UK/0126/0115 MI-006 Issue Date: Valid Until: Reference No: Xx November 2014 14 December 2021 TS0101/0011 Signatory: for G Stones Chief Executive 0135 National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United Kingdom Tel +44 (0)20 8943 7272 | Fax +44 (0)20 8943 7270 | Web www.gov.uk/nmo MID Annex B Rev. 2 01 April 2011 EC type-examination certificate UK/0126/0115 Revision 2 Issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments (Non-Prescribed Instruments) Regulations 2006 (SI 2006/1257) and the Measuring Instruments (Non- Prescribed Instruments) Regulations 2006 which implement, in the United Kingdom, Council Directive 2004/22/EC, this EC type-examination certificate has been issued to: NEMESIS srl Via Giulio Benassi 31 41122 Modena Italy In respect of a family of automatic checkweighing / catchweighing instruments designated the HSC350 and having the following characteristics: Maximum capacity Max ≤ 60,000 g Minimum capacity Min ≥ 42 g Scale interval e ≥ 1 g Number of scale intervals n ≤ 3,000 Maximum belt speed 60 m/min Accuracy class XIII(1) and Y(a) The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate. This revision replaces earlier versions of the certificate.

Upload: vodiep

Post on 01-Jan-2017

245 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: EC type-examination certificate UK/0126/0115 Revision 2

UK/0126/0115

MI-006

Issue Date: Valid Until: Reference No:

Xx November 2014 14 December 2021 TS0101/0011

Signatory: for

G Stones Chief Executive

0135

National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United Kingdom Tel +44 (0)20 8943 7272 | Fax +44 (0)20 8943 7270 | Web www.gov.uk/nmo

MID Annex B Rev. 2 01 April 2011

EC type-examination certificate UK/0126/0115 Revision 2

Issued by: The National Measurement Office Notified Body Number 0126

In accordance with the requirements of the Measuring Instruments (Non-Prescribed Instruments) Regulations 2006 (SI 2006/1257) and the Measuring Instruments (Non-Prescribed Instruments) Regulations 2006 which implement, in the United Kingdom, Council Directive 2004/22/EC, this EC type-examination certificate has been issued to:

NEMESIS srl Via Giulio Benassi 31 41122 Modena Italy

In respect of a family of automatic checkweighing / catchweighing instruments designated the HSC350 and having the following characteristics:

Maximum capacity Max ≤ 60,000 g Minimum capacity Min ≥ 42 g Scale interval e ≥ 1 g Number of scale intervals n ≤ 3,000 Maximum belt speed ≤ 60 m/min Accuracy class XIII(1) and Y(a) The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate.

This revision replaces earlier versions of the certificate.

Page 2: EC type-examination certificate UK/0126/0115 Revision 2

2/13

Descriptive Annex

1 INTRODUCTION

This family of automatic weighing instruments, designated the HSC350, comprises instruments operating as automatic checkweighers (Category X) and/or weigh or weigh-price labellers (Category Y).

The instruments comprise a cabinet, user interface, weighing device, mechanical handling facilities, reject device and/or labeller. The instruments are designed to weigh packs dynamically. Pricing, pack and labelling information are stored in files called PLUs selectable by the operator for the commodity or labels being processed. Labels are printed for the above transaction data and are applied to the packs automatically. 2 FUNCTIONAL DESCRIPTION

2.1 Mechanical

2.1.1 The instrument (Figure 1) is constructed in stainless steel. The framework is

a fabricated floor standing stainless steel frame on adjustable feet. On the frame are

mounted the modular conveyor and the conveyors type, number, size and shape are

not restricted. The conveyor can be equipped with one of a number of reject devices,

including a flipper, drop flap, ram or air blast (Category X), and/or thermal label printers

(Category Y). The instrument is designed to be permanently installed. 2.1.2 The control cabinet is located behind of the instrument, houses the electrical hardware. A PL30 weighing indicator console, mounted above the control cabinet contains the keyboard and displays. Photocells mounted on frame are used for pack detection. The photocells may also be direct reading, reflex or laser type. 2.1.3 Weigh platform unit 2.1.3.1 The weighing device comprises a strain gauge load cell located below the centre of the weigh conveyor. The load cell type may be as follows: HBM SP4M C3MR, HBM PW6D C3MR, HBM PW2D C3MR or HBM PW16A C3MR, capacity according to section 3.1 of this certificate.

