dp study
DESCRIPTION
DP StudyTRANSCRIPT
Sheet1VWTA 020 BOILER DP STUDYDate:06.08.2013Air Box Pressure mmwcAerofoil flow mmwcBefore Aerofoil mmwcPA Header mmwcFurnace Pressure mmwc1 st Compartment2 nd Compartment3 rd Compartment4 th Compartment1 st Compartment8029104720-310036126740-412043152740-414048172680-42 nd Compartment8030103650-4.410040126750-3.812046149750-414052176700-43 rd Compartment8034107700-3.810042132740-4.212048150750-4.214053182690-3.84 th Compartment8035102720-310043132730-412048154750-414059177680-2.31 & 2 Compartment808056115720-3.810010074158740-512012080178750-3.514014085196630-52 & 3 Compartment808062120740-410010076156740-412012083178750-314014092208750-4.73 & 4 Compartment808065120720-3.810010078152740-312012088180740-314014096205760-3.51,2,&3 Compartment80808090130690-3100100100120182700-3.6120120120128206720-3.7140140140145234730-32,3 & 4 Compartment80808096142690-2.3100100100122182710-3120120120128212720-3140140140150240740-3.51,2,3 & 4 Compartment80808080143170660-3.3100100100100168202660-3120120120120196238670-3.2140140140140225280680-3.2
Sheet2
Sheet3