FROSCO OIL INTERCEPTOR
SYSTEM
We Reserve All Intellectual PropertyRights In Our Products.
Tested By : SIRIM
Website : www.froscoweb.com
MR. ONGH/P : 012-549 7710
(NORTHERN)
MR. ALEXH/P : 012-713 0515
(SOUTHERN)
Email: [email protected] / [email protected]
MR. BRYANT TOHH/P : 017-8779458
(CENTRAL REGION)
MR. PETERH/P : 012-233 3861
(EAST MALAYSIA & INTERNATIONAL)
MR. ERIC ONGH/P : 016-919 9920
(CENTRAL REGION)
General
FROSCO Oil Interceptor works on the principle that oils are lighter than water and thusgravity causes the oil to rise and the water to fall. It is designed to separate oils and otherlight density volatile liquids which are discharged into the drainage system.
In commercial establishments, the spillages of oil or diesel could occur such as garages,transport workshops, diesel re-fueling and storage areas, and where vehicles or plant arewashed down or steam cleaned.
Function
The direct and indirect discharge of oily waste water into the natural waterways has adisastrous impact on the environment.
The installation of FROSCO Oil Interceptor in drain lines will help to prevent the pollution ofrivers, streams, drainage system and water treatment plants.
Mechanical Operation of FROSCO Oil Interceptor1. Perforated Bucket Baffles Assembly
When the influent entering the interceptor, the perforated bucket baffle assemblywill trap and collect chips, particles or other sediment which are frequently presentin industrial waste and could clog the drainage system.
2. Baffles AssemblyIt will help to minimize the velocity and turbulence of the incoming waste water andpermit the oil efficiently separate and rise above the normal establishes water line ofthe interceptor.
3. Deep Seal Integral TrapThe trap is to avoid the floating oil in the interceptor being escaped out into outletdrain lines.
4. Gravity Oil Drain-off AssemblyBy automatic or manual means, the floating oil flows through an adjustable draw-offpoint to a sump or a similar storage container awaiting disposal. Please refer to‘Collection of floating oil’ column for other means of oil collection.
5. Interceptor VentsTo eliminate pressure build-up inside the interceptor, a connection on each side of theinterceptor body allows the venting of the interceptor.
FROSCO OIL INTERCEPTOR
We Reserve All Intellectual PropertyRights In Our Products.
Website : www.froscoweb.comEmail : [email protected], [email protected]
VTSB Trading1
(D)
(C)(B)
Left or right (one only)
Air relief valve
This to be cut-off gravity
flow to storage tank applicationCover in Stainless Steel also
available in Aluminium Chequer
Plate upon request only
Vent Connection
Deep seal integral trap
C/W air relief valve
Graviti falls to bottom
and being pushed out
Special baffle plate
(available only for model
FEO-300 and above)
Sediment Bucket
OUTLET
INLET
This portion to be cut-off gravity
flow to storage tank application
One layer at oil
floating on top
OUTLETINLET
Deep seal integrat trap
C/W or rebal valve
Gravity on drain
Water fall to bottom
and being pushed out
Baffle Assembly
Open handle
Vant Connection
Perforated
(E)
(D)
(F)
(A)Baffle assembly
(A)
(F)
(B) x (C)
(E)
Sediment Bucket
Water line
Static water line
H J K
G
SECTION VIEW
G
Dimensional Data :
FROSCO OIL INTERCEPTOR
In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.
New Model Available:-(Eg.)
