email quality red phase presentation · 820 ct test bridge reference cts cvt testing 590k cvt...

31

Upload: others

Post on 29-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES
Page 2: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

MISSION:

Provide innovative and reliable testing

solutions to the electrical industry.

Build strong bonds with our customers and

listen to their needs so that using continuous

improvement methods we can achieve total

satisfaction.

Page 3: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

FOUNDED in Melbourne, in 1976 by Richard

Dowling (CEO) to supply the local Victoria state utility

with instruments.

GREW to deliver to the whole Australian market.

EXPANDED to satisfy global markets. (80%

of the production is now sold overseas)

Page 4: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

COUNTRIES THAT WE SUPPLIED

SOLUTIONS TO

Page 5: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

COMPANY STRUCTURE

CEO

TechnicalMngr.

Operations Mngr.

Sales Mngr.Financial/Admin.

Mngr.

REDPHASE is a medium sized company with over 20 employees.

This size and structure give us the advantage of a great flexibility not

found on any other competitor in the market.

We are able to easily double our actual production capacity without

mayor investments of capital or time.

Service & Calibrations

R&DQuality Control

ProductionPersonnel

PurchasesWarehouse Personnel

Local SalesInternational Sales

Accountability

Accounts Payables &

Administration

Page 6: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

HIGH POWER

EARTH TESTING

METER TESTING

INSTRUMENT

TRANSFORMER

TESTING

P.D. TESTING

Page 7: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

INSTRUMENT TRANSFOMER TESTING

Page 8: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

CT testing :

590G-V2 CT Tester

590F Live CT Tester

661 Protection CT Tester

PT (VT) testing

590D-1 PT Full Load Tester

INSTRUMENT TRANSFOMER TESTING

661 Protection CT Tester

505B Admittance Tester

594 CT Batch Tester

820 CT Test Bridge

Reference CTs

CVT testing

590K CVT Tester

Burden testing

704 CT Burden Tester

Page 9: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

590G-V2 CT ERROR TESTER

KEY FEATURES•Small & Lightweight (7 Kg), yet tough and durable - Perfect for field

testing and convenient for the workshop.

•Automatic, fast & fool-proof testing - Reduce testing times and personnel

thus lower testing costs.

•Customize your tests - Not only you can use the pre recorded standard

tests, but you can also program 590G-V2 to make your own custom made tests, but you can also program 590G-V2 to make your own custom made

tests.

•Safe testing - Simulation method allows testing at lower voltage levels

increasing safety.

•Up to 0.1 Class CT testing - High accuracy allows testing up to 0.1 class

CTs.

•Built in thermal printer - For on-site results printing (Optional).

•Big 6” screen - Easily see the results in any light condition.

•Inbuilt memory - Store up to 300 test results and download them to your

computer.

•Four terminal test leads - for superior testing accuracy.

•Automatic CT demagnetizing after testing .

Page 10: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

TEST CAPABILITIES

CT ratio and phase error measurements. (Analyses if CT complies with regulations)

CT 1.6 kHz Admittance test. (Helps to determine if CT is faulty i.e. a shorted turn)

CT excitation curve & knee point test. (Traditional CT test)

Burden Test. (Helps to check if the burden connected to the CT is higher than its

590G-V2 CT ERROR TESTER

Burden Test. (Helps to check if the burden connected to the CT is higher than its

rated burden)

CT winding resistance measurements

CT polarity measurements

CT live testing (With 590F accessory)

PT full load simulated tests (In combination with model 590D)

TESTING STANDARDS

Customizable to any requirement, including:

IEC 60044 Instrument Transformers

IEEE C57.13-1993 Requirements for Instrument Transformers

Page 11: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

CT ERROR TEST

• Most important test.

• Utilities around world concentrating in this test.

• Checks If CT accuracy is within limits.

• Direct effect on revenue.

• Governmental Regulations to do periodical checks.

• 99.5% of CT accuracy depends on turns ratio.

• 0.5% depends on 50/60 Hz. Admittance.

TEST RESULTS

% of

rated VA

% of Primary Current

120% 100% 50% 10% 5%

Ratio Error 100% +0.023% +0.017% -0.032% -0.078% -0.134%

Phase Displacement 100% +3.6' +3.8' +3.7' +4.5' +6.6'

Ratio Error 25% +0.178% +0.152% +0.108% -0.006% -0.083%

Phase Displacement 25% +2.4' +2.8' +3.2' +4.2' +5.1'

Page 12: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

1.6kHz ADMITTANCE TEST

• Similar to 50 or 60 Hz admittance.

• Inherent error of the CT.

• Blueprint of a CT.

• Used for future reference.

• Fast test, easy to see if shorted turn or tampering.

• Compared with same CT past value or same model

averages.

• Can be done Live with every Meter test and model 505B

BURDEN TEST

• Design of the metering circuits different than reality.

• Connections in the measuring circuit can become loose.

