electrical components for the railway industry
TRANSCRIPT
Unrestricted / © Siemens AG 2014. All Rights Reserved. www.siemens.com/railway-components
Electrical Components for the
Railway Industry
Surge Arresters - Reliable, stable and safe overvoltage protection
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 2 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Introduction
3EB1 3EB4 3EL2 3EC3
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 3 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Description
3EB1 silicone rubber surge
arresters with composite hollow
core design
• Housing made of FRP tube and silicone rubber sheds
• For AC systems up to 25 kV
• For DC systems up to 3 kV
• Travel speed up to 360 km/h
• Short circuit current capability 40 kA
• Tested according to IEC 60099-4 (AC) and EN 50526-1 (DC)
• Fire test according to EN 45545-2
• Shock and vibration test according to IEC 61373
• For use on:
• High-speed and intercity trains
• (Multi-traction) locomotives
Description
FRP: fibre reinforced plastic
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 4 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Description
3EB4 silicone rubber surge
arresters with composite hollow
core design
• Housing made of FRP tube and silicone rubber sheds
• For AC systems up to 25 kV
• For DC systems up to 3 kV
• Travel speed up to 320 km/h
• Short circuit current capability 40 kA
• Tested according to IEC 60099-4 (AC) and EN 50526-1 (DC)
• Fire test according to EN 45545-2
• Shock and vibration test according to IEC 61373
• For use on:
• High-speed and intercity trains
• Commuter and regional trains
• (Multi-traction) locomotives
• Urban transport (light rail, metros and tram cars)
Description
FRP: fibre reinforced plastic
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 5 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Customer benefits
3EB1 / 3EB4 silicone rubber surge
arresters with composite hollow
core design
Stable, safe and long lasting
• Design and excellent sealing system:
• No moisture ingress, no failures
• No voids = no partial discharges
• Safe overload performance:
• No shattering/splintering of the housing
• No ejection of internal parts – no damage to surrounding
equipment or injury to persons
• Silicone rubber:
• Hydrophobic
• Low flash-over probability
• UV resistant: no erosion or aging effects
• Self cleaning: diffusion transfer to pollution layers
• Self-extinguishing properties
MOV: metal oxide varistors
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 6 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Description
3EL2 silicone rubber surge
arresters with Cage Design™ • Cage Design™ housing with silicone rubber sheds
• For AC systems up to 25 kV
• Travel speed up to 320 km/h
• Short circuit current capability 65 kA
• Tested according to IEC 60099-4
• Fire test according to EN 45545-2
• Shock and vibration test according to IEC 61373
• For use on:
• High-speed and intercity trains
• Commuter and regional trains
• (Multi-traction) locomotives
Description
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 7 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Customer benefits
3EL2 silicone rubber surge
arresters with Cage Design™
Stable, safe and long lasting
• Directly molded silicone rubber:
• No moisture ingress, no failures
• No voids = no partial discharges
• Safe overload performance:
• No shattering/splintering of the housing
• No ejection of internal parts – no damage to surrounding
equipment or injury to persons
• Silicone rubber:
• Hydrophobic
• Low flash-over probability
• UV resistant: no erosion or aging effects
• Self cleaning: diffusion transfer to pollution layers
• Self-extinguishing properties
MOV: metal oxide varistors
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 8 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Description
3EC3 porcelain rubber surge
arresters
• Porcelain housing
• For DC systems up to 3 kV
• Travel speed up to 160 km/h
• Short circuit current capability 40 kA
• Tested according to EN 50526-1
