology andConfigurationMismatch
Fault Major Hardware
ALM-26241 Configuration FileUpdate Failure
Fault Major Running
ALM-26242 Configuration FileDamaged
Fault Major Running
ALM-26245 Configuration DataInconsistency
Fault Major Running
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
17 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-26250 Active WorkspaceVersionUnavailable
Fault Major Running
ALM-26251 Board Type andConfigurationMismatch
Fault Major Running
ALM-26253 Board SoftwareAuto-SupplyFailure
Fault Major Running
ALM-26254 Board SoftwareSynchronizationFailure
Fault Major Running
ALM-26255 Automatic VersionRollback
Fault Major Running
ALM-26260 System ClockFailure
Fault Major Hardware
ALM-26261 External ClockReference NotConfigured
Fault Minor Hardware
ALM-26262 External ClockReferenceProblem
Fault Minor Hardware
ALM-26263 IP Clock LinkFailure
Fault Minor Hardware
ALM-26264 System ClockUnlocked
Fault Major/Minor Hardware
ALM-26265 Base StationFrame NumberSynchronizationError
Fault Major Hardware
ALM-26266 TimeSynchronizationFailure
Fault Minor Communication
ALM-26270 Inter-SystemCommunicationFailure
Fault Major Hardware
ALM-26271 Inter-SystemMonitoring DeviceParameterSettings Conflict
Fault Warning Running
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
18 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-26272 Inter-System RFUnit ParameterSettings Conflict
Fault Major/Warning Running
ALM-26273 Inter-System BBUBoard ParameterSettings Conflict
Fault Major/Warning Running
ALM-26274 Inter-SystemBoard ObjectConfigurationConflict
Fault Major Running
ALM-26275 Inter-SystemCabinetConfigurationConflict
Fault Minor Running
ALM-26276 Inter-SystemSite-LevelConfigurationConflict
Fault Major Running
ALM-26277 Inter-SystemControl RightsConflict
Fault Major Running
ALM-26278 RF Unit WorkingMode and ModeCapabilityInconsistency
Fault Major Hardware
ALM-26279 Inter-SystemBoard Installationand ConfigurationMismatch
Fault Minor Software
ALM-26310 Inter-BBU OpticalModule Fault
Fault Warning Hardware
ALM-26311 Inter-BBU OpticalModule Not inPosition
Fault Major Hardware
ALM-26312 Inter-BBU OpticalModule ReceiveFailure
Fault Major/Minor Hardware
ALM-26313 Inter-BBU OpticalModule TransmitFailure
Fault Major/Minor Hardware
ALM-26314 Inter-BBU PortFailure
Fault Major Hardware
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
19 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-26315 Inter-BBU PortConnection Error
Fault Major Hardware
ALM-26501 RF Unit OpticalModule orElectrical Port NotReady
Fault Major Communication
ALM-26502 RF Unit OpticalModule TypeMismatch
Fault Major Communication
ALM-26503 RF Unit OpticalModuleTransmit/ReceiveFault
Fault Major Communication
ALM-26504 RF Unit CPRIInterface Error
Fault Major Communication
ALM-26506 RF Unit OpticalInterfacePerformanceDegraded
Fault Major Communication
ALM-26507 RF Unit OpticalModule Fault
Fault Warning Communication
ALM-26520 RF Unit TXChannel Gain Outof Range
Fault Minor Hardware
ALM-26521 RF Unit RXChannelRTWP/RSSI TooLow
Fault Minor Hardware
ALM-26522 RF Unit RXChannelRTWP/RSSIUnbalanced
Fault Minor Hardware
ALM-26524 RF Unit PAOvercurrent
Fault Major Hardware
ALM-26525 RF UnitTemperatureUnacceptable
Fault Major/Minor Hardware
ALM-26527 RF Unit InputPower Out ofRange
Fault Major Hardware
ALM-26529 RF Unit VSWRThreshold Crossed
Fault Major/Minor Hardware
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
20 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-26530 RF Unit ALDCurrent Out ofRange
Fault Minor/Warning Hardware
ALM-26531 RF Unit ALDSwitchConfigurationMismatch
Fault Minor Hardware
ALM-26532 RF Unit HardwareFault
Fault Major/Minor Hardware
ALM-26533 RF Unit SoftwareProgram Error
Fault Major Running
ALM-26534 RF Unit Overload Fault Minor Running
ALM-26536 RF Unit Multi-ModeConfigurationConflict
Fault Minor Running
ALM-26538 RF Unit ClockProblem
Fault Major Hardware
ALM-26540 RF Unit AC InputPower Failure
Fault Major Power
ALM-26541 ALD MaintenanceLink Failure
Fault Major Communication
ALM-26542 RF Unit BackupPower DeviceMaintenance LinkFailure
Fault Major Communication
ALM-26543 RF Unit ExternalDeviceMaintenance LinkFailure
Fault Major Communication
ALM-26544 RF Unit PowerSurge ProtectorFault
Fault Major Hardware
ALM-26545 RF Unit TXChannel SwitchedOff ThroughCommand
Fault Warning Running