• Important to check if the burden connected to the CT is

lower than the rated burden.

Page 13: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

PT (VT) FULL LOAD TEST

590G-V2 + 590D1

•Full load inductive PT error test.

•Up to 0.1% accuracy

LIVE RATIO TEST

590G-V2 + 590F

•On-line ratio check

•No need to cut supply

•Easily check CT ratio•Easily check CT ratio

•HV & LV kits

•Uses customer Load

•100 m fiber optic cable for inaccessible areas

Page 14: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

590G-V2 CT ERROR TESTER

CONNECTIONS

CT testing connection

Burden testing connection

Live CT testing connection

Page 15: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

590K CVT TESTER

KEY FEATURES•Small & Lightweight (12 Kg), yet tough and durable - Perfect for field

testing and convenient for the workshop.

•Automatic, fast & fool-proof testing - Reduce testing times and personnel

thus lower testing costs.

•Customize your tests - Not only you can use the pre recorded standard

tests, but you can also program 590K to make your own custom made tests. tests, but you can also program 590K to make your own custom made tests.

•Safe testing - Simulation method allows testing at lower voltage levels

increasing safety.

•Up to 0.2 Class CVT testing - High accuracy allows testing up to 0.2 class

CVTs.

•Big 6.4” screen - Easily see the results in any light condition.

•Inbuilt memory - Store up to 2GB test results and download them to your

computer.

•PC104 Module Board – Runs Windows NT, thus Easy to operate, update

and add extra features

Page 16: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

TEST CAPABILITIES

CVT ratio and phase error measurements

Burden Test. (Helps to check if the burden connected to

the CVT is higher than its rated burden)

CVT DC winding resistance measurements

590K CVT TESTER

CVT DC winding resistance measurements

CVT LV VP/VA transfer ratio test

CVT core admittance test

CVT Input impedance test

CVT C1 & C2 value test

TESTING STANDARDS

Customizable to any requirement, including:

IEC 60044 Instrument Transformers

IEEE C57.13-1993 Requirements for Instrument Transformers

Page 17: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

INSTRUMENT TRANSFOMER TESTING

661 PROTECTION CT TESTER

•Up to 20 times overload characteristics

•CT ratio measurement

•Burden Test•Burden Test

505B CT ADMITTANCE TESTER

•Performs 1.6kHz Admittance test Live

•Live burden measurement

•Only 10 extra minutes to Meter test

Page 18: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

INSTRUMENT TRANSFOMER TESTING

704

HANDHELD

CT BURDEN

594 CT

BATCH CT BURDEN

TESTER

820 CT

TEST

BRIDGE

REFERENCE

CT

TESTER

Page 19: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

HIGH POWER EARTH TESTING

Page 20: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

8000S HIGH POWER EARTH TESTING SYSTEM

KEY FEATURES•Small & Lighter than conventional methods, yet tough and durable.

•Immune to system noise – Selectable testing frequency and precise filters

eliminate noise and interference concerns.

•Live testing – Test can be made with the substation in service.

•Easier testing - No network reconfiguration or protection equipment

alterations required. alterations required.

•Safer testing – Lower current values increases tests safety.

•Faster testing- Reduce testing times and costs to about 50% of high current

methods.

•Inbuilt memory – Frequency selective multimeters store up to 7000

records which can be later downloaded by USB to a computer.

•High accuracy – Measure complex impedances accurately and repetitively.

Page 21: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

TEST CAPABILITIES

Earth Impedance

Earth grid voltage rise

Current Flow

Step and Touch voltages

8000S HIGH POWER EARTH TESTING SYSTEM

Step and Touch voltages

Surface Potential Distribution

Soil resistivity

Earth Continuity

TESTING STANDARDS

Red Phase Instruments 8000S system, can be used to perform measurements

included in International standards such as: IEEE 80-2000; IEEE 81-1983; DIN

VDE 0101; CENELEC HD637S1.

Page 22: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

SYSTEM COMPOSITION

MODEL 4024

INJECTION UNIT

•Switch mode voltage source

•Generates stable signals at

selected freq.

•Currents at freq. between 45 %

65 Hz.

MODEL 4025D

FREQUENCY

SELECTIVE

MULTIMETER

•Measures magnitude and phase

angle of signals in selected freq.

•Freq. range: 40 to 69 Hz.65 Hz.

•Connected to 4023 to increase

the current signal.

MODEL 4023

COUPLING

TRANSFORMER

•1500VA load maximum power

output.

•Driven by 4024 connected to the

primary.

•Selector switch to match current

loop impedance.

•Freq. range: 40 to 69 Hz.

•High quality filters.

•Internal rechargeable batteries.

•Rogowski or LEM current inputs.

MODEL 4022B

EARTH CONTINUITY

TESTER

•Checks continuity of connections

within earth system.

•Main unit connects to earth.

•Remote unit probe gives also

resistance reading.