Any compatible load cell may be used providing the following conditions are met:

There is a respective OIML Certificate of Conformity (R60) or a parts/test certificate (EN45501) issued for the load cell by a Notified Body responsible for type examination under Directive 2009/23/EEC.

The certificate contains the load cell types and the necessary load cell data required for the manufacturer’s declaration of compatibility of modules (WELMEC 2, Issue 6, 2014, No 10), and any particular installation requirements. A load cell marked NH is allowed only if humidity testing to EN45501 has been conducted on this load cell.

It is not a load cell with digital output

The characteristics of the replacement load cell such as nlc, Y, Z are the same or better than the load cell tested dynamically (HBM SP4M C3MR, capacity 7 kg)

Page 3: EC type-examination certificate UK/0126/0115 Revision 2

3/13

The design of the load cells and the material are the same

No oil damper is used 2.1.3.2 Packs are weighed as they pass over the weigh head conveyor which runs continuously at the speed of the in-feed and out-feed conveyors. 2.2 Electrical 2.2.1 The s t a i n l e s s s t e e l control cabinet is accessible through a door on the rear; and comprises the circuit breakers, power supplies, motor drive cards and appropriate input/output modules for external electrical interfaces such as the out- feed mechanisms, label applicator and external peripherals. 2.2.3 The PL30 indicator (Figure 2) is mounted on top of the cabinet. The PL30 includes an LED display, an LCD display, functions and alphanumerical keypads, ON/OFF switches for the conveyors and an integrated printer, as well as the load cell module, filters, and related I/O section. The display is segregated in distinct areas, and allows viewing of the weighing parameters and results as well as access to the various functions. 2.2.4 The weighing indicator PL30 is fitted with a load cell module type PL555A, which is directly connected to the load cell with a 6-wire cable and reads and digitises the analogue load cell signal with a 16bit ADC type TI. The CPU reads this digital value and performs digital filtering and processing of the signal to produce the individual pack weight. 2.3 Devices

2.3.1 The instrument has the following devices:

Automatic zero setting device active during automatic operation (active if no zero has occurred after 22 min)

Zero tracking Semi-automatic zero-setting (≤ 4% max) Initial zero-setting (≤ 20% max) Pre-set tare device (subtractive) Static calibration, not accessible to the user Belt speed setting, accessible to the user (access password protected level 1) Printing of batch results (Category X) Screen check at power-up High resolution mode (0.1e) for testing purposes Parameter to select operation in Category X or Y at initial verification

(protected parameter) Parameter to select operation in Category X or Y by the user in normal

operation if the above parameter is set to X and Y

Page 4: EC type-examination certificate UK/0126/0115 Revision 2

4/13

3 TECHNICAL DATA

3.1 The HSC350 family of instruments has the following technical characteristics.

Designation HSC350/ 03

HSC350/ 06

HSC350/ 15

HSC350/ 30

HSC350/ 60

Maximum capacity (Max) (≤): 3,000 g 6,000 g 15,000 g 30,000 g 60,000 g

Minimum capacity (Min) (≥): 42 g 84 g 210 g 420 g 840 g

Scale interval (e =) (≥): 1 g 2 g 5 g 10 g 20 g

Maximum number of scale intervals (n):

3000

Load cell Emax: 7 kg 10 kg 30 kg 50 kg 100 kg

Tare (T): -450 e

Belt speed: ≤ 60 m/min

Climatic environment 0°C to +40 °C

Non-condensing (closed)

Electromagnetic environments E1 and E2

Power supply 230 Va.c. 50 Hz

Accuracy class XIII(1) and Y(a)

3.2 Documentation and drawings

Description Drawing / Document number Rev.

