OHIO BRASS – AIKEN, SC DECEMBER 2010 HUBBELL ® Power Systems ® Section 204 DynaVar ® Arresters IEC Line Discharge Classes 2, 3, 4 & 5 Web: http://www.hubbellpowersystems.com E-mail: [email protected] Printed in USA RGS 1M

Upload: lamlien

Post on 27-Jul-2018

225 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-1

HUBBELL®

Power Systems

®

Section

204

DynaVar ®Arresters

IEC Line Discharge Classes 2, 3, 4 & 5

Web: http://www.hubbellpowersystems.comE-mail: [email protected]

Printed in USA

RGS 1M

Page 2: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-2®

NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice.

Table of ContentsPage

Introduction ............................................................................................................................................... 3Arrester Application ................................................................................................................................... 4Ohio Brass General Arrester Information .................................................................................................. 5

POLYMER HOUSED ARRESTERS (Type PVI-LP and PVN) .................................................................. 8PVI-LP (Class 2) ......................................................................................................................................... 9

PVI-LP Ordering System ....................................................................................................................... 9PVI-LP Protective Characteristics ....................................................................................................... 10PVI-LP Physical Characteristics.......................................................................................................... 10PVI-LP Mounting Arrangements ......................................................................................................... 11PVI-LP Terminals ................................................................................................................................. 11

PVN (Class 3) ........................................................................................................................................... 12PVN Ordering System ......................................................................................................................... 12PVN Protective Characteristics ........................................................................................................... 13PVN Mounting Arrangements ............................................................................................................. 13PVN Physical Characteristics .............................................................................................................. 14PVN Terminals ..................................................................................................................................... 14

POLYMER HOUSED ARRESTERS (Type PH3 & PH4) ........................................................................ 15PH3 & PH4 Ordering System .............................................................................................................. 16

PH3 (Class 3) ........................................................................................................................................... 18PH3 Protective Characteristics ........................................................................................................... 19PH3 Physical Characteristics .............................................................................................................. 20PH3 Pollution Levels ........................................................................................................................... 22

PH4 (Class 4) ........................................................................................................................................... 24PH4 Protective Characteristics ........................................................................................................... 25PH4 Physical Characteristics .............................................................................................................. 26PH4 Pollution Levels ........................................................................................................................... 28

PORCELAIN HOUSED ARRESTERS (Type H3, H4 & H5) ................................................................... 30Porcelain Ordering System ................................................................................................................. 31

H3 (Class 3) ............................................................................................................................................. 33H3 Protective Characteristics ............................................................................................................. 34H3 Physical Characteristics ................................................................................................................ 35H3 Pollution Levels ............................................................................................................................. 37

H4 (Class 4) ............................................................................................................................................. 38H4 Protective Characteristics ............................................................................................................. 39H4 Physical Characteristics – Light & Medium Pollution Levels ......................................................... 40H4 Physical Characteristics – Heavy & Very Heavy Pollution Levels .................................................. 42H4 Pollution Levels ............................................................................................................................. 44

H5 (Class 5) ............................................................................................................................................. 46H5 Protective Characteristics ............................................................................................................. 46H5 Physical Characteristics ............................................................................................................... 46

Warranty - MaterialHubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such term is defined in the Uniform Commercial Code) and to be free from defects in material and workmanship. Buyer must notify the Company promptly of any claim under this warranty. The Buyer's exclusive remedy for breach of this warranty shall be the repair or replacement, F.O.B. factory, at the Company's option, of any product defective under the warranty which is returned to the Company within one year from the date of shipment. NO OTHER WARRANTY, WHETHER EXPRESS OR ARISING BY OPERATION OF LAW, COURSE OF DEALING, USAGE OF TRADE OR OTHERWISE IMPLIED, SHALL EXIST IN CONNECTION WITH THE COMPANY'S PRODUCTS OR ANY SALE OR USE THEREOF. The Company shall in no event be liable for any loss of profits or any consequential or special damages incurred by Buyer. The Company's warranty shall run only to the first Buyer of a product from the Company, from the Company's distributor, or from an original equipment manufacturer resell-ing the Company's product, and is non-assignable and non-transferable and shall be of no force and effect if asserted by any person other than such first Buyer. This warranty applies only to the use of the product as intended by Seller and does not cover any misapplication or misuse of said product.

Warranty - ApplicationHubbell Power Systems, Inc. does not warrant the accuracy of and results from product or system performance recommendations resulting from any engineering analysis or study. This applies regardless of whether a charge is made for the recommendation, or if it is provided free of charge.

Responsibility for selection of the proper product or application rests solely with the purchaser. In the event of errors or inaccuracies determined to be caused by Hubbell Power Systems, Inc. , its liability will be limited to the re-performance of any such analysis or study.

©Copyright 2010 Hubbell/Ohio Brass • 1850 Richland Avenue, East • Aiken, SC 29801

Page 3: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-3

HUBBELL®

Power Systems

®

IntroductionOhio Brass has been producing high voltage surge arresters since the 1950’s and offers a wide variety of DynaVar® metal oxide gapless arresters designed to protect transformers, switchgear, and other equipment from switching and lightning surges. These arresters meet or exceed all requirements of the most current IEC standard and can be selected to match a range of contamination and energy requirements. Table 1 shows the Ohio Brass offerings included in this catalog.

Dedication to QualityOhio Brass has demonstrated that its Quality Management system is in compliance with ISO 9001:2000 and main-tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer receives high quality with every product. Ohio Brass also performs various Quality Assurance tests on every batch of metal-oxide varistor (MOV) blocks. The routine and design tests listed below, in addition to highly controlled manufacturing processes, ensure that Ohio Brass products demonstrate a superior level of quality. Our commitment to quality and continu-ous improvement is what the industry expects of its Leader.

Arrester TypeLine Discharge

ClassMaterial

PVI-LP 2 ESP Polymer

PVN 3 ESP Polymer

PH3 3 Silicone Polymer

PH4 4 Silicone Polymer

H3 3 Porcelain

H4 4 Porcelain

H5 5 Porcelain

Table 1: Ohio Brass Catalog Offerings

MOV Block Routine Tests:• Physical Inspection – Visual inspections are per-

formed at several steps of the block manufacturing process.

• Rated Energy Test – This procedure confirms the energy capability of each zinc oxide disc element.

• Residual Voltage Test – Every block undergoes an 8/20 current wave impulse to verify its V-I character-istics.

• Watts Loss Test – This test measures the AC watts loss and capacitive current characteristics of the disc.

MOV Block Batch QA Tests:• Square Wave Energy Test – Performed on a 5 disc

sample from each batch, this test is performed to quantify the batch energy capability.

• High Current Test – Each 5 disc sample is sub-jected to two high current discharges of the same polarity to ensure high current characteristics.

• A/C Life Test – The discs are placed under test con-ditions for a minimum of 250 hours to verify perfor-mance.

Arrester Routine Tests:• Physical Inspection – Every molded rubber part,

block, wrap module, brackets and completed unit is visually examined to reject defective products.

• Reference Voltage Test – This test measures the voltage once a predetermined maximum peak cur-rent is reached.

• Partial Discharge Test – This test ensures that the partial discharge level of the arrester does not ex-ceed a level of 10 pC.

• Residual Voltage – Tested on individual discs

Arrester Type Tests:• Testing Compliant with IEC 60099-4• Including:

v Insulation withstand tests on housingv Residual voltage testsv Long-duration current impulse withstandv Operating duty testsv Short circuit testsv Internal partial discharge tests

• Design Test Reports are available at:v www.hubbellpowersystems.comv Or contact your Hubbell Power Systems Rep.

Page 4: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-4®

Arrester Application ExampleIn grounded neutral circuits, a 110 kV system usually has a maximum line-to-line continuous voltage of 115.5 kV rms. This 115.5 kV divided by √3 equates to a 66.7 kV line-to-ground voltage. The appropriate DynaVar® arrester for this application is an arrester with a Uc of 70 kV since it is the lowest standard Uc that will meet or exceed the systems 66.kV line-to-ground voltage.

For ungrounded or impedance grounded systems, use the following selection guideline to choose the correct DynaVar® arrester. For applications where a ground fault is expected to be removed within 30 minutes, the minimum Uc threshold is the maximum system line-to-line voltage divided by 1.25.

For extended operation under ground fault conditions up to 2,000 hours, the minimum Uc is the maximum system line-to-line voltage divided by 1.11.

DynaVar arresters are designed to be used where average ambient temperature does not exceed 40°C (104°F) and the daily maximum temperature does not exceed 60°C (140°F).

For further assistance Ohio Brass application engineers are also available to provide system

specific recommendations for many different arrester applications.

Table 2:Normally Recommended DynaVar® Arrester UC for Various System Voltages

System Line-to-Line Voltage (kV)

Arrester UC (kV)

Nominal MaximumGrounded

Neutral Circuit

Temporary Ungrounded, Impedance

Grounded or Ungrounded

Circuits

(1) (2)

2.4 2.52 2.55 2.55 2.55

4.13 4.37 2.55 5.1 5.1

4.8 5.04 5.1 5.1 5.1

6.9 7.25 5.1 7.65 7.65

8.32 8.74 5.1 7.65 8.4

11 11.55 7.65 10.2 12.7

12.47 13.1 7.65 10.2 12.7

13.2 13.9 8.4 12.7 12.7

20.78 21.8 12.7 19.5 22

22 23.1 15.3 19.5 22

24.94 26.2 15.3 22 24.4

33 34.7 22 29 36.5

46 48.3 29 39 48

69 72.5 42 57 70

110 115.5 70 98 115

115 121 70 98 115

138 145 84 115 131

161 169 98 140 152

220 231 140 209 220

230 242 140 209 220

330 346.5 209 __ __

345 362 209 __ __

400 420 245 __ __

500 525 318 __ __

Arrester ApplicationThe primary factor in determining the most appropriate arrester is its continuous line-to-ground operating voltage (Uc or COV). When selecting the appropriate DynaVar® arrester for an effectively grounded neutral system, it is desirable to choose an arrester with the lowest Uc that will meet or exceed the systems line-to-ground voltage. The arrester application example illustrates the selection process that should be followed to choose the correct arrester for each system voltage.

(1) For normal duty. Line-to-line fault up to 30 minutes(2) For severe duty. Line-to-line fault up to 2,000 hours

Page 5: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-5

HUBBELL®

Power Systems

®

Type

Nominal Discharge

CurrentkA

Pressure Relief Rating

kA

Energy Capability

Single(4ms Impulse)

kJ/kV - Uc

Energy Capability

Single(4ms Impulse)

kJ/kV - Ur

Energy Capability

2-Shot(1 minute Thermal)

kJ/kV - Uc

Energy Capability

2-Shot(1 minute Thermal)kJ/kV - Ur

PVI-LP 10 40 3.4 2.8 6.4 5.1

PVN 10 80 4.9 4.0 9.0 7.2

H3 10 63 5.1 4.1 9.2 7.3

PH3 10 63 5.1 4.1 8.5 6.8

H4 20 63 9.2 7.4 13.3 10.6

PH4 20 63 9.2 7.4 12.9 10.3

H5 20 63 16.6 13.0 19.8 15.8

Ohio Brass General Arrester Information

Table 3: Energy Capability

Table 4: Surge Counter Information

All Ohio Brass IEC arresters exceed the pressure relief requirements of IEC 60099-4. 2-shot Energy Capability based on minimum values in IEC Operating Duty test. Actual values typically higher.

Table 5: Insulating Base Information

Table 5 shows the insulating bases for each Ohio Brass arrester type. Insulat-ing bases are installed on the arrester to ensure the surge is diverted through the counter.

Product Type Arrester WeightInsulating Base Catalog Number

Figure(Page 6)

PVI-LP All Weights 2730973001 A

PVN All Weights 2738303001 B

H3, PH3 Less than 218 kg 2730973001 A

H4, PH4 Greater than 218 kg 2721453076 C

H5 All Weights 2721453076 C

Counter Catalog Number

Creepage Current Meter

Range of mA Reading

Max No. Counts

Min Count Current

Max High Current

Withstand

Nominal Residual Voltage

245130 No N/A 999,999200A

(8/20µs wave)100 kA

(4/10µs wave)

5kV Peak (4/10µs wave)

@ 100 kA

245131 Yes 0 – 30 999,999200A

(8/20µs wave)100 kA

(4/10µs wave)

5kV Peak (4/10µs wave)

@ 100 kA

245134Yes

with Aux Output

0 – 30 999,999200A

(8/20µs wave)100 kA

(4/10µs wave)

5kV Peak (4/10µs wave)

@ 100 kA

245135 Yes 0 – 50 999,999200A

(8/20µs wave)100 kA

(4/10µs wave)

5kV Peak (4/10µs wave)

@ 100 kA

NOTE: Minimum of #6 AWG insulated ground wire required for connection

Page 6: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-6®

Insulating Subbase Drawings

NOTE: Dimensions shown in Inches (mm)

2.62 (67)

1.38 (35)

3.00 (76) DIA1/2-13 STUD, NUT &LOCKWASHER

LOCKWASHER1/2-13 STUD, NUT &

A Catalog No. 2730973001

B Catalog No. 2738303001

C Catalog No. 2721453076

2.38(60)

2.62 (67)

1.38 (35)

3.00 (76) DIA1/2-13 STUD, NUT &LOCKWASHER

LOCKWASHER1/2-13 STUD, NUT &

1.38

2.62

1.38

3.0 DIA

1/2-13 UNC-2A

1/2-13 UNC-2A

1/2-13 HEX NUT,LOCKWASHER

LOCKWASHER 1/2-13 HEX NUT,

& FLATWASHER

& FLATWASHER

1.75 DIA

3.00 DIA

1.38

2.62

2.38

1/2-13 HEX NUT,LOCKWASHER

1/2-13 UNC-2A

LOCKWASHER1/2-13 HEX NUT,

1/2-13 UNC-2A

& FLATWASHER

& FLATWASHER

Page 7: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-7

HUBBELL®

Power Systems

®

0.95

1.00

1.05

1.10

1.15

1.20

1 10 100Time (seconds)

Voltage (KV) per unit Ur

H4

PH4

PH3

H3

PVN

PVI-LP

Volt

age

(kV

) p

er u

nit

Ur

IEC Temporary Over-Voltage (TOV) Capability with Prior Duty

Temporary Over-Voltage CapabilityHubbell Power Systems arresters are gapless and consist of a column of metal-oxide blocks connected between line and ground. The blocks can withstand a significant power frequency overvoltage for a limited time, depend-ing on the magnitude of any immediately preceding surge duty. This duty can be the result of switching surges on higher voltage lines, or from other sources. All of the TOV curves are available in the Design Test Reports which are listed in the table below.

The entire set of Design Test Reports are available for download at the website:

http://www.hubbellpowersystems.com/powertest/literature_library/pdflib_design.html

The temporary overvoltage capability can be determined from the TOV curve. The prior duty curve of this table is based upon absorption of rated energy immediately preceding application of the overvoltage.

IEC Class Arrester TypeType Test

Report

2 PVI-LP EU1515

3 PVN EU1344

3 H3 EU1516

3 PH3 EU1527

4 H4 EU1517

4 PH4 EU1522

Page 8: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-8®

Polymer Housed Arresters(Type PVI-LP & PVN)

Table 6: Polymer Overview (Type PVI-LP & PVN)

Construction• Polymer housings are resistant to

rough handling and will not shatter in case of a failure.

• In comparison to equivalent porce-lain-housed arresters, these polymer housed gapless arresters are typically half the weight. This makes transpor-tation, handling and installation much easier.

• The single-unit, high voltage designs provide improved contamination per-formance over multi-unit designs.

• Closer spacing – Smaller line end cast-ings and smaller grading rings allow closer phase-to-phase spacing.

• MOV blocks are centered and re-strained with tightly woven fiberglass filament strands impregnated with epoxy resin.

• Minimal Internal Atmosphere – Will not “Breathe” or leak which eliminates moisture ingress, a cause of arrester failure.

For non-catalog polymer arresters that require higher creepage or special application please consult your Ohio Brass representative.