•100m extension to test large areas.

Page 23: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

EARTH IMPEDANCE TEST

• Directly refers to voltage rises in systems under

fault.

• “Off frequency” current is injected to the earth

grid.

• Use of independent cable and stake or out of • Use of independent cable and stake or out of

service overhead line.

• Linear Method C Current stake)=5D.

• Reference potential P≈0.62C

• Choose a current frequency near the line

frequency.

• Select that current with the Freq. Selective

Multimeter.

• The impedance is automatically calculated.

• For more accurate results use frequency

interpolation.

• Other arrays (perpendicular, angle, etc.)

Page 24: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

STEP & TOUCH VOLTAGES

• Under fault conditions, currents flowing through

the earth grid cause voltage gradients.

• Touch voltages: between hand accessible points

and the feet.

• Step Voltages: Between feet while walking.• Step Voltages: Between feet while walking.

• Electrocution risk.

• Use same injection circuit as earth impedance.

• Set the freq. selective multimeter to 1kΩ internal

resistance.

• Circular metal discs of 8cm radius simulate feet.

• Measure different points searching for high risk

areas.

Page 25: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

SURFACE POTENTIAL DISTRIBUTION

• Detailed state of the grounding system.

• Voltages measured at equidistant points over the grid.

• Graphs easily generated.

• Same injection circuit used to calculate impedance.

• Imaginary grid is laid over the substation

• With the Freq. selective multimeter measure voltage • With the Freq. selective multimeter measure voltage

difference between injection and equidistant points.

• Good performance grounding should be flat, slight

elevations at both ends.

Page 26: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

SOIL RESISTIVITY

• Important parameter for earth system design.

• Impedance influenced by the soil resistivity.

• Wenner array simplest method.

• Inject current through the current stakes.• Inject current through the current stakes.

• Frequency selective multimeter calculates the

resistance.

• Resistivity can be calculated using the formula

that suits this array:

Page 27: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

PARTIAL DISCHARGE TESTING

MODEL 831 PD MONITOR.

•Rack mounted fixed unit and one or more remote unit.

•Monitors utility assets: Cables, Transformers, Switchgear.•Monitors utility assets: Cables, Transformers, Switchgear.

•Up to 32 multiplexed inputs for PD recording.

•Up to 10 km distance from monitoring asset via fiber optic.

•Noise channel filtration for each input.

•PC and flat LCD panel.

•Graph and tables display.

•Available Sensors: Impedance sensor amplifier; Radiated

noise sensor amplifier; High Frequency Current Transformer;

and amplifier; Ultrasonic acoustic sensor and amplifier

Page 28: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

PARTIAL DISCHARGE TESTING

MODEL 831 PD TESTER.

•Portable PD testing.

•Monitors utility assets: Cables, Transformers, Switchgear.

•Driven by a notebook.

•Graphs and tables display.

•Noise channel filtration for each input.•Noise channel filtration for each input.

•Available Sensors: Impedance sensor amplifier; Radiated noise

sensor amplifier; High Frequency Current Transformer; and

amplifier; Ultrasonic acoustic sensor and amplifier.

MODEL 840 GIS PD MONITOR.

•Portable PD testing.

•Monitors Gas Insulating Switchgear.

•Driven by a notebook.

•Graphs and tables display.

•Noise channel filtration for each input.

•Fitted with a high frequency amplifier matched to the typical PD

signature of GIS equipment.

Page 29: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

METER TESTING

MODEL 679 3 PHASE METER TESTER.

•Fully digital meter tester.

•Microprocessor.

•0.1% or 0.05% accuracy.

•Optional clipons.

•10A inputs, or up to 118A with clipons.•10A inputs, or up to 118A with clipons.

•Backlit LCD display 16 lines of text.

MODEL 689 100A 3 PHASE METER TESTER.

•Fully digital meter tester.

•Microprocessor.

•3 phase switch mode current source.

•0.1% or 0.05% accuracy.

•Up to 100A meter testing.

•Backlit LCD display 16 lines of text.

•Stores up to 100 test records

Page 30: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

METER TESTING

MODEL 679 3 PHASE METER TESTER.

•Low cost, fully automatic single phase.

•Microprocessor conducts test sequence and calculates results.

•Automatically print of results or download to host computer.

•Easy bench or table top mount.•Easy bench or table top mount.

•User friendly.

MODEL 809E AUTOMATIC METER

VERIFICATION PANEL.

•For high revenue electronic kWh meter situations.

•Continually tests 5 or more meters in a substation.

•Cycle through each meter and test real and reactive power

accuracy.

•Connection to utility IT via modem or SCADA link.

Page 31: email Quality Red Phase Presentation · 820 CT Test Bridge Reference CTs CVT testing 590K CVT Tester Burden testing 704 CT Burden Tester. 590G-V2 CT ERROR TESTER KEY FEATURES

THANK YOU