Operating Manual HSC350 Manual 01/08/2011 1.7 EN

HSC350 version HSC350 50EN2 Binary code 0811

Load cell HBM SP4 , PW2 and PW6 Rev 1

PL30 weighing indicator Test Certificate UCM05/003 19/10/2010

PL30 weighing indicator CIBE Lab Test report 24/12/2009

PL30 weighing indicator MASINI Lab Test report 0267/2010

Board datasheet COM board COM board PL501.5 14/12/2007

Board datasheet mother board mother board PL30C 5/3/2010

Board datasheet ADC board A/D board PL555A 5/3/2010

Board datasheet I/O board I/O board PL511A 10/12/2003

Board datasheet CPU CPU board PL501.3 19/07/2005

Board keyboard/display HMI mod.PL30DS3 27/10/2008

3.3 Software

3.3.1 The software is designated WS30.version 07.XX.XX where 07 reflects the legally relevant part of the software and XX are numbers reflecting minor changes to the non-legally relevant part of the software. The software version is shown in the start-up window when the instrument is in warm-up mode and can also be displayed at any time upon command. 3.3.2 Security

Legally relevant parameters are protected by a calibration and set-up switch located on the CPU board, installed inside the sealed cabinet. Legally relevant parameters are stored in non volatile memory and the legally relevant software is stored in the EPROM.

Page 5: EC type-examination certificate UK/0126/0115 Revision 2

5/13

4 PERIPHERAL DEVICES AND INTERFACES

4.1 Interfaces

The instrument may have any of the following interfaces:

RS232 serial ports

4.2 Peripheral devices

The instrument may be connected to any peripheral device that has been issued with a test certificate or parts certificate by a Notified Body responsible for Annex B (MI-006) under Directive 2004/22/EC in any Member State and bears the CE marking of conformity to the relevant directives; or

A peripheral device without a test certificate may be connected under the following conditions:

it bears the CE marking for conformity to the EMC Directive;

it is not capable of transmitting any data or instruction into the weighing instrument, other than to release a printout, checking for correct data transmission or validation;

it prints weighing results and other data as received from the weighing instrument without any modification or further processing; and

it complies with the applicable requirements of Paragraph 8.1 of Annex I.

5 APPROVAL CONDITIONS

The certificate is issued subject to the following conditions:

5.1 Legends and inscriptions

5.1.1 The instrument bears the following legends (Figure 3):

‘CE’ marking Supplementary metrology marking Notified Body identification number Accuracy class Serial number Manufacturers mark or name Certificate number Max Min e = T = - Temperature-range Maximum speed / pack rate

Page 6: EC type-examination certificate UK/0126/0115 Revision 2

6/13

6 LOCATION OF SEALS AND VERIFICATION MARKS

6.1 The ‘CE’ marking, supplementary metrology marking and certificate number are located on the side of the control cabinet. The CE mark shall be impossible to remove without damaging it. The data plate shall be impossible to remove without it being destroyed.

The markings and inscriptions shall fulfil the requirements of Paragraph 9 of Annex I of the Directive 2004/22/EC.

6.2 Components that may not be dismantled or adjusted by the user (load cell, cal/setup jumper, rating plate) will be secured by either a wire and seal or tamper evident label and securing mark.

The securing mark may be either:

a mark of the manufacturer and/or manufacturer’s representative, or

an official mark of a verification officer.

7 ALTERNATIVES

7.1 Having the instrument fitted with a transport system designated “R chain” and consisting of two, ¼ inch, plastic chains instead of rollers to support and drive the conveyor belts. The chains slide on two plastic bars held in position by metallic rods fixed to the instrument. Gaps in the plastic bars ensure the central part of the weigh conveyor is only connected to the live part of the instrument supported by the load cell (Figure 4). 7.2 Having a modified construction: the PL30 indicator is enclosed in a cabinet (Figure 5).

7.3 Having the instrument operating as multi-lanes: each lane is operated by a separate PL30, with a common, larger cabinet (Figure 6).

7.4 Having the LED display, LCD display, functions and alphanumerical keypads of the PL30 indicator replaced by a touch screen (Figure 7).

The indicator includes a long term data storage device and may be fitted with an additional integrated printer. The batch information is stored automatically and the records can be used for legal purposes.

The software is designated WS30, the version number can be displayed by pressing the “apple” icon and shall be 7.01.XX, with XX reflecting non-legally relevant changes.

The instrument may have any of the following interfaces:

RS232 USB Ethernet

7.5 Having the instrument fitted with a transport system designated “Q Series drag chain”, similar in construction to the “R chain” described in section 7.1 but with a modular plastic belt (Figure 8). 7.6 Having the instrument fitted with a 10.2” touch screen HMI (Figure 9).