Product Type Housing MaterialLine Discharge

ClassVoltage Rating

Range (kV)Pressure Relief

(kA)Physical Strength

(N.m)

PVI-LP Polymer 2 3 – 72 40 180*

PVN Polymer 3 3 - 228 63 2,260*

NOTE: Physical Strength values for tripod base configuration*MPSL – Maximum Permissible Service Load

Page 9: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-9

HUBBELL®

Power Systems

®

PVI-LP Polymer Housed

IEC Class 2 ArresterPVI-LP Ordering System

3 0 X X X XPolymer Housed

Type PVI-LP StandardArresterCatalogNumber

Ur(kV)

Uc(kV)

803805808809610

3 6 91012

2.55 5.1 7.65 8.410.2

813815817620822

1518212427

12.715.31719.522

824629831636639

3036394548

24.42931.536.539

642648657

546072

424857

0Small Top & Tripod Base for Horizontal and Vertical Mounting. (Dimensions & Weights as shown in Physical Characteristics

1Small Top & Small Base for Vertical Mount-ing only. Note: Deduct 23 mm & 1.25 kg from Physical Characteristics

2Tripod Top & Small Base for Underhung Mounting. (Dimensions & Weights as shown in Physical Characteristics

3Tripod Top & Tripod Base for Horizontal, Vertical and Underhung Mounting. Note: Add 29 mm & 1.25 kg from Physical Characteristics

Page 10: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-10®

Ur(kV)

Uc(kV)

Maximum0.5µs

DischargeVoltagekV (1)

Maximum Switching

Surge Protective Level

kV (2)

Maximum Residual voltage Using and 8/20 Current Wave-kV

1.5kA 3kA 5kA 10kA 20kA 40kA

3 6 91012

2.555.1

7.658.4 10.2

8.617.125.828.434.1

6.412.719.121.125.3

6.813.620.522.627.1

7.214.421.623.828.6

7.515.022.624.929.9

8.116.224.426.932.3

9.017.927

29.835.8

10.120.230.433.540.3

1518212427

12.715.317

19.522

42.951.656.968.377.4

31.838.342.250.657.4

34.140.945.154.261.4

3643.247.757.264.9

37.645.249.959.967.9

40.648.853.864.673.2

44.954

59.671.581

50.660.967.180.691.3

3036394548

24.429

31.536.539

85.3102

108.4125.1136.6

63.376

80.492.8101.3

67.781.386.199.3108.4

71.585.990.9104.9114.5

74.889.895.1109.8119.8

80.796.9102.6118.4129.2

89.3107

113.6131.1143

101121

127.9147.6161.1

546072

424857

147.9165199

109.7122.4147.7

117.4131

158.1

125138.3166.9

129.7144.7174.6

139.9156.1188.4

154.9172.8209

174.5195235

PVI-LP Protective Characteristics

(1) Maximum residual voltage for a 10kA impulse current wave which produces a voltage wave cresting in 0.5µs. This can be used for coordination where front-of-wave sparkover was formerly used.

(2) Based on a 500A surge of 45-µs time to crest.

(1) Minimum clearances are based on arrester protective levels and should be increased when necessary to meet local requirements for spacing of energized equipment.

PVI-LP Physical Characteristics

Standard Arrester Catalog Number

Ur(kV)

Uc(kV)

Height“X”

Dimension(mm)

CreepageDistance

(mm)

Minimum Mounting

NetWeight

(kg)

Insulation Withstand Values

Phase to

Phase (mm)

Phase to

Ground (mm)

Lightning Impulse

BIL 1.2/50 (kVcr)

Switching Impulse (kVcr)

PowerFrequency

1 Minute WetWithstand(kVrms)

300803300805300808300809300610

3 6 91012

2.555.1

7.658.4 10.2

173173173173173

391391391391391

112117119125125

8481848989

2.82.82.82.82.8

100100100100100

6060606060

4040404040

300813300815300817300620300822

1518212427

12.715.317

19.522

310310310310447

782782782782

1,173

158168193193244

122132158158208

4.54.54.54.56.1

165165165165230

100100100100140

70707070105

300824300629300831300636300639

3036394548

24.429

31.536.539

447447584584584

1,1731,1731,5651,5651,565

249249325325325

213213290290290

6.16.17.77.77.7

230230310310310

140140180180180

105105140140140

300642300648300657

546072

424857

721721859

1,9561,9562,347

401401503

366366467

8.88.810.4

390390450

230230260

180180220

Page 11: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-11

HUBBELL®

Power Systems

®

Base Mounting InformationThe end casting shown in Figure 1 is furnished with three slots suitable for use on either a 222.35 mm or 254 mm diameter bolt circle. Mounting hardware is not furnished with the arrester.

Figure 1: PVI-LP End Casting

Figure 2: PVI-LP with Eye-Bolt Line Terminal

PVI-LP Terminals• Standard line and ground terminals will accommodate conductor sizes from 6 mm to 21mm diameter• The terminals are of hot dip galvanized malleable iron and compatible with either aluminum or copper.• Code 3001: Standard line and ground terminals with U.S. Domestic packaging. (Example: 3008XX3001)• Code 3010: Standard line and ground terminals with Export packaging. (Example: 3008XX3010)• For other terminal options please consult your Ohio Brass Representative.

Figure 4Standard Line Terminal

Catalog Number M718743001(small top only)

Figure 5Standard Ground Terminal

Catalog Number M718743001

Figure 6Single Bucket Terminal Assembly

used with all terminal combinationsCatalog Number M2714143001

Figure 3: PVI-LP with Four Hole NEMA Line Terminal

Page 12: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-12®

PVN Polymer Housed IEC Class 3 ArresterPVN Ordering System

3 1 X X X XPolymer Housed

Type PVN StandardArresterCatalogNumber

Ur(kV)

Uc(kV)

003005008009010

3 6 91012

2.55 5.1 7.65 8.4 10.2

013015017019022

1518212427

12.7 15.3 17 19.5 22

024029031036039

3036394548

24.4 29 31.5 36.5 39

042048057070076

5460729096

42 48 57 70 76

084088098106115

108108120132144

84 88 98106115

131140144152180

168172180192228

131140144152180

0Small Top & Tripod Base for Horizontal and Vertical Mounting. (Dimensions & Weights as shown in Physical Characteristics

1Small Top & Small Base for Vertical Mount-ing only. Note: Deduct 23 mm & 1.25 kg from Physical Characteristics

2Tripod Top & Small Base for Underhung Mounting. (Dimensions & Weights as shown in Physical Characteristics

3Tripod Top & Tripod Base for Horizon-tal, Vertical and Under-hung Mount-ing. Available through 57kV Uc.Note: Add 25.4mm & 2.268 kg from Physical Characteristics

4Spade Top & Tripod Base. For Horizontal and Vertical Mounting. NEMA pad line terminal top.Note: Add 88.9mm & 0.907 kg from Physical Characteristics

5Tripod Top & Spade Base for Underhung Mounting. Note: Add 88.9 mm & 0.907 kg from Physical Characteristics

Uc (kV) Drop(mm) “A”

Dia.(mm) “B”

84 - 88 122 356

98 - 115 229 420

131 - 180 368 708

Grading RingsRings are required and provided

by Ohio Brass on arresters 84kV Uc and above.

Page 13: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-13

HUBBELL®

Power Systems

®

Ur(kV)

Uc(kV)

Maximum0.5µs

DischargeVoltagekV (1)

Maximum Switching Surge Protective Level

kV (2)

Maximum Residual Voltage Using and 8/20 Current Wave-kV Insulation Withstand Values

1.5kA 3kA 5kA 10kA 20kA 40kA1.2/50

BIL (kVcr)

Switch-ing

Impulse (kVcr)

Power Fre-

quency/ Minute

Wet (kVrms)

3 6 91012

2.555.1

7.658.4 10.2

8.416.725

27.833.3

611.917.819.823.7

6.412.819.221.425.6

6.713.520.222.526.9

7.114.121.123.528.1

7.615.222.725.330.3

8.416.825.128

33.5

9.619.128.331.838.1

120120120120161

88888888113

5757575774

1518212427

12.715.317

19.522

41.750.156.363.972.9

29.735.640.145.551.9

3238.443.249.156

33.740.445.551.658.9

35.242.347.654

61.6

37.945.551.258.166.3

4250.456.764.373.4

47.657.264.473

83.3

161161241241241

113113163163163

7474109109109

3036394548

24.429

31.536.539

80.495.9104.2120.9128.7

57.268.374.286.191.6

61.773.680

92.896.8

64.977.484.197.6103.9

67.98188

102.1108.7

73.187.294.7109.9117

80.996.5104.8121.7129.5

91.9109.6119

138.1147.1

241241321321321

163163213213213

109109145145145

5460729096

4248577076

144.4163.5191.8241.8257.4

102.8116.4136.6172.1183.2

110.9125.5147.3185.6197.6

116.6132

154.9195.2207.8

122138162

204.2217.4

131.3146.6174.4219.8234

145.3164.5193.1243.3259

165186.8219.2276.3294.1

401401450639639

264264295415415

182182200295295

108108120132144

848898106115

288.9288.9326.9352

386.1

205.6205.6241.3252285

221.8221.8251270

296.5

233.2233.2263.9284

311.7

244244

276.1298

326.1

262.6262.6297.2317351

290.7290.7329353

388.6

330.1330.1373.6404

441.2

700700660660817

450450428428530

320320306306385

168172180192228

131140144152180

445455476508604

330338354377448

343351367391465

363372389415493

380389407434516

409419438467556

446457478509607

503516539575664

10501050105010501520

560560560560720

400400400400500

PVN Protective Characteristics

(*) Designates Base Selection. See PVN Ordering System.(1) Maximum residual voltage for a 10kA impulse current wave which produces a voltage wave cresting in 0.5µs. This can be used for coor-

dination where front-of-wave sparkover was formerly used.(2) Based on a 500A surge of 45-µs time to crest through 88kV Uc, and 1,000A surge of 45µs time to crest of 98 kV Uc and higher ratings.

PVN Mounting ArrangementsType PVN arresters may be mounted vertically, horizontally or underhung, provided the cantilever moment is not excessive. Underhung mounting requires factory as-sembly of the base mounting hardware at the top of the arrester to ensure proper shed orientation. For the correct underhung catalog number replace the third digit with 2 or 5 as shown in the PVN Ordering System on the next page.

The PVN arrester construction is non-rigid, and will exhibit an observable deflection when cantilever load is applied. This deflection is normal and will not affect perfor-mance. The rated ultimate cantilever moment of the PVN arrester with the tripod base is 2260 N.m. The maximum working moment for the 2.55-115 kV Uc is 1130 N.m. For 131 thru 180 kV Uc with the tripod base, the maximum working moment is 565 N.m. For the round cap base design, the maximum working moment is 339 N.m.

NOTE: PVN arresters above 115 kV Uc are not recommended for horizontal mounting.

Page 14: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-14®

PVN Physical Characteristics

Standard Arrester Catalog Number

Ur(kV)

Uc(kV)

Height“X”

Dimension(mm)

CreepageDistance

(mm)

Minimum MountingNet

Weight(kg)

Phase to

Phase (mm)

Phase to

Ground (mm)

31*00331*00531*00831*00931*010

3 6 91012

2.555.1

7.658.4 10.2

259259259259325

584584584584787

312312312312312

196196196196196

9.29.49.79.811.4

31*01331*01531*01731*01931*022

1518212427

12.715.317

19.522

325325462462462

787787116811681168

312312312312312

196196196203224

11.711.915.215.515.7

31*02431*02931*03131*03631*039

3036394548

24.429

31.536.539

462462597597597

11681168157515751575

312351371414432

244279300343361

1616.619.720.120.5

31*04231*04831*05731*07031*076

5460729096

4248577076

73273286411331133

19811981233731503150

472523594686775

401452523622711

23.924.334.834.936.3

31*08431*08831*09831*10631*115

108108120132144

848898106115

14051405140514051671

39623962396239624724

11301130124513461422

927927104111431219

44.944.945.847.654.5

31*13131*14031*14431*15231*180

168172180192228

131140144152180

21442144214421442850

59445944594459447925

18801956198121342388

15241600162617782032

68.968.968.968.991.2

Figure 1: 310XXX illustrates the PVN “X” Dimension.

Figure 2: Four Hole NEMA Pad Line Terminal with Two Bucket

Terminal Assemblies. Bucket Terminal shown in

Figure 5.

PVN Terminals• Standard line and ground terminals will accommodate conductor sizes from 6 mm to 21mm diameter• The terminals are of hot dip galvanized malleable iron and compatible with either aluminum or copper.• Code 3001: Standard line and ground terminals with U.S. Domestic packaging. (Example: 31*XXX3001)• Code 3010: Standard line and ground terminals with Export packaging. (Example: 31*XXX3010)• For other terminal options please consult your Ohio Brass representative.

Figure 3Standard Line Terminal

Catalog Number M718743001(small top only)

Figure 4Standard Ground Terminal

Catalog Number M718743001

Figure 5Single Bucket Terminal Assembly

used with all terminal combinationsCatalog Number M2714143001

NOTE 1: The * is replaced by 0, 1, 2, 3, 4, 5 depending on configuration shown on page 12.NOTE 2: Minimum clearances are based on arrester protective levels and should be increased to meet

local requirements for spacing of energized equipment.NOTE 3: Weight of Grading Ring added to Uc of 84 kV and higher.NOTE 4: The large energized diameter of the 313XXX requires additional clearance.

Page 15: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-15

HUBBELL®

Power Systems

®

Polymer Housed Arresters(Types PH3 & PH4)

Construction• Hollow Core Design• Silicone Rubber Housing• Same proven sealing system as used in our porcelain H3 & H4 designs• High mechanical strength• High creepage distance designs available • Same high quality MOV tech-

nology as all other Ohio Brass arresters

For non-catalog polymer arresters that require higher creepage or special application please consult your Ohio Brass representative.

Table 7: Polymer Overview (Types PH3 & PH4)

Product Type Housing MaterialLine Discharge

ClassVoltage Rating

Range (kV)Pressure Relief

(kA)Physical Strength

(N.m)

PH3 Polymer 3 24-420 63 8,000*

PH4 Polymer 4 24-420 63 8,000*

*MPSL – Maximum Permissible Service Load

Page 16: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-16®

Use the following selection tables to build the correct Ohio Brass PH3 and PH4 Arresters.

Step 1: Select the correct arrester line discharge class from Table 8 and fill in B.

Ohio Brass PH3 & PH4 Ordering System:

Step 2: Select the Max System Voltage (Um) from Table 9 and fill in Cells C through E.

Step 3: Polymer color is gray only. Fill in Box F with “G”.

Step 4: Select the appropriate Pollution level from Table 11 and fill in G.

Catalog Ordering System A B C D E F G H I J K L P H

Table 8

Table 9

Table 10

Table 11

Arrester Class BClass 3 - PH3 Arrester 3

Class 4 - PH4 Arrester 4

Polymer Color FGrey G

Pollution Level GMedium (≥ 20 mm per kV Um) M

Heavy (≥ 25 mm per kV Um) H

Very Heavy (≥ 31 mm per kV Um) V

Max System Voltage (kV)

C D E

36 0 3 6

52 0 5 2

72 0 7 2

100 1 0 0

123 1 2 3

145 1 4 5

170 1 7 0

245 2 4 5

300 3 0 0

362 3 6 2

420 4 2 0

NOTE: Pollution levels per IEC - 60099-4

Page 17: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-17

HUBBELL®

Power Systems

®

Step 5: Select the appropriate Rated Voltage (Ur) from Table 12 that corresponds with the Max System voltage selected for C through E and fill in Cells H through J.

Max System Voltage (kV)

Rated Voltage

(kV)H I J

36

24 0 2 430 0 3 033 0 3 336 0 3 639 0 3 9

52

42 0 4 248 0 4 851 0 5 154 0 5 460 0 6 0

72

54 0 5 460 0 6 066 0 6 672 0 7 275 0 7 578 0 7 881 0 8 184 0 8 4

10084 0 8 490 0 9 096 0 9 6

123

90 0 9 096 0 9 6108 1 0 8120 1 2 0132 1 3 2138 1 3 8

145

108 1 0 8120 1 2 0132 1 3 2138 1 3 8144 1 4 4

Table 12

170

132 1 3 2144 1 4 4162 1 6 2168 1 6 8

245

180 1 8 0192 1 9 2198 1 9 8216 2 1 6228 2 2 8

300

216 2 1 6228 2 2 8240 2 4 0258 2 5 8264 2 6 4

362

258 2 5 8264 2 6 4276 2 7 6288 2 8 8

420

312 3 1 2330 3 3 0336 3 3 6360 3 6 0372 3 7 2378 3 7 8390 3 9 0396 3 9 6420 4 2 0

Step 6: Select the appropriate Line and Ground termi-nals based on the conductor size ranges in Table 13 and fill in K & L.

