8/2/2019 Quadrox Adults

http://slidepdf.com/reader/full/quadrox-adults 1/8

QUADROX

OXYGENATOR SYSTEM

8/2/2019 Quadrox Adults

http://slidepdf.com/reader/full/quadrox-adults 2/8

8/2/2019 Quadrox Adults

http://slidepdf.com/reader/full/quadrox-adults 3/8

LEADING THE WAY

QUADROX OXYGENATORS

MAQUET – THE GOLD STANDARD

The innovative technologies within our QUADROX oxy-

genation system offer exceptional features for state-of-

the-art perfusion. Engineered for minimal priming volumeand foreign surface contact. The QUADROX oxygenation

system is a proven concept. As oxygenation technology

becomes more sophisticated, QUADROX is leading the way

with performance and versatility for today‘s perfusionists. Its

unique diamond design and special flow geometry provide

clinical benefits which the perfusionist will appreciate. Its

functional flexibility is optimized for ease of use. The QUADROX

is at your side, safe, and dependable: an unbeatable classic.

  Exceptionally low pressure drop

  Particularly low priming volume

  Minimized foreign surface contact  Excellent O2 and CO2 transfer performance

  Highly efficient heat exchanger

  Optimum surface refinement with standard

SAFELINE COATING

  QUADROX D also available with BIOLINE COATING

MAQUET – The Gold Standard.

| The Gold Standard | Cardiovascular  | QUADROX |

8/2/2019 Quadrox Adults

http://slidepdf.com/reader/full/quadrox-adults 4/8

| QUADROX | Cardiovascular  ||

INNOVATIVE DESIGN

COMMITTED TO MEETING INDIVIDUAL pATIENT NEEDS

Suerior fiber technology: The QUADROX D with diffusion

membrane: Its tight hollow-fiber membrane made of poly-

methylpentene eliminates plasma leaks. It effectively prevents

the formation of microbubbles. QUADROX D provides the same

outstanding handling characteristics and performance data of

the QUADROX oxygenator with its microporous membrane.

Individual ways to enhanced biocomatibility: For opti-

mum blood handling, both QUADROX and QUADROX D are

available with SAFELINE COATING. Our standard SAFELINE

COATING minimizes transmembrane pressure increases with

exceptional reliability. Our long established BIOLINE COATING

is available for QUADROX D and shows a significant improved

hemocompatibility. Thrombocyte adhesion and activation are

considerably reduced with BIOLINE COATING.

Heat Exchange performance

QUADROX + QUADROX D

pressure Dro

QUADROX + QUADROX D

Oxygen Transfer

QUADROX + QUADROX D

0 1 2 3 4 5 6 7

500

450

400

350

300

250

200

150

100

50

0

   C   O   2

   T  r  a  n  s   f  e  r  ·  m   l   /  m   i  n

gas tobloodow

blood ow (l/min)

2:1

1:1

0,5: 1

Carbon Dioxide Transfer

QUADROX

0 1 2 3 4 5 6 7

500

450

400

350

300

250

200

150

100

50

0

   C   O   2

   T  r  a  n  s   f  e  r  ·  m   l   /  m   i  n

gas tobloodow

blood ow (l/min)

2:1

1:1

0,5:1

Carbon Dioxide Transfer

QUADROX D

Reference: ISO 7199 standard. Gastransfer 

 ra tes and p re ssur e d rop a t 37° C

8/2/2019 Quadrox Adults

http://slidepdf.com/reader/full/quadrox-adults 5/8

| Cardiovascular  | QUADROX |

Membrane surface without SAFELINE treatment: Un-

coated membrane with depositions potentially leading to

high pressure drop phenomena.

 A CLASSIC CASE OF FLEXIBILITY

QUADROX SUppORTS YOUR CHOICE

QUADROX membrane surface with SAFELINE treatment:

The advantage of the SAFELINE treatment under the electron

microscope: significant reduction in surface deposition on the

QUADROX membrane. The typical transmembrane pressure

increase is minimized consistently.