ALM-26546 RF Unit ExternalPower SupplyInsufficient
Fault Major/Minor Hardware
ALM-26751 RET AntennaMotor Fault
Fault Minor Hardware
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
21 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-26752 ALD HardwareFault
Fault Major/Minor Hardware
ALM-26753 RET Antenna NotCalibrated
Fault Minor Hardware
ALM-26754 RET Antenna DataLoss
Fault Minor Hardware
ALM-26755 TMA Bypass Fault Major Hardware
ALM-26756 SASU VSWRThreshold Crossed
Fault Major Hardware
ALM-26757 RET AntennaRunning Data andConfigurationMismatch
Fault Minor Hardware
ALM-26758 TMA Running Dataand ConfigurationMismatch
Fault Minor Hardware
ALM-26759 SASU RunningData andConfigurationMismatch
Fault Minor Hardware
ALM-26760 SASU Bypass Fault Major Hardware
ALM-26765 RHUB HardwareFault
Fault Major/Minor Hardware
ALM-26766 RHUB SoftwareProgram Error
Fault Major Running
ALM-26767 RHUB Overload Fault Minor Running
ALM-26768 RHUB ClockProblem
Fault Major Hardware
ALM-26770 UPS SurgeProtection DeviceFault
Fault Major Hardware
ALM-26771 Mains Breakdownwith UPS
Fault Major Hardware
ALM-26772 UPS BatteryUndervoltage
Fault Major Hardware
ALM-26773 UPS Failure Fault Major Hardware
ALM-26774 RHUB AC/DCMaintenance LinkFailure
Fault Major Hardware
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
22 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-26775 RHUB AC/DCModule Problem
Fault Major Hardware
ALM-26776 RHUB PSE PowerSupply Failure
Fault Major Hardware
ALM-26777 RHUB PSE Fault Fault Major Hardware
ALM-26780 RHUB OpticalModule orElectrical Port NotReady
Fault Major Communication
ALM-26781 RHUB OpticalModule TypeMismatch
Fault Major Communication
ALM-26782 RHUB OpticalModuleTransmit/ReceiveFault
Fault Major Communication
ALM-26783 RHUB CPRIInterface Error
Fault Major Communication
ALM-26785 RHUB OpticalInterfacePerformanceDegraded
Fault Major/Minor Communication
ALM-26786 RHUB OpticalModule Fault
Fault Minor Communication
ALM-26787 RHUB-PRRU CPRIInterface Error
Fault Major Communication
ALM-26810 License Data Loss Fault Major Running
ALM-26811 ConfiguredCapacity LimitExceedingLicensed Limit
Fault Major Running
ALM-26812 System DynamicTraffic ExceedingLicensed Limit
Fault Major Running
ALM-26830 Local UserConsecutive LoginRetries Failed
Fault Minor Security
ALM-26832 Peer CertificateExpiry
Fault Minor Security
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
23 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-26840 ImminentCertificate Expiry
Fault Minor Security
ALM-26841 Certificate Invalid Fault Major Security
ALM-26842 AutomaticCertificate UpdateFailed
Fault Minor Security
ALM-28201 Local Cell Blocked Fault Minor QoS
ALM-28203 Local CellUnusable
Fault Major QoS
ALM-28204 Cell DL LoadSimulation Startup
Fault Minor QoS
ALM-28205 Cell Output Powertoo Low
Fault Minor QoS
ALM-28206 Local CellCapability Decline
Fault Major QoS
ALM-28207 Carrier WaveShare Failure
Fault Minor QoS
ALM-28209 Cell No Traffic Fault Minor QoS
ALM-28210 FrequencySeparationConfigurationMismatch
Fault Minor QoS
ALM-28211 Cell ConfigurationAbnormal
Fault Major QoS
ALM-28221 IMB Local CellBlocked
Fault Minor QoS
ALM-28223 IMB Local CellUnusable
Fault Major QoS
ALM-28224 IMB Cell OutputPower too Low
Fault Minor QoS
ALM-28225 IMB Local CellCapability Decline
Fault Major QoS
ALM-28226 IMB CellConfigurationAbnormal
Fault Major QoS
ALM-28230 Base StationService Overload
Fault Minor QoS
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
24 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-28244 GPS ReceiverHardware Fault
Fault Minor Hardware
ALM-28245 GPS ReceiverAntenna PowerProblem
Fault Minor Hardware
ALM-28246 GPS ReceiverAntenna Fault
Fault Minor Hardware
ALM-28247 GPS ReceiverSoftware ProgramError
Fault Minor Hardware
ALM-28248 GPS ReceiverPosition NotLocked
Fault Minor Hardware
ALM-28249 GPS ReceiverMaintenance LinkFailure
Fault Minor Communication
ALM-28250 GPS ReceiverInitializationConfigurationFailure
Fault Minor Hardware
ALM-28253 Ethernet LinkAbnormal
Fault Major Trunk
ALM-28255 TransportConfigurationFailure
Fault Major Running
ALM-28300 Board UplinkService ProcessingChannel Abnormal
Fault Major Hardware
ALM-28301 Board DownlinkService ProcessingChannel Abnormal
Fault Major/Minor Hardware
ALM-28302 Board BFNAbnormal
Fault Major Hardware
ALM-28303 WBBP-WBBPInterface Abnormal
Fault Major Hardware