PH3 Catalog Ordering Example• Max System Voltage – 145kV• Grey Polymer• Heavy Pollution Level• Rated Voltage – 120 kV• Line & Ground Size - 25 to 240mm

Step 1: Use Max system Voltage to fill in C through E – 145kV v (PH3145xxxxxxx)

Step 2: Select Grey Polymer – G v (PH3145Gxxxxxx)

Step 3: Select Heavy Pollution – H v (PH3145GHxxxxx)

Step 4: Select Rated Voltage – 120kV v (PH3145GH120xx)

Step 5: Select correct terminals v (PH3145GH120AA)

Step 6: Order Ohio Brass Catalog Number v PH3145GH120AA

PH4 Catalog Ordering Example• Max System Voltage – 145kV• Grey Polymer• Heavy Pollution Level• Rated Voltage – 120 kV• Line & Ground Size - 25 to 240mm

Step 1: Use Max system Voltage to fill in C through E – 145kV v (PH4145xxxxxxx)

Step 2: Select Grey Polymer – G v (PH4145Gxxxxxx)

Step 3: Select Heavy Pollution – H v (PH4145GHxxxxx)

Step 4: Select Rated Voltage – 120kV v (PH4145GH120xx)

Step 5: Select correct terminals v (PH4145GH120AA)

Step 6: Order Ohio Brass Catalog Number v PH4145GH120AA

Table 13Line Size

(mm2)Ground Size

(mm2)K L

25 - 240

25 - 240 A A

70 - 630 A B

500 - 1000 A C

70 - 630

25 - 240 B A

70 - 630 B B

500 - 1000 B C

500 - 1000

25 - 240 C A

70 - 630 C B

500 - 1000 C C

Page 18: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-18®

PH3Polymer Housed

IEC Class 3 Arrester

Standard Ground Terminal

Standard Suspension Cap

*NOTE: 17 mm hole used for lifting hook.

Page 19: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-19

HUBBELL®

Power Systems

®

PH3 Protective Characteristics

UrkV

UckV

Temporary Over-Voltage Withstand at indicated duration

Max 36/90 Switching Impulse Residual Voltage at indicated

current

Max 8/20 Lightning Impulse Residual Voltage at indicated current

1s 10s 100s 0.25kA 0.5kA 1kA 2kA 1.5kA 3kA 5kA 10kA 20kA 40kA

kVrms kVrms kVrms kV kV kV kV kV kV kV kV kV kV

27 21.6 31 28 26 50 51 53 56 55 57 60 64 70 79

30 24.0 34 31 29 56 57 59 62 61 64 67 71 77 88

33 26.4 37 34 32 61 62 65 68 67 70 73 79 85 97

36 28.8 41 37 35 67 68 71 74 73 76 80 86 93 106

39 31.2 44 40 38 72 74 77 80 79 83 87 93 100 115

42 33.6 48 43 41 78 79 83 87 86 89 93 100 108 123

48 38.4 54 49 47 89 91 94 99 98 102 107 114 124 141

51 40.8 58 53 49 94 96 100 105 104 108 113 122 131 150

54 43.2 61 56 52 100 102 106 111 110 115 120 129 139 159

60 48.0 68 62 58 111 113 118 124 122 127 133 143 155 176

66 52.8 75 68 64 122 125 130 136 134 140 147 157 170 194

72 57.6 82 74 70 133 136 142 148 147 153 160 172 185 212

75 60.0 85 77 73 139 142 148 155 153 159 167 179 193 220

78 62.4 88 80 76 144 147 154 161 159 165 173 186 201 229

81 64.8 92 84 79 150 153 159 167 165 172 180 193 209 238

84 67.2 95 87 81 156 159 165 173 171 178 187 200 216 247

90 72.0 102 93 87 167 170 177 186 183 191 200 214 232 264

96 76.8 109 99 93 178 181 189 198 196 204 213 229 247 282

108 86.4 122 111 105 200 204 213 223 220 229 240 257 278 317

120 96.0 136 124 116 222 227 236 247 245 255 267 286 309 353

132 105.6 150 136 128 244 249 260 272 269 280 293 315 340 388

138 110.4 156 142 134 256 261 272 284 281 293 307 329 356 406

144 115.2 163 148 140 267 272 283 297 293 305 320 343 371 423

162 129.6 184 167 157 300 306 319 334 330 344 360 386 417 476168 134.4 190 173 163 311 317 331 346 342 356 373 400 433 494

180 144.0 204 186 175 333 340 354 371 367 382 400 429 464 529

192 153.6 218 198 186 356 363 378 396 391 407 426 458 495 564

198 158.4 224 204 192 367 374 390 408 403 420 440 472 510 582

216 172.8 245 223 210 400 408 425 445 440 458 480 515 556 635

228 182.4 258 235 221 422 431 449 470 465 484 506 543 587 670

240 192.0 272 247 233 444 454 472 495 489 509 533 572 618 705

258 206.4 292 266 250 478 488 508 532 526 547 573 615 665 758

264 211.2 299 272 256 489 499 520 544 538 560 586 629 680 776

276 220.8 313 285 268 511 522 543 569 562 585 613 658 711 811

288 230.4 326 297 279 533 544 567 594 587 611 640 686 742 846

312 249.6 353 322 303 578 590 614 643 636 662 693 744 804 917

330 264.0 374 340 320 611 624 650 680 672 700 733 786 850 970

336 268.8 381 346 326 622 635 661 693 685 713 746 801 866 987

360 288.0 408 371 349 667 680 709 742 734 764 800 858 927 1058

372 297.6 421 384 361 689 703 732 767 758 789 826 887 958 1093

378 302.4 428 390 367 700 714 744 779 770 802 840 901 974 1111

390 312.0 442 402 378 722 737 768 804 795 827 866 929 1005 1146

396 316.8 449 408 384 733 748 780 816 807 840 880 944 1020 1164

420 336.0 476 433 407 778 794 827 866 856 891 933 1001 1082 1234

Page 20: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-20®

PH3 Physical Characteristics

Catalog #Um(kV)

Ur(kV)

Uc(kV)

(M)edium pollution (H)eavy pollution (V)ery heavy pollution

Creepage Distance

(mm)

Height “H”

(mm)

PH3 Figure

Number

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

PH3 Figure

Number

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

PH3 Figure

Number

Weight (kg)

PH3036G*024AA

36

24 19.2 2130 967 1 46 2130 967 1 46 2130 967 1 46

PH3036G*030AA 30 24.0 2130 967 1 45 2130 967 1 45 2130 967 1 45

PH3036G*033AA 33 26.4 2130 967 1 46 2130 967 1 46 2130 967 1 46

PH3036G*036AA 36 28.8 2130 967 1 46 2130 967 1 46 2130 967 1 46

PH3036G*039AA 39 31.2 2130 967 1 47 2130 967 1 47 2130 967 1 47

PH3052G*042AA

52

42 33.6 2130 967 1 47 2130 967 1 47 2130 967 1 47

PH3052G*048AA 48 38.4 2130 967 1 49 2130 967 1 49 2130 967 1 49

PH3052G*051AA 51 40.8 2130 967 1 51 2130 967 1 51 2130 967 1 51

PH3052G*054AA 54 43.2 2130 967 1 50 2130 967 1 50 2130 967 1 50

PH3052G*060AA 60 48.0 2130 967 1 51 2130 967 1 51 2130 967 1 51

PH3072G*054AA

72

54 43.2 2130 967 1 50 2130 967 1 50 2880 1127 1 52

PH3072G*060AA 60 48.0 2130 967 1 51 2130 967 1 51 2880 1127 1 53

PH3072G*066AA 66 52.8 2130 967 1 52 2130 967 1 52 2880 1127 1 55

PH3072G*072AA 72 57.6 2130 967 1 53 2130 967 1 53 2880 1127 1 56

PH3072G*075AA 75 60.0 2130 967 1 56 2130 967 1 56 2880 1127 1 58

PH3072G*078AA 78 62.4 2130 967 1 54 2130 967 1 54 2880 1127 1 57

PH3072G*081AA 81 64.8 2130 967 1 57 2130 967 1 57 2880 1127 1 59

PH3072G*084AA 84 67.2 2880 1127 1 58 2880 1127 1 58 2880 1127 1 58

PH3100G*084AA

100

84 67.2 2880 1127 1 58 2880 1127 1 58 3620 1323 1 62

PH3100G*090AA 90 72.0 2880 1127 1 59 2880 1127 1 59 3620 1323 1 63

PH3100G*096AA 96 76.8 2880 1127 1 62 2880 1127 1 62 3620 1323 1 66

PH3123G*090AA

123

90 72.0 2880 1127 1 59 3620 1323 1 63 4370 1493 1 67

PH3123G*096AA 96 76.8 2880 1127 1 62 3620 1323 1 66 4370 1493 1 70

PH3123G*108AA 108 86.4 3620 1323 1 68 3620 1323 1 68 4370 1493 1 72

PH3123G*120AA 120 96.0 3620 1323 1 70 3620 1323 1 70 4370 1493 1 75

PH3123G*132AA 132 105.6 4370 1493 1 77 4370 1493 1 77 4370 1493 1 77

PH3123G*138AA 138 110.4 4370 1493 1 78 4370 1493 1 78 4370 1493 1 78

PH3145G*108AA

145

108 86.4 3620 1323 1 68 4370 1493 1 72 5010 1951 2 97

PH3145G*120AA 120 96.0 3620 1323 1 70 4370 1493 1 75 5010 1951 2 99

PH3145G*132AA 132 105.6 4370 1493 1 77 4370 1493 1 77 5010 1951 2 102

PH3145G*138AA 138 110.4 4370 1493 1 78 4370 1493 1 78 5010 1951 2 103

PH3145G*144AA 144 115.2 4370 1493 1 79 4370 1493 1 79 5010 1951 2 104

NOTE: The * is replaced by M for Medium Pollution, H for Heavy Pollution, or V for Very Heavy Pollution.

Table continued on next page.

Page 21: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-21

HUBBELL®

Power Systems

®

Catalog #Um(kV)

Ur(kV)

Uc(kV)

(M)edium pollution (H)eavy pollution (V)ery heavy pollution

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring Dia. “D” (mm)

PH3 Fig. No.

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring Dia. “D” (mm)

PH3 Fig. No.

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring

Dia. “D” (mm)

PH3 Fig.No.

Weight (kg)

PH3170G*132AA

170

132 105.6 4370 1493 n/a 1 77 4370 1493 n/a 1 77 5760 2111 640 3 112

PH3170G*144AA 144 115.2 4370 1493 n/a 1 79 4370 1493 n/a 1 79 5760 2111 640 3 114

PH3170G*162AA 162 129.6 5010 1951 n/a 2 109 5010 1951 n/a 2 109 5760 2111 n/a 2 111

PH3170G*168AA 168 134.4 5010 1951 n/a 2 110 5010 1951 n/a 2 110 5760 2111 n/a 2 112

PH3245G*180AA

245

180 144.0 5010 1951 640 3 120 6500 2307 640 3 130 7990 2673 990 3 138

PH3245G*192AA 192 153.6 5760 2111 640 3 125 6500 2307 640 3 129 7990 2673 640 3 141

PH3245G*198AA 198 158.4 5760 2111 640 3 127 6500 2307 640 3 130 7990 2673 640 3 142

PH3245G*216AA 216 172.8 6500 2307 640 3 134 6500 2307 640 3 134 7990 2673 640 3 142

PH3245G*228AA 228 182.4 6500 2307 640 3 137 6500 2307 640 3 137 7990 2673 640 3 144

PH3300G*216AA

300

216 172.8 6500 2307 990 3 137 7990 2673 1530 3 154 9380 3291 1530 4 182

PH3300G*228AA 228 182.4 6500 2307 990 3 141 7990 2673 990 3 156 9380 3291 1530 4 185

PH3300G*240AA 240 192.0 7240 2503 990 3 147 7990 2673 990 3 151 9380 3291 990 4 187

PH3300G*258AA 258 206.4 7990 2673 640 3 155 7990 2673 990 3 155 9380 3291 990 4 182

PH3300G*264AA 264 211.2 7990 2673 640 3 156 7990 2673 990 3 156 9380 3291 990 4 183

PH3362G*258AA

362

258 206.4 9380 3291 1530 4 177 9380 3291 1530 4 177 11610 3853 2030 4 209

PH3362G*264AA 264 211.2 9380 3291 1530 4 178 9380 3291 1530 4 178 11610 3853 1530 4 190

PH3362G*276AA 276 220.8 9380 3291 1530 4 180 9380 3291 1530 4 180 11610 3853 1530 4 192

PH3362G*288AA 288 230.4 8740 2843 990 3 147 9380 3291 1530 4 181 11610 3853 1530 4 194

PH3420G*312AA

420

312 249.6 9380 3291 1530 4 202 10860 3683 1530 4 210 13110 4193 2030 4 243

PH3420G*330AA 330 264.0 10120 3487 1530 4 207 10860 3683 1530 4 214 13110 4193 1530 4 226

PH3420G*336AA 336 268.8 10120 3487 1530 4 211 10860 3683 1530 4 215 13110 4193 1530 4 228

PH3420G*360AA 360 288.0 10860 3683 1530 4 221 10860 3683 1530 4 221 13110 4193 1530 4 232

PH3420G*372AA 372 297.6 10860 3683 1530 4 223 10860 3683 1530 4 223 13110 4193 1530 4 236

PH3420G*378AA 378 302.4 10860 3683 1530 4 224 10860 3683 1530 4 224 13110 4193 1530 4 237

PH3420G*390AA 390 312.0 11610 3853 1530 4 231 11610 3853 1530 4 231 13110 4193 1530 4 239

PH3420G*396AA 396 316.8 11610 3853 1530 4 232 11610 3853 1530 4 232 13110 4193 1530 4 232

PH3420G*420AA 420 336.0 12360 4023 1530 4 232 12360 4023 1530 4 232 13110 4193 1530 4 237

PH3 Physical Characteristics (continued)

NOTE: The * is replaced by M for Medium Pollution, H for Heavy Pollution, or V for Very Heavy Pollution.

Page 22: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-22®

Max System Voltage

Rated Voltage

Max Continuous Voltage L-G

PH3 standard pollution ratings

Medium Heavy Very Heavy

Um Ur Uc Catalog Creep (mm)

10KA FOW* (kV)

Housing Code Catalog Creep

(mm)

10KA FOW* (kV)

Housing Code Catalog Creep

(mm)

10KA FOW* (kV)