FEO100/M36FEO200/M34FEO300/M49
Frosco Oil Interceptor
Code
Flowrate (GPM)
Flowrate (litre /sec)
APipe Size
(mm)
BLength(mm)
CWidth(mm)
DHeight(mm)
E(mm)
F(mm)
G(mm)
H(mm)
J(mm)
K(mm)
FEO-007 7 0.53 50 407 382 306 89 217 82 102 77 128
FEO-010 10 0.76 50 509 407 306 89 217 89 102 102 204
FEO-015 15 1.14 50 509 407 458 101 357 96 102 102 204
FEO-020 20 1.50 75 763 407 458 101 357 102 128 179 306
FEO-025 25 1.89 75 763 407 509 102 407 107 128 179 306
FEO-035 35 2.65 100 864 560 534 127 407 127 154 204 306
FE0-050 50 3.78 100 864 560 611 153 458 126 154 204 306
FEO-075 75 5.68 100 1017 814 712 152 560 140 179 255 306
FEO-100 100 7.57 100 1372 916 814 203 611 127 179 331 331
FEO-150 150 11.35 100 1526 966 961 223 738 133 179 382 382
FEO-200 200 15.14 100 1754 1093 1042 254 788 140 179 483 458
FEO-250 250 18.92 100 1880 1144 1221 281 940 140 179 483 509
FEO-300 300 22.70 150 1932 1221 1296 330 966 140 179 509 509
FEO-350 350 26.49 150 2008 1271 1347 355 992 140 179 534 534
FEO-400 400 30.28 150 2109 1398 1499 431 1068 153 179 585 585
FEO-500 500 37.84 150 2312 1526 1780 433 1347 203 179 636 636
FEO-600 600 45.41 200 2541 1830 2008 482 1526 203 179 687 687
VTSB Trading2
The design allows the introduction of any type of liquids for separation so long as there issufficient specific gravity differential to allow gravity separation.
It is must complete with baffle screen, sediment bucket and deep seal integral trap, toeffectively intercept and separate the oil from water. It achieves an average of about 99% ofoil removal for intermittent and variable flows of water, oil or any combination of non-emulsified oil / water mixtures when the hydraulic retention time (HRT) is ≥ 5 minutes.
The design must also complete with oil ‘draw off’ for channeling and separating oil to aseparate oil storage tank pending for periodic maintenance disposal.
Interceptor material : (SPECIFICATION) Date : 1-1-2016
OIL INTERCEPTOR BODY MATERIAL OIL INTERCEPTOR COVERBody Stainless steel
Non Skid AluminiumBaffle Screen Stainless steel
Integral traps Stainless steel
TYPE OF STAINLESS STEEL MATERIAL AND THE GRADE
1. Grade SUS 316 High Corrosion ResistanceUse For Waste Water TreatmentWorldwide
2. Grade SUS 304 Good Corrosion ResistanceUse For Waste Water TreatmentWorldwide
3. Grade SUS 202 Normal Corrosion Resistance Use For Architectural Decor
4. Grade SUS 439 Fair Corrosion ResistanceUse For Hot Water Heater c/w Insulation Only & Architectural Decor
5. Grade SUS 444 Fair Corrosion ResistanceUse For Architectural Décor and Hot Water Heater c/w Insulation Only
Note: Unless otherwise specified or informed in advance all FROSCO Models will be quoted with stainless steel Grade SUS439 as a basic quote in order to meet competitive market requirement by end-users / contractors etc. However FROSCO willrevise the quotation upon request to quote for an alternative grade of stainless steel material and of a different price. (ForExport market, FROSCO will only quote and supply stainless steel grade SUS 316 or 304).
OIL INTERCEPTOR FO/14 7654/16 (Page 3) dated 1/1/2016 onwards.
Specification
FROSCO OIL INTERCEPTOR
VTSB Trading3
Correct sizing of oil interceptor is important and crucial :
1. It avoids under-utilization due to excessive over-sizing.2. It avoids backflow of oily waste water due to under-sizing.3. It ensures adequate hydraulic retention time of oily waste water in the interceptor, to achieves
optimum separation of oil from water, and thus the maximum % of interception of oil.
Steps to size FROSCO Oil Interceptor :
1. Estimate the peak volume of waste water [see note i] either in liters/sec. Or Gallon/min.2. Select the oil interceptor model with flow rating equal to peak volume.3. Provide storage tank [see note ii] size sufficient to accommodate the volumes of liquids to be
having the anticipated frequency of removal.
