draft Proposal for MICE proposal Layout overall edition: Blondel & Kaplan. Executive Summary 1 page - PowerPoint PPT PresentationTRANSCRIPT
Alain Blondel
draft Proposal for MICE proposal Layoutoverall edition: Blondel & Kaplan
Executive Summary 1 pagetable of contents 1 pagefull author list -------!!!!!! 2 pagesresponsibility structure 1 page
1. General motivation (S.Geer & K. Long) 2. Cooling (Kaplan) 3. The International Muon Ionization Cooling Experiment (Blondel, Lombardi, Palmer) 3.1 Layout and principle 3.2 Experiments to be performed 3.3 Expected performance and statistical precision 3.4 Systematic errors and resulting requirements 3.5 possible development of the experiment in time 8 pages
Alain Blondel
T.O.F. IIIT.O.F. IIIPrecise timingPrecise timing
Electron IDElectron IDEliminate muons that decay Eliminate muons that decay
Tracking devices: Tracking devices: He filled TPC-GEM and/or Sci-Fi trackerHe filled TPC-GEM and/or Sci-Fi trackerMeasurement of momentum, angles and positionMeasurement of momentum, angles and position
T.O.F. I & IIT.O.F. I & IIPion /muon Pion /muon IDIDprecise precise timingtiming
10% cooling of 200 MeV muons requires ~ 20 MV of RF single particle measurements =>
measurement precision can be as good as out/ in ) = 10-3
201 MHz RF cavities
Liquid H2 absorbersor LiH ?
SC Solenoids;Spectrometer, focus pair, compensation coil
new drawing needed with new magnetic configand matching coils in!
Alain Blondel
STEP I:
STEP II
STEP III
STEP IV
STEP V
STEP VIIfinal results
solenoid/bucking
Solenoid or Bucking?
solenoid/buckingvary momentum and betavary absorber thicknessvary absorber material
Alain Blondel
Pictures explaining the operation of MICEand the quantities to be measured
was done with 88 MHz, PATH, no spectro match, etc… -> need actual MICE
-> Palmer, (ICOOL)
Lombardi(PATH)one of the two is enough
4.70E-03
4.75E-03
4.80E-03
4.85E-03
4.90E-03
4.95E-03
0 2 4 6 8 10 12 14 16
z [m]
tran
sver
se e
mit
tan
ce [
m r
ad]
ICOOL
Alain Blondel
spectrometer performance by P. Janot. No noise, inefficiencies, ad hoc fortran code.
do this with ‘official GEANT4’ + Bkg, efficiency, etc.. One detector choice is enough!
+ simulations in the particle ID (downstream)
G-4-MICE
Alain Blondel
Systematic effects…
in cooling:-- need for magnetic measurements was identified (see JM Rey)
justification for specs (10-3 measurements?) is missing
-- thickness of absorbers (how will this be measured)
-- RF field monitoring ? in measurement-- tracking errors, tof systematics…
-- others?