background: electrical components for the railway industry
TRANSCRIPT
Electrical Components for the Railway Industry
Answers for industry.
2
Large temperature fluctuations, condensation, shocks, vibrations, electromagnetic
interferences, etc.: Electrical components for the railway industry have to offer safe
and reliable operation even under extreme application conditions – permanently.
This is why nothing must be left to chance already during the development of these
components: Substantial technology and sector know-how have to go hand in hand
with maximum quality standards. This approach is characteristic of Siemens.
We have been acting as a reliable and experienced partner in the railway industry for
decades. Our comprehensive experience in the fields of rolling stock and infrastructure
is directly incorporated in the development of our electrical components – as is our know-
ledge gained from close cooperation with international standards committees. You can
thus rely on our components’ guaranteed compliance with railway-specific requirements
and standards.
Electrical Components for the Railway Industry
3
Tested and certified in accordance with current standards and directives
Siemens is certified in accordance with IRIS. Our railway components comply with all relevant parts of EN 50155. To prepare for the new CEN/TS 45545, comprehensive verification and documentation is available to you already today.
4
We offer a broad portfolio of reliable and high-quality electrical components for the railway
industry – both for rolling stock and infrastructure applications. For example, the products
from our SIRIUS and SENTRON ranges are permanently employed in countless railway vehicles
around the world. They control, switch and protect air-conditioning systems, windscreen
heaters, underfloor containers, hygiene cabins and many further components. Our SIPLUS
extreme product range also comprises refined controls for extreme application conditions.
Sitet, our trend-setting driver’s cabin terminal, was specifically developed for use in train
cockpits and the corresponding extreme requirements. Furthermore, our SIDOOR automatic
door control represents the optimum solution for the control of interior railway doors.
In the field of infrastructure, our components ensure the fault-free operation of barriers,
signals, sets of points and platform screen doors. Furthermore, SIPLUS RIC facilitates
communication via internationally standardized transfer protocols for telecontrol.
Selected network components from the SCALANCE and RUGGEDCOM product
ranges ensure reliable communication inside the train and along the route –
both wired and wireless. These components are specifically dimensioned
for applications under harsh and critical ambient conditions.
Vehicle control, driver’s cabin 1
Electrical Components for the Railway Industry | Overview
5
Control air-conditioning system 2
Control underfloor container 7
Control exterior door 3
6
Vehicle control control cabinet 9
Control hygiene cabin 8
Control windscreen heater 4 Control
interior door 6Vehicle communication 5
7
Control points
Vehicle communication
Control level crossing
Control signaling system
Vehicle control, driver’s cabin
Control air-conditioning system
Control windscreen heater
Control exterior door
1
2
4
3
Control hygiene cabin
Communication and telecontrol systems for interlockings
Control platform screen doors
Vehicle control control cabinet
Control interior door
Control underfloor container
9
6
7
8
5
Electrical Components for Every Application Area
8
Comprehensive Portfolio of Electrical Components for the Railway Industry
Whether for railway vehicle or infrastructure applications: We offer a comprehensive portfolio of electrical components for countless applications. One of our portfolio highlights: SIRIUS, the complete range for industrial controls. SIRIUS offers everything required for the switching, protection or starting of loads as well as for their monitoring, control, detection, commanding, signaling or supply. Our portfolio is rounded off by numerous products specifically developed and tested for the railway industry.
