electronic load pli - caltest instruments ltd · 2020. 2. 19. · optionally (option pli20) the...

5
Electronic Load PLI Now with CP mode and MPPT functionality

Upload: others

Post on 19-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Electronic Load PLI - Caltest Instruments Ltd · 2020. 2. 19. · Optionally (Option PLI20) the MPPT Function can be enabled. MPPT: Maximum Power Point Tracking Loading capacity The

Electronic Load PLI

Now with CP mode and MPPT functionality

Page 2: Electronic Load PLI - Caltest Instruments Ltd · 2020. 2. 19. · Optionally (Option PLI20) the MPPT Function can be enabled. MPPT: Maximum Power Point Tracking Loading capacity The

2

Electronic Load PLI

Electronic Loads, PLI Series

Description

The Electronic Loads of PLI

series provide a comfortable

operation by a graphical user

interface.

The highlight of the PLI series

is the extensive variety of

standard interfaces.

Apart from Ethernet, USB, RS-

232 and Analog I/O Port there is

a standard CAN interface.

GPIB can be installed as an

option (PLI02).

Programming is done in SCPI

syntax.

Functions

The units provide constant

current, constant voltage,

constant resistance and con-

stant power mode. Optionally

MPPT1) function for solar

panel test can be activated. In

addition, protections for cur-

rent and voltage can be set in

any mode. Dynamic operation

can be configured by up to 300

list point settings. A data ac-

quisition function allows to

store measurement data on an

external USB flash drive.

Optionally (Option PLI20) the

MPPT Function can be enabled.

Loading capacity

The model range covers three

power classes with 600 W,

1,400 W, 2,100 W and 3,200

W continuous power rating.

In addition the models up to

300 V have an overload capa-

bility. The height and duration

of the possible overload de-

pends on the temperature of

the power stage. The unit

indicates the currently possible

overload. Therefore the units

can be used even for consider-

ably more powerful applica-

tions for short time.

Protections

Current limitation

Power limitation

Over-temperature protec-tion

Over-voltage protection

Reverse polarity protec-tion up to rated current

Under-voltage indicator

Protection of the GND lines at the Analog I/O Port

Tools

The delivery includes comforta-

ble tools for PC control.

1) MPPT: Maximum Power Point Tracking

Interface overview

RS-232 X

USB X

LAN X

GPIB O

CAN X

Analog X

Analog isolated O X Standard O Option /not available

Analog I/O Port

The standard Analog I/O Port

provides the following func-

tions:

Load setting C and V

Analog setting of C and V protections

Load on-off

Voltage monitor output

Current monitor output

Trigger input

Trigger output

Digital input and pro-grammable output

Galvanically isolated

Analog I/O Port

(Option PLI06)

For the galvanic isolation be-

tween the Analog I/O Port and

the load terminals the PLI06

option can be installed.

Using this board prevents

ground loops and allows load-

ing of bipolar voltages with

two loads and common analog

control.

Data Interfaces

The following interfaces are

included as standard:

Ethernet

USB

RS-232

CAN

Analog I/O Port

LabVIEW driver is approved by

National Instruments.

Factory Calibration

Certificate

(Option FCC-PLIxx)

A Factory Calibration Certificate

(FCC) can be supplied with the

devices. The FCC meets the

requirements according to DIN

EN ISO 9000ff. This calibration

certificate documents the trace-

ability to national standards to

illustrate the physical device in

accordance with the inter-

national System of Units (SI).

The recommended calibration

interval is 1 year.

Ethernet + USB + RS-232 + CAN + Analog I/O Port

as standard

CC - CV - CR - CP - CCV - CVC Mode + optional MPPT

Dynamic loads with synchronized DAQ function

SCPI programming with measurement function

USB stick as measurement data memory

Protections for current and voltage

Depending on model, temporary overload capacity

High power density up to 3,200 W in 3HU

Full electronic protection

Silent fan cooling

Digital input and programmable control output

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

Page 3: Electronic Load PLI - Caltest Instruments Ltd · 2020. 2. 19. · Optionally (Option PLI20) the MPPT Function can be enabled. MPPT: Maximum Power Point Tracking Loading capacity The

3

Electronic Load PLI

Model

(order

number)

Conti-

nuous

power

Short-time

power 1)

Volta-

ge

Cur-

rent

Rise/fall

time 2)

Resistance Housing 3) Noise

max. 4)

