Electrical Components for the

Railway Industry

SIRIUS – 3RT2 motor contactors up to 37 kW

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 2 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Introduction

Contactors S00

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 3 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Description

Contactors S00

• Spring-loaded and screw-type connection system on all terminals

(also ring cable lug connection upon request)

• Solenoid coil with suppressor diode or varistor circuit

• For screw and snap-on mounting on DIN rail

• Extended operating range: 0.7 – 1.25 x Us

• Communication via IO-Link with stationary applications

• Mounting:

• With series resistor: Without clearance up to ambient temperatures

of 70 °C

• Without series resistor: Side-by-side mounting with minimum clearance

of 10 mm with ambient temperatures exceeding 60 °C

• Contacts:

• With series resistor: Attachment option for 4-pole auxiliary switch block

in accordance with DIN EN 50005

• Without series resistor: No attachment option for auxiliary switches

Description

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 4 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Technical Data

Contactors S00

Without resistor With resistor

Article-No. 3RT2015 3RT2016 3RT2017 3RT2018

Power kW / 400V 3 4 5.5 7.5

Currents

[A]

DC-1 / 24V

DC-1 / 110V

15

1.5

20

2.1

DC-3;5 / 24V

DC-3;5 / 110V

15

0,1

20

0.1

Coil power

[W]

Closing

Holding

2.8

2.8

12

4

Weight [ kg / PE ] 0.28 0.30

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 5 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 3 kW without circuit

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2015 - 1 1HB41 2HB41 24V DC

1 1HB42 2HB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 6 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 3 kW with diode

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2015 - 1 1JB41 2JB41 24V DC

1 1JB42 2JB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 7 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 3 kW with suppressor diode

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2015 - 1 1KB41 2KB41 24V DC

1 2KA42 12V DC

1 1KB42 2KB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 8 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 3 kW with varistor

NO NC Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2015 - 1 1QB41 2QB41 24V DC

1 1QB42 2QB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 9 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 4 kW without circuit

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2016 - 1 1HB41 2HB41 24V DC

1 1HB42 2HB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 10 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 4 kW with diode

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2016 - 1 1JB41 2JB41 24V DC

1 1JB42 2JB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 11 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 4 kW with diode

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2016 - 1 2FB41 – 1AA0 24V DC

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 12 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 4 kW with suppressor diode

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2016 - 1 1KB41 2KB41 24V DC

1 2KA42 12V DC

1 1KB42 2KB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 13 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 4 kW with varistor

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2016 - 1 1QB41 2QB41 24V DC

1 1QB42 2QB42 24V DC

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 14 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 4 kW with varistor and series resistor

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2016 - 1 2LJ82 – 0LA0 72V DC

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 15 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW without circuit

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2017 - 1 1HB41 2HB41 24V DC

1 1HB42 2HB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 16 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with diode

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2017 - 1 1JB41 2JB41 24V DC

1 1JB42 2JB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 17 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with diode

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Article-No. Connection diagram Screw-type Control voltage Us

3RT2017 - 1 1FB41 – 1AA0 24V DC

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 18 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with suppressor diode

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2017 - 1 2KA42 12V DC

1 1KB41 2KB41 24V DV

1 1KB42 2KB42 24V DC

1 2KF41 110V DC

1 2KF42 110V DC

1 2KG41 125V DC

1 2KG42 125V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 19 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with suppressor diode

Article-No. Connection diagram Ring-terminals Control voltage Us

3RT2017 - 1 4KB41 24V DC

1 4KB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 20 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with varistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2017 - 1 2LB41 24V DC

1 2LB42 24V DC

1 2LF41 110V DC

1 2LF42 110V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 21 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with varistor

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2017 - 1 1QB41 2QB41 24V DC

1 1QB42 2QB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 22 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with varistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2017 - 1 2LB41 – 1AA0 24V DC

1 2LB42 – 1AA0 24V DC

With series resistor

Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 23 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with varistor

Article-No. Connection diagram Ring-terminals Control voltage Us

3RT2017 - 1 4LB41 24V DC

1 4LB42 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 24 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with suppressordiode and series resistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2017 - 1 2KF41 – 1AA0 110V DC

