EGR 334 ThermodynamicsChapter 8: Sections 3-4
Lecture 32: Superheat, Reheat, andCogeneration Quiz Today?
![Page 2: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/2.jpg)
Today’s main concepts:• Explain how a superheater changes the Rankine cycle
model• Explain how a reheat line changes the Rankine cycle
model.• Explain how regenerative heating changes the Rankine
cycle model.• Explain how cogeneration and process steam lines
change the Rankine cycle model.• Be able to use mass balance, energy balance, and
entropy balance to solve systems with modified Rankine cycle models.Reading Assignment:
Homework Assignment:
Read Chapter 9, Sections 1-2
Problems from Chap 8: 21,29, 49, 60
![Page 3: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/3.jpg)
3Sec 8.1 : Modeling Vapor Power Systems
Vapor Power System Model
![Page 4: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/4.jpg)
Tools:
4Sec 8.2 : Rankine Cycle
Conservation of massConservation of energy (First Law)Entropy balance (Second Law)Thermodynamic properties
Energy balances:For the turbine:
For the condenser:
For the pump:
For the boiler:
![Page 5: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/5.jpg)
Process 1-2: Isentropic expansion of the fluid through the turbine from saturated vapor to the condenser pressure.
5Sec 8.2 : Rankine Cycle
Process 2-3: Heat transfer at constant pressure through the condenser to saturated liquid.
Process 3-4: Isentropic compression of fluid to compressed liquid.
Process 4-1: Heat transfer at constant pressure through the boiler to saturated vapor
![Page 6: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/6.jpg)
6Sec 8.2.2 : Modified Rankine Cycle
In addition to being able to work with the Ideal Rankine Cycle, you should also be prepared to evaluate performance that includes the following modifications
-- Superheating: Heating of the fluid past a saturated vapor and well into the superheated region by the steam generator.
-- Reheating: Reheating fluid after it has passed through one turbine and then passing through a second turbine at lower pressure.
-- Regenerative Feedwater Heating: A process where some of the steam is bled off and used to partially reheat the condensate from the condenser.
![Page 7: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/7.jpg)
7Sec 8.2.2 : Modified Rankine Cycle
In addition to being able to work with the Ideal Rankine Cycle, you should also be prepared to evaluate performance that includes the following modifications
-- Non-Ideal Rankine (with irreversibilities): Similar to the Ideal Rankine cycle except the processes through the turbine and pump are not isentropic. Turbine and pump efficiencies need to be used to determine work in each of the components.-- Cogeneration: A process where some of the steam is bled off for use by other parts of the plant, such as for heating, cleaning, etc.
![Page 8: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/8.jpg)
8Sec 8.3 : Superheat and Reheat
How can the efficiency of the Rankine cycle be increased?
As the temperature is raised, note that the sat. vapor location also shifts to the left, so that when the fluid expands through the turbine, a lower quality of the fluid is obtained. Why is this bad?
How can the cycle maintain high boiler Pressure and Temperature and still maintain a higher exit quality?
Superheat the steam.
Raise the Average High Temperature.
Net work is decreased as area under the curve get narrower and there are physical effects on the turbine that involve more blade wear. It is more desirable to have the exit quality of the steam, x2, be above 90%
![Page 9: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/9.jpg)
How is steam superheated?
9
![Page 10: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/10.jpg)
10Sec 8.3 : Superheat and Reheat
Superheating:It is not necessary to have the exit from the boiler be a saturated vapor (xboiler exit = 1).
Operate the boiler, such that the exit of the boiler is a superheated vapor.
The only difference in calculating cycle performance from the Ideal Rankine Cycle, is that state 3 is no longer expected to fall along the saturated vapor curve, but will be found on the superheated steam table.
![Page 11: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/11.jpg)
11Sec 8.3 : Superheat and Reheat
When Reheating is implemented, there is a multistage stage turbine (often identified as a High Pressure and Low Pressure turbine.)
Before vapor starts to condense (reaches saturation), the vapor is sent back to the boiler and reheated.