Load connection 5)

front back

PLI606 600 W 1,200 W 60 V 60 A 50 µs 0.033 ... 10.8 Ω ½19”, 2 HU 55 dB(A) PK 4-60 FK 8

PLI606 C10 600 W 600 W 60 V 10 A 30 µs 0.2 ... 64.5 Ω ½19”, 2 HU 55 dB(A) PK 4-30 PK 4-30

PLI612 600 W 1,200 W 120 V 20 A 50 µs 0.100 ... 64.5 Ω ½19”, 2 HU 55 dB(A) PK 4-30 PK 4-30

PLI630 600 W 900 W 300 V 16 A 40 µs 0.125 ... 202 Ω ½19” ,2 HU 55 dB(A) PK 4-30 PK 4-30

PLI660 600 W 600 W 600 V 8 A 40 µs 0.25 ... 807 Ω ½19”, 2 HU 55 dB(A) PK 4-30 PK 4-30

PLI680 600 W 600 W 800 V 6 A 40 µs 0.33 ... 1 430 Ω ½19”, 2 HU 55 dB(A) PK 4-30 PK 4-30

PLI1406 1,400 W 2,800 W 60 V 120 A 50 µs 0.017 ... 5.37 Ω 19”, 2 HU 56 dB(A) - FK 8

PLI1406 C20 1,200 W 1,200 W 60 V 20 A 30 µs 0.1 ... 32.2 Ω 19”, 2 HU 56 dB(A) - PK 4-30

PLI1412 1,400 W 2,800 W 120 V 40 A 50 µs 0.05 ... 32.3 Ω 19”, 2 HU 56 dB(A) - PK 4-60

PLI1430 1,400 W 2,100 W 300 V 32 A 40 µs 0.063 ... 101 Ω 19”, 2 HU 56 dB(A) - PK 4-60

PLI1460 1,400 W 1,400 W 600 V 16 A 40 µs 0.125 ... 403 Ω 19”, 2 HU 56 dB(A) - PK 4-30

PLI1480 1,400 W 1,400 W 800 V 12 A 40 µs 0.167 ... 717 Ω 19”, 2 HU 56 dB(A) - PK 4-30

PLI2106 2,100 W 4,200 W 60 V 180 A 50 µs 0.011 ... 3.58 Ω 19”, 2 HU 60 dB(A) - FK 8

PLI2106 C30 1,800 W 1,800 W 60 V 30 A 30 µs 0.066 ... 21.5 Ω 19”, 2 HU 60 dB(A) - PK 4-30

PLI2112 2,100 W 4,200 W 120 V 60 A 50 µs 0.033 ... 21.5 Ω 19”, 2 HU 60 dB(A) - PK 4-60

PLI2130 2,100 W 3,150 W 300 V 48 A 40 µs 0.042 ... 67.2 Ω 19”, 2 HU 60 dB(A) - PK 4-60

PLI2160 2,100 W 2,100 W 600 V 24 A 40 µs 0.083 ... 269 Ω 19”, 2 HU 60 dB(A) - PK 4-30

PLI2180 2,100 W 2,100 W 800 V 18 A 40 µs 0.111 ... 478 Ω 19”, 2 HU 60 dB(A) - PK 4-30

PLI3206 3,200 W 6,400 W 60 V 300 A 60 µs 0.007 ... 2.15 Ω 19”, 3 HU 70 dB(A) - FK 25

PLI3212 3,200 W 6,400 W 120 V 150 A 60 µs 0.013 ... 8.60 Ω 19”, 3 HU 70 dB(A) - FK 25

PLI3230 3,200 W 4,800 W 300 V 60 A 60 µs 0.033 ... 53.7 Ω 19”, 3 HU 70 dB(A) - PK 4-60

PLI3260 3,200 W 3,200 W 600 V 40 A 60 µs 0.05 ... 161 Ω 19”, 3 HU 70 dB(A) - PK 4-60

PLI3280 3,200 W 3,200 W 800 V 30 A 60 µs 0.067 ... 286 Ω 19”, 3 HU 70 dB(A) - PK 4-30

1) The possible short-time power depends on the temperature of the output stage, i.e. on the previous load.

2) Rise and fall times are defined from 10 ... 90 % and 90 ... 10 % of the maxi-mum current in “fast” setting. (Const. current mode, tolerance +/- 20 %). Risetimes in the settings “medium”: 500µs, “slow”: 5ms

3) 1 HU = 1 height unit = 44.45 mm 4) Measured on the front from distance of

1m 5) PK 4-30: Pole terminal touch-protected

for 4 mm laboratory jack + stripped wires, max. 30 A. PK 4-60: Pole terminal touch-protected

for 4 mm laboratory jacks + stripped wires, max. 60 A. FK 8: Flat copper rail with M8 screw FK 25: Flat copper rail with M10 screw

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

Page 4: Electronic Load PLI - Caltest Instruments Ltd · 2020. 2. 19. · Optionally (Option PLI20) the MPPT Function can be enabled. MPPT: Maximum Power Point Tracking Loading capacity The