• Shock and vibration test according to IEC 61373
• For use on:
• Commuter and regional trains
• Locomotives
• Urban transport (light rail, metros and streetcars)
Description
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 9 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Technical Data
Product line 3EB1 3EB4 3EL2
Nominal system voltage Un [kV AC] 25 25 25
Maximum rated voltage Ur [kV AC] 45 45 45
Maximum continuous operating voltage Uc [kV AC] 36 36 36
Maximum travel speed V [km/h] 360 320 320
Rated short circuit current Is [kA] 40 40 65
Surge arresters for AC applications
Maximum values
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 10 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Technical Data
Product line 3EB1 3EB4 3EC3
Nominal system voltage Un [kV DC] 3.0 3.0 3.0
Maximum rated voltage Ur [kV DC] 4.0 4.8 4.0
Maximum continuous operating voltage Uc [kV DC] 4.0 4.8 4.0
Maximum travel speed V [km/h] 360 320 160
Rated short circuit current Is [kA] 40 40 40
Classification according to EN 50526-1 DC-B DC-B DC-B
Surge arresters for DC applications
Maximum values
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 11 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Versions AC applications
3EB1 silicone rubber surge arresters
with composite hollow core design
AC versions
Arrester type
Rated
voltage
[kV AC]
Continuous
operating
voltage
[kV AC]
Nominal
discharge
voltage
[kA]
Thermal
energy
rating
[kJ]
Charge
transfer
rating
[C]
Creepage
distance
[mm]
3EB1 230-5AL22-0A 23 18 10 97 1.2 460
3EB1 230-6AL22-0A 23 18 10 161 2.0 460
3EB1 370-5AX22-0A 37 30 10 155 1.2 800
3EB1 370-6AX22-0A 37 30 10 259 2.0 800
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 12 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Versions AC applications
3EB4 silicone rubber surge arresters
with composite hollow core design
AC versions
Arrester type
Rated
voltage
[kV AC]
Continuous
operating
voltage
[kV AC]
Nominal
discharge
voltage
[kA]
Thermal
energy
rating
[kJ]
Charge
transfer
rating
[C]
Creepage
distance
[mm]
3EB4 230-5AL32-0D / -0E 23 18 10 115 1.2 715
3EB4 230-6AL32-0D / -0E 23 18 10 161 2.0 715
3EB4 230-7AL32-0D / -0E 23 18 20 207 2.4 715
3EB4 370-5AX32-0D / -0E 37 30 10 185 1.2 1180
3EB4 370-6AX32-0D / -0E 37 30 10 259 2.0 1180
3EB4 370-7AX32-0D / -0E 37 30 20 333 2.4 1180
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 13 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Versions AC applications
3EB4 silicone rubber surge arresters
with composite hollow core design
AC versions
Arrester type
Rated
voltage
[kV AC]
Continuous
operating
voltage
[kV AC]
Nominal
discharge
voltage
[kA]
Thermal
energy
rating
[kJ]
Charge
transfer
rating
[C]
Creepage
distance
[mm]
3EB4 420-5AX32-0D / -0E 42 34 10 210 1.2 1180
3EB4 420-6AX32-0D / -0E 42 34 10 294 2.0 1180
3EB4 420-7AX32-0D / -0E 42 34 20 378 2.4 1180
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 14 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Versions AC applications
3EL2 silicone rubber surge arresters
with Cage Design™
AC versions
Arrester type
Rated
voltage
[kV AC]
Continuous
operating
voltage
[kV AC]
Nominal
discharge
voltage
[kA]
Thermal
energy
rating
[kJ]
Charge
transfer
rating
[C]
Creepage
distance
[mm]
3EL2 023-2RC31-4XA0 23 18 10 161 2.0 1470
3EL2 023-6RC41-4XA0 23 18 20 207 2.4 1470
3EL2 037-2RC31-4XA0 37 30 10 259 2.0 1470
3EL2 037-6RC41-4XA0 37 30 20 333 2.4 1470
3EL2 042-2RC31-4XA0 42 34 10 294 2.0 1470
3EL2 042-6RC41-4XA0 42 34 20 378 2.4 1470
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 15 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Versions DC applications
3EB1 silicone rubber surge arresters
with composite hollow core design
DC versions
Arrester type
Rated
voltage
[kV DC]
Continuous
operating
voltage
[kV DC]
Nominal
discharge
voltage
[kA]
Thermal
energy
rating
[kJ]
Charge
transfer
rating
[C]
Creepage
distance
[mm]
3EB1 010-7DS22-0A 1.0 1.0 20 10 2.5 125
3EB1 010-7DM22-0A 1.0 1.0 20 10 2.5 230
3EB1 020-7DS22-0A 2.0 2.0 20 20 2.5 125
3EB1 020-7DM22-0A 2.0 2.0 20 20 2.5 230
3EB1 040-7DS22-0A 4.0 4.0 20 40 2.5 125