Housing Code

36 27 21.6 PH3036GM027 2130 77 1 PH3036GH027 2130 77 1 PH3036GV027 2130 77 136 30 24.0 PH3036GM030 2130 85 1 PH3036GH030 2130 85 1 PH3036GV030 2130 85 136 33 26.4 PH3036GM033 2130 93 1 PH3036GH033 2130 93 1 PH3036GV033 2130 93 136 36 28.8 PH3036GM036 2130 100 1 PH3036GH036 2130 100 1 PH3036GV036 2130 100 136 39 31.2 PH3036GM039 2130 108 1 PH3036GH039 2130 108 1 PH3036GV039 2130 108 152 42 33.6 PH3052GM042 2130 115 1 PH3052GH042 2130 115 1 PH3052GV042 2130 115 152 48 38.4 PH3052GM048 2130 130 1 PH3052GH048 2130 130 1 PH3052GV048 2130 130 152 51 40.8 PH3052GM051 2130 138 1 PH3052GH051 2130 138 1 PH3052GV051 2130 138 152 54 43.2 PH3052GM054 2130 146 1 PH3052GH054 2130 146 1 PH3052GV054 2130 146 152 60 48.0 PH3052GM060 2130 162 1 PH3052GH060 2130 162 1 PH3052GV060 2130 162 172 54 43.2 PH3072GM054 2130 144 1 PH3072GH054 2130 144 1 PH3072GV054 2880 146 272 60 48.0 PH3072GM060 2130 160 1 PH3072GH060 2130 160 1 PH3072GV060 2880 162 272 66 52.8 PH3072GM066 2130 176 1 PH3072GH066 2130 176 1 PH3072GV066 2880 177 272 72 57.6 PH3072GM072 2130 191 1 PH3072GH072 2130 191 1 PH3072GV072 2880 193 272 75 60.0 PH3072GM075 2130 199 1 PH3072GH075 2130 199 1 PH3072GV075 2880 201 272 78 62.4 PH3072GM078 2130 207 1 PH3072GH078 2130 207 1 PH3072GV078 2880 208 272 81 64.8 PH3072GM081 2130 215 1 PH3072GH081 2130 215 1 PH3072GV081 2880 216 272 84 67.2 PH3072GM084 2880 224 2 PH3072GH084 2880 224 2 PH3072GV084 2880 224 2100 84 67.2 PH3100GM084 2880 222 2 PH3100GH084 2880 222 2 PH3100GV084 3620 224 3100 90 72.0 PH3100GM090 2880 237 2 PH3100GH090 2880 237 2 PH3100GV090 3620 239 3100 96 76.8 PH3100GM096 2880 253 2 PH3100GH096 2880 253 2 PH3100GV096 3620 255 3123 90 72.0 PH3123GM090 2880 236 2 PH3123GH090 3620 238 3 PH3123GV090 4370 239 4123 96 76.8 PH3123GM096 2880 251 2 PH3123GH096 3620 253 3 PH3123GV096 4370 255 4123 108 86.4 PH3123GM108 3620 284 3 PH3123GH108 3620 284 3 PH3123GV108 4370 286 4123 120 96.0 PH3123GM120 3620 316 3 PH3123GH120 3620 316 3 PH3123GV120 4370 317 4123 132 105.6 PH3123GM132 4370 348 4 PH3123GH132 4370 348 4 PH3123GV132 4370 348 4123 138 110.4 PH3123GM138 4370 364 4 PH3123GH138 4370 364 4 PH3123GV138 4370 364 4145 108 86.4 PH3145GM108 3620 283 3 PH3145GH108 4370 284 4 PH3145GV108 5010 289 12145 120 96.0 PH3145GM120 3620 314 3 PH3145GH120 4370 316 4 PH3145GV120 5010 320 12145 132 105.6 PH3145GM132 4370 347 4 PH3145GH132 4370 347 4 PH3145GV132 5010 351 12145 138 110.4 PH3145GM138 4370 362 4 PH3145GH138 4370 362 4 PH3145GV138 5010 367 12145 144 115.2 PH3145GM144 4370 378 4 PH3145GH144 4370 378 4 PH3145GV144 5010 383 12170 132 105.6 PH3170GM132 4370 345 4 PH3170GH132 4370 345 4 PH3170GV132 5760 351 22170 144 115.2 PH3170GM144 4370 376 4 PH3170GH144 4370 376 4 PH3170GV144 5760 382 22170 162 129.6 PH3170GM162 5010 427 12 PH3170GH162 5010 427 12 PH3170GV162 5760 429 22170 168 134.4 PH3170GM168 5010 443 12 PH3170GH168 5010 443 12 PH3170GV168 5760 445 22245 180 144.0 PH3245GM180 5010 468 12 PH3245GH180 6500 472 23 PH3245GV180 7990 476 34245 192 153.6 PH3245GM192 5760 501 22 PH3245GH192 6500 503 23 PH3245GV192 7990 507 34245 198 158.4 PH3245GM198 5760 517 22 PH3245GH198 6500 519 23 PH3245GV198 7990 522 34245 216 172.8 PH3245GM216 6500 566 23 PH3245GH216 6500 566 23 PH3245GV216 7990 569 34245 228 182.4 PH3245GM228 6500 597 23 PH3245GH228 6500 597 23 PH3245GV228 7990 600 34300 216 172.8 PH3300GM216 6500 561 23 PH3300GH216 7990 565 34 PH3300GV216 9380 571 223300 228 182.4 PH3300GM228 6500 592 23 PH3300GH228 7990 596 34 PH3300GV228 9380 602 223300 240 192.0 PH3300GM240 7240 626 33 PH3300GH240 7990 627 34 PH3300GV240 9380 634 223300 258 206.4 PH3300GM258 7990 674 34 PH3300GH258 7990 674 34 PH3300GV258 9380 680 223300 264 211.2 PH3300GM264 7990 690 34 PH3300GH264 7990 690 34 PH3300GV264 9380 696 223362 258 206.4 PH3362GM258 9380 676 223 PH3362GH258 9380 676 223 PH3362GV258 11610 681 334362 264 211.2 PH3362GM264 9380 691 223 PH3362GH264 9380 691 223 PH3362GV264 11610 697 334362 276 220.8 PH3362GM276 9380 722 223 PH3362GH276 9380 722 223 PH3362GV276 11610 728 334362 288 230.4 PH3362GM288 8740 749 44 PH3362GH288 9380 753 223 PH3362GV288 11610 759 334420 312 249.6 PH3420GM312 9380 811 223 PH3420GH312 10860 815 333 PH3420GV312 13110 820 444420 330 264.0 PH3420GM330 10120 860 233 PH3420GH330 10860 862 333 PH3420GV330 13110 867 444420 336 268.8 PH3420GM336 10120 876 233 PH3420GH336 10860 878 333 PH3420GV336 13110 883 444420 360 288.0 PH3420GM360 10860 940 333 PH3420GH360 10860 940 333 PH3420GV360 13110 945 444420 372 297.6 PH3420GM372 10860 971 333 PH3420GH372 10860 971 333 PH3420GV372 13110 976 444420 378 302.4 PH3420GM378 10860 987 333 PH3420GH378 10860 987 333 PH3420GV378 13110 992 444420 390 312.0 PH3420GM390 11610 1020 334 PH3420GH390 11610 1020 334 PH3420GV390 13110 1023 444420 396 316.8 PH3420GM396 11610 1035 334 PH3420GH396 11610 1035 334 PH3420GV396 13110 1039 444420 420 336.0 PH3420GM420 12360 1099 344 PH3420GH420 12360 1099 344 PH3420GV420 13110 1101 444

* Front-of-Wave 0.5µs Steep Current Impulse Residual Voltage at Specified Current

PH3 Standard Pollution Levels

Page 23: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-23

HUBBELL®

Power Systems

®

HousingCode

Creepmm

Heightmm

BIL W/SkV

SI W/SkV

PF 1 min wet

kVrms

1 2130 824 377 273 173

2 2880 984 472 342 234

3 3620 1180 589 427 294

4 4370 1350 690 500 355

12 5010 1808 849 615 407

22 5760 1968 944 684 468

23 6500 2164 1061 769 528

33 7240 2360 1178 853 588

34 7990 2530 1279 927 649

44 8740 2700 1380 1000 710

223 9380 3148 1533 1111 762

233 10120 3344 1650 1196 822

333 10860 3540 1767 1280 882

334 11610 3710 1868 1353 943

344 12360 3880 1969 1427 1004

444 13110 4050 2070 1500 1065

PH3 Insulation Withstand Values

BIL W/S Basic Insulation Level WithstandSI W/S Switching Impulse WithstandPF 1min wet Power Frequency Withstand, 1 minute wet

Page 24: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-24®

PH4Polymer Housed

IEC Class 4 Arrester

Standard Ground Terminal

Standard Suspension Cap

*NOTE: 17 mm hole used for lifting hook.

Page 25: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-25

HUBBELL®

Power Systems

®

PH4 Protective Characteristics

UrkV

UckV

Temporary Over-Voltage Withstand at indicated duration

Max 36/90 Switching Impulse Residual Voltage at indicated

current

Max 8/20 Lightning Impulse Residual Voltage at indicated current

1s 10s 100s 0.5kA 1kA 2kA 3kA 1.5kA 3kA 5kA 10kA 20kA 40kA

kVrms kVrms kVrms kV kV kV kV kV kV kV kV kV kV

27 21.6 31 30 27 51 52 55 57 55 58 59 63 68 76

30 24.0 35 33 31 57 58 61 63 61 64 66 70 76 85

33 26.4 38 36 34 62 64 67 69 68 71 72 77 84 93

36 28.8 41 39 37 68 70 73 76 74 77 79 84 91 102

39 31.2 45 43 40 74 76 79 82 80 83 85 91 99 110

42 33.6 48 46 43 79 81 85 88 86 90 92 99 106 119

48 38.4 55 53 49 91 93 97 101 98 103 105 113 122 135

51 40.8 59 56 52 96 99 103 107 104 109 112 120 129 144

54 43.2 62 59 55 102 105 109 114 111 115 118 127 137 152

60 48.0 69 66 61 113 116 121 126 123 128 131 141 152 169

66 52.8 76 72 67 125 128 133 139 135 141 144 155 167 186

72 57.6 83 79 73 136 140 145 152 148 154 158 169 183 203

75 60.0 86 82 76 142 145 152 158 154 160 164 176 190 212

78 62.4 90 86 79 148 151 158 164 160 167 171 183 198 220

81 64.8 93 89 82 153 157 164 170 166 173 177 190 205 229

84 67.2 97 92 85 159 163 170 177 172 180 184 197 213 237

90 72.0 104 99 92 170 175 182 189 184 192 197 211 228 254

96 76.8 111 105 98 182 186 194 202 197 205 210 225 243 271

108 86.4 124 118 110 204 209 218 227 221 231 236 253 274 305

120 96.0 138 132 122 227 233 242 253 246 256 263 281 304 339

132 105.6 152 145 134 250 256 267 278 270 282 289 310 335 372

138 110.4 158 149 140 261 268 279 290 283 295 302 324 350 389

144 115.2 166 158 146 272 279 291 303 295 308 315 338 365 406

162 129.6 187 178 165 306 314 327 341 332 346 354 380 411 457168 134.4 194 184 171 318 326 339 354 344 359 368 394 426 474

180 144.0 207 197 183 340 349 364 379 369 385 394 422 456 508

192 153.6 221 211 195 363 372 388 404 393 410 420 450 487 542

198 158.4 228 217 201 375 384 400 417 406 423 433 464 502 559

216 172.8 249 237 220 409 419 436 455 443 462 473 507 548 610

228 182.4 263 250 232 431 442 461 480 467 487 499 535 578 643

240 192.0 276 263 244 454 466 485 505 492 513 525 563 609 677

258 206.4 297 283 262 488 500 521 543 529 551 565 605 654 728

264 211.2 304 290 268 499 512 533 556 541 564 578 619 669 745

276 220.8 318 303 281 522 535 558 581 565 590 604 647 700 779

288 230.4 332 316 293 545 559 582 606 590 616 630 675 730 813

312 249.6 359 342 317 590 605 630 657 639 667 683 732 791 880

330 264.0 380 362 336 624 640 667 694 676 705 722 774 837 931

336 268.8 387 369 342 636 652 679 707 688 718 735 788 852 948

360 288.0 415 395 366 681 698 727 758 738 769 788 844 913 1016

372 297.6 429 408 378 704 722 752 783 762 795 814 872 943 1050

378 302.4 435 415 384 715 733 764 795 774 808 827 887 958 1067

390 312.0 449 428 397 738 756 788 821 799 834 853 915 989 1101

396 316.8 456 434 403 749 768 800 833 811 846 866 929 1004 1117

420 336.0 484 461 427 794 815 849 884 860 898 919 985 1065 1185

Page 26: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-26®

PH4 Physical Characteristics

Table continued on next page.

Catalog #Um(kV)

Ur(kV)

Uc(kV)

(M)edium pollution (H)eavy pollution (V)ery heavy pollution

Creepage Distance

(mm)

Height “H”

(mm)

PH4 Figure

Number

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

PH4 Figure

Number

Weight (kg)

Creepage Distance

(mm)

Height “H” (mm)

PH4 Figure

Number

Weight (kg)

PH4036G*024AA

36

24 19.2 2130 967 1 46 2130 967 1 46 2130 967 1 46

PH4036G*030AA 30 24.0 2130 967 1 45 2130 967 1 45 2130 967 1 45

PH4036G*033AA 33 26.4 2130 967 1 46 2130 967 1 46 2130 967 1 46

PH4036G*036AA 36 28.8 2130 967 1 46 2130 967 1 46 2130 967 1 46

PH4036G*039AA 39 31.2 2130 967 1 47 2130 967 1 47 2130 967 1 47

PH4052G*042AA

52

42 33.6 2130 967 1 47 2130 967 1 47 2130 967 1 47

PH4052G*048AA 48 38.4 2130 967 1 49 2130 967 1 49 2130 967 1 49

PH4052G*051AA 51 40.8 2130 967 1 51 2130 967 1 51 2130 967 1 51

PH4052G*054AA 54 43.2 2130 967 1 50 2130 967 1 50 2130 967 1 50

PH4052G*060AA 60 48.0 2130 967 1 51 2130 967 1 51 2130 967 1 51

PH4072G*054AA

72

54 43.2 2130 967 1 50 2130 967 1 50 2880 1127 1 52

PH4072G*060AA 60 48.0 2130 967 1 51 2130 967 1 51 2880 1127 1 53

PH4072G*066AA 66 52.8 2130 967 1 52 2130 967 1 52 2880 1127 1 55

PH4072G*072AA 72 57.6 2130 967 1 53 2130 967 1 53 2880 1127 1 56

PH4072G*075AA 75 60.0 2130 967 1 56 2130 967 1 56 2880 1127 1 58

PH4072G*078AA 78 62.4 2130 967 1 54 2130 967 1 54 2880 1127 1 57

PH4072G*081AA 81 64.8 2130 967 1 57 2130 967 1 57 2880 1127 1 59

PH4072G*084AA 84 67.2 2880 1127 1 58 2880 1127 1 58 2880 1127 1 58

PH4100G*084AA

100

84 67.2 2880 1127 1 58 2880 1127 1 58 3620 1323 1 62

PH4100G*090AA 90 72.0 2880 1127 1 59 2880 1127 1 59 3620 1323 1 63

PH4100G*096AA 96 76.8 2880 1127 1 62 2880 1127 1 62 3620 1323 1 66

PH4123G*090AA

123

90 72.0 2880 1127 1 59 3620 1323 1 63 4370 1493 1 67

PH4123G*096AA 96 76.8 2880 1127 1 62 3620 1323 1 66 4370 1493 1 70

PH4123G*108AA 108 86.4 3620 1323 1 68 3620 1323 1 68 4370 1493 1 72

PH4123G*120AA 120 96.0 3620 1323 1 70 3620 1323 1 70 4370 1493 1 75

PH4123G*132AA 132 105.6 4370 1493 1 77 4370 1493 1 77 4370 1493 1 77

PH4123G*138AA 138 110.4 4370 1493 1 78 4370 1493 1 78 4370 1493 1 78

PH4145G*108AA

145

108 86.4 3620 1323 1 68 4370 1493 1 72 5010 1951 2 97

PH4145G*120AA 120 96.0 3620 1323 1 70 4370 1493 1 75 5010 1951 2 99

PH4145G*132AA 132 105.6 4370 1493 1 77 4370 1493 1 77 5010 1951 2 102

PH4145G*138AA 138 110.4 4370 1493 1 78 4370 1493 1 78 5010 1951 2 103

PH4145G*144AA 144 115.2 4370 1493 1 79 4370 1493 1 79 5010 1951 2 104

NOTE: The * is replaced by M for Medium Pollution, H for Heavy Pollution, or V for Very Heavy Pollution.

Page 27: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-27

HUBBELL®

Power Systems

®

PH4 Physical Characteristics (continued)

Catalog #Um(kV)

Ur(kV)

Uc(kV)

(M)edium pollution (H)eavy pollution (V)ery heavy pollution

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring Dia. “D” (mm)

PH4 Fig. No.

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring Dia. “D” (mm)

PH4 Fig. No.

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring

Dia. “D” (mm)

PH4 Fig. No.

Weight (kg)

PH4170G*132AA

170

132 105.6 4370 1493 n/a 1 77 4370 1493 n/a 1 77 5760 2111 640 3 112

PH4170G*144AA 144 115.2 4370 1493 n/a 1 79 4370 1493 n/a 1 79 5760 2111 640 3 114

PH4170G*162AA 162 129.6 5010 1951 n/a 2 109 5010 1951 n/a 2 109 5760 2111 n/a 2 111

PH4170G*168AA 168 134.4 5010 1951 n/a 2 110 5010 1951 n/a 2 110 5760 2111 n/a 2 112

PH4245G*180AA

245

180 144.0 5010 1951 640 3 120 6500 2307 990 3 130 7990 2673 990 3 138

PH4245G*192AA 192 153.6 5760 2111 640 3 125 6500 2307 640 3 129 7990 2673 990 3 141

PH4245G*198AA 198 158.4 5760 2111 640 3 127 6500 2307 640 3 130 7990 2673 990 3 142

PH4245G*216AA 216 172.8 6500 2307 640 3 134 6500 2307 640 3 134 7990 2673 640 3 142

PH4245G*228AA 228 182.4 6500 2307 640 3 137 6500 2307 640 3 137 7990 2673 640 3 144

PH4300G*216AA

300

216 172.8 6500 2307 990 3 137 7990 2673 1530 3 154 9380 3291 1530 4 182

PH4300G*228AA 228 182.4 6500 2307 990 3 141 7990 2673 1530 3 156 9380 3291 1530 4 185

PH4300G*240AA 240 192.0 7240 2503 990 3 147 7990 2673 990 3 151 9380 3291 1530 4 187

PH4300G*258AA 258 206.4 7990 2673 990 3 155 7990 2673 990 3 155 9380 3291 990 4 182

PH4300G*264AA 264 211.2 7990 2673 990 3 156 7990 2673 990 3 156 9380 3291 990 4 183

PH4362G*258AA

362

258 206.4 7990 2673 990 3 163 9380 3291 1530 3 190 11610 3853 2030 4 222

PH4362G*264AA 264 211.2 7990 2673 990 3 164 9380 3291 1530 3 192 11610 3853 2030 4 224

PH4362G*276AA 276 220.8 7990 2673 990 3 167 9380 3291 1530 3 194 11610 3853 1530 4 206

PH4362G*288AA 288 230.4 8740 2843 990 3 174 9380 3291 1530 3 196 11610 3853 1530 4 208

PH4420G*312AA

420

312 249.6 9380 3291 1530 4 202 10860 3683 1530 4 210 13110 4193 2030 4 243

PH4420G*330AA 330 264.0 9380 3291 1530 4 207 10860 3683 1530 4 214 13110 4193 1530 4 226

PH4420G*336AA 336 268.8 10120 3487 1530 4 211 10860 3683 1530 4 215 13110 4193 1530 4 228

PH4420G*360AA 360 288.0 10860 3683 1530 4 221 10860 3683 1530 4 221 13110 4193 1530 4 232

PH4420G*372AA 372 297.6 10860 3683 1530 4 223 10860 3683 1530 4 223 13110 4193 1530 4 236

PH4420G*378AA 378 302.4 10860 3683 1530 4 224 10860 3683 1530 4 224 13110 4193 1530 4 237

PH4420G*390AA 390 312.0 11610 3853 1530 4 231 11610 3853 1530 4 231 13110 4193 1530 4 239

PH4420G*396AA 396 316.8 11610 3853 1530 4 232 11610 3853 1530 4 232 13110 4193 990 4 232

PH4420G*420AA 420 336.0 12360 4023 990 4 232 12360 4023 990 4 232 13110 4193 990 4 237

NOTE: The * is replaced by M for Medium Pollution, H for Heavy Pollution, or V for Very Heavy Pollution.

