elitery building facilities in bogor
DESCRIPTION
Elitery is the first TIER III Certified data center in South East Asia, currently we have 118 clients, more than 85% are in financial industry.TRANSCRIPT
Building & Facilities Presentation
Presented by Hendra Suryakusuma
A B O U T E L I T E R Y D A T A C E N T E R
At A Glance
Elitery is the first Tier III certified Data Center facility in South East Asia located in Bogor with the most reliable state-of-the-art infrastructure.
A B O U T E L I T E R Y D A T A C E N T E R
Vision & Mission
Our Vision
To become the best World Class neutral data center operator.
Our Mission
Building international standard data center & DRC facilities and operating it in the most professional way. And it has to meet these criteria : Secure, Reliable & Robust, Green, Network Neutral, and Transparent and Service Excellence.
Our Building & FacilitiesEstablishing a safe haven for your data is the ultimate priority for us.
We apply best practices to select the best location for our data center.
You can rest assured that your business is well-protected
because we put your invaluable data assets in a strategic and safeguarded place.
Building Front View From Pajajaran Street
• Located in Bogor, a quick 45 minutes drive from
Jakarta CBD Only 10 minutes from Bogor Toll Exit
• Fire Department and Police Station are within 1
km distance
• Convenience stores are available nearby
Main Benefits
B U I L D I N G & FA C I L I T I E S
Your Data Safe Haven
• Located 200 meter above the sea level, in flood free area.
• Strategically located in 42 km south of Jakarta, ideal for DRC site.
• Easy access to Jagorawi Toll Road connecting to Jakarta Inner and
outer ring Road.
Main BenefitsB U I L D I N G & FA C I L I T I E S
With access to all major Network
Provider (Indosat, Telkom, Icon+, LinkNet dan
Lintas Arta).
Elitery is proud to be a Telco-Friendly Facility.
Main Benefits
Access to Major Network ProvidersB U I L D I N G & FA C I L I T I E S
The interconnection between your Head Office and
Branch Offices for your mission-critical application is
no more than just a patch away. On top of that, the
fiber connection also features dual-path
redundancy to minimize risk with two separate
distribution channel. We can ensure you that we
use the right and best network available to make
your data highly accessible.
Main Benefits
Best Network AvailableB U I L D I N G & FA C I L I T I E S
We use the gas supply from
PGN (government owned gas
company) for our chiller engine.
ContinuousGas Supply
BUILDING & FACILITIES
ElectricitySupply
Electricity supplied by two
different substations, from two
different power plants
BUILDING & FACILITIES
Steel Gate
Strong steel gate, 3-shift
security personnel, and 24
hours surveillance cameras
ensure the
building & facilities security.
BUILDING & FACILITIES
Convenient FacilitiesB U I L D I N G & FA C I L I T I E S
Meeting Room, 1st Floor Reception Area & Staging Room Engineers Bedroom, 6th Floor
Parking Lot & Diesel Tank
Secure parking lot is available
both for car and motorcycle.
The onsite Diesel Tank support
up to 14 days (216.000 liters).
BUILDING & FACILITIES
Water Cooling SystemB U I L D I N G & FA C I L I T I E S
Make Up Water Tank Area Water Pumps, Basement Floor
Cooling Tower& Pipes
BUILDING & FACILITIES
Our Data Center uses state-of-
the art Environmental System
Technology which provides high
environment stability required to
run mission-critical operation.
Water Cooling SystemB U I L D I N G & FA C I L I T I E S
Cool Water Tower (N+1) Chiller Engine (N+1)
Building ManagementSystem
BUILDING & FACILITIES
We use the most capable and
scalable building management
system. It provides the essential
instrumentation and control we
need to coordinate, regulate and
manage our building systems.
Automatic Transfer Switch
BUILDING & FACILITIES
We use the best ATS panel available to
guarantee reliable, seamless power
when outages occur. They
automatically transfer power to the
generator when utility power fails,
providing the highest protection for
continuous power.
Power Outage Protection B U I L D I N G & FA C I L I T I E S
UPS Battery UPS N+1
Double Genset By Perkins
BUILDING & FACILITIES
To ensure the best power
generation when blackout
occurs, we use 2 Perkins genset,
each could generates 1,5 Mw of
electricity power.
Waterless Fire Suppression System By DuPont FM-200 ®
B U I L D I N G & FA C I L I T I E S
DuPont™ FM-200® is accepted and respected worldwide, with a history of protecting some of the world's most critical and irreplaceable assets. In fact, FM-200® is in use in over one hundred thousand applications, in more than 70 nations.
Building SpecB U I L D I N G & FA C I L I T I E S
• Gross Area: 5000m2 (50,000 ft2)• Building Management System• Concurrently Maintainable Building• Multiple Separated M&E Rooms with redundant AHU units• Dual Redundancy Chill Water Chillers System• Dual Redundancy Cooling Tower System• Dual Redundancy Pump System• Special Design Diesel Generators Room• 216,000 Liters Diesel Tanks• 100,000 Liters makeup Water Tanks• 100,000 Liters Hydrant Water Tanks• 100,000 Liters Ground Water Tanks
Structure:• Reinforce Concrete Structure building with Fire resistance walls• Earthquake Resistance Building up to 8.5 RS• 5.0 m slab to slab height• Column spacing primarily based on 7 & 8.5m grid• Bomb, Bullet & Quake resistance windows• Dual Separated & compartmented Risers• Passenger/Cargo Lift 1x1.6 tones• Positive Air Intake Building
Data Center SpecB U I L D I N G & FA C I L I T I E S
• Gross Area: 1,320m2 (13,200 ft2)• Gross Raise Floor: 1,140m2 (11,400 ft2)
Structure:• Data Center floor loading of 1 tone• Reinforced Concrete Floor with Fire & Water Resistance Floor• 5 meters slabs to slabs Height Flooring• 0.8 meter high 1 ton Raised floor with anti static tiles• Dual Feed Chilled water pipe on ring topology Under Raised Floor• Dual Feed Zonings Power Distribution System Under Raised Floor• Pre Action FM 200 Above & Under Raised Floor• Smoke, Heat & water Detection system above & Under Raised• Trap man Door applied• Redundant Duel Coil CRAC Parameter Cooling• Separated Utility from Datacenter Floor• State of the art Access Door System• State of the art CCTV & Surveillance System
Give Us A Shout!