ALM-28329 RF Unit InputPower Abnormal
Fault Major Hardware
ALM-28330 RF Unit OverBackward PowerAlarm
Fault Major Hardware
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
25 de 526 13/11/2012 9:15
-
Alarm ID Alarm Name Alarm Type Alarm Level Event Type
ALM-28350 BoardConfigurationInconsistent withResource GroupConfiguration
Fault Major Running
ALM-28354 Transport BackupNot Support
Fault Major Running
ALM-28355 Data ConfigurationFile Error
Fault Major Running
ALM-28381 Board StartupAbnormal Alarm
Fault Major Running
ALM-65033-ALM-65233
ExternalAnalog/BooleanAlarm
Fault Major Environment
1.1.2 ALM-25600 Monitoring Device Maintenance Link FailureDescription
This alarm is reported when the maintenance link between the BBU/RRU and the monitoring device fails or themaintenance link between monitoring devices fails.
Parameters
Parameter Name Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Board Type Type of the monitoring device
Connect Port No. Serial port No. connected to the monitoring device
Communication Address Communication address of the monitoring device
Impact on the System
Alarm Severity Alarm Impact
Major The system cannot monitor the status of the monitoring device.Operators cannot configure or maintain the monitoring device.
System Actions
None
Possible Causes
The monitoring device is configured in a wrong cabinet/subrack/slot, or configured with a wrong serialport or communication address.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
26 de 526 13/11/2012 9:15
-
The monitoring device is not powered on or fails to be detected.
The cable connections are faulty between the BBU/RRU and the monitoring device, between CCUs,or between a CCU and another monitoring device.
The cable is loose, worn-out, or broken between the BBU/RRU and the monitoring device, betweenCCUs, or between a CCU and another monitoring device.
The DIP switch setting of the monitoring device is wrong.
The monitoring device is faulty.
The BBU is faulty.
Procedure
Check the configuration on the M2000.
Run the MML command SCN RS485 to check whether the cabinet/subrack/slot,connected serial port, and communication address of the faulty monitoring device, aswell as the cabinet/subrack/slot of the device managing the faulty monitoring device areconsistent with the configuration plan.
Y => The information is consistent. Go to step 2.
N => The information is inconsistent. Go to sub-step b.
a.
Run the MML command RMV PMU(PMU)/RMV TCU(TCU)/RMV EMU(EMU)/RMVFMU(FMU) to remove the faulty monitoring device.Run the MML command ADD PMU(PMU)/ADD TCU(TCU)/ADD EMU(EMU)/ADDFMU(FMU) to add the monitoring device according to the configuration plan.Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
b.
1.
Check the monitoring device on site.
Check whether the monitoring device specified in the alarm location parameters isproperly installed and powered on. When the power switch is turned on and the RUNindicator is on, it indicates that the monitoring device is powered on.
Y => The monitoring device is properly installed and powered on. Go to step 3.
N => The monitoring device is improperly installed or not powered on. Go to sub-step b.
a.
Install the monitoring device properly and power it on.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
b.
2.
Check the cable connections for the monitoring device on site.
Check whether the cables for the monitoring device are properly connected based onthe installation guide.
Y => The cables are properly connected. Go to sub-step c.
N => The cables are improperly connected. Go to sub-step b.
a.
Reconnect the cables properly for the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
b.
3.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
27 de 526 13/11/2012 9:15
-
N => The alarm is not cleared. Go to sub-step c.
Check whether the cables for the monitoring device are functional and the connectionsare correct.
Y => The cables are functional and the connections are correct. Go to step 4.
N => The cables are loose, worn-out, damaged, or incorrectly connected. Go tosub-step d.
c.
Reconnect or replace the cables.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 4.
d.
(Skip this step and go to step 5 if the device is not configured with the DIP switch) Check thecommunication address of the monitoring device on site.
Check the DIP switch settings of the monitoring device.