Page 28: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-28®

Max System Voltage

Rated Voltage

Max Continuous Voltage L-G

PH4 standard pollution ratings

Medium Heavy Very Heavy

Um Ur Uc Catalog Creep (mm)

20KA FOW* (kV)

Housing Code Catalog Creep

(mm)

20KA FOW* (kV)

Housing Code Catalog Creep

(mm)

20KA FOW* (kV)

Housing Code

36 27 21.6 PH4036GM027 2130 91 1 PH4036GH027 2130 91 1 PH4036GV027 2130 91 136 30 24.0 PH4036GM030 2130 99 1 PH4036GH030 2130 99 1 PH4036GV030 2130 99 136 33 26.4 PH4036GM033 2130 107 1 PH4036GH033 2130 107 1 PH4036GV033 2130 107 136 36 28.8 PH4036GM036 2130 115 1 PH4036GH036 2130 115 1 PH4036GV036 2130 115 136 39 31.2 PH4036GM039 2130 122 1 PH4036GH039 2130 122 1 PH4036GV039 2130 122 152 42 33.6 PH4052GM042 2130 130 1 PH4052GH042 2130 130 1 PH4052GV042 2130 130 152 48 38.4 PH4052GM048 2130 146 1 PH4052GH048 2130 146 1 PH4052GV048 2130 146 152 51 40.8 PH4052GM051 2130 154 1 PH4052GH051 2130 154 1 PH4052GV051 2130 154 152 54 43.2 PH4052GM054 2130 162 1 PH4052GH054 2130 162 1 PH4052GV054 2130 162 152 60 48.0 PH4052GM060 2130 178 1 PH4052GH060 2130 178 1 PH4052GV060 2130 178 172 54 43.2 PH4072GM054 2130 162 1 PH4072GH054 2130 162 1 PH4072GV054 2880 165 272 60 48.0 PH4072GM060 2130 178 1 PH4072GH060 2130 178 1 PH4072GV060 2880 181 272 66 52.8 PH4072GM066 2130 194 1 PH4072GH066 2130 194 1 PH4072GV066 2880 197 272 72 57.6 PH4072GM072 2130 210 1 PH4072GH072 2130 210 1 PH4072GV072 2880 213 272 75 60.0 PH4072GM075 2130 218 1 PH4072GH075 2130 218 1 PH4072GV075 2880 221 272 78 62.4 PH4072GM078 2130 226 1 PH4072GH078 2130 226 1 PH4072GV078 2880 229 272 81 64.8 PH4072GM081 2130 234 1 PH4072GH081 2130 234 1 PH4072GV081 2880 237 272 84 67.2 PH4072GM084 2880 245 2 PH4072GH084 2880 245 2 PH4072GV084 2880 245 2100 84 67.2 PH4100GM084 2880 245 2 PH4100GH084 2880 245 2 PH4100GV084 3620 249 3100 90 72.0 PH4100GM090 2880 261 2 PH4100GH090 2880 261 2 PH4100GV090 3620 264 3100 96 76.8 PH4100GM096 2880 276 2 PH4100GH096 2880 276 2 PH4100GV096 3620 280 3123 90 72.0 PH4123GM090 2880 261 2 PH4123GH090 3620 264 3 PH4123GV090 4370 268 4123 96 76.8 PH4123GM096 2880 276 2 PH4123GH096 3620 280 3 PH4123GV096 4370 284 4123 108 86.4 PH4123GM108 3620 312 3 PH4123GH108 3620 312 3 PH4123GV108 4370 315 4123 120 96.0 PH4123GM120 3620 344 3 PH4123GH120 3620 344 3 PH4123GV120 4370 347 4123 132 105.6 PH4123GM132 4370 379 4 PH4123GH132 4370 379 4 PH4123GV132 4370 379 4123 138 110.4 PH4123GM138 4370 395 4 PH4123GH138 4370 395 4 PH4123GV138 4370 395 4145 108 86.4 PH4145GM108 3620 312 3 PH4145GH108 4370 315 4 PH4145GV108 5010 325 12145 120 96.0 PH4145GM120 3620 344 3 PH4145GH120 4370 347 4 PH4145GV120 5010 356 12145 132 105.6 PH4145GM132 4370 379 4 PH4145GH132 4370 379 4 PH4145GV132 5010 388 12145 138 110.4 PH4145GM138 4370 395 4 PH4145GH138 4370 395 4 PH4145GV138 5010 404 12145 144 115.2 PH4145GM144 4370 411 4 PH4145GH144 4370 411 4 PH4145GV144 5010 420 12170 132 105.6 PH4170GM132 4370 379 4 PH4170GH132 4370 379 4 PH4170GV132 5760 391 22170 144 115.2 PH4170GM144 4370 411 4 PH4170GH144 4370 411 4 PH4170GV144 5760 423 22170 162 129.6 PH4170GM162 5010 467 12 PH4170GH162 5010 467 12 PH4170GV162 5760 471 22170 168 134.4 PH4170GM168 5010 483 12 PH4170GH168 5010 483 12 PH4170GV168 5760 487 22245 180 144.0 PH4245GM180 5010 515 12 PH4245GH180 6500 522 23 PH4245GV180 7990 529 34245 192 153.6 PH4245GM192 5760 550 22 PH4245GH192 6500 554 23 PH4245GV192 7990 561 34245 198 158.4 PH4245GM198 5760 566 22 PH4245GH198 6500 570 23 PH4245GV198 7990 577 34245 216 172.8 PH4245GM216 6500 617 23 PH4245GH216 6500 617 23 PH4245GV216 7990 625 34245 228 182.4 PH4245GM228 6500 649 23 PH4245GH228 6500 649 23 PH4245GV228 7990 656 34300 216 172.8 PH4300GM216 6500 617 23 PH4300GH216 7990 625 34 PH4300GV216 9380 637 223300 228 182.4 PH4300GM228 6500 649 23 PH4300GH228 7990 656 34 PH4300GV228 9380 669 223300 240 192.0 PH4300GM240 7240 685 33 PH4300GH240 7990 688 34 PH4300GV240 9380 701 223300 258 206.4 PH4300GM258 7990 736 34 PH4300GH258 7990 736 34 PH4300GV258 9380 748 223300 264 211.2 PH4300GM264 7990 752 34 PH4300GH264 7990 752 34 PH4300GV264 9380 764 223362 258 206.4 PH4362GM258 7990 736 34 PH4362GH258 9380 748 223 PH4362GV258 11610 759 334362 264 211.2 PH4362GM264 7990 752 34 PH4362GH264 9380 764 223 PH4362GV264 11610 775 334362 276 220.8 PH4362GM276 7990 783 34 PH4362GH276 9380 796 223 PH4362GV276 11610 807 334362 288 230.4 PH4362GM288 8740 818 44 PH4362GH288 9380 827 223 PH4362GV288 11610 839 334420 312 249.6 PH4420GM312 9380 891 223 PH4420GH312 10860 899 333 PH4420GV312 13110 909 444420 330 264.0 PH4420GM330 9380 939 223 PH4420GH330 10860 946 333 PH4420GV330 13110 957 444420 336 268.8 PH4420GM336 10120 958 233 PH4420GH336 10860 962 333 PH4420GV336 13110 972 444420 360 288.0 PH4420GM360 10860 1026 333 PH4420GH360 10860 1026 333 PH4420GV360 13110 1036 444420 372 297.6 PH4420GM372 10860 1057 333 PH4420GH372 10860 1057 333 PH4420GV372 13110 1068 444420 378 302.4 PH4420GM378 10860 1073 333 PH4420GH378 10860 1073 333 PH4420GV378 13110 1084 444420 390 312.0 PH4420GM390 11610 1108 334 PH4420GH390 11610 1108 334 PH4420GV390 13110 1115 444420 396 316.8 PH4420GM396 11610 1124 334 PH4420GH396 11610 1124 334 PH4420GV396 13110 1131 444420 420 336.0 PH4420GM420 12360 1191 344 PH4420GH420 12360 1191 344 PH4420GV420 13110 1195 444

* Front-of-Wave 0.5µs Steep Current Impulse Residual Voltage at Specified Current

PH4 Standard Pollution Levels

Page 29: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-29

HUBBELL®

Power Systems

®

HousingCode

Creepmm

Heightmm

BIL W/SkV

SI W/SkV

PF 1 min wet

kVrms

1 2130 824 377 273 173

2 2880 984 472 342 234

3 3620 1180 589 427 294

4 4370 1350 690 500 355

12 5010 1808 849 615 407

22 5760 1968 944 684 468

23 6500 2164 1061 769 528

33 7240 2360 1178 853 588

34 7990 2530 1279 927 649

44 8740 2700 1380 1000 710

223 9380 3148 1533 1111 762

233 10120 3344 1650 1196 822

333 10860 3540 1767 1280 882

334 11610 3710 1868 1353 943

344 12360 3880 1969 1427 1004

444 13110 4050 2070 1500 1065

PH4 Insulation Withstand Values

BIL W/S Basic Insulation Level WithstandSI W/S Switching Impulse WithstandPF 1min wet Power Frequency Withstand, 1 minute wet

Page 30: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-30®

Porcelain Housed Arresters(Type H3, H4 & H5)

Construction• Rigid, high strength porcelain

housing with a long service history

• Compression spring ensures a consistent electrical connec-tion between blocks

• Pressure relief rupture plate ensures the housing will vent out the end of the arrester and through the pressure relief vent.

• Directional Venting: Arc will be directed to the side of the arrester through the pressure relief vent.

• Vacuum Sealed: Arrester goes through double leak test to verify complete seal.

Product TypeHousing Material

Line Discharge

Class

VoltageRating Range

(kV)

Pressure Relief (kA)

Cantilever Strength*

(N.m)

H3 Porcelain 3 24-420 63 8,000

H4 Porcelain 4 24-420 63 17,000

H5 Porcelain 5 550-800 63 31,000

Table 14: Porcelain Overview

* MPDSL – Maximum Permissible Dynamic Service Load

Page 31: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-31

HUBBELL®

Power Systems

®

Use the following selection tables to build the correct Ohio Brass H3 and H4 Arresters. Please see H5 information on page 204-37 to find available H5 Arresters.

Step 1: Select the correct arrester line discharge class from Table 15 and fill in B.

Ohio Brass Porcelain Ordering System:

Step 2: Select the Max System Voltage (Um) from Table 16 and fill in Cells C through E.

Step 3: Select the appropriate Porcelain Color from Table 17 and fill in F.

Step 4: Select the appropriate Pollution level from Table 18 and fill in G.

Catalog Ordering System A B C D E F G H I J K L H

Table 15

Table 16

Table 17

Table 18

Arrester Class BClass 3 - H3 Arrester 3

Class 4 - H4 Arrester 4

Porcelain Color FGrey G

Brown B

Max System Voltage (kV)

C D E

36 0 3 6

52 0 5 2

72 0 7 2

100 1 0 0

123 1 2 3

145 1 4 5

170 1 7 0

245 2 4 5

300 3 0 0

362 3 6 2

420 4 2 0

NOTE: Pollution levels per IEC - 60099-4

Page 32: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-32®

Step 5: Select the appropriate Rated Voltage (Ur) from Table 19 that corresponds with the Max System voltage selected for C through E and fill in Cells H through J.

Max System Voltage (kV)

Rated Voltage

(kV)H I J

36

24 0 2 430 0 3 033 0 3 336 0 3 639 0 3 9

52

42 0 4 248 0 4 851 0 5 154 0 5 460 0 6 0

72

54 0 5 460 0 6 066 0 6 672 0 7 275 0 7 578 0 7 881 0 8 184 0 8 4

10084 0 8 490 0 9 096 0 9 6

123

90 0 9 096 0 9 6108 1 0 8120 1 2 0132 1 3 2138 1 3 8

145

108 1 0 8120 1 2 0132 1 3 2138 1 3 8144 1 4 4

Table 19

170

132 1 3 2144 1 4 4162 1 6 2168 1 6 8

245

180 1 8 0192 1 9 2198 1 9 8216 2 1 6228 2 2 8

300

216 2 1 6228 2 2 8240 2 4 0258 2 5 8264 2 6 4

362

258 2 5 8264 2 6 4276 2 7 6288 2 8 8

420

312 3 1 2330 3 3 0336 3 3 6360 3 6 0372 3 7 2378 3 7 8390 3 9 0396 3 9 6420 4 2 0

Step 6: Select the appropriate Line and Ground termi-nals based on the conductor size ranges in Table 20 and fill in K & L.

Table 20Line Size

(mm2)Ground Size

(mm2)K L

25 - 240

25 - 240 A A

70 - 630 A B

500 - 1000 A C

70 - 630

25 - 240 B A

70 - 630 B B

500 - 1000 B C

500 - 1000

25 - 240 C A

70 - 630 C B

500 - 1000 C C

H3 Catalog Ordering Example• Max System Voltage – 72kV• Grey Porcelain• Medium Pollution Level• Rated Voltage – 60 kV• Line & Ground Size - 25 to 240mm

Step 1: Use Max system Voltage to fill in C through E – 145kV v (H3072xxxxxxx)

Step 2: Select Grey Porcelain – G v (H3072Gxxxxxx)

Step 3: Select Medium Pollution – M v (H3072GMxxxxx)

Step 4: Select Rated Voltage – 60kV v (H3072GM060xx)

Step 5: Select correct terminals v (H3072GM060AA)

Step 6: Order Ohio Brass Catalog Number v H3072GM060AA

H4 Catalog Ordering Example• Max System Voltage – 145kV• Grey Porcelain• Heavy Pollution Level• Rated Voltage – 120 kV• Line & Ground Size - 25 to 240mm

Step 1: Use Max system Voltage to fill in C through E – 145kV v (H4145xxxxxxx)

Step 2: Select Grey Porcelain – G v (H4145Gxxxxxx)

Step 3: Select Heavy Pollution – H v (H4145GHxxxxx)

Step 4: Select Rated Voltage – 120kV v (H4145GH120xx)

Step 5: Select correct terminals v (H4145GH120AA)

Step 6: Order Ohio Brass Catalog Number v H4145GH120AA

Page 33: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-33

HUBBELL®

Power Systems

®

H3Porcelain Housed

IEC Class 3 Arrester

Standard Ground Terminal

Standard Suspension Cap

*NOTE: 17 mm hole used for lifting hook.