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 25 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with suppressordiode and series resistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2017 - 1 2KB42 - 0LA0 24V DC

1 2KF42 - 0LA0 110V DC

1 2KG42 - 0LA0 125V DC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 26 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with suppressordiode and series resistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2017 - 1 2KB42 - 1LA0 24V DC

1 2KF42 - 1LA0 110V DC

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 27 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with varistor and series resistor

Article-No. Connection diagram Ring-terminals Control voltage Us

3RT2017 - 1 4KB42 - 0LA0 24V DC

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 28 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with varistor and series resistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2017 - 1 2LB42 - 0LA0 24V DC

1 2LF42 - 0LA0 110V DC

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 29 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with varistor and series resistor

Article-No. Connection diagram Ring-terminals Control voltage Us

3RT2017 - 1 4LB42 - 0LA0 24V DC

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 30 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with varistor and series resistor

Circuit diagram

With series resistor

Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2017 - 1 2LB42 - 1LA0 24V DC

1 2LF42 - 1LA0 110V DC

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 31 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 5.5 kW with varistor and series resistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2017 - 1 2LJ82 – 0LA0 72V DC

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 32 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 7.5 kW with suppressor diode and series resistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2018 - 1 2KB42 - 0LA0 24V DC

1 2KF42 - 0LA0 110V DC

1 2KG42 - 0LA0 125V DC

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 33 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 7.5 kW with suppressor diode and series resistor

Article-No. Connection diagram Ring-terminals Control voltage Us

3RT2018 - 1 4KB42 - 0LA0 24V DC

1 4KJ82 - 0LA0 72V DC

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 34 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 7.5 kW with suppressor diode and series resistor

Article-No. Connection diagram Spring-loaded Control voltage Us

3RT2018 - 1 2LB42 - 0LA0 24V DC

1 2LJ82 - 0LA0 72V DC

1 2LF42 - 0LA0 110V DC

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 35 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 7.5 kW with varistor and series resistor

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Article-No. Connection diagram Spring-loaded Steuerspannung Us

3RT2018 -

1 2LB42 - 1LA0 24V DC

1 2LB42 – 2LA0 24V DC

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 36 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► 7.5 kW

► 5.5 kW

► 4 kW

► 3 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Versions

Size S00

Power = 7.5 kW with varistor and series resistor

Article-No. Connection diagram Ring-terminals Control voltage Us

3RT2018 - 1 4LB42 - 0LA0 24V DC

NO NC

Circuit diagram

With series resistor Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 37 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 7.5 kW

Drawings

Dimension drawing

3RT2 with resistor 3RT2 without resistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 38 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Introduction

Contactors S0

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 39 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Description

Contactors S0

• Spring-loaded and screw-type connection system on all terminals

(also ring cable lug connection upon request)

• Coil with suppressor diode or varistor circuit

• For screw and snap-on mounting on DIN rail

• Extended coil operating range: 0.7 – 1.25 x Us

• Communication via IO-Link with stationary applications

• Mounting:

• With resistor/ electronic coil: clearance up to ambient temperatures

of 70 °C is not required

• Without resistor: minimum lateral clearance of 10mm for ambient

temperatures exceeding 60 °C

• Auxiliaries:

• With resistor/ electronic coil: the addition of contact blocks is

allowed

• Without resistor: the addition of auxiliary contact blocks is not

allowed

Description

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 40 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Technical Data

Contactors S0

Standard coil With solid-state operating

mechanism

Currents

[A]

1 conducting path

Ie DC-1 / 24V

Ie DC-1 / 110V

35

4.5

Ie DC-3 / 24V

Ie DC-3 / 110V

20

2.5

Coil power

[W]

Closing

Holding

4.5

4.5

6.7

0.8

Weight [ kg / PE ] 0.58 / 0.60 0.58

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 41 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 4 kW with varistor

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2023 - 1 1 1KB40 2KB40 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 42 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Technical Data

Size S0

Power = 4 kW with varistor and electronic DC coil

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2023 - 1 1 4XB40 – 0LA2 24V DC

4XJ40 – 0LA2 72V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 43 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 5.5 kW with varistor

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2024 - 1 1 1KB40 2KB40 24V DC