4

Electronic Load PLI

Technical Data PLI Series

Subject to technical modifications

Analog I/O Port

Analog control inputs 0 ... 10 V

of the setting value of the corresponding range

Current ±0.2 % ±0.1 %

Voltage ±0.2 % ±0.1 %

Current protection ±1 % ±0.4 %

Voltage protection ±1 % ±0.4 %

Input resistance of analog inputs >10 kΩ

GND max. ±2 V with respect to negative load input

Analog measurement outputs 0 ... 10 V

of analog signal of offset voltage

Voltage ±0.2 % ±15 mV

Current ±0.2 % ±15 mV

Load capacity: minimal 2 kΩ

Control inputs and outputs

Control outputs

Output level

input on/off

overload trigger output

programmable output

selectable, 3.3 V, 5 V, 12 V,

or external programmable up to 30 V

Control inputs

Input level

input on/off

mode selection trigger input

digital input

3 V to 30 V

Operating conditions

Operating temperature 5 °C ... 40 °C

Cooling 3-stage air-cooling

Supply voltage

Power consumption

115/230 V~ ±10 %, switchable 50 ... 60 Hz

PLI6XX PLI14XX PLI21XX PLI32XX

35 VA 55 VA 75 VA 150 VA

Dimensions

W x B x D 1) (mm) Weight

PLI6XX PLI14XX PLI21XX PL32XX 222 x 88 x 555 — 444 x 88 x 520 — 444 x 133 x 540

9 kg 15 kg 17,5 kg 22,5 kg

Color

Front panel, side panels top

RAL7032 (pebble grey) RAL7037 (stone grey)

Electrical safety

DIN EN 61010

EMC, CE marking DIN EN 61326-1

DIN EN 61000-3-2 DIN EN 61000-3-3

Warranty 2 years

Available options

19” rack mounting kits for models order number

1 PLI6XX PLI10 2 PLI6XX PLI11

PL14IXX or PLI21XX PLI12

PLI32XX PLI13

MPPT Function PLI20

GPIB Interface PLI02

Settings

of the setting value of the corresponding range

Current ±0.2 % ±0.05 %

Voltage ±0.2 % ±0.05 %

Resistance (at 5 % to 100 % of the voltage range)

±1.4 %

±0.3 % of current range

Power (at U and I 10-30% of the Range) (at U and I >30% of the range)

±1,4%

±0,7%

Resolution 14 bit

Limitations

Current ±1.4 % ±0.3 %

Voltage ±1.4 % ±0.3 %

Measurement / Display

of the measured

value (actual value)

of the corresponding range

Voltage ±0.2 % ±0.05 % ±1 digit

Current ±0.2 % ±0.05 % ±1 digit

Resistance is calculated from current and voltage

Power is calculated from current and voltage

Resolution 18 bit / 13 bit at DAQ function

Dynamic Function

No. of load levels max. 300, with ramp time and dwell time setting

min. max.

Dwell time 100 µs 400,000 s

Resolution 100 µs

+/-0.02% Precision of the setting times

Data Acquisition

To external USB flash drive

Measurement rate 0.5 s, 1 s, 5 s, 10 s

Measurement data time stamp, voltage, current

File format .CSV format

Into internal memory

Measurement rate 100 µs … 400,000 s, resolution 100 µs,

synchronized witch Dynamic Function

Measurement data time stamp, voltage, current

No. of points max. 8,000

Input

Input resistance >50 kΩ when load input is off

Input capacity approx. 2 µF / 600 W

Parallel operation up to 5 units in Master-Slave mode

(hardware-controlled)

Input voltage see type overview

Minimum voltage

min. 1.4 V for max. current,

including linear derating of current with respect to 0V

Permissible

operating voltage

negative load input - housing

125 V DC

Protective devices over-voltage up to 105 % of rated voltage

over-current over-power

over-temperature

reverse polarity up to rated current

under-voltage display (if the input voltage is too low for the set voltage)

Connections Load input: Sense:

see type overview PK 4-30 (Pole terminal touch-protected for 4 mm laboratory jack + stripped wires)

Continuous power see type overview (where TA = 21 °C)

Derating -1.2 %/°C for TA > 21 °C

Overload capability see model overview

Hoecherl & Hackl GmbH

Industriestr. 13

94357 Konzell

Germany

Tel.: +49 9963/94301- 0

Fax: +49 9963/94301-84

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI

PLI E 04/15

1) This is the deepest device type of the series.

Page 5: Electronic Load PLI - Caltest Instruments Ltd · 2020. 2. 19. · Optionally (Option PLI20) the MPPT Function can be enabled. MPPT: Maximum Power Point Tracking Loading capacity The

Available from

Power sources and test instrumentation solutionsCaltest have been providing power sources and test instrumentation solutions for over 20 years and are proud to represent a number of industry leading manufacturers.

As well as supplying world class power sources and test instrumentation Caltest also has a service centre and UKAS calibration laboratory.

Caltest Instruments Ltd 4 Riverside Business Centre Walnut Tree Close Guildford Surrey GU1 4UG United Kingdom

NEED HELP?

CALL US: 01483 302 700

or visit our website for more details

Tel: +44 (0) 1483 302 700

Fax: +44 (0) 1483 300 562

[email protected]

www.caltest.co.uk

Sales • Rentals • Service • UKAS Calibration