SIZING FOR FROSCO OIL INTERCEPTOR
(A) Sizing Method[Note i] To estimate the peak volume of waste water
(1) Covered AreaPeak Flowrate : Total of hose outlets, equipments etc that continuous discharging to drain line at one
timeExample: (Waste water from washing sinks)
Sink size : 40cm x 30cm x 15cm = 18,000cc = 18 Liters
To fill up the sink with full water, and discharge it, and to check the time taken to fully discharge the water. Itis recorded the time taken is about 30 seconds. Thus, the flowrate is 18 liters/ 30 sec = 8GPM
(2) Open area (uncovered)Peak Flowrate : Total area (length(meter) x Width(meter) x Rainfalls (mm/sec.)
Example: Length = 20 meter, Width=10 meter, Rainfall = 50 mm/hourTherefore, Peak Flowrate = 20 x 10 x 50/3600 = 2.78 liters/sec.
(B) Sizing for Oil Storage Tank
[Note ii] Sizing for Oil Storage Tank1. To estimate the volume of oil into the interceptor2. Frequency of maintenance routine (once a month, twice a month, etc)3. Size the oil storage tank double the size of the total accumulated oil during the period (50% of oil
+ 50% of water) to cater for the requirements.
Example : An average of 5 liters daily of black oil is spilled and washed away into the drain lines. Assumingthat the contractor (licensed by DOE) is schedule to come and collect the waste black oil once amonths. The total black oil accumulated in 30 days time is about 150 liters. The capacity for oilstorage should be double = 300 liters.
Note : The above sizing methods are just a guideline only. In order to achieve better affluent waterrange, kindly refer to the manufacturer/supplier for further advise.
NB. OIL STORAGE TANK SIZE = 1200mm x 1200mm x 750mm (H) (15-30 DAYS – 300 L/OIL)
VTSB Trading4
Installation
FROSCO OIL INTERCEPTOR
OIL INTERCEPTOR
INSTALLATION
In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.
OIL INTERCEPTOR
INSTALLATION
Inlet
Vent connection
Gravity oil
draw-off connection
Adjustable gravity oil
drain-off assembly Adjustable gravity oil
drain-off assembly
Static water line
Operating
water line
Adjustable
metal tube
Pipe to oil
storage tank
Interceptor
body
In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor Vent
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor Vent
FROSCO OIL
SKIMMER
Suction line
Access cover
Draw-off line
from interceptor
Vent pipe
Concrete slab
Oil storage tank
Support bracket
FROSCO OIL
INTERCEPTOR
From floor drain
Concrete pit
Vent stack
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
Gravity
draw-off
Oil Storage Tank
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor VentVent stack
FROSCO OIL
SKIMMER
OIL INTERCEPTOR
INSTALLATION
In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.
OIL INTERCEPTOR
INSTALLATION
Inlet
Vent connection
Gravity oil
draw-off connection
Adjustable gravity oil
drain-off assembly Adjustable gravity oil
drain-off assembly
Static water line
Operating
water line
Adjustable
metal tube
Pipe to oil
storage tank
Interceptor
body
In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor Vent
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor Vent
FROSCO OIL
SKIMMER
Suction line
Access cover
Draw-off line
from interceptor
Vent pipe
Concrete slab
Oil storage tank
Support bracket
FROSCO OIL
INTERCEPTOR
From floor drain
Concrete pit
Vent stack
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
Gravity
draw-off
Oil Storage Tank
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor VentVent stack
FROSCO OIL
SKIMMER
VTSB Trading5
FROSCO OIL INTERCEPTOR
In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.
OIL INTERCEPTOR
INSTALLATION
In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.