Page 7: EC type-examination certificate UK/0126/0115 Revision 2

7/13

7.7. Having the instrument fitted with a modified AD board (according to drawing A/D board PL555E, rev 1 dated 12/12/2013). The specifications and load cells are as follows:

Designation HSC350/02 HSC350/04 HSC350/08 HSC350/20 HSC350/40

Max (≤) 2,000 g 4,000 g 8,000 g 20,000 g 40,000 g

Min (≥) 15 g 30 g 60 g 150 g 300 g

e = (≥) 0.5 g 1 g 2 g 5 g 10 g

nmax 4,000

Load cell type PW6 C3MR PW6 D3MR SP4M C3MR

PW6 C3MR PW6 D3MR SP4M C3MR

PW6 C3MR PW6 D3MR SP4M C3MR

PW16A C3MR

PW16A C3MR

Load cell Emax: 5 kg 10 kg 20 kg 50 kg 100 kg

Tare (T): Min – 80e ≤ 20% Gross 80e – 500e ≤ 65% Gross 500e – Max ≤ 90% Gross

Belt speed: Min – 500e ≤ 30 m/min 500e – Max ≤ 40 m/min

Min – 80e ≤ 30 m/min 80e – Max ≤ 40 m/min

Climatic environment

0°C to +40 °C 5°C to +40 °C

Non-condensing (closed)

Electromagnetic environments E1 and E2

Power supply 230 Va.c. 50 Hz

Accuracy class XIII(1) and Y(a)

Any compatible load cell may be used providing the following conditions are met:

There is a respective OIML Certificate of Conformity (R60) or a parts/test certificate (EN45501) issued for the load cell by a Notified Body responsible for type examination under Directive 2009/23/EEC.

The certificate contains the load cell types and the necessary load cell data required for the manufacturer’s declaration of compatibility of modules (WELMEC 2, Issue 6, 2014, No 10), and any particular installation requirements. A load cell marked NH is allowed only if humidity testing to EN45501 has been conducted on this load cell.

It is not a load cell with digital output

The characteristics of the replacement load cell such as nlc, Y, Z are the same or better than the load cell tested dynamically (HBM PW6 C3MR, capacity 5 kg)

The design of the load cells and the material are the same

No oil damper is used

The automatic zero setting device shall be active during automatic operation if no zero has occurred after 22 min. The instruments may have any of the following interfaces:

RS232 USB Ethernet

Page 8: EC type-examination certificate UK/0126/0115 Revision 2

8/13

8 ILLUSTRATIONS

Figure 1 HSC350 Checkweigher (3 conveyor belts)

Figure 2 PL30 weighing indicator Figure 3 Rating plate Figure 4 “R chain” transport system Figure 5 Modified construction Figure 6 Multi-lane configuration Figure 7 PL30 indicator with touch screen display Figure 8 “Q Series drag chain” transport system Figure 9 10.2” touch screen HMI 9 CERTIFICATE HISTORY

ISSUE NO. DATE DESCRIPTION

UK/0126/0115 15 December 2011 Type examination certificate first issued.

UK/0126/0115 rev 1 27 July 2012 HSC350/60 model added to table 3.1.

Max changed to ≤ 60000 g on front page.

Sections 7.4 and 7.5 added.

UK/0126/0115 rev 2 14 November 2014 ≥ and ≤ added to table 3.1 for Max, Min and e =.

Sections 7.6 and 7.7 added.

Page 9: EC type-examination certificate UK/0126/0115 Revision 2

9/13

Figure 1 HSC350 Checkweigher (3 conveyor belts)

Figure 2 PL30 weighing indicator

Page 10: EC type-examination certificate UK/0126/0115 Revision 2

10/13

Figure 3 Rating plates

Figure 4 "R chain" transport system

Page 11: EC type-examination certificate UK/0126/0115 Revision 2

11/13

Figure 5 Modified construction

Figure 6 Multi-lane configuration

Page 12: EC type-examination certificate UK/0126/0115 Revision 2

12/13

Figure 7 PL30 indicator with touch screen display

Figure 8 “Q Series drag chain” transport system

Page 13: EC type-examination certificate UK/0126/0115 Revision 2

13/13

Figure 9 10.2” touch screen HMI © Crown Copyright 2014 NATIONAL MEASUREMENT OFFICE Department for Business, Innovation & Skills