Download - Quadrox Adults
8/2/2019 Quadrox Adults
http://slidepdf.com/reader/full/quadrox-adults 1/8
QUADROX
OXYGENATOR SYSTEM
8/2/2019 Quadrox Adults
http://slidepdf.com/reader/full/quadrox-adults 3/8
LEADING THE WAY
QUADROX OXYGENATORS
MAQUET – THE GOLD STANDARD
The innovative technologies within our QUADROX oxy-
genation system offer exceptional features for state-of-
the-art perfusion. Engineered for minimal priming volumeand foreign surface contact. The QUADROX oxygenation
system is a proven concept. As oxygenation technology
becomes more sophisticated, QUADROX is leading the way
with performance and versatility for today‘s perfusionists. Its
unique diamond design and special flow geometry provide
clinical benefits which the perfusionist will appreciate. Its
functional flexibility is optimized for ease of use. The QUADROX
is at your side, safe, and dependable: an unbeatable classic.
Exceptionally low pressure drop
Particularly low priming volume
Minimized foreign surface contact Excellent O2 and CO2 transfer performance
Highly efficient heat exchanger
Optimum surface refinement with standard
SAFELINE COATING
QUADROX D also available with BIOLINE COATING
MAQUET – The Gold Standard.
| The Gold Standard | Cardiovascular | QUADROX |
8/2/2019 Quadrox Adults
http://slidepdf.com/reader/full/quadrox-adults 4/8
| QUADROX | Cardiovascular ||
INNOVATIVE DESIGN
COMMITTED TO MEETING INDIVIDUAL pATIENT NEEDS
Suerior fiber technology: The QUADROX D with diffusion
membrane: Its tight hollow-fiber membrane made of poly-
methylpentene eliminates plasma leaks. It effectively prevents
the formation of microbubbles. QUADROX D provides the same
outstanding handling characteristics and performance data of
the QUADROX oxygenator with its microporous membrane.
Individual ways to enhanced biocomatibility: For opti-
mum blood handling, both QUADROX and QUADROX D are
available with SAFELINE COATING. Our standard SAFELINE
COATING minimizes transmembrane pressure increases with
exceptional reliability. Our long established BIOLINE COATING
is available for QUADROX D and shows a significant improved
hemocompatibility. Thrombocyte adhesion and activation are
considerably reduced with BIOLINE COATING.
Heat Exchange performance
QUADROX + QUADROX D
pressure Dro
QUADROX + QUADROX D
Oxygen Transfer
QUADROX + QUADROX D
0 1 2 3 4 5 6 7
500
450
400
350
300
250
200
150
100
50
0
C O 2
T r a n s f e r · m l / m i n
gas tobloodow
blood ow (l/min)
2:1
1:1
0,5: 1
Carbon Dioxide Transfer
QUADROX
0 1 2 3 4 5 6 7
500
450
400
350
300
250
200
150
100
50
0
C O 2
T r a n s f e r · m l / m i n
gas tobloodow
blood ow (l/min)
2:1
1:1
0,5:1
Carbon Dioxide Transfer
QUADROX D
Reference: ISO 7199 standard. Gastransfer
ra tes and p re ssur e d rop a t 37° C
8/2/2019 Quadrox Adults
http://slidepdf.com/reader/full/quadrox-adults 5/8
| Cardiovascular | QUADROX |
Membrane surface without SAFELINE treatment: Un-
coated membrane with depositions potentially leading to
high pressure drop phenomena.
A CLASSIC CASE OF FLEXIBILITY
QUADROX SUppORTS YOUR CHOICE
QUADROX membrane surface with SAFELINE treatment:
The advantage of the SAFELINE treatment under the electron
microscope: significant reduction in surface deposition on the
QUADROX membrane. The typical transmembrane pressure
increase is minimized consistently.
Technical Data QUADROX QUADROX D
Blood flow rate 0.5 - 7 l/m 0.5 - 7 l/m
Priming volume 250 ml 250 ml
Effective sur face area gas exchange 1.8 m2 1.8 m2
Material of microporous membrane Polypropylene Polymethylpentene
Effective sur face area heat exchange 0.6 m2 0.6 m2
Material of heat exchange capillary Polyurethane Polyurethane
8/2/2019 Quadrox Adults
http://slidepdf.com/reader/full/quadrox-adults 6/8
| QUADROX | Cardiovascular ||
CLEARLY REFINED
VENOUS HARDSHELL CARDIOTOMY RESERVOIR VHK
Refined in every detail, the VHK meets the demands of
operating and perfusion techniques in the field of open-heart
surgery. It offers a minimum operating volume of 300 ml and
a capacity of 4200 ml. Its volume scale is easily readable
from all sides ensuring precise measurability, even for small
amounts of blood. A transparent blue cover permits viewing
the interior filter unit.
Designed for otimum ositioning flexibility, the VHKallows tubing lengths to be reduced and priming volume to
be minimized. The QUADROX rotates 360° under the VHK
reservoir and can be locked into any position. The VHK venous
inlet also rotates 360° independently. The reservoir and oxy-
genator units can be separated in seconds. Optionally, a
sealed version of the VHK is of fered to enable the application
of vacuum to assist venous drainage (VAVD) during extracor-
poreal circulation or for post-operative thoracic drainage. The
sealed version features a pressure relief valve.
Technical Data
Minimum operating volume 300 ml
Maximum capacity 4200 ml
Maximum blood flow:
- venous f ilter 7 l/min
- cardiotomy filter 5 l/min
- combined 7 l/min
Defoamer Polyurethane foam
Anti foaming a gent Medica l a nt ifoaming C
Cardiotomy filter 40 µm
Filter Polyester
VHK (profile)
8/2/2019 Quadrox Adults
http://slidepdf.com/reader/full/quadrox-adults 7/8
| Cardiovascular | QUADROX |
product Code No. Quantity
QUADROX HMO 2030 4 pcs./box
QUADROX D HMOD 2030 4 pcs./box
QUADROX D BIOLINE coated BEQ-HMOD 2030 1 pc./box
VHK VHK 200 0 1 p c. /box
VHK s ea led VHK 2001 1 p c. /box
QUADROX and VHK VKMO 2030 1 pc./box
QUADROX D and VHK VKMOD 2030 1 pc./box
QUADROX and VHK sealed VKMO 2031 1 pc./box
QUADROX D and VHK sealed VKMOD 2031 1 pc./box
Holder for single QUADROX, QUADROX D Holder for VHK, VKMO, and VKMOD Holder for VHK (for ICU)
Holder for:
QUADROX 01 60 62
VHK, VKMO, and VKMOD 01 60 60
VHK ( fo r I CU) 01 60 70
8/2/2019 Quadrox Adults
http://slidepdf.com/reader/full/quadrox-adults 8/8
MAQUET Cardiopulmonary AG
Hechinger Straße 38
D-72145 Hirrlingen, Germany
Phone: +49 (0) 7478 921-0
Fax: +49 (0) 7478 921-100
www.maquet.com
For local contact:
Please visit our website
www.maquet.com
GETINGE Group is a leading global provider of equipment and
systems that contribute to quality enhancement and cost efficiency
within healthcare and life sciences. Equipment, service and tech-
nologies are supplied under the brands ArjoHuntleigh for patient
handling and hygiene, disinfection, DVT prevention, medical beds,
therapeutic surfaces and diagnostics, GETINGE for infection control
and prevention within healthcare and life science and M AQUET for
Surgical Workplaces, Cardiovascular and Critical Care.