Y => The DIP switch settings are correct. Go to step 5.
N => The DIP switch settings are incorrect. Go to sub-step b.
a.
Power off the monitoring device, set the DIP switch correctly, and then power on themonitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 5.
b.
4.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 6.
a.
5.
Replace the faulty unit of the BBU on site.
Note: If there is only one UPEU configured in the BBU or there are two UPEUsconfigured in the high-power-consumption BBU, replacing the UPEU interrupts all theongoing services of the base station. Therefore, perform the replacement in low-traffichours.
Replace the BBU environment interface unit on site.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to sub-step b.
a.
Note: Replacing the main control board interrupts all the ongoing services of the basestation. Therefore, perform the replacement in low-traffic hours. A base stationsoftware upgrade may be required during board replacement, so the correct softwareversion must be ready for use in advance.
Replace the main control board on site.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
b.
6.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
28 de 526 13/11/2012 9:15
-
N => The alarm is not cleared. Contact Huawei Customer Service Center.
1.1.3 ALM-25601 Monitoring Device Hardware FaultDescription
This alarm is reported when the hardware of the monitoring device is faulty.
Parameters
Parameter Name Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Board Type Type of the monitoring device
Impact on the System
Alarm Severity Alarm Impact
Major Some or all the monitoring functions of the monitoring device fail.
System Actions
None
Possible Causes
The software of the monitoring device malfunctions.
The hardware of the monitoring device is faulty.
Procedure
Reset the monitoring device on the M2000.
Run the MML command RST BRD to reset the faulty monitoring device on the M2000.
Wait until the startup is complete, Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
a.
1.
Power cycle the monitoring device on site.
Power cycle the faulty monitoring device, or remove and then insert the faultymonitoring device on site.
Wait until the startup is complete, Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
a.
2.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
a.
3.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
29 de 526 13/11/2012 9:15
-
N => The alarm is not cleared. Contact Huawei Customer Service Center.
1.1.4 ALM-25602 Sensor Failure
Description
This alarm is reported when a sensor is faulty.
Parameters
ParameterName Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Sensor No. Faulty sensor number (Battery temperature sensor 1, Battery temperature sensor 2, Cabinethumidity sensor, Cabinet temperature sensor 1, Cabinet temperature sensor 2, Cabinet ambienttemperature sensor, Air inlet temperature sensor, Air outlet temperature sensor, Current sensorof the diesel generator)
Board Type Type of the monitoring device
Impact on the System
Alarm Severity Alarm Impact
Major The system cannot monitor the alarms detected by the sensor.
System Actions
None
Possible Causes
The cable connection of the sensor is faulty.
The sensor is faulty.
The corresponding monitoring device is faulty.
Procedure
Check for the correlated alarm on the M2000.
Check for the correlated alarm on the M2000:
25600 Monitoring Device Maintenance Link Failure (the "Board Type" parameter isTCU.)Y => The correlated alarm exists. Go to sub-step b.
N => The correlated alarm does not exist. Go to step 2.
a.
Clear the correlated alarm according to the relevant handling suggestions.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
b.
1.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
30 de 526 13/11/2012 9:15
-
Check the sensor and its cable connection on site.
Check whether the cable between the monitoring device and the sensor is functionaland the connection is correct.
Y => The cable is functional and the connection is correct. Go to step 3.
N => The cable is loose, worn-out, damaged, or incorrectly connected. Go to sub-stepb.
a.
Reconnect or replace the cable.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
b.
2.
Replace the sensor on site.
Replace the sensor.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 4.
a.
3.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
a.
4.
1.1.5 ALM-25620 Monitoring Device Power Supply ProblemDescription
This alarm is reported when the DC input to the monitoring device has a problem.
Parameters
Parameter Name Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Board Type Type of the monitoring device
Specific Problem Specific Problem of the alarm(DC Overvoltage, DC Undervoltage, DC Failure)
Impact on the System
Alarm Severity Alarm Impact
Major Some or all the monitoring functions of the monitoring device fail.If the monitoring device is an EDU, the devices carried on the EDU may be poweredoff. In this case, the ongoing services are disrupted.
System Actions
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
31 de 526 13/11/2012 9:15
-
If the monitoring device is an EDU, the devices carried on the EDU are powered off.
Possible Causes
The power cable for the monitoring device is faulty. For example, the power cable is looselyconnected, worn-out, or damage.
The input power malfunctions.
The corresponding monitoring device is faulty.
Procedure
Check for the correlated alarm of the base station on the M2000.
Check for the correlated alarm on the M2000.
25621 Power Supply DC Output Out of Range
Y => The correlated alarm exists. Go to sub-step b.
N => The correlated alarm does not exist. Go to step 2.
a.
Clear the correlated alarm with recommended actions.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
b.
1.
Check the power cable of the monitoring device on site.