SIRIUS – 3RV2 motor starter protectors
• Spring-loadedandscrew-typeconnectionsystemonallterminals(alsoringcablelugconnectionuponrequest)
• Forscrewandsnap-onmountingonDINrail• Short-circuitstrengthupto55kA(partially100kA)• TrippingclassS00–S0Class10• Integratedmotorprotectionupto32Aat+70°C• Rated current:• Upto+60°C:100%• Upto+70°C:87%
• Mechanical service life: • Standardversion:100,000switchingcycles• Specialversionsupto–50°C:500switchingcycles
• Comprehensiveaccessories/infeedsystems
SIRIUS – 3RT2 motor contactors up to 18.5 kW
• Spring-loadedandscrew-typeconnectionsystemonallterminals(alsoringcablelugconnectionuponrequest)
• Solenoidcoilwithsuppressordiodeorvaristorcircuit• Forscrewandsnap-onmountingonDINrail• Extendedoperatingrange:0.7–1.25xUs• CommunicationviaIO-Linkwithstationaryapplications• Mounting:• Withseriesresistor/electronicdrive:Withoutclearanceuptoambienttemperaturesof70°C
• Withoutseriesresistor:Side-by-sidemountingwithminimumclearanceof10mmwithambienttemperaturesexceeding60°C
• Contacts:• Withseriesresistor/electronicdrive:Expansionofauxiliaryswitchesanalogoustostandardcontactors
• Withoutseriesresistor:Noattachmentoptionforauxiliaryswitches
SIRIUS – 3RV1 motor starter protectors
• Screw-typeconnectionsystemformaincontacts,spring-loadedconnectionsystemforauxiliarycontacts
• Forscrewandsnap-onmountingonDINrail• Short-circuitstrengthupto100kA• TrippingclassesS2–S3Class10/20• Integratedmotorprotectionupto100Aat+70°C• Rated current:• Upto+60°C:100%• Upto+70°C:87%
• Mechanical service life: • Standardversion:50,000/100,000switchingcycles• Specialversionsupto–50°C:500switchingcycles
• Comprehensiveaccessories/infeedsystems
Electrical Components for the Railway Industry | Overview
9
SIRIUS – 3RT1 motor contactors up to 45 kW with electronic control unit
• Spring-loadedconnectionsystem• Solenoidcoilwithcircuitandelectroniccontrol• Forscrewandsnap-onmountingonDINrail• Extendedoperatingrange:0.7–1.25xUs• Mounting:Withoutclearanceuptoambienttemperaturesof70°C• Contacts:Expansionofauxiliaryswitchesanalogoustostandardcontactors• Coil voltage:• Supportofallconventionalmainvoltagesworldwide:24VDCand110VDC(32VDCand72VDCuponrequest)
• Furthervoltagerangesavailableasseriesresistorversion
SIRIUS – 3RF solid-state switching devices
• Solid-stateswitchingdevicesfortheswitchingof1-and3-phaseresistiveand3-phasemotorizedloads
• Spring-loaded,screw-typeandringcablelugconnectionsystem• Extremelydurable,low-maintenance,ruggedandreliablethankstolongswitchingservicelife
• Wear-andnoise-freeswitching,alsofornoise-sensitiveareas• Expandablefunctionalitybyplug-onfunctionmodules• VibrationresistanceinaccordancewithDINEN61373Category1,ClassB
SIRIUS – 3TB5 motor contactors up to 200 kW
• Withscrew-typeconnectionsystemforscrewmounting• Solenoidcoilwithvaristorcircuit• Extendedoperatingrange:0.7–1.25xUs• ContactorswithDCsolenoidsystem• Minimumbreakingandholdingpower• Version with series resistor:• Mounting:Withoutclearanceupto70°C• Contacts:Non-expandableauxiliaryswitches;twoNOcontactsandoneNCcontactasastandard
SIRIUS – 3TC DC contactors
• 3TC44forscrewandsnap-onmountingonDINrail• 3TC48to3TC78forscrewmounting• Solenoidcoilwithvaristorcircuit• Extendedoperatingrange:0.7–1.25xUs• ContactorsforswitchingofDCvoltagesupto1500V• Version with series resistor:• Mountingwithoutclearanceuptoambienttemperaturesof70°C• Mountingwithaclearanceof10mmwithsize2(3TC44)• Contacts:Non-expandableauxiliaryswitches;twoNOcontactsandoneNCcontactasastandard
10
SIRIUS – 3RH2 contactor relays
• Spring-loadedandscrew-typeconnectionsystemonallterminals(alsoringcablelugconnectionuponrequest)
