ecb...• connect the wires at outputs 3 and 4 to the dc input of the inverter 1 and the wires at...
TRANSCRIPT
ECB Easy Connect ion Box
Installations- und bedienungsanleitung DE
Manual de instalación y uso ES
Manuel d’installation et d’utilisation FR
Installation and operating manual GB
Manuale di installazione e uso IT
3ECB - Ref.: IOMSUNXXXX08-GB 03
EN
GL
ISH
1. REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1. CONVENTIONS USED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2. ABBREVIATIONS AND ACRONYMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3. SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.4. QUALIFIED PERSONNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1. GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2. ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.3. DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.1. MECHANICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2. ELECTRICAL INSTALLATION (ECB3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.3. ELECTRICAL INSTALLATION (ECB6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4. MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1. REGULAR INSPECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.2. SPD REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5. TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
CONTENTS
4 ECB - Ref.: IOMSUNXXXX08-GB 03
The packaging guarantees stability for the equipment during all transport and handling procedures. Carry the packaged unit as
close as possible to the installation site.
When handling the unit on inclined surfaces (even where the incline is minimal), use equipment fitted with suitable
locking devices in order to prevent serious accidents.
1.1. CONVENTIONS USED
The following conventions are used in this guide.
CAUTION: RISK OF ELECTRIC SHOCK
Before beginning any installation procedures make sure you are wearing suitable safety equipment.
IMPORTANT!
These notes contain information you need to be aware of but are not as serious as a caution or warning.
1.2. ABBREVIATIONS AND ACRONYMS
AC: Alternating current
AC (Im): Maximum current AC
AC (Un): Rated voltage AC
DC: Direct current
DC (Im): Maximum current DC
DC (Un): Rated voltage DC
H: Height
W: Width
D: Depth
Ui: Rated insulation voltage
ECB3: Easy Connection Box 3 kW
ECB6: Easy Connection Box 6 kW
1. REQUIREMENTS
5
EN
GL
ISH
ECB - Ref.: IOMSUNXXXX08-GB 03
1. REQUIREMENTS
1.3. SAFETY INSTRUCTIONS
• Read this instruction manual before commissioning the equipment.
• The photovoltaic panels constantly supply a very high DC power level and the DC switch only cuts off connection with the inverter.
Never touch live parts powered by the photovoltaic panels, as doing so could cause serious injury due to electric shock.
• The device must only be accessed by authorised personnel.
• Unauthorised opening of the device or incorrect maintenance work may cause serious personal injury, fatal accidents or serious
material damage.
• All repair procedures must only be carried out by qualified personnel.
• All repair procedures must only be carried out using original spare parts.
• Original spare parts can be purchased from SOCOMEC customer service.
• Check the protective devices regularly.
• Only use fuses of the correct size.
• For plug-in photovoltaic connectors, the same brand of male and female connectors must be used.
• Making any changes to the ECB panel without obtaining prior consent from SOCOMEC is strictly prohibited.
Clean the ECB with a damp cloth and water or neutral soap.
1.4. QUALIFIED PERSONNEL
Personnel must be familiar with installation, assembly, commissioning and device operation procedures, and must be aware of
potential hazards.
Personnel must possess the required qualifications to carry out commissioning and maintenance procedures.
More specifically these qualifications include:
• Mechanical installation of the device: professional installer with basic electrical skills
• Electrical installation of the device: professional electricians
• Commissioning of the device: professional electricians.
6 ECB - Ref.: IOMSUNXXXX08-GB 03
2.1-1 Operating principle of a photovoltaic system
2.1-2
2. INTRODUCTION
2.1. GENERAL DESCRIPTION
The ECB (Easy Connection Box) can be used to switch off and isolate the power supply (AC or DC) in the event of non-routine
maintenance or photovoltaic inverter replacement.
11
Solar panels
ECB 3 kW ECB 6 kW
Inverter Electricity network
7ECB - Ref.: IOMSUNXXXX08-GB 03
EN
GL
ISH
2.2. ELECTRICAL DIAGRAM
There are two versions of ECB: ECB 3 kW to connect to only one 3 kW Inverter (fig 2.2-1) and ECB 6 kW to connect to two 3 kW
Inverters (fig 2.2-2). The ECB has one or two (depending on the model) DC switches to cut off the photovoltaic panels of the inverter,
which can also be handled while charged. Type 2 surge protection devices (SPD) are fitted downstream of the switch, in a classic
Y configuration.
The AC section has one or two (depending on the model) magnetothermal circuit breakers to which a 30 mA type A differential switch
(optional) can also be connected. The AC section is protected by type 2 SPD fitted with protection fuses.