Page 34: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-34®

H3 Protective Characteristics

UrkV

UckV

Temporary Over-Voltage Withstand at indicated

duration

Max 36/90 Switching Impulse Residual Voltage at indicated current

Max 8/20 Lightning Impulse Residual Voltage at indicated current

1s 10s 100s 0.25kA 0.5kA 1kA 2kA 1.5kA 3kA 5kA 10kA 20kA 40kA

kVrms kVrms kVrms kV kV kV kV kV kV kV kV kV kV

27 21.6 31 30 27 50 51 53 55 55 57 60 64 70 79

30 24.0 35 33 30 55 56 59 61 61 63 67 71 77 87

33 26.4 38 36 33 61 62 65 68 67 70 73 78 85 96

36 28.8 42 40 36 66 68 71 74 73 76 80 85 93 105

39 31.2 45 43 39 72 73 77 80 79 82 87 92 101 114

42 33.6 49 46 42 78 79 83 86 85 88 93 99 108 122

48 38.4 56 53 48 89 90 94 98 97 101 107 114 124 140

51 40.8 59 56 51 94 96 100 104 103 107 113 121 132 148

54 43.2 63 59 54 100 102 106 111 109 114 120 128 139 157

60 48.0 69 66 60 111 113 118 123 121 126 134 142 155 175

66 52.8 76 73 66 122 124 130 135 134 139 147 156 170 192

72 57.6 83 79 72 133 135 141 147 146 152 160 170 186 210

75 60.0 87 83 75 138 141 147 154 152 158 167 178 194 218

78 62.4 90 86 78 144 147 153 160 158 164 174 185 201 227

81 64.8 94 89 81 150 152 159 166 164 171 180 192 209 236

84 67.2 97 92 84 155 158 165 172 170 177 187 199 217 245

90 72.0 104 99 90 166 169 177 184 182 190 200 213 232 262

96 76.8 111 106 96 177 181 189 197 194 202 214 227 248 279

108 86.4 125 119 109 199 203 212 221 219 228 240 256 279 314

120 96.0 139 132 121 222 226 236 246 243 253 267 284 310 349

132 105.6 153 145 133 244 248 259 270 267 278 294 312 341 384

138 110.4 160 152 139 255 260 271 283 279 291 307 327 356 402

144 115.2 167 158 145 266 271 283 295 291 303 320 341 372 419

162 129.6 188 178 163 299 305 318 332 328 341 360 383 418 472168 134.4 195 185 169 310 316 330 344 340 354 374 398 433 489

180 144.0 208 198 181 332 339 354 369 364 379 401 426 464 524

192 153.6 222 211 193 354 361 377 393 389 404 427 454 495 559

198 158.4 229 218 199 366 373 389 405 401 417 441 469 511 576

216 172.8 250 238 217 399 406 424 442 437 455 481 511 557 629

228 182.4 264 251 229 421 429 448 467 461 480 507 540 588 664

240 192.0 278 264 241 443 452 472 491 486 506 534 568 619 699

258 206.4 299 284 259 476 486 507 528 522 544 574 611 666 751

264 211.2 306 290 265 487 497 519 541 534 556 587 625 681 769

276 220.8 320 304 277 510 519 542 565 559 581 614 653 712 804

288 230.4 334 317 289 532 542 566 590 583 607 641 682 743 838

312 249.6 361 343 314 576 587 613 639 631 657 694 739 805 908

330 264.0 382 363 332 609 621 648 676 668 695 734 781 851 961

336 268.8 389 370 338 620 632 660 688 680 708 748 795 867 978

360 288.0 417 396 362 665 677 707 737 729 758 801 852 929 1048

372 297.6 431 409 374 687 700 731 762 753 784 828 881 960 1083

378 302.4 438 416 380 698 711 743 774 765 796 841 895 975 1101

390 312.0 452 429 392 720 734 766 799 789 822 868 923 1006 1135

396 316.8 459 436 398 731 745 778 811 801 834 881 937 1022 1153

420 336.0 486 462 422 775 790 825 860 850 885 935 994 1084 1223

Page 35: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-35

HUBBELL®

Power Systems

®

H3 Physical Characteristics

Catalog #Um(kV)

Ur(kV)

Uc(kV)

(M)edium pollution (H)eavy pollution (V)ery heavy pollution

Creepage Distance

(mm)

Height “H”

(mm)

H3 Figure

Number

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

H3 Figure

Number

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring

Dia. “D” (mm)

H3 Figure

Number

Weight (kg)

H3036G*024AA

36

24 19.2 1106 764 1 63 1106 764 1 63 1883 980 n/a 1 77

H3036G*030AA 30 24.0 1106 764 1 64 1106 764 1 64 1883 980 n/a 1 78

H3036G*033AA 33 26.4 1106 764 1 64 1106 764 1 64 1883 980 n/a 1 78

H3036G*036AA 36 28.8 1106 764 1 65 1106 764 1 65 1883 980 n/a 1 78

H3036G*039AA 39 31.2 1106 764 1 65 1106 764 1 65 1883 980 n/a 1 79

H3052G*042AA

52

42 33.6 1106 764 1 65 1883 980 1 79 1883 980 n/a 1 79

H3052G*048AA 48 38.4 1106 764 1 66 1883 980 1 80 1883 980 n/a 1 80

H3052G*051AA 51 40.8 1106 764 1 67 1883 980 1 80 1883 980 n/a 1 80

H3052G*054AA 54 43.2 1106 764 1 67 1883 980 1 81 1883 980 n/a 1 81

H3052G*060AA 60 48.0 1883 980 1 82 1883 980 1 82 1883 980 n/a 1 82

H3072G*054AA

72

54 43.2 1883 980 1 81 1883 980 1 81 2660 1196 n/a 1 94

H3072G*060AA 60 48.0 1883 980 1 82 1883 980 1 82 2660 1196 n/a 1 96

H3072G*066AA 66 52.8 1883 980 1 83 1883 980 1 83 2660 1196 n/a 1 96

H3072G*072AA 72 57.6 1883 980 1 83 1883 980 1 83 2660 1196 n/a 1 97

H3072G*075AA 75 60.0 1883 980 1 84 1883 980 1 84 2660 1196 n/a 1 97

H3072G*078AA 78 62.4 1883 980 1 84 1883 980 1 84 2660 1196 n/a 1 98

H3072G*081AA 81 64.8 1883 980 1 84 1883 980 1 84 2660 1196 n/a 1 98

H3072G*084AA 84 67.2 2660 1196 1 99 2660 1196 1 99 2660 1196 n/a 1 99

H3100G*084AA

100

84 67.2 2660 1196 1 99 2660 1196 1 99 3696 1484 n/a 1 117

H3100G*090AA 90 72.0 2660 1196 1 100 2660 1196 1 100 3696 1484 n/a 1 118

H3100G*096AA 96 76.8 2660 1196 1 100 2660 1196 1 100 3696 1484 n/a 1 119

H3123G*090AA

123

90 72.0 2660 1196 1 100 3696 1484 1 118 4543 2033 640 3 171

H3123G*096AA 96 76.8 2660 1196 1 100 3696 1484 1 119 4543 2033 640 3 172

H3123G*108AA 108 86.4 2660 1196 1 102 3696 1484 1 120 4543 2033 n/a 2 166

H3123G*120AA 120 96.0 3696 1484 1 122 3696 1484 1 122 4543 2033 n/a 2 168

H3123G*132AA 132 105.6 3696 1484 1 124 3696 1484 1 124 4543 2033 n/a 2 169

H3123G*138AA 138 110.4 3696 1484 1 124 3696 1484 1 124 4543 2033 n/a 2 170

H3145G*108AA

145

108 86.4 3696 1484 1 120 3696 1484 1 120 4543 2033 640 3 174

H3145G*120AA 120 96.0 3696 1484 1 122 3696 1484 1 122 4543 2033 n/a 2 168

H3145G*132AA 132 105.6 3696 1484 1 124 3696 1484 1 124 4543 2033 n/a 2 169

H3145G*138AA 138 110.4 3696 1484 1 124 3696 1484 1 124 4543 2033 n/a 2 170

H3145G*144AA 144 115.2 3696 1484 1 125 3696 1484 1 125 4543 2033 n/a 2 171

Table continued on next page.

NOTE: The * is replaced by M for Medium Pollution, H for Heavy Pollution, or V for Very Heavy Pollution.NOTE: Grey (G) and (AA) Terminal codes used for illustrative purposes.

Page 36: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-36®

H3 Physical Characteristics (continued)

Catalog #Um(kV)

Ur(kV)

Uc(kV)

(M)edium pollution (H)eavy pollution (V)ery heavy pollution

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring

Dia. “D” (mm)

H3 Figure

Number

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring

Dia. “D” (mm)

H3 Figure

Number

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring

Dia. “D” (mm)

H3 Figure

Number

Weight (kg)

H3170G*132AA

170

132 105.6 3696 1484 n/a 1 124 4543 2033 640 3 177 5320 2249 640 3 192

H3170G*144AA 144 115.2 3696 1484 n/a 1 125 4543 2033 n/a 2 171 5320 2249 n/a 2 185

H3170G*162AA 162 129.6 3766 2033 n/a 2 173 4543 2033 n/a 2 174 5320 2249 n/a 2 187

H3170G*168AA 168 134.4 4543 2033 n/a 2 174 4543 2033 n/a 2 174 5320 2249 n/a 2 188

H3245G*180AA

245

180 144.0 5320 2249 640 3 198 6356 2537 990 3 219 7980 3302 1530 4 288

H3245G*192AA 192 153.6 5320 2249 640 3 199 6356 2537 990 3 221 7980 3302 990 4 281

H3245G*198AA 198 158.4 5320 2249 640 3 200 6356 2537 640 3 218 7980 3302 990 4 282

H3245G*216AA 216 172.8 5320 2249 640 3 202 6356 2537 640 3 221 7980 3302 640 4 281

H3245G*228AA 228 182.4 6356 2537 640 3 222 6356 2537 640 3 222 7980 3302 640 4 282

H3300G*216AA

300

216 172.8 6356 2537 990 3 224 8239 3374 1530 4 297 10052 3878 1530 4 329

H3300G*228AA 228 182.4 6356 2537 990 3 226 8239 3374 1530 4 298 10052 3878 1530 4 331

H3300G*240AA 240 192.0 6356 2537 990 3 227 8239 3374 990 4 291 10052 3878 1530 4 332

H3300G*258AA 258 206.4 7392 2825 990 3 248 8239 3374 990 4 294 10052 3878 1530 4 335

H3300G*264AA 264 211.2 7392 2825 990 3 249 8239 3374 990 4 295 10052 3878 1530 4 336

H3362G*258AA

362

258 206.4 7392 2825 990 3 248 9275 3662 1530 4 321 11676 4643 2030 5 415

H3362G*264AA 264 211.2 7392 2825 990 3 249 9275 3662 1530 4 322 11676 4643 2030 5 415

H3362G*276AA 276 220.8 7392 2825 990 3 251 9275 3662 1530 4 323 11676 4643 1530 5 398

H3362G*288AA 288 230.4 7392 2825 990 3 252 9275 3662 1530 4 325 11676 4643 1530 5 399

H3420G*312AA

420

312 249.6 8498 3446 1530 4 314 11088 4166 1530 4 360 13748 5219 2030 5 458

H3420G*330AA 330 264.0 8498 3446 1530 4 317 11088 4166 1530 4 363 13748 5219 2030 5 461

H3420G*336AA 336 268.8 8498 3446 1530 4 318 11088 4166 1530 4 364 13748 5219 2030 5 462

H3420G*360AA 360 288.0 9016 3590 1530 4 330 11088 4166 1530 4 368 13748 5219 2030 5 465

H3420G*372AA 372 297.6 10052 3878 1530 4 350 11088 4166 1530 4 369 13748 5219 1530 5 446

H3420G*378AA 378 302.4 10052 3878 1530 4 351 11088 4166 1530 4 370 13748 5219 1530 5 447

H3420G*390AA 390 312.0 10052 3878 1530 4 353 11088 4166 1530 4 371 13748 5219 1530 5 449

H3420G*396AA 396 316.8 10052 3878 1530 4 353 11088 4166 1530 4 372 13748 5219 1530 5 450

H3420G*420AA 420 336.0 11088 4166 1530 4 375 11088 4166 1530 4 375 13748 5219 1530 5 453

HousingCode

Creepmm

Heightmm

BIL W/SkV

SI W/SkV

PF 1 min wetkVrms

1 1106 519 256 215 102

2 1883 735 370 311 173

3 2660 951 485 408 245

4 3696 1239 621 521 352

13 3766 1470 741 623 347

23 4543 1686 855 719 418

33 5320 1902 970 816 490

34 6356 2190 1106 929 597

44 7392 2478 1242 1042 704

333 7980 2853 1455 1224 735

234 8239 2925 1476 1240 770

144 8498 2997 1498 1257 806

334 9016 3141 1591 1337 842

244 9275 3213 1612 1353 877

344 10052 3429 1727 1450 949

444 11088 3717 1863 1563 1056

3334 11676 4092 2076 1745 1087

3444 13748 4668 2348 1971 1301

H3 Insulation Withstand Values

BIL W/S Basic Insulation Level WithstandSI W/S Switching Impulse WithstandPF 1min wet Power Frequency Withstand, 1 minute wet

NOTE: The * is replaced by M for Medium Pollution, H for Heavy Pollu-tion, or V for Very Heavy Pollution.

NOTE: Grey (G) and (AA) Terminal codes used for illustrative purposes.

Page 37: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-37

HUBBELL®

Power Systems

®

H3 Standard Pollution Levels

Max System Voltage

Rated Voltage

Max Continuous Voltage L-G

H3 standard pollution ratings

Medium Heavy Very Heavy

Um Ur Uc Catalog Creep (mm)

10KA FOW* (kV)

Housing Code Catalog Creep

(mm)

10KA FOW* (kV)

Housing Code Catalog Creep

(mm)

10KA FOW* (kV)

Housing Code

36 27 21.6 H3036GM027 1106 75 1 H3036GH027 1106 75 1 H3036GV027 1883 77 236 30 24.0 H3036GM030 1106 82 1 H3036GH030 1106 82 1 H3036GV030 1883 84 236 33 26.4 H3036GM033 1106 89 1 H3036GH033 1106 89 1 H3036GV033 1883 92 236 36 28.8 H3036GM036 1106 97 1 H3036GH036 1106 97 1 H3036GV036 1883 99 236 39 31.2 H3036GM039 1106 104 1 H3036GH039 1106 104 1 H3036GV039 1883 107 252 42 33.6 H3052GM042 1106 112 1 H3052GH042 1883 114 2 H3052GV042 1883 114 252 48 38.4 H3052GM048 1106 127 1 H3052GH048 1883 129 2 H3052GV048 1883 129 252 51 40.8 H3052GM051 1106 134 1 H3052GH051 1883 136 2 H3052GV051 1883 136 252 54 43.2 H3052GM054 1106 142 1 H3052GH054 1883 144 2 H3052GV054 1883 144 252 60 48.0 H3052GM060 1883 159 2 H3052GH060 1883 159 2 H3052GV060 1883 159 272 54 43.2 H3072GM054 1883 144 2 H3072GH054 1883 144 2 H3072GV054 2660 146 372 60 48.0 H3072GM060 1883 159 2 H3072GH060 1883 159 2 H3072GV060 2660 161 372 66 52.8 H3072GM066 1883 173 2 H3072GH066 1883 173 2 H3072GV066 2660 176 372 72 57.6 H3072GM072 1883 188 2 H3072GH072 1883 188 2 H3072GV072 2660 191 372 75 60.0 H3072GM075 1883 196 2 H3072GH075 1883 196 2 H3072GV075 2660 198 372 78 62.4 H3072GM078 1883 203 2 H3072GH078 1883 203 2 H3072GV078 2660 205 372 81 64.8 H3072GM081 1883 211 2 H3072GH081 1883 211 2 H3072GV081 2660 213 372 84 67.2 H3072GM084 2660 220 3 H3072GH084 2660 220 3 H3072GV084 2660 220 3100 84 67.2 H3100GM084 2660 220 3 H3100GH084 2660 220 3 H3100GV084 3696 223 4100 90 72.0 H3100GM090 2660 235 3 H3100GH090 2660 235 3 H3100GV090 3696 238 4100 96 76.8 H3100GM096 2660 250 3 H3100GH096 2660 250 3 H3100GV096 3696 253 4123 90 72.0 H3123GM090 2660 235 3 H3123GH090 3696 238 4 H3123GV090 4543 244 23123 96 76.8 H3123GM096 2660 250 3 H3123GH096 3696 253 4 H3123GV096 4543 258 23123 108 86.4 H3123GM108 2660 280 3 H3123GH108 3696 283 4 H3123GV108 4543 288 23123 120 96.0 H3123GM120 3696 312 4 H3123GH120 3696 312 4 H3123GV120 4543 318 23123 132 105.6 H3123GM132 3696 342 4 H3123GH132 3696 342 4 H3123GV132 4543 348 23123 138 110.4 H3123GM138 3696 357 4 H3123GH138 3696 357 4 H3123GV138 4543 363 23145 108 86.4 H3145GM108 3696 283 4 H3145GH108 3696 283 4 H3145GV108 4543 288 23145 120 96.0 H3145GM120 3696 312 4 H3145GH120 3696 312 4 H3145GV120 4543 318 23145 132 105.6 H3145GM132 3696 342 4 H3145GH132 3696 342 4 H3145GV132 4543 348 23145 138 110.4 H3145GM138 3696 357 4 H3145GH138 3696 357 4 H3145GV138 4543 363 23145 144 115.2 H3145GM144 3696 372 4 H3145GH144 3696 372 4 H3145GV144 4543 377 23170 132 105.6 H3170GM132 3696 342 4 H3170GH132 4543 348 23 H3170GV132 5320 350 33170 144 115.2 H3170GM144 3696 372 4 H3170GH144 4543 377 23 H3170GV144 5320 380 33170 162 129.6 H3170GM162 3766 420 13 H3170GH162 4543 422 23 H3170GV162 5320 424 33170 168 134.4 H3170GM168 4543 437 23 H3170GH168 4543 437 23 H3170GV168 5320 439 33245 180 144.0 H3245GM180 5320 469 33 H3245GH180 6356 472 34 H3245GV180 7980 479 333245 192 153.6 H3245GM192 5320 499 33 H3245GH192 6356 502 34 H3245GV192 7980 509 333245 198 158.4 H3245GM198 5320 514 33 H3245GH198 6356 516 34 H3245GV198 7980 524 333245 216 172.8 H3245GM216 5320 558 33 H3245GH216 6356 561 34 H3245GV216 7980 569 333245 228 182.4 H3245GM228 6356 591 34 H3245GH228 6356 591 34 H3245GV228 7980 598 333300 216 172.8 H3300GM216 6356 561 34 H3300GH216 8239 569 234 H3300GV216 10052 574 344300 228 182.4 H3300GM228 6356 591 34 H3300GH228 8239 599 234 H3300GV228 10052 604 344300 240 192.0 H3300GM240 6356 621 34 H3300GH240 8239 629 234 H3300GV240 10052 634 344300 258 206.4 H3300GM258 7392 668 44 H3300GH258 8239 674 234 H3300GV258 10052 679 344300 264 211.2 H3300GM264 7392 683 44 H3300GH264 8239 688 234 H3300GV264 10052 694 344362 258 206.4 H3362GM258 7392 668 44 H3362GH258 9275 676 244 H3362GV258 11676 686 3334362 264 211.2 H3362GM264 7392 683 44 H3362GH264 9275 691 244 H3362GV264 11676 701 3334362 276 220.8 H3362GM276 7392 713 44 H3362GH276 9275 721 244 H3362GV276 11676 731 3334362 288 230.4 H3362GM288 7392 742 44 H3362GH288 9275 751 244 H3362GV288 11676 761 3334420 312 249.6 H3420GM312 8498 808 144 H3420GH312 11088 815 444 H3420GV312 13748 826 3444420 330 264.0 H3420GM330 8498 853 144 H3420GH330 11088 860 444 H3420GV330 13748 871 3444420 336 268.8 H3420GM336 8498 868 144 H3420GH336 11088 875 444 H3420GV336 13748 885 3444420 360 288.0 H3420GM360 9016 929 334 H3420GH360 11088 934 444 H3420GV360 13748 945 3444420 372 297.6 H3420GM372 10052 961 344 H3420GH372 11088 964 444 H3420GV372 13748 975 3444420 378 302.4 H3420GM378 10052 976 344 H3420GH378 11088 979 444 H3420GV378 13748 990 3444420 390 312.0 H3420GM390 10052 1006 344 H3420GH390 11088 1009 444 H3420GV390 13748 1019 3444420 396 316.8 H3420GM396 10052 1021 344 H3420GH396 11088 1024 444 H3420GV396 13748 1034 3444420 420 336.0 H3420GM420 11088 1083 444 H3420GH420 11088 1083 444 H3420GV420 13748 1094 3444