OIL INTERCEPTOR
INSTALLATION
Inlet
Vent connection
Gravity oil
draw-off connection
Adjustable gravity oil
drain-off assembly Adjustable gravity oil
drain-off assembly
Static water line
Operating
water line
Adjustable
metal tube
Pipe to oil
storage tank
Interceptor
body
In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor Vent
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor Vent
FROSCO OIL
SKIMMER
Suction line
Access cover
Draw-off line
from interceptor
Vent pipe
Concrete slab
Oil storage tank
Support bracket
FROSCO OIL
INTERCEPTOR
From floor drain
Concrete pit
Vent stack
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
Gravity
draw-off
Oil Storage Tank
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor VentVent stack
FROSCO OIL
SKIMMER
OIL INTERCEPTOR
INSTALLATION
In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.
OIL INTERCEPTOR
INSTALLATION
Inlet
Vent connection
Gravity oil
draw-off connection
Adjustable gravity oil
drain-off assembly Adjustable gravity oil
drain-off assembly
Static water line
Operating
water line
Adjustable
metal tube
Pipe to oil
storage tank
Interceptor
body
In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor Vent
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor Vent
FROSCO OIL
SKIMMER
Suction line
Access cover
Draw-off line
from interceptor
Vent pipe
Concrete slab
Oil storage tank
Support bracket
FROSCO OIL
INTERCEPTOR
From floor drain
Concrete pit
Vent stack
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
Gravity
draw-off
Oil Storage Tank
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor VentVent stack
FROSCO OIL
SKIMMER
OIL INTERCEPTOR
INSTALLATION
In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.
OIL INTERCEPTOR
INSTALLATION
Inlet
Vent connection
Gravity oil
draw-off connection
Adjustable gravity oil
drain-off assembly Adjustable gravity oil
drain-off assembly
Static water line
Operating
water line
Adjustable
metal tube
Pipe to oil
storage tank
Interceptor
body
In keeping with our policy of updating products we reserve the right to make improvement or changes without notice.
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor Vent
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor Vent
FROSCO OIL
SKIMMER
Suction line
Access cover
Draw-off line
from interceptor
Vent pipe
Concrete slab
Oil storage tank
Support bracket
FROSCO OIL
INTERCEPTOR
From floor drain
Concrete pit
Vent stack
FROSCO SEDIMENT WATER DRAIN
FSWD 335 (BO/SO)
Floor drain
Gravity
draw-off
Oil Storage Tank
FROSCO OIL
INTERCEPTOR
To sewer
Interceptor VentVent stack
FROSCO OIL
SKIMMER
VTSB Trading6
Min 250mm Gap Min 250mm Gap(A)
Min 150mm Gap Min 150mm Gap
Min 150mm GapMin 150mm Gap
(B)
PLAN VIEW
INLETOUTLET
OUTLET INLET
SECTION VIEW
Ground Level
Enzyme Dosing Tube
PVC Pipe 25mmØ
INLET OUTLET
25mmØ lower than inlet
Selected Floor
Tiles As Per IDExtra Metal Cover
Steel Frame With
HDC Cover
Suspended from softfit with 4 nos
threading rod on each side and 2
nos of 2'' x 2'' angle iron
TOP VIEW
SECTION VIEW
FROSCO OIL
INTERCEPTOR
2 Pieces -Selected Floor
Tiles As Per ID
Perforated
Water line
Static water line
This portion to be cut-off gravity
flow to storage tank applicationVant Connection
(B) x (C)
(D)(F)Sediment Bucket
One layer at oil
floating on top
Deep seal integrat trap
C/W or rebal valve
Gravity on drain
Water fall to bottom
and being pushed out
FROSCO OIL INTERCEPTOR
( INSTALLATION GUIDES )
Together, Enriching Our Environment
Inside Building Installation ( Suspended )
Outside Field Installation ( Sunken )
In keeping with our policy of updating products we reserve the right
To make improvements or changes without notice.