The ECB connection panel is categorised as Class 2, therefore the earth wire is connected directly to the dischargers.
SPD intervention can be ‘monitored’ by the photovoltaic inverter, by connecting the relevant cable (supplied) to the inverter interface
circuit board (please refer to the inverter instruction manual).
When the ECB6 version is installed SPD intervention must only be ‘monitored’ only on one inverter.
2.2-1
FROM THE PANELSwith DC connectors
DC INPUT BREAKER25 A 600 V
SPD DCSURGYSG51800V
TO THE INVERTER GND
FROM THE INVERTER
AC OUTPUT BREAKER16 A 500 V CURVE C
DIFF. 30 mA TYPE A
FUSE16 A gG
SPD ACSURGYSD40
TO THE MAINSwith AC connector
SURGYS AC/DC
N.O.APD AC
N.O.APD DC
PROTECTIONS
N.B.: the differential linked to Q3 is optional.
N.B.: the differentials linked to Q3 and Q4 are optional.
2. INTRODUCTION
2.2-2
From the panelswith DC connectors
Q1
+ -
+ -
F N F N
Q2 Q3 Q4DC INPUTBREAKER25 A 600 V
SPD1 DCSURGYSG51800 V
SPD1 DCSURGYSG51800 V
SPD2 DCSURGYSG51800 V
SPD ACSURGYSD40
TO THE MAINSwith AC connector
GND
DIFF. 30 mA TYPE A DIFF. 30 mA TYPE A
N.O.SPD1 DC
N.O.SPD2 DC
N.O.SPD AC
DC INPUTBREAKER25 A 600 V
AC OUTPUT BREAKER16 A 500 V CURVE C
AC OUTPUT BREAKER16 A 500 V CURVE C
From the panelswith DC connectors
From the inverter 1
TO THE INVERTER 1 TO THE INVERTER 2
From the inverter 2
+ -
+ -
Q1 Q3
8 ECB - Ref.: IOMSUNXXXX08-GB 03
2.3-1
2.3. DIMENSIONS
205350
1000
SPD
SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY
SPD
SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY
Front view 1
1 Dimensions in mm
Side view 1
View from below ECB6
View from below ECB3View from above
2. INTRODUCTION
9ECB - Ref.: IOMSUNXXXX08-GB 03
EN
GL
ISH
3. INSTALLATION
3.1. MECHANICAL INSTALLATION
The equipment is designed for both indoor and outdoor operation.
WARNING!
Assemble it vertically or at a maximum angle of 45°. Be careful, as in this case a drop in performance (derating) may
occur due to the deterioration of heat dispersal.
The support points used to secure the panel must be sufficiently flat.
3.1-1: Remove the ECB from the packaging.
3.1-2: Remove the board fixing screws from the bracket.
3.1-3: Fasten the bracket supplied directly to the wall using two wall plugs, and to the inverter bracket using two nuts. To fix the ECB
on the wall in lateral position use the four holes.
3.1-1
Quick start guide
INSTALLATION AND
OPERATING MANUAL
3.1-2
3.1-3
10 ECB - Ref.: IOMSUNXXXX08-GB 0310 ECB - Ref.: IOMSUNXXXX08-GB 03
Strip the Red and Black wires coming from panels and attach them to the relevant DC connectors. Connect the AC plug to the
power supply cable coming from mains (connectors and plug supplied).
3.1-4: Fix the ECB to the bracket using the four screws supplied (two on each side).
3.1-5: Remove the two anchoring screws from the mobile part of the bracket.
3.1-6: Rotate the ECB to connect the wires to the inverter.
3.1-4 3.1-5
3. INSTALLATION
3.1-6
11
EN
GL
ISH
ECB - Ref.: IOMSUNXXXX08-GB 03
3. INSTALLATION
3.2-1
SPD
SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY
3.2. ELECTRICAL INSTALLATION (ECB3)
CAUTION: RISK OF ELECTRIC SHOCK
Before beginning any installation procedures, make sure you are wearing suitable safety equipment.
• Make sure the DC cut-off switch and the AC magnetothermal circuit breaker are set to OFF.
• Check that there is no AC mains power in the cable at the panel power socket installation point.
• Connect the AC mains power cable to the single-phase plug (Phase + Neutral + earth) supplied with the inverter and then plug it into input 8.
• Connect the wires coming from the photovoltaic system to inputs 1 and 2 (the DC connectors are supplied with the inverter).
• Connect the wires at output 3 and 4 to the DC input of the inverter, taking care to run them behind the ECB.
• Connect the wire at output 7 to the AC input of the inverter, taking care to run it behind the ECB.
• Connect the SPD monitoring contacts at output 6 to the inverter (please refer to the inverter manual for connection details).