* Front-of-Wave 0.5µs Steep Current Impulse Residual Voltage at Specified Current

Page 38: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-38®

H4Porcelain Housed

IEC Class 4 Arrester

Standard Ground Terminal

Standard Suspension Cap

*NOTE: 17 mm hole used for lifting hook.

Page 39: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-39

HUBBELL®

Power Systems

®

H4 Protective Characteristics

UrkV

UckV

Temporary Over-Voltage Withstand at indicated

duration

Max 36/90 Switching Impulse Residual Voltage at indicated

current

Max 8/20 Lightning Impulse Residual Voltage at indicated current

1s 10s 100s 0.5kA 1kA 2kA 3kA 1.5kA 3kA 5kA 10kA 20kA 40kA

kVrms kVrms kVrms kV kV kV kV kV kV kV kV kV kV

27 21.6 31 30 27 51 52 55 57 55 58 59 63 68 76

30 24.0 35 33 31 57 58 61 63 61 64 66 70 76 85

33 26.4 38 36 34 62 64 67 69 68 71 72 77 84 93

36 28.8 41 39 37 68 70 73 76 74 77 79 84 91 102

39 31.2 45 43 40 74 76 79 82 80 83 85 91 99 110

42 33.6 48 46 43 79 81 85 88 86 90 92 99 106 119

48 38.4 55 53 49 91 93 97 101 98 103 105 113 122 135

51 40.8 59 56 52 96 99 103 107 104 109 112 120 129 144

54 43.2 62 59 55 102 105 109 114 111 115 118 127 137 152

60 48.0 69 66 61 113 116 121 126 123 128 131 141 152 169

66 52.8 76 72 67 125 128 133 139 135 141 144 155 167 186

72 57.6 83 79 73 136 140 145 152 148 154 158 169 183 203

75 60.0 86 82 76 142 145 152 158 154 160 164 176 190 212

78 62.4 90 86 79 148 151 158 164 160 167 171 183 198 220

81 64.8 93 89 82 153 157 164 170 166 173 177 190 205 229

84 67.2 97 92 85 159 163 170 177 172 180 184 197 213 237

90 72.0 104 99 92 170 175 182 189 184 192 197 211 228 254

96 76.8 111 105 98 182 186 194 202 197 205 210 225 243 271

108 86.4 124 118 110 204 209 218 227 221 231 236 253 274 305

120 96.0 138 132 122 227 233 242 253 246 256 263 281 304 339

132 105.6 152 145 134 250 256 267 278 270 282 289 310 335 372

138 110.4 159 151 140 261 268 279 290 283 295 302 324 350 389

144 115.2 166 158 146 272 279 291 303 295 308 315 338 365 406

162 129.6 187 178 165 306 314 327 341 332 346 354 380 411 457168 134.4 194 184 171 318 326 339 354 344 359 368 394 426 474

180 144.0 207 197 183 340 349 364 379 369 385 394 422 456 508

192 153.6 221 211 195 363 372 388 404 393 410 420 450 487 542

198 158.4 228 217 201 375 384 400 417 406 423 433 464 502 559

216 172.8 249 237 220 409 419 436 455 443 462 473 507 548 610

228 182.4 263 250 232 431 442 461 480 467 487 499 535 578 643

240 192.0 276 263 244 454 466 485 505 492 513 525 563 609 677

258 206.4 297 283 262 488 500 521 543 529 551 565 605 654 728

264 211.2 304 290 268 499 512 533 556 541 564 578 619 669 745

276 220.8 318 303 281 522 535 558 581 565 590 604 647 700 779

288 230.4 332 316 293 545 559 582 606 590 616 630 675 730 813

312 249.6 359 342 317 590 605 630 657 639 667 683 732 791 880

330 264.0 380 362 336 624 640 667 694 676 705 722 774 837 931

336 268.8 387 369 342 636 652 679 707 688 718 735 788 852 948

360 288.0 415 395 366 681 698 727 758 738 769 788 844 913 1016

372 297.6 429 408 378 704 722 752 783 762 795 814 872 943 1050

378 302.4 435 415 384 715 733 764 795 774 808 827 887 958 1067

390 312.0 449 428 397 738 756 788 821 799 834 853 915 989 1101

396 316.8 456 434 403 749 768 800 833 811 846 866 929 1004 1117

420 336.0 484 461 427 794 815 849 884 860 898 919 985 1065 1185

Page 40: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-40®

H4 Physical Characteristics – Light & Medium Pollution Levels

Catalog # Um(kV)

Ur(kV)

Uc(kV)

(L)ight pollution (M)edium pollution

Creep-age

Distance (mm)

Height “H”

(mm)

H4 Figure

Number

Weight (kg)

Creep-age

Distance (mm)

Height “H”

(mm)

H4 Figure

Number

Weight (kg)

H4036G*024AA

36

24 19.2 1524 968 1 75 1524 968 1 75

H4036G*030AA 30 24.0 1524 968 1 76 1524 968 1 76

H4036G*033AA 33 26.4 1524 968 1 77 1524 968 1 77

H4036G*036AA 36 28.8 1524 968 1 78 1524 968 1 78

H4036G*039AA 39 31.2 1524 968 1 78 1524 968 1 78

H4052G*042AA

52

42 33.6 1524 968 1 79 1524 968 1 79

H4052G*048AA 48 38.4 1524 968 1 80 1524 968 1 80

H4052G*051AA 51 40.8 1524 968 1 81 1524 968 1 81

H4052G*054AA 54 43.2 1524 968 1 81 1524 968 1 81

H4052G*060AA 60 48.0 1524 968 1 82 1524 968 1 82

H4072G*054AA

72

54 43.2 1524 968 1 81 1524 968 1 81

H4072G*060AA 60 48.0 1524 968 1 82 1524 968 1 82

H4072G*066AA 66 52.8 1524 968 1 84 1524 968 1 84

H4072G*072AA 72 57.6 1524 968 1 85 1524 968 1 85

H4072G*075AA 75 60.0 1524 968 1 85 1524 968 1 85

H4072G*078AA 78 62.4 1524 968 1 86 1524 968 1 86

H4072G*081AA 81 64.8 1524 968 1 87 1524 968 1 87

H4072G*084AA 84 67.2 2032 1121 1 97 2032 1121 1 97

H4100G*084AA

100

84 67.2 2032 1121 1 97 2032 1121 1 97

H4100G*090AA 90 72.0 2032 1121 1 99 2032 1121 1 99

H4100G*096AA 96 76.8 2032 1121 1 100 2032 1121 1 100

H4123G*090AA

123

90 72.0 2032 1121 1 99 2565 1286 1 113

H4123G*096AA 96 76.8 2032 1121 1 100 2565 1286 1 110

H4123G*108AA 108 86.4 2565 1286 1 117 2565 1286 1 117

H4123G*120AA 120 96.0 2565 1286 1 119 2565 1286 1 119

H4123G*132AA 132 105.6 3099 1451 1 142 3099 1451 1 142

H4123G*138AA 138 110.4 3099 1451 1 144 3099 1451 1 144

H4145G*108AA

145

108 86.4 2565 1286 1 117 3099 1451 1 137

H4145G*120AA 120 96.0 2565 1286 1 119 3099 1451 1 140

H4145G*132AA 132 105.6 3099 1451 1 142 3099 1451 1 142

H4145G*138AA 138 110.4 3099 1451 1 144 3099 1451 1 144

H4145G*144AA 144 115.2 3099 1451 1 145 3099 1451 1 145

Table continued on next page.

NOTE: The * is replaced by L for Light Pollution, or M for Medium Pollution.NOTE: Grey (G) and (AA) Terminal codes used for illustrative purposes.

Page 41: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-41

HUBBELL®

Power Systems

®

H4 Physical Characteristics – Light & Medium Pollution Levels (continued)

Catalog # Um(kV)

Ur(kV)

Uc(kV)

(L)ight pollution (M)edium pollution

Creep-age

Distance (mm)

Height “H”

(mm)

Grading Ring

Dia. “D” (mm)

H4 Figure

Number

Weight (kg)

Creep-age

Distance (mm)

Height “H”

(mm)

Grading Ring

Dia. “D” (mm)

H4 Figure

Number

Weight (kg)

H4170G*132AA

170

132 105.6 3099 1451 n/a 1 142 3556 1945 640 3 184

H4170G*144AA 144 115.2 3099 1451 n/a 1 145 3556 1945 n/a 2 179

H4170G*162AA 162 129.6 3556 1945 n/a 2 182 3556 1945 n/a 2 182

H4170G*168AA 168 134.4 3556 1945 n/a 2 184 3556 1945 n/a 2 184

H4245G*180AA

245

180 144.0 4064 2098 640 3 204 5130 2428 990 3 237

H4245G*192AA 192 153.6 4064 2098 640 3 207 5130 2428 640 3 236

H4245G*198AA 198 158.4 4064 2098 640 3 209 5130 2428 640 3 237

H4245G*216AA 216 172.8 4597 2263 640 3 226 5130 2428 640 3 240

H4245G*228AA 228 182.4 5130 2428 640 3 243 5130 2428 640 3 243

H4300G*216AA

300

216 172.8 5130 2428 990 3 244 6198 2758 1530 3 294

H4300G*228AA 228 182.4 5130 2428 990 3 247 6198 2758 1530 3 296

H4300G*240AA 240 192.0 5130 2428 990 3 248 6198 2758 990 3 290

H4300G*258AA 258 206.4 5664 2593 990 3 273 6198 2758 990 3 294

H4300G*264AA 264 211.2 5664 2593 990 3 274 6198 2758 990 3 295

H4362G*258AA

362

258 206.4 6198 2758 1530 3 302 7695 3571 1530 4 346

H4362G*264AA 264 211.2 6198 2758 1530 3 304 7695 3571 1530 4 347

H4362G*276AA 276 220.8 6198 2758 1530 3 306 7695 3571 1530 4 349

H4362G*288AA 288 230.4 6198 2758 1530 3 309 7695 3571 1530 4 352

H4420G*312AA

420

312 249.6 7162 3406 1530 4 342 8763 3901 1530 4 399

H4420G*330AA 330 264.0 7162 3406 1530 4 346 8763 3901 1530 4 403

H4420G*336AA 336 268.8 7162 3406 1530 4 347 8763 3901 1530 4 404

H4420G*360AA 360 288.0 7695 3571 1530 4 366 8763 3901 1530 4 409

H4420G*372AA 372 297.6 8229 3736 1530 4 390 8763 3901 1530 4 411

H4420G*378AA 378 302.4 8229 3736 1530 4 392 8763 3901 1530 4 412

H4420G*390AA 390 312.0 8763 3901 1530 4 415 8763 3901 1530 4 415

H4420G*396AA 396 316.8 8763 3901 1530 4 416 8763 3901 1530 4 416

H4420G*420AA 420 336.0 9297 4066 990 4 433 9297 4066 990 4 433

NOTE: The * is replaced by L for Light Pollution, or M for Medium Pollution.NOTE: Grey (G) and (AA) Terminal codes used for illustrative purposes.

Page 42: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-42®

H4 Physical Characteristics – Heavy & Very Heavy Pollution Levels

Catalog # Um(kV)

Ur(kV)

Uc(kV)

(H)eavy pollution (V)ery heavy pollution

Creepage Distance

(mm)

Height “H”

(mm)

H4 Figure

Number

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

H4 Figure

Number

Weight (kg)

H4036G*024AA

36

24 19.2 1524 968 1 80 1524 968 1 80

H4036G*030AA 30 24.0 1524 968 1 81 1524 968 1 81

H4036G*033AA 33 26.4 1524 968 1 81 1524 968 1 81

H4036G*036AA 36 28.8 1524 968 1 82 1524 968 1 82

H4036G*039AA 39 31.2 1524 968 1 82 1524 968 1 82

H4052G*042AA

52

42 33.6 1524 968 1 83 2032 1121 1 89

H4052G*048AA 48 38.4 1524 968 1 84 2032 1121 1 94

H4052G*051AA 51 40.8 1524 968 1 85 2032 1121 1 95

H4052G*054AA 54 43.2 1524 968 1 86 2032 1121 1 96

H4052G*060AA 60 48.0 1524 968 1 87 2032 1121 1 97

H4072G*054AA

72

54 43.2 2032 1121 1 96 2565 1286 1 110

H4072G*060AA 60 48.0 2032 1121 1 97 2565 1286 1 111

H4072G*066AA 66 52.8 2032 1121 1 98 2565 1286 1 112

H4072G*072AA 72 57.6 2032 1121 1 99 2565 1286 1 113

H4072G*075AA 75 60.0 2032 1121 1 100 2565 1286 1 114

H4072G*078AA 78 62.4 2032 1121 1 100 2565 1286 1 115

H4072G*081AA 81 64.8 2032 1121 1 101 2565 1286 1 115

H4072G*084AA 84 67.2 2032 1121 1 101 2565 1286 1 116

H4100G*084AA

100

84 67.2 2565 1286 1 116 3556 1945 2 167

H4100G*090AA 90 72.0 2565 1286 1 117 3556 1945 2 168

H4100G*096AA 96 76.8 2565 1286 1 118 3556 1945 2 169

H4123G*090AA

123

90 72.0 3099 1451 1 138 4064 2098 2 178

H4123G*096AA 96 76.8 3099 1451 1 139 4064 2098 2 179

H4123G*108AA 108 86.4 3099 1451 1 142 4064 2098 2 182

H4123G*120AA 120 96.0 3099 1451 1 144 4064 2098 2 184

H4123G*132AA 132 105.6 3099 1451 1 146 4064 2098 2 186

H4123G*138AA 138 110.4 3099 1451 1 148 4064 2098 2 188

H4145G*108AA

145

108 86.4 4064 2098 2 182 4597 2263 2 196

H4145G*120AA 120 96.0 4064 2098 2 184 4597 2263 2 199

H4145G*132AA 132 105.6 4064 2098 2 186 4597 2263 2 201

H4145G*138AA 138 110.4 4064 2098 2 188 4597 2263 2 202

H4145G*144AA 144 115.2 4064 2098 2 189 4597 2263 2 203

Table continued on next page.

NOTE: The * is replaced by H for Heavy Pollution, or V for Very Heavy Pollution.NOTE: Grey (G) and (AA) Terminal codes used for illustrative purposes.