Check whether the power cable between the monitoring device and the power supplydevice is normal.
Y => The power cable is functional and its connection is correct. Go to step 3.
N => The power cable malfunctions or its connection is incorrect. Go to sub-step b.
a.
Reconnect or replace the power cable.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
b.
2.
Check the input power of the monitoring device on site.
Check whether the input power voltage of the monitoring device is within the normalrange.
Y => The input power voltage is within the normal range. Go to step 4.
N => The input power voltage is beyond the normal range. Go to sub-step b.
a.
Contact the customer to set the input power voltage of the non-Huawei power supplydevice within the normal range.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 4.
b.
3.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
a.
4.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
32 de 526 13/11/2012 9:15
-
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
1.1.6 ALM-25621 Power Supply DC Output Out of RangeDescription
This alarm is reported when the DC output of the power system is out of range.
Parameters
Parameter Name Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Board Type Type of the monitoring device
Specific Problem Specific Problem of the alarm(DC Overvoltage, DC Undervoltage)
Impact on the System
Alarm Severity Alarm Impact
Major The DC output overvoltage may cause damage to the boards of the base station. Inthis case, the ongoing services carried on the boards are disrupted.The DC output undervoltage may lead to board power-off at the base station. In thiscase, the ongoing services carried on the boards are disrupted.
System Actions
None
Possible Causes
The AC input is out of range.
The PSU is faulty.
The alarm threshold setting is incorrect.
The battery charge is insufficient.
The corresponding monitoring device is faulty.
Procedure
Check for the correlated alarm on the M2000.
Check for the correlated alarm on the M2000:
25622 Mains Input Out of Range
25626 Power Module Abnormal
25711 Solar Array Fault
Y => The correlated alarm exists. Go to sub-step b.
N => The correlated alarm does not exist. Go to step 2.
a.
Clear the correlated alarm according to the relevant handling suggestions.b.
1.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
33 de 526 13/11/2012 9:15
-
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
Check the threshold of the power supply DC output out of range alarm of the power supply system.
Run the MML command LST PMU to query the settings for the power supply DC outputout of range alarm. Check whether the alarm threshold is correct according to theconfiguration planning.
Y => The alarm threshold is correct. Go to step 3.
N => The alarm threshold is incorrect. Go to sub-step b.
a.
Run the MML command MOD PMU to set the alarm threshold based on theconfiguration planning.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
b.
2.
Check the batteries on site.
Measure the voltage of the battery to check whether the voltage is lower than theundervoltage threshold obtained in step 2.
Y => The battery voltage is lower than the alarm threshold. Go to sub-step b.
N => The battery voltage is not lower than the alarm threshold. Go to step 4.
a.
Start the diesel generator to charge batteries.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 4
b.
3.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
a.
4.
1.1.7 ALM-25622 Mains Input Out of RangeDescription
This alarm is reported when the mains input is out of range.
Parameters
ParameterName Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
34 de 526 13/11/2012 9:15
-
Board Type Type of the monitoring device
Specific Problem Specific Problem of the alarm(AC Failure, AC Phase Loss, AC Overvoltage, ACUndervoltage)
Impact on the System
Alarm Severity Alarm Impact
Major In the case that AC failure or AC phase loss occurs:If batteries are configured, the NE is powered by batteries and operates normallyuntil the batteries are depleted. If Load Low Voltage Disconnected (LLVD) isenabled, the load is powered off when the LLVD threshold is reached. In this case,the ongoing services carried on the load are disrupted.In the case that AC undervoltage occurs:The DC output power decreases and therefore some boards are powered off. In thiscase, the life span of power system is shortened.In the case that AC overvoltage occurs:The power module may stop providing power. Some boards may be powered off. Inthis case, the life span of power system is shortened.
System Actions
None
Possible Causes
The alarm threshold setting is improper.
The AC Miniature Circuit Breaker (MCB) is switched off.The AC input power cable is faulty.
The AC power network or the power distribution is faulty.
The monitoring device is faulty.
Procedure
Locate the cause of the alarm on the M2000.
Locate the cause of the alarm based on the alarm detailed information.
If "Specific Problem" is "AC Overvoltage" or "AC Undervoltage", go to step 2.
If "Specific Problem" is "AC Failure" or "AC Phase Loss", go to step 3.
a.
1.
Check the threshold of the mains input out of range alarm.
Run the MML command LST PMU to query the mains input out of range alarm. Checkwhether the alarm threshold is proper according to the configuration planning.
Y => The threshold is proper. Go to step 4.
N => The threshold is improper. Go to sub-step b.
a.
Run the MML command MOD PMU to set the alarm threshold based on theconfiguration planning.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
b.
2.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
35 de 526 13/11/2012 9:15
-
N => The alarm is not cleared. Go to step 4.
