electromagnetic plunger with dynamics
TRANSCRIPT
![Page 1: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/1.jpg)
Electromagnetic Plunger with Dynamics k D
![Page 2: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/2.jpg)
Introduction
• Linear plungers/actuators feature in voice coils, electromagnetic relays,
electromagnetic valves etc.
• Main parts are coil, stator core, spring and moving plunger.
• The plunger end is attached to a spring and damper.
• The magnetic core and plunger are modeled with both linear and nonlinear B-H
Curves separately.
• A current pulse is applied to the coil, actuating the plunger.
• The electromagnetic force on the plunger is computed.
• The equations of motion of the plunger are modeled using the Global state variables.
• The model is parameterized to facilitate parametric sweeps.
![Page 3: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/3.jpg)
k D
3D View
Magnetic core
Multi-turn coil
Guider
Plunger/armature
Plunger motion direction
Air region
![Page 4: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/4.jpg)
2D Axi-symmetric View
![Page 5: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/5.jpg)
Modeling Approach
• Geometry dimension: 2D-axisymmetry
• Geometry finalized: using Form Assembly
• Physics used:
1. Magnetic Fields
2. Moving Mesh
3. Global ODEs and DAEs
• Study type: Time Dependent
• Results:
– Electromagnetic force on the plunger vs time
– Dynamic position of the plunger vs time
– Dynamic velocity of the plunger vs time
![Page 6: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/6.jpg)
Model Variables
• A Rectangular waveform is used to model the current in the coil
![Page 7: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/7.jpg)
Magnetic Fields Modeling
• Plunger and Magnetic Core settings when using linear material
• The Magnetic Core and Plunger are modeled using separate ‘Ampere’s Law’ nodes. A linear relationship between B and H is defined using Magnetic Permeability.
• The relative permeability for linear material are: mur_plunger = 4000, and mur_core = 1200.
• Above figures show the setup for plunger and similar settings are applied for the Magnetic Core as well.
![Page 8: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/8.jpg)
Magnetic Fields Modeling
• Plunger and Magnetic Core settings when using nonlinear material
• The non-linearity of Magnetic Core and Plunger is modeled using separate ‘Ampere’s Law’ nodes.
• Above figures show the setup for plunger and similar settings are applied for Magnetic Core as well.
![Page 9: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/9.jpg)
Magnetic Fields Modeling
• Coil settings
• The current in the coil is defined using a rectangular waveform defined in the variables
tab. The number of turns, coil conductivity and coil cross-sections are defined as
shown in the above figure.
![Page 10: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/10.jpg)
• Force Calculation
• Since magnetic materials are used in the
model, the Lorentz method for force
calculation cannot be used as it only
supports the conductive but nonmagnetic
materials.
• Maxwell’s Stress Tensor is used to
compute the forces on the plunger.
• When using Stress Tensor to compute
forces, the mesh around the boundaries
should be very fine to get accurate results.
Magnetic Fields Modeling
![Page 11: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/11.jpg)
Magnetic Fields Modeling
• A continuity boundary condition is added to ensure a continuity between the stationary and moving domains. Weak constraints improves numerical stability.
• The Identity pair is created using ‘Form Assembly’ feature in the Geometry node.
![Page 12: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/12.jpg)
Modeling Plunger Dynamics
• Global ODEs and DAEs interface is used to solve the equation of motion
𝑀𝑑2𝑝
𝑑𝑡2+ 𝐷
𝑑𝑝
𝑑𝑡+ 𝑘𝑝 − 𝐹𝑧 𝑝, 𝑣, 𝑡 = 0
• The above equation can be rewritten into two separate equations as
𝑀𝑑𝑣
𝑑𝑡+ 𝐷𝑣 + 𝑘𝑝 − 𝐹𝑧 𝑝, 𝑣, 𝑡 = 0
𝑑𝑝
𝑑𝑡− 𝑣 = 0
Where, p = z-position v = velocity M = mass D = damping coefficient k = stiffness Fz = electromagnetic force
![Page 13: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/13.jpg)
Moving Mesh Settings
• Since COMSOL 5.3a, the “Moving Mesh” node is to be found under “Definitions”
• Moving Mesh interface is used to model the ‘Translational Motion’ of the plunger.
• The ‘Fixed Boundary’ and ‘Prescribed Mesh Displacements’ are defined as shown in the figure.
• The displacement of Plunger is given by position variable ‘p’ obtained from ‘Global ODEs and DAEs’ interface.
• Same method as in example:
• https://www.comsol.com/model/voltage-induced-in-a-coil-by-a-moving-magnet-14163
Moving Mesh physics is only solved in the moving domains.
Fixed boundary
Fixed boundary
![Page 14: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/14.jpg)
Mesh Settings
• The Destination boundary from the Identity pair should be finer than the Source
boundary to properly map resolve the continuity between moving and
stationary parts.
• Mapped mesh is used in the moving domains (excluding Plunger).
![Page 15: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/15.jpg)
Mesh Settings
• A very fine mesh is generated along the boundaries of the Plunger in order to
accurately measure the forces using Maxwell’s Stress Tensor.
• Boundary layers are defined on Plunger and Magnetic Core to properly resolve the
induced eddy currents.
![Page 16: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/16.jpg)
• For fast and robust computation, use
linear elements by changing the
Discretization to Linear. This is strongly
recommended when having nonlinear
materials (B-H curve). The reason being
that the spatial transition from
magnetically unsaturated to saturated
regions is often not resolved by the
mesh. That is handled better by linear
elements whereas higher order
elements can develop
numerical instabilities.
Changing Discretization
![Page 17: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/17.jpg)
Solver settings
• For physics involving moving mesh, applying some manual solver tuning
is recommended.
• Time-Dependent Solver
– Time stepping and Error estimation
• Fully Coupled
– Nonlinear Solver settings
• Direct Solver
– Pardiso is usually faster than MUMPS
![Page 18: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/18.jpg)
• Exclude algebraic states in the error
estimation. The Lagrange multipliers in
weak constraints are algebraic and
noisy. Other algebraic variables may
arise in circuit couplings.
Time-Dependent Solver
![Page 19: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/19.jpg)
• Frequent Jacobian update is required
due to the motion (couplings change).
• Increase the Maximum number of
iterations and tightening the
Tolerance Factor.
• Try using Anderson acceleration.
Fully Coupled
![Page 20: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/20.jpg)
• PARDISO is usually faster than MUMPS
Direct SOlver
![Page 21: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/21.jpg)
Figure: Magnetic flux density in the plunger at t=0.2011 s.
Results: Magnetic Flux Density
![Page 22: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/22.jpg)
Results: Electromagnetic Force
Figure: The electromagnetic force acting on the plunger depending on the current in the coil for different ‘Damping
Coefficients’.
![Page 23: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/23.jpg)
Results: Plunger Position
Figure: The change in the position of the plunger as the current varies in the coil for different ‘Damping Coefficients’.
![Page 24: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/24.jpg)
Results: Plunger Velocity
Figure: The velocity profile of the plunger w.r.t time as the current varies in the coil for different ‘Damping Coefficients’.
![Page 25: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/25.jpg)
Induced Current
NOTE: You need to click on “Slide Show” mode to visualize the animation.
![Page 26: Electromagnetic Plunger with Dynamics](https://reader030.vdocument.in/reader030/viewer/2022012721/61b3d42c66764e7b8279852a/html5/thumbnails/26.jpg)
Plunger Dynamics
NOTE: You need to click on “Slide Show” mode to visualize the animation.