• Solenoidcoilwithsuppressordiodeorvaristorcircuit• Forscrewandsnap-onmountingonDINrail• Extendedoperatingrange:0.7–1.25xUs• Mounting:• Withseriesresistor:Withoutclearanceuptoambienttemperaturesof70°C• Withoutseriesresistor:Side-by-sidemountingwithminimumclearanceof10mmwithambienttemperaturesexceeding60°C
• Contacts:• Withseriesresistor:Attachmentoptionfor4-poleauxiliaryswitchblockinaccordancewithDINEN50005
• Withoutseriesresistor:Noattachmentoptionforauxiliaryswitches
SIRIUS – 3RH2 latched contactor relays
• Screw-typeconnectionsystem• Solenoidcoilwithvaristorcircuit• Forscrewandsnap-onmountingonDINrail• Extendedoperatingrange:0.7–1.25xUs• Version with series resistor:• Mounting:Withoutclearanceuptoambienttemperaturesof70°C• Contacts:Attachmentoptionfor4-poleauxiliaryswitchblockinaccordancewithDINEN50005
SIRIUS – 3TH4 contactor relays with 8 and 10 contacts
• Screw-typeconnectionsystem• Solenoidcoilwithvaristorcircuit• Forscrewandsnap-onmountingonDINrail• Extendedoperatingrange:0.7–1.25xUs• Mounting:Aclearanceof10mmisrequiredforside-by-sidemountingatambienttemperaturesfrom55°Cto70°C
• Non-expandablecontacts
SIRIUS – 3RP timing relays
• Electronictimingrelays(multifunction)withupto15timeranges• Individualorselectabletimeranges• SwitchpositionandvoltageindicationviaLED
• Withremovableterminalsandwithspring-loadedandalternativescrew-typeconnectionsystem
• Forscrewandsnap-onmountingonDINrail• Comprehensive accessories:• Push-inlugforscrewmounting• Sealedcovercap• Labelsetformultifunctionrelayidentification
Electrical Components for the Railway Industry | SIRIUS
11
SIRIUS – monitoring relays
• Monitoringrelaysforelectricalparameters,thermistormotorprotection,temperature,fillinglevel,speed
• Allversionswithremovableterminalsandwithspring-loadedandalternativescrew-typeconnectionsystem
• Applicabilityinallnetworksthankstowidevoltagerange• Variableadjustability• 3-phasecurrentmonitoringintegratedinthemaincircuit• CommunicationviaIO-Linkwithstationaryapplications
SIRIUS – 3RS / 3TX coupling relays and analog interface converters
• Couplingtechnologywithpower,plug-inandcouplingrelaysinaccordancewiththerailwaystandard
• Couplinglinkswithtwo-tierdesignandconnectionsontwolevels• Versionswithremovableterminalsandwithspring-loadedandalternativescrew-typeconnectionsystem
• Veryslimdesign:6.2mm• Lowpowerconsumption• Applicabilityinallnetworksthankstowidevoltagerange• Versionwithsolid-statecompatibleoutputs(hardgold-plating)• Upto3changeovercontactsinwidthofonly22.5mm
SIRIUS – 3SB3 commanding and signaling devices
• Controlelementsinplasticandmetalversion• Version:Roundandsquarewith16mmor22mmdiameter• Controlelementsincustomer-specificenclosures• Contactblockswithscrew-type,spring-loadedandsolderedconnectionsystem• Flatandergonomicformforoptimumassemblies• Inscriptionwithlasertechnology• IlluminationbasedonLEDtechnology• Rapid“one-manmounting”(actuatorunit+contactblock)withoutspecialtools• Suitableforinstallationincontrolpanelswithathicknessof1to4mmor3to6mm
SIRIUS – 3RK3 modular safety system (MSS)
• Freelyparameterizablemodularsafetyrelay• Realizationofsafety-relatedapplicationsuptoPLeinaccordancewithENISO13849-1orSIL3inaccordancewithIEC62061
• Spacesavingsinthecontrolcabinetandreducedcoststhankstofinelymodularquantitystructure
• Enhancedfunctionalityandtimesavingsthankstosoftware-parameterizablesystem• ImprovedsystemdiagnosticsandincreasedsystemavailabilitythankstodataexchangeviaPROFIBUSandcomprehensiveon-sitediagnostics
• Optionalplug-inconnectionofupto9expansionmodulesforstandardandfail-safeinputs/outputs–optionallywithelectronicorrelay-basedfail-safeoutputs
SIRIUS – 3SE position switches