(E)
(A)
(K)(J)(H)
Pipe Size 150mmØ Pipe Size 150mmØ
FROSCO OIL INTERCEPTOR
Top Up With 100mm
Thick Concrete
Concrete
Slab
Angle Cover
Metal
Bracket
FROSCO OIL INTERCEPTOR(INSTALLATION GUIDE)
In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.
VTSB Trading7
Maintenance Manual draw-off Automatic draw-off
Commissioningperiod
During the first 4 weeks of operation,regular inspection of the internalcondition of the interceptor should bemade to determine how often the oilneed to be drained off and theperforated bucket baffles assemblyemptled.
During the first 4 weeks ofoperation check the oil storagetank for build-up, and theperforated bucket bafflesassembly to determine howoften it needs to be emptled.
Routinemaintenance
Remove main cover, drain-off oil, emptyand clean perforated bucket bafflesassembly.
Remove main cover, empty andclean perforated bucket bafflesassembly.
Annual maintenance
Drain and clean interceptor tankcompletely. Check for paintworkdeterioration, and treat as required.Check joints and seal.
Drain and clean interceptor tankcompletely. Check for paintworkdeterioration, and treat asrequired. Check joints and seal.
Ensure that only OIL is taken from interceptor
1. Normally used in automatic installation with drawn-off oil collecting in storage tank. Thissetting will retain a layer of oil in the interceptor
2. If during the normal working condition, water is found entering the draw-off, adjust draw-offupward from 1/8” to ¼”.
Ensure that ALL OIL is removed from interceptor
1. Normally used with manual draw-off installation. This setting will allow water to enter thedraw-off line.
2. If during the normal working condition, oil is found to be remaining in the interceptor :• For manual installation : Draw-off oil more frequently and or lower draw- off by
another 1/8”.• For automatic installation : Lower draw-off by another 1/8”.
Maintenance
VTSB Trading8
FROSCO Oil Interceptor system has been tested by SIRIM (SIRIM ref. no : 237/16/119).According to the test result, FROSCO Oil Interceptor achieves 99% oil removal when thehydraulic retention time (HRT) is about 5 minutes. It concludes that FROSCO Oil Interceptor canbe seen as a pretreatment system that can help reduce the negative impact to theenvironment.
COLLECTION OF FLOATING OIL FROM FROSCO OIL INTERCEPTOR
Method (I)1. Manual scoop, periodically - Periodically, the floating oil in the interceptor is to be scoop
and cleaned away.2. Gravity flow to oil storage tank.3. Automatic skimming by oil skimmer - Setting of oil skimmer to skim floating oil in the
interceptor on regular basis.
Collection of floating oil by Oil Storage Tank
( Method II )1. Frosco Oil Interceptor is suitable for floor standing or recessed installation.2. Vent and draw-off connections are provided on both sides of the interceptor for ease of
installation and use. All connection points not used must be sealed.3. To receiving container. For automatic operation, use storage tank. For manual operation,
any suitable container may be used.4. Oil level detector (upon request) which is giving signal for period maintenance can be
installed in the oil storage tank.
SIRIM TEST
VTSB Trading9
BELT TYPE SKIMMER
For Use With :•Metalworking Coolants•Parts Washer Fluids•Wastewaters•Pressure Spray Water•Water Treatment System
Mini-Skimmer have been in use through outthe world since 1980. Thousand are useddaily to remove unwanted floating or ‘ tramp’oil.
They are small, run very quietly, and use avery dependable permanent magnet motor.Standard models for industrial users includeoil pick-up rate to 4 gallons/hour, loose orfixed tail pulley design, and a choice ofpolyurethane ( for coolants & oil/water ) orstainless steel ( for part washing ) belts in foursizes.
Special skimmer with other options such asspecial belt lengths ( to 20 ft ), two belts,stainless motor covers.
