AgendaObjective: Seeking TF approval of draft workpaper
• Measure Description
• Work Paper Methodology
• Results
• Issues and Concerns
• Questions or Comments
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 3
Measure DescriptionMeasure Case
Variable speed pool pump• Integrated pump, motor, and
controller unit• Can be programmed for different
speeds at different times• High efficiency motor
Base CaseSingle speed pool pump• Typically operates 24/7• Size ranges from 0.5 to 3 HP• Fixed speed of 3,450 rpm
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 4
Measure DescriptionUnits: Per horsepower
Measure Application and Delivery Type
1. Direct Install (ER or ROB depending on pump condition)
2. Downstream Prescriptive Rebate (ROB)
Eligibility• Climate zones: All• Building types: Hotels, Motels, Assembly
Target Market• Lodging facilities with standard (non-Olympic) size pools• Assemblies: Fitness centers, clubs, public pools, etc.
Market Potential
About 8,700 commercial pools in SCE territory
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 5
Measure DescriptionMeasure Costs
• Baseline cost (material + labor): $700• Measure cost: $1,650• Incremental cost: $950
EUL
10 years (DEER EUL ID: OutD-PoolPump)
Net-to-Gross
0.85 (DEER EUL ID: ET-Default)
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 6
Work Paper MethodologyBaseline Data Collection
Building type Sites surveyed
Parameters Market Assessment
Lodging 50 • Operating schedules• Equipment specs• Pool system
characteristics• Voltage, current,
power factor
Good candidates. Mostly single speed pumps ≤ 3 HP, operating 24/7.Assemblies 31
Schools 46 Pools too large
Baseline Methodology – Early Retirement
𝑃𝑏𝑎𝑠𝑒 [𝑘𝑊 ]=𝑉 𝑅𝑀𝑆 [𝑉 ]∗ 𝐼𝑅𝑀𝑆 [𝑎𝑚𝑝𝑠 ]∗𝑝𝑓 ∗ 1𝑘𝑊1,000𝑊ER:
𝐸𝑏𝑎𝑠𝑒 [ h𝑘𝑊 ]=𝑃𝑏𝑎𝑠𝑒 [𝑘𝑊 ]∗𝑃𝑢𝑚𝑝𝐻𝑜𝑢𝑟𝑠[ h𝑜𝑢𝑟𝑠𝑑𝑎𝑦 ]∗ h𝐴𝑛𝑛𝑢𝑎𝑙𝑆𝑐 𝑒𝑑𝑢𝑙𝑒 [ 𝑑𝑎𝑦𝑠𝑦𝑒𝑎𝑟 ]
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 7
Work Paper MethodologyBaseline Methodology – Replace on Burnout
𝑃𝑏𝑎𝑠𝑒 [𝑘𝑊 ]=𝑃𝑏𝑎𝑠𝑒 [𝑘𝑊 ]∗ 𝐴𝑣𝑔𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑦 ,𝑛𝑜𝑛𝑐𝑜𝑑𝑒𝑐𝑜𝑚𝑝𝑙𝑖𝑎𝑛𝑡𝐴𝑣𝑔𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑦 ,𝑐𝑜𝑑𝑒𝑐𝑜𝑚𝑝𝑙𝑖𝑎𝑛𝑡
ROB:
HP Non Qualifying
Title 20 Qualifying
Adjustment Factor
0.5 62% 77% 81%0.75 63% 76% 83%
1 66% 76% 87%1.5 65% 76% 86%2 67% 79% 85%
2.5 70% 77% 91%3 70% 79% 89%
Codes and Standards Enhancement study
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 8
Work Paper MethodologyMeasure Data Collection
CEC System Curves
• System Curve C used to represent pool plumbing system