• Modulardevicedesignwitheasyplug-inconnectionsystem• 4differentenclosureversionsinplasticandmetal• OptionalLEDdisplayforallenclosures• PositiveopeningofNCcontacts• ApplicationareauptoSIL3inaccordancewithIEC62061• Highcontactreliabilityalsowith5VDC/1mA• Safetypositionswitcheswithseparateactuatorwith/withouttumbler• HighdegreeofprotectionuptoIP66/IP67• Extendedtemperaturerange:–40°Cto+85°C• Versionswithincreasedcorrosionprotection
12
5SY6 miniature circuit breakers
• Optionaltoporbottominfeedthankstoidenticalterminals• Comfortableentrythankstolargeandeasilyaccessiblewiringspace• Rapidmanualremovalfromthebusbarassembly• Vibration-andshock-resistantinaccordancewithDINEN61373andDINEN50155“1B”
• Applicabilityatambienttemperaturesfrom–40°Cto+70°C,withmaximumhumidityof95%
• Ratedswitchingcapacity:10ACkA• Vibrationresistance:• InaccordancewithIEC60068-2-6:50m/s²with25to150Hzand60m/s²with35Hz(4sec)
• InaccordancewithEN61373:Category1,ClassB
5SY5 miniature circuit breakers
• Optionaltoporbottominfeedthankstoidenticalterminals• Comfortableentrythankstolargeandeasilyaccessiblewiringspace• Rapidmanualremovalfromthebusbarassembly• Vibration-andshock-resistantinaccordancewithDINEN61373andDINEN50155“1B”
• Applicabilityatambienttemperaturesfrom–40°Cto+70°C,withmaximumhumidityof95%
• Ratedswitchingcapacity:10ACkAand10DCkA• Vibrationresistance:• InaccordancewithIEC60068-2-6:50m/s²with25to150Hzand60m/s²with35Hz(4sec)
• InaccordancewithEN61373:Category1,ClassB
5ST3010 auxiliary switches (AS) for miniature circuit breakers
• 5ST3add-oncomponents:Combinablewith5SYminiaturecircuitbreakersand5SU1RCBOs
• Signalingoftheminiaturecircuitbreaker’scontactpositionbytheauxiliaryswitch(AS)–releasedbyhandorduetofault
• Auxiliaryswitchversionwithtestbuttonfortestingofthecontrolcircuitwithoutswitchingoftheminiaturecircuitbreaker
• Ratedswitchingcapacity:60A• Ambienttemperatures:–5°Cto40°C• Clilmaticwithstandcapability:45°Cwith95%relativehumidity
SENTRON Switching and Protection Devices
Electrical Components for the Railway Industry | SENTRON
Tested switching and protection devices from the SENTRON portfolio ensure reliable low-voltage power distribution in infrastructure and railway applications. The matched components offer outstanding flexibility, comfort and safety for the railway industry.
13
5SU1b RCBOs
• Clear,visibleandcontrollableconnectionofthesupplyline• Comfortableentrythankstolargeandeasilyaccessiblewiringspace• Peakwithstandcurrent(>1kA)forsafeoperation• Retrofittingofadd-oncomponentsforminiaturecircuitbreakersontherightside
• Ratedresidualcurrent:10mA• Ratedcurrent:13mA• Width:2• Forall10kAversionsupto40A:• Fullinsulationthroughintegrated,movableterminalcoversintheareaofconductorentries
• Replacementtimesavingsthankstorapidmanualremovaloftheminiaturecircuitbreakersfromtheassemblywhenchangingtheconnections
3NA3360, 3NA3812 LV HRC fuse links
• Fuselinkswithcombinedindicator:Fusedisconnectionsignaledbycolorchangefromredtowhite
• Insulatedmetalgriplugsembeddedinupperandlowercoverofthefuselinkinplastic–forincreasedsafetyduringreplacement
• Imprintedsignforinsulatedgriplugs• Ratedbreakingcapacity:25DCkA• Ratedcurrent:2to315A• Contactblade:Corrosion-free,silver-plated• Clilmaticwithstandcapability:–20°Cto+50°Cwith95%relativehumidity
3NH3030 LV HRC bases and accessories
• Madeofceramicforscrewmounting• Withflatconnections,screw• Weightperproductunit:0.217kg
SIPLUS – Enhanced Ruggedness, Efficiency and Flexibility for Your Railway Application
SIPLUS S7-300F, S7-300
• Modularcontrollersforthelowtomediumpowerrange• F-modulesalsoforfail-safeapplications• Operatingtemperaturerange:min.0/–25°C,max.+60/+70°C• Relativehumidity:100%r.F.,incl.condensation/frostpermissible• PollutantconcentrationinaccordancewithEN60721-3-3:Class3B2,3C4,3S4• SaltfoginaccordancewithEN60068-2-52:Severitylevel3• Installationaltitude:min.–1000m,max.+2000m(S7-300F)/+5000m(S7-300)• Forrailwayvehicleandinfrastructureapplications
