effectively measures level with a unique, patented method

21
Effectively Measures Level with a Unique, Patented Method

Upload: lauren-francis

Post on 26-Dec-2015

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Effectively Measures Level with a Unique, Patented Method

Effectively Measures Level with a Unique, Patented Method

Page 2: Effectively Measures Level with a Unique, Patented Method

Patented principle of level measurement

More than 3500 tanks/silos currently using —since 1992

Designed for “difficult” applications

2

Page 3: Effectively Measures Level with a Unique, Patented Method

Tank heights up to 130’(and taller!)

Dielectric constants as low as 1.6(and lower!)

Up to 24 tanks per control unit(and more!)

3

Page 4: Effectively Measures Level with a Unique, Patented Method

Available in many semi-custom configurations for temperature and pressure

Intrinsically safe, CSA, CENELAC versions are available

4

Page 5: Effectively Measures Level with a Unique, Patented Method

A system has:

A Control Unit that can monitor up to 24 sensors

One or more Sensors of a variety of lengths and designs

Optional Inventory Software

5

Page 6: Effectively Measures Level with a Unique, Patented Method

How it works:

A change in impedance echoes the transmitted signal

The phase difference between transmitted and echoed signals determines level

Transmitsignal

Reflectedsignal is outof phase withtransmit

6

Page 7: Effectively Measures Level with a Unique, Patented Method

Different than MIR (radar):

Much lower frequency, less affected by noise

Does not use timing to determine length, less error and longer lengths

Transmitsignal

Reflectedsignal is outof phase withtransmit

7

Page 8: Effectively Measures Level with a Unique, Patented Method

Applications

Changing/low dielectric Dust/foam/vapor environments Grain elevators/multi-tank installations Tall/narrow silos

8

Designed for ‘Difficult’ Applications

Page 9: Effectively Measures Level with a Unique, Patented Method

Application

Changing dielectric only affects the intensity of the signal, not the presence of the signal

Not affected by changes in: Temperature Particle size Density Moisture content Very reliable at all lengths down to 1.6 dielectric

constant, some current installations have lower dielectric constants

9

Changing/Low Dielectric

Page 10: Effectively Measures Level with a Unique, Patented Method

Application

Because looks for the greatest impedance change and not the first impedance change, it can “see” through dust, foam and vapors in a way that technologies that rely on reflection cannot.

Ultrasonic, MIR and through-air radar will all reflect the first product they encounter which will generate a false reading in dust, foam, and vapor environments

10

Dust/Foam/Vapor Environments

Page 11: Effectively Measures Level with a Unique, Patented Method

Application

One control unit can control up to 24 sensors measuring dissimilar products in different size silos

There are many 48 tank systems and some 64 tank systems currently installed

System architecture allows a customer to add new sensors after original installation, which accommodates growth

11

Grain Elevators/Multi-tank Installations

Page 12: Effectively Measures Level with a Unique, Patented Method

Application

is transmitted along a specially designed cable that minimizes signal loss Very reliable to 130’, some current applications are

up to 150’ measures a 6” radius

around the sensor cable Not affected by corrugated side walls, cross

members Inherently immune to product coating

12

Tall, Narrow Silos

Page 13: Effectively Measures Level with a Unique, Patented Method

Control Unit 16 character LCD/ integral

keypad Setup, calibration, diagnostics and

tank level readout RS-232 and modem connection

All keypad functions can be performed remotely

4-20 mA outputs (optional) SPST relays for high and low

level alarm (optional) NEMA 4X molded enclosure

13

Page 14: Effectively Measures Level with a Unique, Patented Method

Sensors

Several sensor types: Tefzel jacketed steel (standard)

10’ to 130’ -140oF to 300oF

Sensors can be mounted up to 400’ from control unit

Several mountings and terminations available

Determined by application and sensortype

14

Page 15: Effectively Measures Level with a Unique, Patented Method

i-LEVEL software

Win 95/98 NT/2000/XP inventory management software

Use RS-232 or modem for remote management or inventory

Trending and data logging

Export data via DDE

15

Page 16: Effectively Measures Level with a Unique, Patented Method

Where to Sell

Food Manufacturing(SIC 311) Corn, flour, grain, wheat, starch, rice,

soy, animal food, nitrogen protein pellets, poultry meal, coffee

16

Beverage and Tobacco Manufacturing(SIC 312) Tobacco leaves, rice barley, corn, malt

Page 17: Effectively Measures Level with a Unique, Patented Method

Where to Sell

Brick, Clay, Glass, Concrete & other building products(SIC 327) Ceramic clay, kaolin clay, sand, silica, fly

ash, limestone powder, cement, gypsum, roofing granules, lime

17

Page 18: Effectively Measures Level with a Unique, Patented Method

Where to Sell

Plastics & Rubber Products (SIC 326) Calcium carbonate, PVA powder,

polyethylene powder, polystyrene pellets, polyethylene pellets, polypropylene pellets, ABS pellets, PET resin, PVC powder, nylon chips

18

Page 19: Effectively Measures Level with a Unique, Patented Method

Where to Sell

Chemical Manufacturing (SIC 325) Titanium oxide, zinc oxide, alumina, oils,

solvents, aluminum oxide, potassium carbonate, titanium dioxide, aluminum fluoride, talc powder

19

Page 20: Effectively Measures Level with a Unique, Patented Method

Where to Sell

Paper Manufacturing (SIC 322) Wood chips, starch, sodium sulfite

20

Mining (SIC 212) Limestone powder, salt, soda ash, talc

powder

Page 21: Effectively Measures Level with a Unique, Patented Method

Where to Sell

Iron, Steel, Aluminum & Copper Manufacturing(SIC 331) Limestone powder

21

Electric Power Generation (SIC 22111) Coal, fly ash