Page 1: POLYBASE R+ S - Fransylv~Polybase_R__S_-_TDS.pdf · POLYBASE R+ S 3 in 1 prefabricated panel Advantageous thermal value* For cold applied or SBS bitumen system Flameless VOC free

POLYBASE R+ S 3 in 1 prefabricated panel

Advantageous thermal value*For cold applied or SBS bitumen systemFlamelessVOC freeQuick and easy installationIncreases productivity on jobsite

value of panel according to specificationsMonolithic panel

ADVANTAGES ACKNOWLEDGMENT

T. 450.477.4423 1.800.363.2307 FRANSYL.COM

*The use of a 9’’ wide S/S type tape or self-adhesiveunderface and sanded surface tape is mandatory.

Note: If used with a self-adhesive tape, Lexcor MULTIGRIP Primeris required and the panel must be covered with a cap sheetwithin the same day.

THICKNESS OF POLYBASE R+ SType HR (Type I) Type THR (Type II)

R-11.5 3’’ 2 3/4’’

R-13.5 3 1/2’’ 3 1/4’’’

R-14.5 3 3/4’’ 3 1/2’’

R-15.5 4’’ 3 3/4’’

R-17.5 4 1/2’’ 4 1/4’’

R-19.5 5’’ 4 3/4’’

«R» Insulating Value

POLYBASE R+ S

26418

The thermal value of the expanded polystyrene is 100% guaranteed

1 1/2’’ overlapping protection strip *

95 g underlayment membrane of 2.2 mm thick,consisting of a fiberglass reinforcement with athermofusible underface and a sanded surface OR180 g underlayment membrane of 2.2 mm thick,consisting of a polyester reinforcement with athermofusible underface and a sanded surface

double-sided 3" self-adhesive overlapping strip

1/2" (12.70 mm) composite panel, factory lamina-ted on both faces of a fireproof fibreglass sheet

Fransyl Izolon Insulation

Meets Novoclimat requirements

Page 2: POLYBASE R+ S - Fransylv~Polybase_R__S_-_TDS.pdf · POLYBASE R+ S 3 in 1 prefabricated panel Advantageous thermal value* For cold applied or SBS bitumen system Flameless VOC free

½" (12.70 MM) COMPOSITE PANEL, FACTORY LAMINATED ON BOTH FACES OF A FIRE RETARDANT FIBREGLASS SHEET

Thermal resistance R-2.5(ASTM C518 C177), (RSI-0.53)

Water vapor permeability < 1.00 perm(ASTM E96) (85 ng/Pa s m2)

Compressive strength(ASTM D 1621) 620 kPa10% deformation (90 lbs / in²)

Tensile strength > 35 kPa(ASTM D 1623) (5.07 lbs / in2)

Water absorption < 1%,(ASTM C 209, ASTM D 2842) < 3,5%

Density 2 lbs / ft3

(ASTME D 1622) (32.04 kg/m3)

Smoke developement 50-170(ASTM E84), evaluation on a 10 min. period

Flame spread 40-60(ASTM E84), evaluation on a 10 min. period

POLYBASE R+ SSPECIFICATIONSDIMENSIONS

ROOFING SYSTEMS

T. 450.477.4423 1.800.363.2307 FRANSYL.COM

Cold bending in lower temperatures (ASTM D6163) Successful, °C (°F)

Longitudinal and transversal tensile strength at breakage (ASTM D6163) Successful, kN/m (lbf/in)

Elongation at breakage Successful, N (lbf)

Longitudinal and transversal elongation at breakage (ASTM D6163) Successful %

Longitudinal and transversal tear strength (ONGC-37.56-M) Successful, N (lbf)

Longitudinal and transversal resistance to lap joint (ONGC-37.56-M), 5J @ 23°C Successful, kN/m (lbf/in)

Width x length: 36’’ x 96’’ (914 mm x 2438 mm)

Thickness of shiplap edge*: 2’’ to 4 1/2’’ (51 mm to 114 mm)

Shiplap: 5/8’’ (16 mm)*1Dimensions may vary ± 2% *2Other dimensions available upon request

95 G MEMBRANE OF 2.2 MM THICK, CONSISTING OFA FIBERGLASS REINFORCEMENT WITH A THERMOFUSIBLEUNDERFACE AND SANDED SURFACE, INCLUDING ADOUBLE-SIDED 3’’ SELF-ADHESIVE OVERLAPPING STRIP

180 G MEMBRANE OF 2.2 MM THICK, CONSISTING OFA POLYESTER REINFORCEMENT WITH A THERMOFUSIBLEUNDERFACE AND SANDED SURFACE, INCLUDING ADOUBLE-SIDED 3’’ SELF-ADHESIVE OVERLAPPING STRIP

OR

Installation:

Option 1: Mechanical fastening

Option 2: Adhesive application(Contact your sales rep. for all details)

for 1/2’’ (12.70 mm) thickness

Polybase R+ S Panel with Cap Sheet :UL Class C Fully Adhered (ref. TGFUC.R16778)CAN/ULC-S107

POLYBASE R+ SHR

(Type I)

Thermal resistance R-3.7(ASTM C518 C177) (RSI-0.65)1’’ (25 mm) thickness

Water vapour permability 5.25 perm(ASTM E96), 1’’ (25 mm) thickness (300 ng/Pa·s·m²)

Compressive strength 80 kPa(ASTM D1621) (11.64 lbs/in²)1 ½ ’’ (38 mm) thickness

Flexural strength 170 kPa(ASTM C 203) (24.78 lbs/in²)1 ½ ’’ (38 mm) thickness

Water absorption (ASTM D 2842) 6%1 ½ ’’ (38 mm) thickness

Density 1 lb/ft³(ASTM D 1621) (16.01 kg/m³)

Limiting Oxygen Index 24%(ULC S-701) % minimum

1.5%Dimensional stability (ASTM D 2126)% maximum linear change

THR(Type II)

R-4(RSI-0.7)

3.5 perm(200 ng/Pa·s·m²)

120 kPa(17.46 lbs/in²)

240 kPa(34.97 lbs/in²)

4%

1.25 lb/ft³(20.01 kg/m³)

24%

1.5%

HD(Type II)

R-4,17(RSI-0.73)

2.25 perm(130 ng/Pa·s·m²)

160 kPa(23.3 lbs/in²)

300 kPa(43.71 lbs/in²)

3%

1.5 lb/ft³(24.02 kg/m³)

24%

1.5%

THD(Type III)

R-4,2(RSI-0.74)

2.25 perm(130 ng/Pa·s·m²)

210 kPa(30.6 lbs/in²)

300 kPa(43.71 lbs/in²)

2%

2 lb/ft³(32.03 kg/m³)

24%

1.5%

Important note: It is possible that blisters are formed in the membrane when the temperature increases; this has no impact on the performance and adhesion of the membrane on the panel. Blisters under the mem-brane will fade upon cooling of the panel.