Technical Data QUADROX QUADROX D

Blood flow rate 0.5 - 7 l/m 0.5 - 7 l/m

Priming volume 250 ml 250 ml

Effective sur face area gas exchange 1.8 m2 1.8 m2

Material of microporous membrane Polypropylene Polymethylpentene

Effective sur face area heat exchange 0.6 m2 0.6 m2

Material of heat exchange capillary Polyurethane Polyurethane

8/2/2019 Quadrox Adults

http://slidepdf.com/reader/full/quadrox-adults 6/8

| QUADROX | Cardiovascular  ||

CLEARLY REFINED

 VENOUS HARDSHELL CARDIOTOMY RESERVOIR VHK

Refined in every detail, the VHK meets the demands of

operating and perfusion techniques in the field of open-heart

surgery. It offers a minimum operating volume of 300 ml and

a capacity of 4200 ml. Its volume scale is easily readable

from all sides ensuring precise measurability, even for small

amounts of blood. A transparent blue cover permits viewing

the interior filter unit.

Designed for otimum ositioning flexibility, the VHKallows tubing lengths to be reduced and priming volume to

be minimized. The QUADROX rotates 360° under the VHK

reservoir and can be locked into any position. The VHK venous

inlet also rotates 360° independently. The reservoir and oxy-

genator units can be separated in seconds. Optionally, a

sealed version of the VHK is of fered to enable the application

of vacuum to assist venous drainage (VAVD) during extracor-

poreal circulation or for post-operative thoracic drainage. The

sealed version features a pressure relief valve.

Technical Data

Minimum operating volume 300 ml

Maximum capacity 4200 ml

Maximum blood flow:

- venous f ilter 7 l/min

- cardiotomy filter 5 l/min

- combined 7 l/min

Defoamer Polyurethane foam

 Anti foaming a gent Medica l a nt ifoaming C

Cardiotomy filter 40 µm

Filter Polyester

VHK (profile)

8/2/2019 Quadrox Adults

http://slidepdf.com/reader/full/quadrox-adults 7/8

| Cardiovascular  | QUADROX |

product Code No. Quantity

QUADROX HMO 2030 4 pcs./box

QUADROX D HMOD 2030 4 pcs./box

QUADROX D BIOLINE coated BEQ-HMOD 2030 1 pc./box

 VHK VHK 200 0 1 p c. /box

 VHK s ea led VHK 2001 1 p c. /box

QUADROX and VHK VKMO 2030 1 pc./box

QUADROX D and VHK VKMOD 2030 1 pc./box

QUADROX and VHK sealed VKMO 2031 1 pc./box

QUADROX D and VHK sealed VKMOD 2031 1 pc./box

Holder for single QUADROX, QUADROX D Holder for VHK, VKMO, and VKMOD Holder for VHK (for ICU)

Holder for:

QUADROX 01 60 62

 VHK, VKMO, and VKMOD 01 60 60

 VHK ( fo r I CU) 01 60 70

8/2/2019 Quadrox Adults

http://slidepdf.com/reader/full/quadrox-adults 8/8

MAQUET Cardiopulmonary AG

Hechinger Straße 38

D-72145 Hirrlingen, Germany

Phone: +49 (0) 7478 921-0

Fax: +49 (0) 7478 921-100

[email protected]

www.maquet.com

For local contact:

Please visit our website

www.maquet.com

GETINGE Group is a leading global provider of equipment and

systems that contribute to quality enhancement and cost efficiency

within healthcare and life sciences. Equipment, service and tech-

nologies are supplied under the brands ArjoHuntleigh for patient

handling and hygiene, disinfection, DVT prevention, medical beds,

therapeutic surfaces and diagnostics, GETINGE for infection control

and prevention within healthcare and life science and M AQUET for

Surgical Workplaces, Cardiovascular and Critical Care.

CP10183

Subsidiaries

USA:

  MAQUET Cardiovascular LLC

170 Baytech Drive

San Jose, CA 95134

Phone: 1-888-880-2874

Fax: 1-888-899-2874

www.maquet.com