Check the setting of the AC MCB on site.
Check whether the AC MCB is switched on.
Y => The AC MCB is switched on. Go to step 4.
N => The AC MCB is switched off. Go to sub-step b.
a.
Switch on the AC MCB.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 4.
b.
3.
Check the connections of the AC input power cable on site.
Check whether the AC input power cable is properly connected.
Y => The cable is properly connected. Go to step 5.
N => The cable is improperly connected. Go to sub-step b.
a.
Reconnect or replace the cable.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 5.
b.
4.
Check the AC power network and power distribution on site.
Check whether the AC power network and power distribution are functional.
Y => The AC power network and power distribution are functional. Go to step 6.
N => The AC power network or power distribution malfunctions. Go to sub-step b.
a.
Rectify the fault in the power supply for the base station.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 6.
b.
5.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
a.
6.
1.1.8 ALM-25623 Load Disconnected
Description
This alarm is reported when the load (including the RF unit) is powered off.
Parameters
Parameter Name Parameter Description
Cabinet No. Cabinet number of the monitoring device
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
36 de 526 13/11/2012 9:15
-
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Board Type Type of the monitoring device
Specific Problem Specific Problem of the alarm(Low Voltage, High Temperature, Remote Control)
Impact on the System
Alarm Severity Alarm Impact
Major The ongoing services carried on the load are disrupted.Warning The load is powered off remotely, and the ongoing services carried on the load are
disrupted.
System Actions
None
Possible Causes
The AC input is out of range.
The power module is faulty.
The solar array fails to provide the DC output.
The solar array is faulty.
The corresponding monitoring device is faulty.
Procedure
Check for the correlated alarm on the M2000.
Check for the correlated alarm on the M2000:
25622 Mains Input Out of Range
25626 Power Module Abnormal
25621 Power Supply DC Output Out of Range
25711 Solar Array Fault
Y => The correlated alarm exists. Go to sub-step b.
N => The correlated alarm does not exist. Go to step 2.
a.
Clear the correlated alarm according to the relevant handling suggestions.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
b.
1.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
a.
2.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
37 de 526 13/11/2012 9:15
-
1.1.9 ALM-25624 Battery Power Unavailable
Description
This alarm is reported when the batteries are depleted, the battery temperature is extremely high, or when thebatteries are powered off manually or remotely.
Parameters
ParameterName Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Board Type Type of the monitoring device
Specific Problem Specific Problem of the alarm(Low Voltage, High Temperature, Manual Stop, RemoteControl)
Impact on the System
Alarm Severity Alarm Impact
Major When the batteries are disconnected due to low voltage, the base station stopsworking and all related services are disrupted. The services are resumed only afterthe AC power supply is available.When the batteries are shut down at a high temperature, the battery charging ordischarging is stopped. If the AC power supply is unavailable, the base station stopsworking and the ongoing services are disrupted. If the AC power supply is available,the base station continues normal operation.
Warning The batteries cannot provide any power.
System Actions
None
Possible Causes
The mains input is out of range.
The power module is faulty.
The batteries are overheated.
The batteries are powered off manually.
The corresponding monitoring device is faulty.
Procedure
Check for the correlated alarm on the M2000.
Check for the correlated alarm on the M2000:
25622 Mains Input Out of Range
25626 Power Module Abnormal
25654 Battery Temperature Unacceptable
a.
1.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
38 de 526 13/11/2012 9:15
-
25655 Cabinet Air Outlet Temperature Unacceptable
Y => The correlated alarm exists. Go to sub-step b.
N => The correlated alarm does not exist. Go to step 2.
Clear the correlated alarm according to the relevant handling suggestions.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
b.
Check the battery button on the panel of the PMU on site.
Press the BAT ON button on the panel of the PMU and hold it for 5 to 10 seconds.Ensure that the batteries are powered on.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
a.
2.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
a.
3.
1.1.10 ALM-25625 Battery Current Out of RangeDescription
This alarm is reported when the battery current is out of range during charging and discharging.
Parameters
ParameterName Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Board Type Type of the monitoring device
SpecificProblem
Specific Problem of the alarm(Loop Broken, Charging Overcurrent, Discharging Imbalance,Discharging Overcurrent)
Impact on the System
Alarm Severity Alarm Impact
Major If overcurrent occurs during battery charging, the life span of batteries is shortened.The batteries cannot work because the battery loop is broken.The voltage of the batteries is imbalanced, which makes the backup power capacityof batteries insufficient.If overcurrent occurs during battery discharging, the power consumption of the base
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
39 de 526 13/11/2012 9:15
-
Alarm Severity Alarm Impact
station decreases and therefore the cell coverage area shrinks.
System Actions
None
Possible Causes
The batteries are not installed.
The power module is faulty.