![Page 12: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/12.jpg)
12Sec 8.3 : Superheat and Reheat
This affects the Ideal Rankine Cycle model because there are additional states to determine properties for, a second pass through the turbine, and a second heat exchange with the boiler. Therefore, identify additional properties states (1, 2, 3, and 4) and then rework the 1st law equations as applied to the turbine and boiler.
and
Boiler Reheat Equation
![Page 13: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/13.jpg)
13Sec 8.4 : Regenerative Vapor Power Cycle
Regenerative Feedwater Heating. (regeneration)
Note: This rerouting will diminish the net work output. The reduction in Qboiler should be less than the reduction of Wcycle.
Steam is diverted to use in a mixing chamber to preheat the condensate prior to entering boiler. This is useful since water is typically cooled below saturated level out of the condensor.
![Page 14: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/14.jpg)
14Sec 8.4 : Regenerative Vapor Power Cycle
Open feedwater analysis:
Mass Balance:
#1
#2
#3Often will use the term “blend fraction”
consequently,
Energy Balance:
Thus:
![Page 15: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/15.jpg)
15
Energy balances:For the turbines:
For the condenser:
For the pump:
For the boiler:
Sec 8.4 : Regenerative Vapor Power Cycle
and
![Page 16: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/16.jpg)
16
Example (8.44): An Ideal Rankine cycle with the state properties given below includes one open feedwater heater operating at 100 psi. Saturated liquid exits the open feedwater heater at 100 psi. The mass flow rate of steam into the first turbine state is 1.4 x 106 lbm/hr. Determine
State 1 2 3 4 5 6 7
T (°F) 1100
p (psi) 1600
100
1 1 100
100
1600
x
h (Btu/lbm)
s (Btu/lbm K)
(a) The net power developed, in Btu/hr.
(b) The thermal efficiency.(c) The mass flow rate of cooling
water, if ΔT = 20°F.
![Page 17: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/17.jpg)
17
Example (8.44) continued:
State 1 2 3 4 5 6 7
T (°F) 1100
p (psi) 1600
100
1 1 100
100
1600
x
h (Btu/lbm)
s (Btu/lbm K)
Start by finding the state properties
State 1: Using Table A4E with T = 1100 F and p = 1600 psi, find h1 = 1547.7 and s1 = 1.6315
State 2: Using Table A4E with s2=s1 and p = 100 psi, find h2 = 1210.7 State 3: Using Table A3E with s3=s1, and p = 1 psi, find x3 = 81.2% and then, find h3 = 911.2 State 4: Using Table A3E with sat. liquid and p = 1 psi, find v4 = vf = 0.01614, h4 = hf = 69.74, and s4 = sf = 0.1327
![Page 18: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/18.jpg)
18
Example (8.44) continued:
State 1 2 3 4 5 6 7
T (°F) 1100
p (psi) 1600 100
1 1 100
100
1600
x s.h. s.h.
0.812
0.00 liq. 0.00
liq.
h (Btu/lbm)
1547.7
1210.7
911.2
69.74
70.04
298.6
303.5
s (Btu/lbm K)
1.6315
1.6315
1.6315
0.1327
0.4744
Start by finding the state properties
State 5: Using h5 - h4 =v4 (p5 - p4)
find h5 = 70.04
State 6: Using Table A4E with sat. liq. and p = 100 psi, find v6 = 0.01774 h6 = 298.6, and s6 = 0.4744 State 7: Using h7 - h6 =v6 (p7 - p6)
find h7 = 303.5
State 1 2 3 4 5 6 7
T (°F) 1100
p (psi) 1600
100
1 1 100
100
1600
x
h (Btu/lbm)
s (Btu/lbm K)
![Page 19: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/19.jpg)
19
Example (8.44) continued:
State 1 2 3 4 5 6 7
T (°F) 1100
p (psi) 1600 100
1 1 100
100
1600
x s.h. s.h.
0.812
0.00 liq. 0.00
liq.
h (Btu/lbm)
1547.7
1210.7
911.2
69.74
70.04
298.6
303.5
s (Btu/lbm K)
1.6315
1.6315
1.6315
0.1327
0.4744
Find heat in provided in boiler:
then
![Page 20: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/20.jpg)
20
Example (8.44) continued:
State 1 2 3 4 5 6 7
T (°F) 1100
p (psi) 1600 100
1 1 100
100
1600
x s.h. s.h.