NO NC

Without series resistor Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 44 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 5.5 kW with electronic UC coil

* with 280V upper limit 1,1xUs

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2024 - 1 1 1NB30 2NB30 21... 28V UC

1NF30 2NF30 95...130V UC

1NP30 2NP30 200...280V UC*

Particularities Operating range: 0.7 … 1.3 x Us = 21...28V / 14.7...36,4V

= 95...130V / 66,5...169V

= 200...280V / 140...308V

No attachment option for auxiliary switches

Operating temperature up to 60°C

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 45 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 5.5 kW with varistor and electronic DC coil

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2024 - 1 1 2XJ40 – 0LA2 72V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 46 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 5.5 kW with varistor and electronic DC coil

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2024 - 1 1 4XB40 – 0LA2 24V DC

4XJ40 – 0LA2 72V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 47 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 7.5 kW with varistor

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2025 - 1 1 1KB40 2KB40 24V DC

2KF40 110V DC

2KG40 125V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 48 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 7.5 kW with varistor

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2025 - 1 1 4KB40 24V DC

4KJ40 72V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 49 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 7.5 kW with electronic UC coil

* with 280V upper limit 1,1xUs

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2025 - 1 1 1NB30 2NB30 21... 28V UC

1NF30 2NF30 95...130V UC

1NP30 2NP30 200...280V UC*

NO NC

Particularities Operating range: 0.7 … 1.3 x Us = 21...28V / 14.7...36,4V

= 95...130V / 66,5...169V

= 200...280V / 140...308V

No attachment option for auxiliary switches

Operating temperature up to 60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 50 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 7.5 kW with varistor and electronic DC coil

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2025 - 1 1 2XB40 – 0LA2 24V DC

2XF40 – 0LA2 110V DC

2XG40 – 0LA2 125V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 51 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 7.5 kW with varistor and electronic DC coil

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2025 - 1 1 4XB40 – 0LA2 24V DC

4XJ40 – 0LA2 72V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 52 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 7.5 kW with varistor and electronic DC coil

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2025 - 1 1 2XF40 – 1LA2 110V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 53 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 11 kW with varistor

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2026 - 1 1 2KA40 12V DC

1KB40 2KB40 24V DC

2KF40 110V DC

2KG40 125V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 54 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 11 kW with varistor

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2026 - 1 1 4KB40 24V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

No attachment option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 55 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – Motorschütze 3RT2 bis 18,5 kw

Ausführungen

Size S0

Power = 11 kW with diode combination

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2026 - 1 1 4VB40 24V DC

S Ö

Particularities Operating range: 0.7 … 1.25 x Us

No expansion option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 56 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 11 kW with electronic UC coil

* with 280V upper limit 1,1xUs

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2026 - 1 1 1NB30 2NB30 21... 28V UC

1 1 1NF30 2NF30 95...130V UC

1 1 1NP30 2NP30 200...280V UC*

NO NC

Particularities Operating range: 0.7 … 1.3 x Us = 21...28V / 14.7...36,4V

= 95...130V / 66,5...169V

= 200...280V / 140...308V

No attachment option for auxiliary switches

Operating temperature up to 60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 57 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 11 kW with varistor and electronic DC coil

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2026 - 1 1 2XB40 – 0LA2 24V DC

1 1 2XJ40 – 0LA2 72V DC

1 1 2XF40 – 0LA2 110V DC

1 1 2XG40 – 0LA2 125V DC

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 58 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 11 kW with varistor and electronic UC coil

Article-No. Connection diagram Screw-type Voltage Us

3RT2026 - 2 2 1XB40 – 0LA2 24V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 59 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 11 kW with varistor and electronic DC coil

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2026 - 1 1 4XB40 – 0LA2 24V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 60 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 11 kW with varistor and electronic DC coil

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2026 - 1 1 2XB40 – 1LA2 24V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 61 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 11 kW with varistor and electronic DC coil

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2326 - 1 1 2XB40 – 0LA2 24V DC

S Ö

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 62 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 11 kW with varistor and electronic DC coil

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2326 - 2 2 2XJ40 – 0LA2 72V DC

S Ö

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 63 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 15 kW with varistor