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 9
Work Paper MethodologyMeasure Data Collection
CEC Pool Pump Test Database
• Variable speed pump power consumption
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 10
Work Paper MethodologyMeasure Methodology
Code Requirements (Public Pools)
• Title 24: Must be capable of 6-hour turnover
• Title 22: Cannot lower flow below 65% of Title 24 levels
• Title 20: Two speed required for Res pool pumps ≥ 1 hp
• Proposed: SS ≥ 70% efficiency, VS ≥ 80% @ full, ≥ 70% at half
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 11
Work Paper MethodologyMeasure Methodology
𝑄𝑐𝑙𝑜𝑠𝑒𝑑 [𝑔𝑝𝑚 ]= 𝑃𝑜𝑜𝑙𝑉𝑜𝑙𝑢𝑚𝑒 [𝑔𝑎𝑙]
24h𝑜𝑢𝑟𝑠
𝑡𝑢𝑟𝑛𝑜𝑣𝑒𝑟∗60 𝑚𝑖𝑛
h𝑜𝑢𝑟
𝐸𝑚𝑒𝑎𝑠𝑢𝑟𝑒 [ h𝑘𝑊 ]=(𝑃𝑚𝑒𝑎𝑠𝑢𝑟𝑒 ,𝑜𝑝𝑒𝑛 [𝑘𝑊 ]∗𝐴𝑑𝑗𝑢𝑠𝑡𝑒𝑑𝑂𝑝𝑒𝑛𝐻𝑜𝑢𝑟𝑠 [ h𝑜𝑢𝑟𝑠𝑑𝑎𝑦 ]+¿𝑃𝑚𝑒𝑎𝑠𝑢𝑟𝑒 ,𝑐𝑙𝑜𝑠𝑒𝑑 [𝑘𝑊 ]∗𝐶𝑙𝑜𝑠𝑒𝑑𝐻𝑜𝑢𝑟𝑠 [ h𝑜𝑢𝑟𝑠
𝑑𝑎𝑦 ])∗ h𝐴𝑛𝑛𝑢𝑎𝑙𝑆𝑐 𝑒𝑑𝑢𝑙𝑒 [ 𝑑𝑎𝑦𝑠𝑦𝑒𝑎𝑟 ]
𝑃𝑚𝑒𝑎𝑠𝑢𝑟𝑒 , 𝑐𝑙𝑜𝑠𝑒𝑑
Pool Closed – Required Flow Rate (minimum 25 gpm, minimum 0.12 kW)
Pool Open – Required Flow Rate (minimum 25 gpm)
𝑄𝑜𝑝𝑒𝑛 [𝑔𝑝𝑚 ]= 𝑃𝑜𝑜𝑙𝑉𝑜𝑙𝑢𝑚𝑒[𝑔𝑎𝑙 ]
6h𝑜𝑢𝑟𝑠
𝑡𝑢𝑟𝑛𝑜𝑣𝑒𝑟∗60 𝑚𝑖𝑛
h𝑜𝑢𝑟𝑃𝑚𝑒𝑎𝑠𝑢𝑟𝑒 ,𝑜𝑝𝑒𝑛
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 12
Results
Application Type kWh Savings kW Reduction Therm Savings
ER 7,441 0.59 0
ROB 5,586 0.36 0
Results Averaging
• Exclude existing multi-speed pumps
• Exclude pumps > 3 HP
• Exclude pools where a single 3 HP pump cannot meet required flow rate
• Straight average
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 13
Issues and Concerns – Cal TF Comments
Abstract Review Comments from the Cal TF
Health specifications
• Methodology ensures that variable speed pool pumps meet health code.
Persistence issues
• Technician errors will be reduced by using qualified contractors and
offering training.
X ECM motor retrofit
• This is a separate measure to be considered.
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 14
Issues and Concerns – Future Updates
Field Testing in Progress
• Five sites currently being tested and monitored
• Preliminary results:
Site kWh Savings kW Reduction
1 TBD 0.40
2 TBD TBD
3 TBD TBD
4 TBD TBD
5 TBD TBD
Work Paper (ER) 7,441 0.59
EDISON INTERNATIONAL®
SM
Internal Use OnlyPage 15
Additional material and labor costs
• Permitting fees: Program works with county to reduce fees.
• Replacement flow meters, valves, etc. may be required. Costs are not
borne by program.
Turnover Requirements
• Many pumps not meeting turnover requirement (6 hours/turnover).
• Not SCE’s role to enforce code.
Issues and Concerns – Future Updates