0.812
0.00 liq. 0.00
liq.
h (Btu/lbm)
1547.7
1210.7
911.2
69.74
70.04
298.6
303.5
s (Btu/lbm K)
1.6315
1.6315
1.6315
0.1327
0.4744
Now find how the mass flow splits from the turbine
therefore:
c
![Page 21: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/21.jpg)
21
Example (8.44) continued:
State 1 2 3 4 5 6 7
T (°F) 1100
p (psi) 1600 100
1 1 100
100
1600
x s.h. s.h.
0.812
0.00 liq. 0.00
liq.
h (Btu/lbm)
1547.7
1210.7
911.2
69.74
70.04
298.6
303.5
s (Btu/lbm K)
1.6315
1.6315
1.6315
0.1327
0.4744
Find work from turbine
![Page 22: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/22.jpg)
22
Example (8.44) continued:
State 1 2 3 4 5 6 7
T (°F) 1100
p (psi) 1600 100
1 1 100
100
1600
x s.h. s.h.
0.812
0.00 liq. 0.00
liq.
h (Btu/lbm)
1547.7
1210.7
911.2
69.74
70.04
298.6
303.5
s (Btu/lbm K)
1.6315
1.6315
1.6315
0.1327
0.4744
Find heat provided to pumps:
Pump 1:
Pump 2:
![Page 23: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/23.jpg)
23
Example (8.44) continued:
State 1 2 3 4 5 6 7
T (°F) 1100
p (psi) 1600 100
1 1 100
100
1600
x s.h. s.h.
0.812
0.00 liq. 0.00
liq.
h (Btu/lbm)
1547.7
1210.7
911.2
69.74
70.04
298.6
303.5
s (Btu/lbm K)
1.6315
1.6315
1.6315
0.1327
0.4744
therefore the Net Work
Plant thermal efficiency:
![Page 24: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/24.jpg)
24
Example (8.44) continued:
State 1 2 3 4 5 6 7
T (°F) 1100
p (psi) 1600 100
1 1 100
100
1600
x s.h. s.h.
0.812
0.00 liq. 0.00
liq.
h (Btu/lbm)
1547.7
1210.7
911.2
69.74
70.04
298.6
303.5
s (Btu/lbm K)
1.6315
1.6315
1.6315
0.1327
0.4744
for the condenser:
![Page 25: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/25.jpg)
25Sec 8.2.4 : Principal Irreversibilities and Losses
NonIdeal Rankine Cycle.
For real processes, there is some heat transfer with the surroundings, and thus an increase in entropy. In the turbine and pump, this can be quantified using the isentropic efficiencies.
But, for a real process, the inefficiencies associated with combustion are more significant. These, however, are external to the power cycle, so are not analyzed as part of the Rankine Cycle analysis.
For Turbine:
For Pump:
![Page 26: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/26.jpg)
Cogeneration Systems
Cogeneration systems provide both electrical work out and process steam or hot water for use by an end user which is often a commerical, industrial, or governmental user.
Steam exported to the community
Electricity provided to the community
![Page 27: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/27.jpg)
Cogeneration Systems--Exporting useful steam to the community limits the electricity that also can be provided from a given fuel input, however.
--For instance, to produce saturated vapor at 100oC (1 atm) for export to the community water circulating through the power plant will condense at a higher temperature and thus at a higher pressure.
--In such an operating mode thermal efficiency is less than when condensation occurs at a pressure below 1 atm, as in a plant fully dedicated to power production.
T > 100oCp > 1 atm
![Page 28: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/28.jpg)
28Sec 8.4.3 : Multiple Feedwater Heaters
As closing comment: You now have most of the tools you would need to analyze some relatively complicated vapor power generation units and be able to discuss their respective efficiencies or how to suggest improvements in their performance... (not that you would want to).
![Page 29: EGR 334 Lecture 32 Superheating and Regeneration.ppt](https://reader034.vdocument.in/reader034/viewer/2022052603/55cf98d9550346d0339a07c0/html5/thumbnails/29.jpg)
End of Lecture 32 slides
So ends Chap 8!
29