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2027 - 1 1 2KA40 12V DC

1KB40 2KB40 24V DC

2KF40 110V DC

2KG40 125V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

No expansion option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 64 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 15 kW with varistor

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2027 - 1 1 4KB40 24V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

No expansion option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 65 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 15 kW with diode combination

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2027 - 1 1 4VB40 24V DC

4VF40 110V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

No expansion option for auxiliary switches

A clearance of 10 mm is required for side-by-side mounting at ambient temperatures

>60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 66 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 15 kW with suppressor diode and series resistor

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2027 - 1 1 4KF40 - 0RB0 110V DC

Circuit diagram

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Mounting without clearance up to ambient temperatures of 70°C

1 NC contact is wired to the series resistor

NO NC

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 67 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 15 kW with electronic UC coil

* with 280V upper limit 1,1xUs

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2027 - 1 1 1NB30 2NB30 21... 28V UC

1 1 1NF30 2NF30 95...130V UC

1 1 1NP30 2NP30 200...280V UC*

NO NC

Particularities Operating range: 0.7 … 1.3 x Us = 21...28V / 14.7...36,4V

= 95...130V / 66,5...169V

= 200...280V / 140...308V

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 68 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 15 kW with varistor and electronic DC coil

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2027 - 1 1 2XB40 – 0LA2 24V DC

1 1 2XJ40 – 0LA2 72V DC

1 1 2XF40 – 0LA2 110V DC

1 1 2XG40 – 0LA2 125V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 69 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 15 kW with varistor and electronic DC coil

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2027 - 1 1 4XB40 – 0LA2 24V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 70 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 18.5 kW with electronic UC coil

* with 280V upper limit 1,1xUs

Article-No. Connection diagram Screw-type Spring-loaded Voltage Us

3RT2028 - 1 1 1NB30 2NB30 21... 28V UC

1 1 1NF30 2NF30 95...130V UC

1 1 1NP30 2NP30 200...280V UC*

NO NC

Particularities Operating range: 0.7 … 1.3 x Us = 21...28V / 14.7...36,4V

= 95...130V / 66,5...169V

= 200...280V / 140...308V

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 60°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 71 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 18.5 kW with varistor and electronic DC coil

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2028 - 1 1 2XB40 – 0LA2 24V DC

1 1 2XJ40 – 0LA2 72V DC

1 1 2XF40 – 0LA2 110V DC

1 1 2XG40 – 0LA2 125V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 72 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► 18.5 kW

► 15 kW

► 11 kW 4-pole

► 11 kW

► 7.5 kW

► 5.5 kW

► 4 kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Versions

Size S0

Power = 18.5 kW with varistor and electronic DC coil

Article-No. Connection diagram Ring-terminals Voltage Us

3RT2028 - 1 1 4XB40 – 0LA2 24V DC

NO NC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 73 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Drawings

Dimension drawing

3RT202 motor contactors - Spring-loaded connection system on all terminals

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 74 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Drawings

Dimension drawing

3RT202 motor contactors - screw-type connection system on all terminals

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 75 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 18.5 kW

Drawings

3RT202 motor contactors - Ring-terminals

Dimension drawing

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 76 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Introduction

Contactors S2

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 77 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Description

Contactors S2 Description

• Spring-loaded and screw-type connection system on all terminals

(also ring cable lug connection upon request)

• Coil with suppressor diode or varistor circuit

• For screw and snap-on mounting on DIN rail

• Extended coil operating range: 0.7 – 1.25 x Us

• Communication via IO-Link with stationary applications

• Mounting:

• With resistor/ electronic coil: clearance up to ambient temperatures

of 70 °C is not required

• Without resistor: minimum lateral clearance of 10mm for ambient

temperatures exceeding 60 °C

• Auxiliaries:

• With resistor/ electronic coil: the addition of contact blocks is

allowed

• Without resistor: the addition of auxiliary contact blocks is not

allowed

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 78 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Technical Data

Contactors S2

18,5kW 22kW 30kW 37kW

Currents

[A]

1 conducting path

Ie DC-1 / 24V

Ie DC-1 / 110V

55

4,5

60

4,5

70

4,5

75

4,5

Ie DC-3 / 24V

Ie DC-3 / 110V

35

2,5

35

2,5

35

2,5

35

2,5

Coil power

[W]