The circuit breaker of the batteries is switched off or the battery contactor is switched off.
The batteries are faulty or worn-out.
The corresponding monitoring device is faulty.
Procedure
Check for the correlated alarm on the M2000.
Check whether one of the following correlated alarms is reported on the M2000:
25626 Power Module Abnormal
25624 Battery Power Unavailable
Y => A correlated alarm is reported. Go to sub-step b.
N => A correlated alarm is not reported.Go to step 2.
a.
Clear the correlated alarm with recommended actions.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
b.
1.
Locate the alarm cause on the M2000.
Locate the cause of alarm based on the alarm detailed information.
If "Specific Problem" is "Discharging Overcurrent", go to sub-step b
If "Specific Problem" is the other value, go to step 3.
a.
Raise the batter capacity or reduce the traffic load (for example,by shutting down anRF unit) based on the configuration plan.Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
b.
2.
Check the batteries onsite.
Check whether the batteries are installed.
Y => The batteries are installed. Go to step 4.
N => The batteries are not installed. Go to sub-step b.
a.
Check whether the batteries are required based on the configuration plan.
Y => The batteries are required. Go to sub-step c.
N => The batteries are not required. Go to sub-step d.
b.
3.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
40 de 526 13/11/2012 9:15
-
Install the batteries.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 4.
c.
Run the MML command RMV BATTERY to remove the batteries.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 4.
d.
Check the circuit breaker and fuse of the batteries on site.
Check whether the circuit breaker is switched off or the fuse of batteries isdisconnected.
Y => The circuit breaker is switched off or the fuse is disconnected. Go to sub-step b.
N => The circuit breaker is switched on and the fuse is connected. Go to step 5.
a.
Switch on the circuit breaker or replace the faulty fuse.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 5.
b.
4.
Check the difference between the battery voltage and the midpoint voltage of the battery group onsite.
Measure the battery voltage and the midpoint voltage of the battery group. Checkwhether their difference exceeds the threshold. If the battery voltage is larger than(midpoint voltage x 2 + 0.6) or lower than (midpoint voltage x 2 - 0.6), you can infer thatthe difference exceeds the threshold.
Y => The difference exceeds the threshold. Go to sub-step b.
N => The difference is lower than the threshold. Go to step 6.
a.
Inform the maintenance personnel to diagnose and clear the fault on site.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 6.
b.
5.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
a.
6.
1.1.11 ALM-25626 Power Module Abnormal
Description
This alarm is reported when the power module fails.
Parameters
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
41 de 526 13/11/2012 9:15
-
ParameterName Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
PSU Slot No. Slot number of the faulty power module
Board Type Type of the monitoring device
Specific Problem Specific Problem of the alarm(Power Module Fault, Power Module Protection, PowerModule Shutdown)
Impact on the System
Alarm Severity Alarm Impact
Major The power module is faulty. The faulty power module cannot provide the DC powerand cannot be recovered automatically. This fault weakens the DC power capabilityof the base station and may affect some services.The power module self-protection is being performed. The faulty power modulecannot output DC power supply, but it can be recovered automatically after the faultis rectified. The services may be affected for a while.
Warning The power module is shut down. The faulty power module operates normally, butcannot output DC power supply for a while because the power module is shut downmanually or the AC power supply is cut off. The services may be affected for awhile.
System Actions
None
Possible Causes
The cabinet is overheated.
The mains input is out of range.
The power module is faulty.
The corresponding monitoring device is faulty.
Procedure
Check for the correlated alarm on the M2000.
Check for the correlated alarm on the M2000:
25652 Cabinet Temperature Unacceptable
25654 Battery Temperature Unacceptable
25650 Ambient Temperature Unacceptable
25622 Mains Input Out of Range
Y => The correlated alarm exists. Go to sub-step b.
N => The correlated alarm does not exist. Go to step 2.
a.
Clear the correlated alarm according to the relevant handling suggestions.b.
1.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
42 de 526 13/11/2012 9:15
-
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
Replace the power module on site.
Replace the power module.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
a.
2.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
a.
3.
1.1.12 ALM-25628 AC Surge Protector FaultDescription
This alarm is reported when the AC surge protector of the base station is faulty.
Parameters
Parameter Name Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Board Type Type of the monitoring device
Impact on the System
Alarm Severity Alarm Impact
Major The AC surge protection function fails.
System Actions
None
Possible Causes
The cable connection between the AC surge protector and the monitoring device is loose or broken.
The AC surge protector fails.
The corresponding monitoring device is faulty.
Procedure
Check the cable connection between the surge protector and the monitoring device on site.1.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
43 de 526 13/11/2012 9:15
-
Check whether the cable between the surge protector and the monitoring device isfunctional and the connection is correct.
Y => The cable is functional and the connection is correct. Go to step 2.