Page 43: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-43

HUBBELL®

Power Systems

®

H4 Physical Characteristics – Heavy & Very Heavy Pollution Levels (continued)

Catalog # Um(kV)

Ur(kV)

Uc(kV)

(H)eavy pollution (V)ery heavy pollution

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring

Dia. “D” (mm)

H4 Figure

Number

Weight (kg)

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring

Dia. “D” (mm)

H4 Figure

Number

Weight (kg)

H4170G*132AA

170

132 105.6 4597 2263 640 3 209 5664 2593 n/a 2 236

H4170G*144AA 144 115.2 4597 2263 640 3 211 5664 2593 n/a 2 238

H4170G*162AA 162 129.6 4597 2263 n/a 2 207 5664 2593 n/a 2 242

H4170G*168AA 168 134.4 4597 2263 n/a 2 208 5664 2593 n/a 2 243

H4245G*180AA

245

180 144.0 6198 2758 990 3 278 7695 3571 1530 4 330

H4245G*192AA 192 153.6 6198 2758 990 3 281 7695 3571 1530 4 333

H4245G*198AA 198 158.4 6198 2758 990 3 282 7695 3571 1530 4 334

H4245G*216AA 216 172.8 6198 2758 640 3 282 7695 3571 990 4 329

H4245G*228AA 228 182.4 6198 2758 640 3 284 7695 3571 990 4 331

H4300G*216AA

300

216 172.8 7695 3571 1530 4 337 9727 4548 2030 5 437

H4300G*228AA 228 182.4 7695 3571 1530 4 340 9727 4548 1530 5 419

H4300G*240AA 240 192.0 7695 3571 1530 4 342 9727 4548 1530 5 422

H4300G*258AA 258 206.4 7695 3571 990 4 337 9727 4548 1530 5 425

H4300G*264AA 264 211.2 7695 3571 990 4 338 9727 4548 1530 5 427

H4362G*258AA

362

258 206.4 9297 4066 2030 4 428 11328 5043 Note 1 5 Note 1

H4362G*264AA 264 211.2 9297 4066 2030 4 430 11328 5043 Note 1 5 Note 1

H4362G*276AA 276 220.8 9297 4066 1530 4 412 11328 5043 Note 1 5 Note 1

H4362G*288AA 288 230.4 9297 4066 1530 4 415 11328 5043 Note 1 5 Note 1

H4420G*312AA

420

312 249.6 10794 4878 2030 5 491 13359 6021 Note 1 6 Note 1

H4420G*330AA 330 264.0 10794 4878 2030 5 495 13359 6021 Note 1 6 Note 1

H4420G*336AA 336 268.8 10794 4878 1530 5 497 13359 6021 Note 1 6 Note 1

H4420G*360AA 360 288.0 10794 4878 1530 5 501 13359 6021 Note 1 6 Note 1

H4420G*372AA 372 297.6 10794 4878 1530 5 504 13359 6021 Note 1 6 Note 1

H4420G*378AA 378 302.4 10794 4878 1530 5 485 13359 6021 Note 1 6 Note 1

H4420G*390AA 390 312.0 10794 4878 1530 5 487 13359 6021 Note 1 6 Note 1

H4420G*396AA 396 316.8 10794 4878 1530 5 489 13359 6021 Note 1 6 Note 1

H4420G*420AA 420 336.0 10794 4878 1530 5 495 13359 6021 Note 1 6 Note 1

NOTE: The * is replaced by H for Heavy Pollution, or V for Very Heavy Pollution.NOTE: Grey (G) and (AA) Terminal codes used for illustrative purposes. NOTE 1: Special analysis required. Consult your Hubbell Power Systems representative.

Page 44: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-44®

Max System Voltage

Rated Voltage

Max Continuous Voltage L-G

H4 standard pollution ratings

Light Medium Heavy

Um Ur Uc Catalog Creep (mm)

20KA FOW* (kV)

Housing Code Catalog Creep

(mm)

20KA FOW* (kV)

Housing Code Catalog Creep

(mm)

20KA FOW* (kV)

Housing Code

36 27 21.6 H4036GL027 1524 89 1 H4036GM027 1524 89 1 H4036GH027 1524 89 136 30 24.0 H4036GL030 1524 98 1 H4036GM030 1524 98 1 H4036GH030 1524 98 136 33 26.4 H4036GL033 1524 106 1 H4036GM033 1524 106 1 H4036GH033 1524 106 136 36 28.8 H4036GL036 1524 115 1 H4036GM036 1524 115 1 H4036GH036 1524 115 136 39 31.2 H4036GL039 1524 123 1 H4036GM039 1524 123 1 H4036GH039 1524 123 152 42 33.6 H4052GL042 1524 129 1 H4052GM042 1524 129 1 H4052GH042 1524 129 152 48 38.4 H4052GL048 1524 146 1 H4052GM048 1524 146 1 H4052GH048 1524 146 152 51 40.8 H4052GL051 1524 154 1 H4052GM051 1524 154 1 H4052GH051 1524 154 152 54 43.2 H4052GL054 1524 162 1 H4052GM054 1524 162 1 H4052GH054 1524 162 152 60 48.0 H4052GL060 1524 179 1 H4052GM060 1524 179 1 H4052GH060 1524 179 172 54 43.2 H4072GL054 1524 159 1 H4072GM054 1524 159 1 H4072GH054 2032 162 272 60 48.0 H4072GL060 1524 176 1 H4072GM060 1524 176 1 H4072GH060 2032 179 272 66 52.8 H4072GL066 1524 193 1 H4072GM066 1524 193 1 H4072GH066 2032 196 272 72 57.6 H4072GL072 1524 210 1 H4072GM072 1524 210 1 H4072GH072 2032 213 272 75 60.0 H4072GL075 1524 218 1 H4072GM075 1524 218 1 H4072GH075 2032 221 272 78 62.4 H4072GL078 1524 227 1 H4072GM078 1524 227 1 H4072GH078 2032 230 272 81 64.8 H4072GL081 1524 235 1 H4072GM081 1524 235 1 H4072GH081 2032 238 272 84 67.2 H4072GL084 2032 246 2 H4072GM084 2032 246 2 H4072GH084 2032 246 2100 84 67.2 H4100GL084 2032 242 2 H4100GM084 2032 242 2 H4100GH084 2565 245 3100 90 72.0 H4100GL090 2032 259 2 H4100GM090 2032 259 2 H4100GH090 2565 262 3100 96 76.8 H4100GL096 2032 276 2 H4100GM096 2032 276 2 H4100GH096 2565 279 3123 90 72.0 H4123GL090 2032 255 2 H4123GM090 2565 259 3 H4123GH090 3099 262 4123 96 76.8 H4123GL096 2032 272 2 H4123GM096 2565 275 3 H4123GH096 3099 279 4123 108 86.4 H4123GL108 2565 309 3 H4123GM108 2565 309 3 H4123GH108 3099 312 4123 120 96.0 H4123GL120 2565 343 3 H4123GM120 2565 343 3 H4123GH120 3099 346 4123 132 105.6 H4123GL132 3099 379 4 H4123GM132 3099 379 4 H4123GH132 3099 379 4123 138 110.4 H4123GL138 3099 396 4 H4123GM138 3099 396 4 H4123GH138 3099 396 4145 108 86.4 H4145GL108 2565 306 3 H4145GM108 3099 309 4 H4145GH108 4064 322 22145 120 96.0 H4145GL120 2565 339 3 H4145GM120 3099 342 4 H4145GH120 4064 355 22145 132 105.6 H4145GL132 3099 376 4 H4145GM132 3099 376 4 H4145GH132 4064 389 22145 138 110.4 H4145GL138 3099 393 4 H4145GM138 3099 393 4 H4145GH138 4064 406 22145 144 115.2 H4145GL144 3099 410 4 H4145GM144 3099 410 4 H4145GH144 4064 423 22170 132 105.6 H4170GL132 3099 372 4 H4170GM132 3556 382 12 H4170GH132 4597 388 23170 144 115.2 H4170GL144 3099 406 4 H4170GM144 3556 416 12 H4170GH144 4597 422 23170 162 129.6 H4170GL162 3556 466 12 H4170GM162 3556 466 12 H4170GH162 4597 472 23170 168 134.4 H4170GL168 3556 483 12 H4170GM168 3556 483 12 H4170GH168 4597 489 23245 180 144.0 H4245GL180 4064 508 22 H4245GM180 5130 515 33 H4245GH180 6198 521 44245 192 153.6 H4245GL192 4064 542 22 H4245GM192 5130 548 33 H4245GH192 6198 555 44245 198 158.4 H4245GL198 4064 558 22 H4245GM198 5130 565 33 H4245GH198 6198 572 44245 216 172.8 H4245GL216 4597 612 23 H4245GM216 5130 615 33 H4245GH216 6198 622 44245 228 182.4 H4245GL228 5130 649 33 H4245GM228 5130 649 33 H4245GH228 6198 655 44300 216 172.8 H4300GL216 5130 607 33 H4300GM216 6198 613 44 H4300GH216 7695 630 333300 228 182.4 H4300GL228 5130 640 33 H4300GM228 6198 647 44 H4300GH228 7695 663 333300 240 192.0 H4300GL240 5130 674 33 H4300GM240 6198 681 44 H4300GH240 7695 697 333300 258 206.4 H4300GL258 5664 728 34 H4300GM258 6198 731 44 H4300GH258 7695 747 333300 264 211.2 H4300GL264 5664 744 34 H4300GM264 6198 748 44 H4300GH264 7695 764 333362 258 206.4 H4362GL258 6198 721 44 H4362GM258 7695 738 333 H4362GH258 9297 748 444362 264 211.2 H4362GL264 6198 738 44 H4362GM264 7695 754 333 H4362GH264 9297 764 444362 276 220.8 H4362GL276 6198 772 44 H4362GM276 7695 788 333 H4362GH276 9297 798 444362 288 230.4 H4362GL288 6198 805 44 H4362GM288 7695 822 333 H4362GH288 9297 832 444420 312 249.6 H4420GL312 7162 877 233 H4420GM312 8763 886 344 H4420GH312 10794 906 3334420 330 264.0 H4420GL330 7162 927 233 H4420GM330 8763 937 344 H4420GH330 10794 956 3334420 336 268.8 H4420GL336 7162 944 233 H4420GM336 8763 954 344 H4420GH336 10794 973 3334420 360 288.0 H4420GL360 7695 1014 333 H4420GM360 8763 1021 344 H4420GH360 10794 1040 3334420 372 297.6 H4420GL372 8229 1051 334 H4420GM372 8763 1054 344 H4420GH372 10794 1074 3334420 378 302.4 H4420GL378 8229 1068 334 H4420GM378 8763 1071 344 H4420GH378 10794 1091 3334420 390 312.0 H4420GL390 8763 1105 344 H4420GM390 8763 1105 344 H4420GH390 10794 1124 3334420 396 316.8 H4420GL396 8763 1122 344 H4420GM396 8763 1122 344 H4420GH396 10794 1141 3334

420 420 336.0 H4420GL420 9297 1192 444 H4420GM420 9297 1192 444 H4420GH420 10794 1208 3334

* Front-of-Wave 0.5µs Steep Current Impulse Residual Voltage at Specified Current

H4 Standard Pollution Levels

Table continued on next page.

Page 45: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-45

HUBBELL®

Power Systems

®

HousingCode

Creepmm

Heightmm

BIL W/SkV

SI W/SkV

PF 1 min wetkVrms

1 1524 825 280 246 143

2 2032 978 342 301 190

3 2565 1143 410 360 240

4 3099 1308 477 419 290

12 3556 1803 622 547 333

22 4064 1956 684 602 380

23 4597 2121 752 661 430

33 5130 2286 820 720 480

34 5664 2451 887 779 530

44 6198 2616 954 838 580

233 7162 3264 1162 1021 670

333 7695 3429 1230 1080 720

334 8229 3594 1297 1139 770

344 8763 3759 1364 1198 820

444 9297 3924 1431 1257 870

2333 9727 4407 1572 1381 910

3334 10794 4737 1707 1499 1010

H4 Insulation Withstand Values

BIL W/S Basic Insulation Level WithstandSI W/S Switching Impulse WithstandPF 1min wet Power Frequency Withstand, 1 minute wet

H4 standard pollution ratings

Very Heavy

Catalog Creep (mm)

20KA FOW* (kV)

Housing Code

H4036GV027 1524 89 1H4036GV030 1524 98 1H4036GV033 1524 106 1H4036GV036 1524 115 1H4036GV039 1524 123 1H4052GV042 2032 132 2H4052GV048 2032 149 2H4052GV051 2032 157 2H4052GV054 2032 166 2H4052GV060 2032 182 2H4072GV054 2565 166 3H4072GV060 2565 183 3H4072GV066 2565 199 3H4072GV072 2565 216 3H4072GV075 2565 225 3H4072GV078 2565 233 3H4072GV081 2565 241 3H4072GV084 2565 250 3H4100GV084 3556 259 12H4100GV090 3556 275 12H4100GV096 3556 292 12H4123GV090 4064 275 22H4123GV096 4064 292 22H4123GV108 4064 325 22H4123GV120 4064 359 22H4123GV132 4064 392 22H4123GV138 4064 409 22H4145GV108 4597 325 23H4145GV120 4597 359 23H4145GV132 4597 392 23H4145GV138 4597 409 23H4145GV144 4597 426 23H4170GV132 5664 395 34H4170GV144 5664 429 34H4170GV162 5664 479 34H4170GV168 5664 496 34H4245GV180 7695 537 333H4245GV192 7695 571 333H4245GV198 7695 588 333H4245GV216 7695 638 333H4245GV228 7695 672 333H4300GV216 9727 649 2333H4300GV228 9727 683 2333H4300GV240 9727 716 2333H4300GV258 9727 767 2333H4300GV264 9727 784 2333H4362GV258 Note 1 767 Note 1H4362GV264 Note 1 784 Note 1H4362GV276 Note 1 817 Note 1H4362GV288 Note 1 851 Note 1H4420GV312 Note 1 929 Note 1H4420GV330 Note 1 979 Note 1H4420GV336 Note 1 996 Note 1H4420GV360 Note 1 1063 Note 1H4420GV372 Note 1 1097 Note 1H4420GV378 Note 1 1114 Note 1H4420GV390 Note 1 1147 Note 1H4420GV396 Note 1 1164 Note 1

H4420GV420 Note 1 1231 Note 1

H4 Standard Pollution Levels (continued)

NOTE 1: Special Analysis Required. Consult your Hubbell Power Systems Representative.

Page 46: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-46®

H5Porcelain Housed

IEC Class 5 Arrester

H5 Physical Characteristics

H5 Protective Characteristics

Terminal Options

v A standard 4-hole suspension cap and standard ground ter-minals similar to the H3 and H4 arresters are available for the H5 arrester family.

v Due to the extremely high system voltages, various other terminal options exist to meet your connection requirements.

v Please consult your Ohio Brass representative to discuss these additional connection options.

Ur(kV)

Uc(kV)

Max steep current impulse

residual voltage at indicated current (1)

Max switching impulse residual

voltage at indicated current

Max lightning impulse residual voltage at indicated current

20kA 0.5kA 2kA 5kA 10kA 20kA 40kAkV kV kV kV kV kV kV

396 318 1017 727 762 826 859 919 994420 335 1075 768 805 873 908 971 1051444 353 1129 807 846 917 954 1020 1104588 470 1548 1074 1126 1221 1270 1358 1469612 485 1574 1092 1145 1242 1291 1381 1494

Catalog #Um(kV)

Ur(kV)

Uc(kV)

(M)edium pollution

Creepage Distance

(mm)

Height “H”

(mm)

Grading Ring Dia. “D” (mm)

H5 Figure

Number

Weight (kg)

H5550GM396AA 550 396 318.0 11010 4910 1530 1 940

H5550GM420AA 550 420 335.0 11010 4910 1530 1 946

H5550GM444AA 550 444 353.0 11010 4910 1530 1 952

H5800GM588AA 800 588 470.0 16700 7572 2286 2 1494

H5800GM612AA 800 612 485.0 16700 7572 2286 2 1500

(1) Max Residual voltage for a 20kA impulse current wave which produces a voltage wave cresting in 0.5µs. This can be used to coordinate where a front-of-wave sparkover was formerly used.

Page 47: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SCDECEMBER 2010

204-47

HUBBELL®

Power Systems

®

Page 48: DynaVar - SENER TRADE · tains stringent testing controls in accordance with IEC 60099-4 to ensure that the customer ... line-to-line voltage divided by 1.11. DynaVar arresters are

OHIO BRASS – AIKEN, SC DECEMBER 2010

HUBBELL®

Power Systems

204-48®

©Copyright 2010 Hubbell/Ohio Brass • 1850 Richland Avenue, East • Aiken, SC 29801

Web: http://www.hubbellpowersystems.comE-mail: [email protected]

MEXICOHUBBELL DE MEXICO, S.A. DE C.V.Av. Insurgentes Sur #1228, Piso 8Col. Tlacoquemacatl Del ValleMexico, D.F. 03200Phone: 52-55-9151-9999Fax: 52-55-9151-9988Website: hubbell.com.mx