Page 1: electricity ELECTRIC HEATERS - HTT energy GmbH€¦ · ELECTRIC HEATERS example of wte 09 Subject to alterations. / CAUTION: Dimensions may deviate in case of order. 1850 810 2033

01WEFUELEFFICIENCY

ELECTRICHEATERSwte 05 to 23

SPECIFICATIONS

3 – 4 000

21

electricity

+0 – +400

Page 2: electricity ELECTRIC HEATERS - HTT energy GmbH€¦ · ELECTRIC HEATERS example of wte 09 Subject to alterations. / CAUTION: Dimensions may deviate in case of order. 1850 810 2033

type heating capacitiy

compact version

explosion proof design

pump dimensions switchboard dimensions

width depth height width depth height

[kW] [mm] [mm] [mm] [mm] [mm] [mm]

wte 05 3 ‒ 24 optionally optionally integrated 1900 500 1000 50 25 70

wte 07 12 ‒ 36 optionally optionally integrated 1600 800 1800 100 30 76

wte 08 12 ‒ 60 optionally optionally integrated 1600 800 1800 100 30 100

wte 09 40 ‒ 250 optionally optionally separate 2033 810 1400 120 ‒ 160 50 190

ELECTRIC HEATERSexample of wte 09

Subject to alterations. / CAUTION: Dimensions may deviate in case of order.

1850 8102033

600

1200

1400

185 200

100

152

Freiraum 1600

80

Vorlauf

Rücklauf

FIZA 1.7.1TE 1.1.1 TE 1.1.25

1095

flow

return

space

Page 3: electricity ELECTRIC HEATERS - HTT energy GmbH€¦ · ELECTRIC HEATERS example of wte 09 Subject to alterations. / CAUTION: Dimensions may deviate in case of order. 1850 810 2033

type heating capacitiy

compact version

explosion proof design

pump dimensions switchboard dimensions

width depth height width depth height

[kW] [mm] [mm] [mm] [mm] [mm] [mm]

wte 10 240 ‒ 500 optionally optionally separate 2033 845 1670 120 ‒ 180 60 220

ELECTRIC HEATERSwte 10

Subject to alterations. / CAUTION: Dimensions may deviate in case of order.

18508452033

14261200

1670

925

185

600

300

120

152

100

200

1600

VorlaufFIZA 1.7.1

TE 1.1.1 TE 1.1.25

TE 1.1.26

300

flow

space

Page 4: electricity ELECTRIC HEATERS - HTT energy GmbH€¦ · ELECTRIC HEATERS example of wte 09 Subject to alterations. / CAUTION: Dimensions may deviate in case of order. 1850 810 2033

wte 11

type heating capacitiy

compact version

explosion proof design

pump dimensions switchboard dimensions

width depth height width depth height

[kW] [mm] [mm] [mm] [mm] [mm] [mm]

wte 11 440 ‒ 800 optionally optionally separate 2033 845 2320 240 ‒ 300 60 220

2070

2320

1850

157

152

300

120

200

VorlaufTE 1.1.1

TE 1.1.25 TE 1.1.26

300

1095

FIZA 1.7.1

1850 6002033 845

100Freiraum 1600

ELECTRIC HEATERS

flow

space

Subject to alterations. / CAUTION: Dimensions may deviate in case of order.

Page 5: electricity ELECTRIC HEATERS - HTT energy GmbH€¦ · ELECTRIC HEATERS example of wte 09 Subject to alterations. / CAUTION: Dimensions may deviate in case of order. 1850 810 2033

wte 12

type heating capacitiy

compact version

explosion proof design

pump dimensions switchboard dimensions

width depth height width depth height

[kW] [mm] [mm] [mm] [mm] [mm] [mm]

wte 12 680 ‒ 1200 optionally optionally separate 2033 1592 2070 360 ‒ 420 60 220

FIZA 1.7.1

185015922033

2070 1850

157

530

152

300 300 200

120

200

Freiraum 1600

VorlaufTE 1.1.1 TE 1.1.25

1520

300

ELECTRIC HEATERS

space

flow

Subject to alterations. / CAUTION: Dimensions may deviate in case of order.

Page 6: electricity ELECTRIC HEATERS - HTT energy GmbH€¦ · ELECTRIC HEATERS example of wte 09 Subject to alterations. / CAUTION: Dimensions may deviate in case of order. 1850 810 2033

example of wte 13

type heating capacitiy

compact version

explosion proof design

pump dimensions switchboard dimensions

width depth height width depth height

[kW] [mm] [mm] [mm] [mm] [mm] [mm]

wte 13 1000 ‒ 1600 optionally optionally separate 2033 1545 2070 480 ‒ 640 60 220

wte 21 80 ‒ 350 optionally optionally separate

wte 22 80 ‒ 700 optionally optionally separate

wte 23 120 ‒ 1050 optionally optionally separate

starting wte 21, all plants are developed project-specific.

FIZA 1.7.1

1850

2070 1850

15452033

157

1001300

300 300 300 200

120

200

152

Freiraum 1600

Vorlauf

Vorlauf TE 1.1.1 TE 1.1.25

300

1520

ELECTRIC HEATERS

flow

space

flow

Subject to alterations. / CAUTION: Dimensions may deviate in case of order.

Page 7: electricity ELECTRIC HEATERS - HTT energy GmbH€¦ · ELECTRIC HEATERS example of wte 09 Subject to alterations. / CAUTION: Dimensions may deviate in case of order. 1850 810 2033

example of 09 - setup

1 5

2

63

7

Expansion pipe: Expansion pipe to the expansion vessel has to be layed with steady rise of > 3 %

Start-up boil out pipe

Pipe to the safety valve4

8

Overflow pipe (with drain tank): Overflow pipe to the drain tank has to be layed with incline Switchboard

21

7

3 3

4

5

6

8

ELECTRIC HEATERS

Heater inflow

Heater return flow

Drain valve with hose connection

Heat carrier: HT 300

Pressure drop [mFIS]

Inclusive orifice plate [mFIS]

Page 8: electricity ELECTRIC HEATERS - HTT energy GmbH€¦ · ELECTRIC HEATERS example of wte 09 Subject to alterations. / CAUTION: Dimensions may deviate in case of order. 1850 810 2033