N => The cable is loose, worn-out, damaged, or incorrectly connected. Go to sub-stepb.
a.
Reconnect or replace the cable.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
b.
Check the surge protector.
Check whether the alarm output port of the surge protector is closed.
Y => The alarm output port is closed. Go to step 3.
N => The alarm output port is open. Go to sub-step b.
a.
Replace the surge protector.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
b.
2.
Replace the monitoring device on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
a.
3.
1.1.13 ALM-25630 Power Module and Monitoring Module CommunicationFailure
Description
This alarm is reported when the monitoring module fails to communicate with the power module properly.
Parameters
Parameter Name Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
PSU Slot No. Slot number of the faulty power module
Board Type Type of the monitoring device
Impact on the System
Alarm Severity Alarm Impact
Major The power module is not installed or not in position. The faulty power module cannot
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
44 de 526 13/11/2012 9:15
-
Alarm Severity Alarm Impact
provide the DC power. This fault weakens the DC power capability of the basestation and may affect some services.The power module is in position, but its communication with the monitoring modulefails. The faulty power module is not in control of the monitoring module. The servicesmay be affected for a while.
System Actions
None
Possible Causes
The power module is not secure or not in position.
The monitoring module is not securely installed.
The power module is faulty.
The monitoring module is faulty.
Procedure
Check the power module on site.
Check whether the power module is installed in the slot of the subrack of the cabinetspecified in the alarm detailed information on site.
Y => The power module is installed. Go to sub-step b.
N => The power module is not installed. Go to sub-step c.
a.
Remove the power module, and then reinstall it properly.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
b.
Install the power module.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
c.
1.
Check the installation of the monitoring module on site.
Remove the monitoring module, and then reinstall it properly.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
a.
2.
Replace the power module on site.
Replace the power module.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 4.
a.
3.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
45 de 526 13/11/2012 9:15
-
Replace the monitoring module on site.
Replace the monitoring device.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
a.
4.
1.1.14 ALM-25631 Load Fuse Broken
Description
This alarm is reported when a load fuse is broken.
Parameters
Parameter Name Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Board Type Type of the monitoring device
Impact on the System
Alarm Severity Alarm Impact
Major The equipment associated with the broken fuse is powered off, which interrupts theongoing services carried by the equipment.
System Actions
None
Possible Causes
The load fuse is broken or not in position.
Procedure
Check the load fuse on site.
Check whether the load fuse is installed.
Y => The load fuse is installed. Go to sub-step c.
N => The load fuse is not installed. Go to sub-step b.
a.
Install a spare fuse.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to sub-step c.
b.
Locate the faulty fuse by checking the output voltage of the power system, the solarcontroller, or the equipment which is powered off, and then replace the load fuse.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
c.
1.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
46 de 526 13/11/2012 9:15
-
N => The alarm is not cleared. Contact Huawei Customer Service Center.
1.1.15 ALM-25632 Battery Cabin Heater Fault
Description
This alarm is reported when the heater of the battery cabin is faulty.
Parameters
Parameter Name Parameter Description
Cabinet No. Cabinet number of the monitoring device
Subrack No. Subrack number of the monitoring device
Slot No. Slot number of the monitoring device
Board Type Type of the monitoring device
Impact on the System
Alarm Severity Alarm Impact
Major The performance of batteries is degraded and the life span is shortened.
System Actions
None
Possible Causes
The AC input power cable of the heater is not properly connected.
The heater is faulty.
The temperature sensor in the battery cabin is faulty.
Procedure
Check the battery temperature and ambient temperature on the M2000.
After the AC power supply for the heater operates normally for one hour, run the MMLcommand DSP PMU to query the battery temperature, and run the MML commandDSP EMU to query the ambient temperature.
Check whether both the battery temperature and the ambient temperature are lowerthan -20C.
Y => Both the battery temperature and the ambient temperature are lower than -20C.Go to sub-step b.
N => The battery temperature or the ambient temperature is not lower than -20C. Goto step 2.
a.
Replace the heater on site.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 2.
b.
1.
Check the Miniature Circuit Breaker (MCB) state and connections of the AC input power cable ofthe heater on site.
2.
Fault Management http://localhost:7890/printtopics.html?time=Tue Nov 13 2012 09:15:0...
47 de 526 13/11/2012 9:15
-
Check whether the AC input power cable of the heater is functional, and check whetherthe MCB of the heater is switched on.
Y => The cable is functional and the MCB is switched on. Go to step 3.
N => The cable is loose, worn-out, damaged, incorrectly connected, or the MCB is notswitched on. Go to sub-step b.
a.
Reconnect or replace the cable, or switch on the MCB.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm is not cleared. Go to step 3.
b.
Replace the temperature sensor in the battery cabin on site.
Replace the sensor.
Check whether the alarm is cleare