3EB1 040-7DM22-0A 4.0 4.0 20 40 2.5 230
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 16 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Versions DC applications
3EB4 silicone rubber surge arresters
with composite hollow core design
DC versions
Arrester type
Rated
voltage
[kV DC]
Continuous
operating
voltage
[kV DC]
Nominal
discharge
voltage
[kA]
Thermal
energy
rating
[kJ]
Charge
transfer
rating
[C]
Creepage
distance
[mm]
3EB4 010-7DS32-0D / -0E 1.0 1.0 20 10 2.5 249
3EB4 010-7DM32-0D / -0E 1.0 1.0 20 10 2.5 404
3EB4 020-7DS32-0D / -0E 2.0 2.0 20 20 2.5 249
3EB4 020-7DM32-0D / -0E 2.0 2.0 20 20 2.5 404
3EB4 040-7DS32-0D / -0E 4.0 4.0 20 40 2.5 249
3EB4 040-7DM32-0D / -0E 4.0 4.0 20 40 2.5 404
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 17 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Surge arresters for rail applications
Versions DC applications
3EC3 porcelain surge arresters
DC versions
Arrester type
Rated
voltage
[kV DC]
Continuous
operating
voltage
[kV DC]
Nominal
discharge
voltage
[kA]
Thermal
energy
rating
[kJ]
Charge
transfer
rating
[C]
Creepage
distance
[mm]
3EC3 010 1.0 1.0 20 10 2.5 165
3EC3 020 2.0 2.0 20 20 2.5 165
3EC3 040 4.0 4.0 20 40 2.5 165
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 18 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters Dimension Drawing 3EB1
Surge arresters for rail applications
Drawings
Arrester
housing
Height
[mm]
Creepage
distance
[mm]
Flashover
distance
[mm]
3EB1 …-..S2.-.. 188 125 100
3EB1 …-..S2.-.. 223 230 130
3EB1 …-..L2.-.. 293 460 195
3EB1 …-..X2.-.. 422 800 297
Mounting:
3EB1 …-…..-0A
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 19 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters Dimension Drawing 3EB4
Surge arresters for rail applications
Drawings
Mounting:
3EB4 …-…..-0D
Arrester
housing
Height
[mm]
Creepage
distance
[mm]
Flashover
distance
[mm]
3EB4 …-..S3.-.. 155 249 94
3EB4 …-..S3.-.. 195 404 127
3EB4 …-..L3.-.. 275 715 215
3EB4 …-..X3.-.. 395 1180 314
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 20 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters Dimension Drawing 3EB4 – Adapter plate for POLIM
Surge arresters for rail applications
Drawings
Arrester
housing
Height
[mm]
Creepage
distance
[mm]
Flashover
distance
[mm]
3EB4 …-..S3.-.. 155 249 94
3EB4 …-..S3.-.. 195 404 127
3EB4 …-..L3.-.. 275 715 215
3EB4 …-..X3.-.. 395 1180 314
Mounting:
3EB4 …-…..-0E
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 21 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters Dimension Drawing 3EL2
Surge arresters for rail applications
Drawings
Arrester
housing
Height
[mm]
Creepage
distance
[mm]
Flashover
distance
[mm]
3EL2 …-.RC.1-4... 482 1470 405
3EL2 …-.RF.1.-4… 705 2340 630
Mounting:
3EL2 …-…..-...0
Connection:
3EL2 …-…..-.X..
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 22 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters Dimension Drawing 3EC3
Surge arresters for rail applications
Drawings
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 23 Michael Staber, Railway Presentation V7.2
► Drawings
► Versions DC
► Versions AC
► Technical Data
► Description &
benefits
► Introduction
► Surge arresters
Disclaimer
The information provided in this brochure comprises descriptions or performance
characteristics which may not always be applicable in the described form to the
specific application case or which may change due to product advancement.
The desired performance characteristics shall only be binding if they are
expressly specified upon contract conclusion. Subject to availability and technical
changes.
All product designations may be trademarks or product names of Siemens AG or
supplier companies whose utilization by third parties for their own purposes could
violate the rights of the owners.
Unrestricted / © Siemens AG 2014. All Rights Reserved.
2014-09-12 Page 24 Michael Staber, Railway Presentation V7.2
Koch Thomas
Area Sales Manager / Business Developer
E T HP AR S 1
Nonnendammallee 104
13629 Berlin
Phone: +49 (30) 386-22022
Cellular: +49 (173) 497-4338
E-Mail: [email protected]