• Connect the earth wire at output 5 of the ECB, to the earth bar in the inverter.
• After making all the electrical connections, rotate the board till it is vertical and secure the mobile part using the two screws.
• Position and secure the two red protective elements.
1 3 5
2 4 6 7 8
12 ECB - Ref.: IOMSUNXXXX08-GB 0312 ECB - Ref.: IOMSUNXXXX08-GB 03
3. INSTALLATION
3.2-2
3.2-4
click
3.2-3
2
3 4 7 5 6
18
13ECB - Ref.: IOMSUNXXXX08-GB 03
EN
GL
ISH
3.3. ELECTRICAL INSTALLATION (ECB6)
CAUTION: RISK OF ELECTRIC SHOCK
Before beginning any installation procedures, make sure you are wearing suitable safety equipment.
• Make sure the DC cut-off switch and the AC magnetothermal circuit breaker are set to OFF.
• Check that there is no AC mains power in the cable at the panel power socket installation point.
• Connect the AC mains power cable to the single-phase plug (Phase + Neutral + earth) supplied with the inverter and then plug it
into input 8.
• Connect the wires coming from the photovoltaic system to inputs 1 and 2 for string 1 and to input 9 and 10 for string 2 (the DC
connectors are supplied with the inverter).
• Connect the wires at outputs 3 and 4 to the DC input of the inverter 1 and the wires at output 11 and 12 to the DC input of the
inverter 2, taking care to run them behind the ECB.
• Connect the wire at output 7 to the AC input of the inverter 1 and the wire at output 13 to the AC input of the inverter 2, taking
care to run it behind the ECB.
• Connect the SPD monitoring contacts at output 6 to the inverter 1 or 2 (please refer to the inverter manual for connection details).
• Connect the earth wire at output 5 of the ECB, to the earth bar in the inverter.
• After making all the electrical connections, rotate the board till it is vertical and secure the mobile part using the two screws.
• Position and secure the two red protective elements.
3. INSTALLATION
3.3-1
SPD
SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY
2 10 4
1 9 3 11 5 13
12 6 7 8
14 ECB - Ref.: IOMSUNXXXX08-GB 0314 ECB - Ref.: IOMSUNXXXX08-GB 03
3.3-2 3.3-3
3
1
3.3-5
click
3.3-4
3. INSTALLATION
2
10
1
98
3 4 7 5 6
11 12 13
15
EN
GL
ISH
ECB - Ref.: IOMSUNXXXX08-GB 03
4. MAINTENANCE
CAUTION: RISK OF ELECTRIC SHOCK
Before beginning any installation procedures, make sure you are wearing suitable safety equipment.
4.1. REGULAR INSPECTIONS
The following should be checked on a regular basis (at least once a year):
• Condition of wires.
• Condition of the panel.
• Condition of connections.
• Condition of fuses.
• Condition of switches (test differential switch intervention, if fitted).
• Condition of Surgys overvoltage SPD (end of service life indicators: green = ok; red = faulty)
4.2. SPD REPLACEMENT
If the dischargers need to be replaced, proceed as follows:
• Make sure that the ECB is completely disconnected (switches set to OFF and all AC/DC wires disconnected)
• Remove the clear plastic cover protecting the SPD
• Remove and replace the damaged SPD
• Replace any blown fuses (AC section only)
• Reposition the clear plastic cover
• Connect all AC/DC wires
• Set the DC switch to ON
• Set the AC magnetothermal circuit breaker to ON
Reference code for the Surgys SPD G51 PV 800 V REM 49822511
Reference code for the Surgys SPD D40 MD 320 V REM 49821426
Reference code for fuses 10 x 38 16 A gG 60120016
16 ECB - Ref.: IOMSUNXXXX08-GB 0316 ECB - Ref.: IOMSUNXXXX08-GB 03
5. TECHNICAL SPECIFICATIONS
Models ECB3 ECB6
Rated voltage DC (Un) 600 V 600 V
Maximum current DC (lm) 13 A 26 A 13+13 A
Rated voltage AC (Un) 230 V 230 V
Maximum current AC (lm) 16 A 32 A 16+16 A
Rated insulation voltage (Ui) 800 V 800 V
Earthing system Class II Class II
Compliance with standard EN 61439-2 EN 61439-2
Operating temperature -20÷60 °C -20÷60 °C
Protection rating IP65 IP65
Dimensions (unit) (W x D x H) 350 x 560 x 230 mm 350 x 560 x 230 mm
Weight (net) 13,5 kg 13,5 Kg 14,5 kg
Rated impulse voltage Class II Class II
Dimensions ECB with Inverter (W x D x H) 350 x 205 x 1000 mm 350 x 205 x 1000 mm