Einschalten

Halten

23

1

23

1

23

1

23

1

Weight [ kg / PE ] [ kg / PE ] 1,121

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 79 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Screw-type Voltage Us

3RT2035 - 1 1 1XB40-0LA2 24V DC

1XF40-0LA2 110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 18.5 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 80 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2035 - 1 1 3XB40-0LA2 24V DC

3XF40-0LA2 110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 18.5 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 81 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2035 - 2 2 3XB44-0LA2 24V DC

3XJ40-0LA2 72V DC

3XF44-0LA2

110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 18.5 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 82 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Screw-type Voltage Us

3RT2036 - 1 1 1XB40-0LA2 24V DC

1XF40-0LA2 110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 20 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 83 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2036 - 1 1 3XB40-0LA2 24V DC

3XF40-0LA2 110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 20 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 84 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2036 - 2 2 3XB44-0LA2 24V DC

3XJ40-0LA2 72V DC

3XF44-0LA2

110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 20 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 85 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Screw-type Voltage Us

3RT2037 - 1 1 1XB40-0LA2 24V DC

1XF40-0LA2 110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 30 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 86 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2037 - 1 1 3XB40-0LA2 24V DC

3XF40-0LA2 110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 30 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 87 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2037 - 2 2 3XB44-0LA2 24V DC

3XF44-0LA2 110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 30 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 88 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Screw-type Voltage Us

3RT2038 - 1 1 1XB40-0LA2 24V DC

1XF40-0LA2 110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 37 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 89 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2038 - 1 1 3XB40-0LA2 24V DC

3XF40-0LA2 110V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 37 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 90 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► 37kW

► 30kW

► 20kW

► 18.5kW

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Versions

Article-No. Connection diagram Spring-loaded Voltage Us

3RT2038 - 2 2 3XB44-0LA2 24V DC

Particularities Operating range: 0.7 … 1.25 x Us

Expansion of auxiliary switches analogous to standard contactors

Operating temperature up to 70°C

NO NC

Size S2

Power = 37 kW with varistor

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 91 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Drawings

Dimension drawing

3RT203 motor contactors – Screw-type

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 92 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Drawings

Dimension drawing

3RT203 motor contactors – Spring-loaded

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 93 Michael Staber, Railway Presentation V 7.3

► Important links

► Drawings

► Versions

► Technical Data

► Description

► Introduction

► Contactors S2

► Contactors S0

► Contactors S00

SIRIUS – 3RT2 motor contactors up to 37 kW

Drawings

Dimension drawing

3RT203 motor contactors – Spring-loaded

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 94 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Contactors S00

Important links

Important links

Industrial Controls: Sirius full-range portfolio

www.siemens.com/sirius

Industry Mall: Platform for e-business and product information

www.siemens.com/industrial-controls/mall

Online Support: Comprehensive technical product information

www.siemens.com/industrial-controls/support

Technical Assistance: Competent technical consulting

Internet www.siemens.com/industrial-controls/technical-assistance

E-mail [email protected]

Telephone +49 (911) 895-5900

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 95 Michael Staber, Railway Presentation V 7.3

► Important links

► Contactors S2

► Contactors S0

► Contactors S00

Disclaimer

The information provided in this brochure comprises descriptions or performance

characteristics which may not always be applicable in the described form to the

specific application case or which may change due to product advancement.

The desired performance characteristics shall only be binding if they are

expressly specified upon contract conclusion. Subject to availability and technical

changes.

All product designations may be trademarks or product names of Siemens AG or

supplier companies whose utilization by third parties for their own purposes could

violate the rights of the owners.

Unrestricted / © Siemens AG 2014. All Rights Reserved.

2014-10-27 Page 96 Michael Staber, Railway Presentation V 7.3

Staber Michael

Siemens AG

DF CP S&MK V&KAM

Breslauer Strasse 5

90766 Fuerth, Germany

Phone: +49 (911) 750 - 9042

Cellular: +49 (179) 2212179

E-Mail: [email protected]

Thank you for your attention!

www.siemens.com/railway-components