SIPLUS ET 200S
• MultifunctionalandfinelymodularI/OsystemindegreeofprotectionIP20• Operatingtemperaturerange:min.–25/–40°C,max.+60/+70°C• Relativehumidity:100%r.F.,incl.condensation/frostpermissible• PollutantconcentrationinaccordancewithEN60721-3-3:Class3B2,3C4,3S4• SaltfoginaccordancewithEN60068-2-52:Severitylevel3• Installationaltitude:min.–1000m,max.+5000m• Forrailwayvehicleandinfrastructureapplications
Electrical Components for the Railway Industry | SIPLUS | SCALANCE | RUGGEDCOM
15
SIDOOR – automatic door control
• Automaticdoorcontrolofinteriorrailwayandplatformscreendoors• Forrailwayvehicleandinfrastructureapplications• Compactsize(perfectapplicabilityinsubwaystations)• Automaticcalibrationduringcommissioningandcompactsize• 1-buttonoperationforcompletecommissioning• Flexibleexpandabilitybymodularcommunicationinterfaces• Operatingtemperaturerange:min.–20°C,max.+50°C
SIPLUS RIC
• FlexibletelecontrolsystembasedonSIMATICS7• CommunicationviainternationallystandardizedtelecontrolcommunicationprotocolsIEC60780-5-101/103(serial)andIEC60780-5-104(Ethernet)
• ScalabilityofSIMATICET200SuptoS7-400H• ConnectionofSIMATICS7andSIMATICPCS7toSIMATICPCS7telecontrol,WinCCtelecontrol,WinCCOAandthird-partysystems
• Connectionofthird-partydevicestoSIMATICS7andSIMATICPCS7• SIPLUSRICextremealsoforextendedtemperaturerangesfrom–25°Cto+70°C• Tractionpowersupply• Trainair-conditioningcontrolviacontrolstationduringstablingtimes• Faultmanagementforrailwayinfrastructure(tunnelfans,lighting,etc.)
Sitet displays
• Driver’scabterminalforapplicationinrailwayvehicles• Processvisualizationofoperatinganddiagnosticsdataaswellasrouteinformation• Interfacebetweenvehiclecontrolsystemanddriver• Applicationareas:Locomotivedriver’scabins,multiple-unittrains,subwaytrains,rapidsuburbantrains
• CPUx86,upto1.6GHz• WindowsXpemb,Linux,VxWorks• Keyortouchoperation• –40°Cto+70°C• 10.4“or12.1“• MVB,DINbus,Ethernet,RS232,RS422• LEDdisplaybackgroundilluminationwithautomaticbrightnesscontrol• Minimumheatdissipationexpendituresthankstolowpowerloss• Longmaintenanceintervals
16
SCALANCE and RUGGEDCOM – Network Components
Data networks inside and around the vehicle and in trackside infrastructures for harsh and critical ambient conditions
SCALANCE XR324-12M TS / XR324-4M PoE TS
• Modularlymanagedlayer2IndustrialEthernet19”rackswitches• Redundancyfunctionsforhighlyavailableringtopologies,tried-and-testedinindustrialapplications(MRP/HSR),equippedwithadditionalfunctionsfromITapplications,e.g.VLAN,RSTP,MSTP
• SupportofGigabit-Ethernetbyall24ports–SCALANCEXR324-4MadditionallywithPower-over-Ethernet
• Ambienttemperaturesfrom–40°Cto+70°C• Applicabilityunderharshconditionsthankstovibration-proofplug-inconnection• 4or12slotsfor2-portmediamodules–electricaloroptical(multi-modeorsingle-mode)
SCALANCE X308-2M TS
• Partiallymodularlymanagedlayer2IndustrialEthernetswitch• Redundancyfunctionsforhighlyavailableringtopologies,tried-and-testedinindustrialapplications(MRP/HSR),equippedwithadditionalfunctionsfromITapplications,e.g.VLAN,RSTP,MSTP
• SupportofGigabit-Ethernetbyall8ports• Ambienttemperaturesfrom–40°Cto+60°C• Applicabilityunderharshconditionsthankstovibration-proofplug-inconnection• 2orslotsfor2-portmediamodules–electricaloroptical(multi-modeorsingle-mode)
SCALANCE X204-2TS
• Compactlymanagedlayer2IndustrialEthernetswitchwithcomprehensiveredundancyfunctionsforhighlyavailableringtopologies,tried-and-testedinindustrialapplications(MRP/HSR)
