dr. arnd schmücker, peter schwengler tgls, pipelines competence centre paris 12. september 2007

12
GAS CAMERA Mobile imaging system to detect methane plumes from distances between 0 m and at least 100 m Dr. Arnd Schmücker, Peter Schwengler TGLS, Pipelines Competence Centre Paris 12. September 2007

Upload: claral

Post on 30-Jan-2016

64 views

Category:

Documents


0 download

DESCRIPTION

GAS CAMERA Mobile imaging system to detect methane plumes from distances between 0 m and at least 100 m. Dr. Arnd Schmücker, Peter Schwengler TGLS, Pipelines Competence Centre Paris 12. September 2007. Overview. Project Goal Development Status Next Steps. 1. Project Goals. Vision: - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

GAS CAMERA

Mobile imaging system to detectmethane plumes from distancesbetween 0 m and at least 100 m

Dr. Arnd Schmücker, Peter Schwengler

TGLS, Pipelines Competence Centre

Paris 12. September 2007

Page 2: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 2

Project Goal

Development

Status

1. Next Steps

Overview

Page 3: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 3

1. Project GoalsVision:Mobile imaging system to detectmethane plumes from distancesbetween 0 m and at least 100 m

Main Demands: Removable Low energy consumtion High measure responsivity Real time visualisation Easy handling All-purpose

Page 4: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 4

1. Project Goal: „Gas Camera“ Specification

Specification Overall RequirementsTarget gas Methane CH4Max. weight 25 kgDetection range 100 ppm mLeakage rate < 100 L/h (25 L/h under ideal conditions)Locality Pipelines and stations, open and closed; explosion

proofVisualisation Overlay of results with real video imageSpatial resolution min. 128 x 128 pixelService staff Work men with special trainingWeather condition All weather conditions ; -20°C up to 40°C Field of regard 100 m x 20 mFrame rate > 1/sEnergy Battery; min. 4 hours autonomic; < 100 W

(including computer)Max. dimensions 0,5 m x 0,3 m x 0,25 m

Page 5: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 5

2. Development Basis : IR-Spektroskopie• Spectrometer

• Scanner

• Video System

• PC Control Unit

Page 6: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 6

2. Development Basis: Interference Filter Principle

700 800 900 1000 1100 1200 1300 14000

0.2

0.4

0.6

0.8

Wavenumber (cm-1)

Filt

er T

rans

mis

sion

/Abs

orba

nce

Filter 1(Target Gas)

Filter 2(Reference)

Page 7: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 7

Calibration Unit

Filter Wheel

IR Lens

Detector Array

2. Development: Principe and Prototype

Page 8: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 8

3. Hardware-Status: Detector-Array

Frame GrabbersVideoCamera

• Full functionality implemented in

prototype system

Page 9: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 9

3. Software-Status

Video Image

Gas Imageoverlay

Control

Page 10: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 10

Measurement of Methane

Air temperature : 15.1 oCWall temperature : 18.3 oCDistance : 6 mRelease rate : 340 L/h

3. Measurements

Page 11: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 11

Measurement of Methane

Air temperature : 17.2 oCWall temperature : 21.2 oCDistance : 14 mRelease rate : 34 L/h

3. Measurements

Page 12: Dr. Arnd Schmücker, Peter Schwengler  TGLS, Pipelines Competence Centre Paris 12. September 2007

Page 12

4. Status and Next Steps Automatic calibration unit Gigabit ethernet “Frame Grabbers” implementation System control via ethernet Control-Electronic development Video image background and gas image overlay Control and anlysis software development Basic-Detector-Array development Detector-Array implementation Market study Milestone I (Prototype finished): October 2007 Field trials under real conditions