• SupportofFast-Ethernetbyall6ports• Applicabilityunderharshconditionsthankstovibration-proofplug-inconnection• Ambienttemperaturesfrom–40°Cto+70°C• 4electricaland2opticalports(multi-mode)
SCALANCE M875
• 3G/UMTSrouterforwirelessconnectionviathemobilecommunicationsnetwork–optimallysuitedforlargebandwidthrequirements,e.g.videotransmission,dataconnectionforticketmachines,infotainmentservices,Internetonboardandtelemetry
• SupportofHSDPAandHSUPA• OptionaldatatransferviaGSMmobilecommunicationsnetworkusingEGPRSandGPRS• IntegratedfirewallandIPsecVPN• Ambienttemperaturesfrom–40°Cto+75°C
17
RX1500 multiservice platform
• RuggedandpowerfulRX1500networkandcomputingplatformwithM12connectionsforcriticalapplications
• Fullymodularlayer2andlayer3IndustrialEthernet19”andrackswitches• Extendedpropertiesfortrafficcontrol(QoS,portratelimiting,broadcaststormfiltering)ornetworksecurity(firewall/VPN)
• AdditionalcomprehensivefunctionsfromITapplications,e.g.VLAN,RSTP,MSTP• ApprovalinaccordancewithNEMATS-2(trafficcontrolequipment)• CompliancewithIEC61850-3&IEEE1613Class2• Supportofupto8GigEportsor16100FXports• Doubleredundantpowersupplyunits• Replaceableandhot-swappablemodules• Ambienttemperaturesfrom–40°Cto+85°C
SCALANCE W786-x RJ45
• Accesspointforoutdoorareas(IP65)withsupportofIEEE802.11a/b/g/nanddataratesofupto450Mbit/secfortheassemblyofabroadbandinfrastructurealongtheroute
• Ruggedimpact-,shock-andvibration-resistantplasticenclosureforhighmechanicalrequirements
• Resistancetosaltfogandsaltspray• RJ45connectionfor10/100/1000Mbit/secwithPoE• SupportofMIMOtechnology(3or6connectionsforexternalantennasor6internalantennas)
• Ambienttemperaturesfrom–40°Cto+60°C• Designedforoutdoorapplications
SCALANCE W788-x M12/RJ45
• AccesspointforcontrolcabinetinstallationorindoorareaswithsupportofIEEE802.11a/b/g/nanddataratesofupto450Mbit/sec
• VersionsinIP30andIP65• Ruggedshock-andvibration-resistantaluminumenclosureforhighmechanicalrequirements
• M12orRJ45connectionsfor10/100/1000Mbit/secwithPoE• Antennaplacementoptimizedfor3x3MIMOtechnology;nointerferencesamongantennaswithdirectmountingondevice
• Ambienttemperaturesfrom–20°Cto+60°C
SCALANCE W784-x
• Accesspointforcontrolcabinetinstallationorinstallationinsuspendedceilings/wallswithsupportofIEEE802.11a/b/g/handdataratesofupto54Mbit/sec
• IP30• Flat,compactshock-andvibration-resistantaluminumenclosureforhighmechanicalrequirements
• RJ45connectionwithretainingcollarfor10/100Mbit/secwithPoE• Ambienttemperaturesfrom–20°Cto+60°C
ANT795-6Mx antennas
Example from our comprehensive antenna portfolio for various application areas:
• Omnidirectionalantennasforverticalradiofieldwith2.4GHzand5GHz• IP65• Antennagain6or8dB• N-ConnectorQMAconnector• Ceiling/wall/roofmounting• Suitabilityformobileunitswithautomatedguidevehicles
Theinformationprovidedinthisbrochurecontainsmerelygeneraldescriptionsorcharacteristicsofperformancewhichinactualcaseofusedonotalwaysapplyasdescribedorwhichmaychangeasaresultoffurtherdevelopmentoftheproducts.Anobligationtoprovidetherespectivecharacteris-ticsshallonlyexistifexpresslyagreedinthetermsofcontract.
AllproductdesignationsmaybetrademarksandproductnamesofSiemensAGorsuppliercompanieswhoseusebythirdpartiesfortheirownpurposescouldviolatetherightsoftheowners-
Subjecttochanges09/12OrderNo.:E20001-A280-P301-X-7600Dispo27600WÜ/42542MI.CE.DA.BRXX.52.2.03WS09125.PrintedinGermany©SiemensAG2012
SiemensAGIndustrySectorIndustryAutomationP.O.Box484890026NUREMBERGGERMANY
Furtherinformationontheproductsdescribedinthisbrochureisavailableviathefollowinglinks:www.siemens.com/siriuswww.siemens.com/sipluswww.siemens.com/sidoorwww.siemens.com/sentronwww.siemens.com/simatic-netwww.siemens.com/ruggedcom