FEATURES & CHOICE• Lifts 1 quart to 4 gallons per hour!• Polyurethane belts for coolants!• Stainless steel belts for partswashers!• Four standard belts lengths!• Special belt lengths to 20 ft.• Loose or fixed tail pulley system!• Mounts on vertical / horizontal surfaces!• World’s smallest!• Fits in tiny spaces!• Dependable permanent magnet motor!• Steel or stainless wetted parts!
Collecting of floating oil by Oil Skimmer( Method III ).
In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.
OIL SKIMMER WAYNEMade in USA
(FOR THE SERVICE AND MAINTENANCE USE)
VTSB Trading10
BELT TYPE SKIMMER
Economy Oil Skimmer For CoolantsModel DBS
The Motor : High quality, quiet & dependable permanentmagnet motor with stainless steel sheath & sixft. cord. 115v with USA type three prong plug,220v with Euro two prong plug.
The Belt : 1” wide flat polyurethane belt has greatadherance for floating oils. Two standardlengths - 8” or 12” from mounting bracketbase to the lowest point.
Oil Pick-up : A choice! 10rpm will lift approx. 1 quart perhour. 30rpm collects approx. 7 quarts perhour.
The Other : Nylon drive pulley, stainless steel mountingbracket & scraper / trough assembly. Steel tailpulley and supporting bar (holds tail pulley inplace).
Warranty : One year, from shipment to user, coveringmanufacturing defects only.
Use For : Coolants, other oil / water applications inwastewater or water treatment below 120F.Not for use with parts washers.
Parts
Model Number Reach Lift Rate
USA WorldwideWith CE
Mark
115/1/60 115/1/60 220/1/50 220/1/50
DBS-10-270P1-FTPS 8” 1qt./hr 37800 31680 31685 31695
DBS-10-360P1-FTPS 12” 1gal./hr 37805 31681 31686 31698
DBS-30-270P1-FTPS 8” 7qts./hr 37810 31882 n/a n/a
DBS-30-360P1-FTPS 12” 7qts./hr 37820 31883 n/a n/a
Model DBS answers the world’s needs for high quality, low cost belt oil skimmer for metalworking coolants!
Note : Belt lengths can be easily made for reaching from 2” to 50ft!
Belt “Reach”This is the distance from the mounting bracket base to the lowest point
Overall Dimension8” reach 13” H x 4” W x 5” D
12” reach 17” H x 4” W x 5” D
Weight5.5 Ibs. Individually boxed
(FOR THE SERVICE AND MAINTENANCE USE)
VTSB Trading11
1” Wide Belt Skimmers for Use With Metalworking COOLANTS and Wastewater Applications
Many Thousands of Mini-SkimmersTM have been used throughout theworld since 1990 for removing tramp oils from coolants andwastewaters. There are choices of polyurethane belt – cog type on MSB& lower cost Flat Type on Model DBS, with five choices on standard“reach” lengths & two oil collection rates. Custom units can be built withstainless steel metal parts and belts.
• 5 Belt Reach Choices From 5” to 24” Down!• Choices of Cogged or Flat Polyurethane Belt!• Steel Stabilizer Bar Holds Tail Pulley in place!• Dependable, Quiet Permanent Magnet Motor!• Choices of 1 Qt (ltr) or 1 Gal. (4 ltrs) per Hour!• Small Size – Fits Almost Anywhere!• Thousands Sold Worldwide Since 1990!
Select Order Number For Cost InquiryMODEL MSB – Cog Polyurethane BeltCOLLECTION RATE1 Quart or Liter per Hour 1 Gallon or 4 Liters per Hour
Reach 115/1/60 220/1/50/CE 115/1/60 220/1/50/CE
8” 31820 31700 31825 31716
12” 31821 31701 31825 31717
18” 31822 31702 31827 31718
24” 31823 31703 31828 31719
Reach 115/1/60 220/1/50/CE 115/1/60 220/1/50/CE
5” 37802 31692 37803 31707
8” 31680 31695 31882 31697
12” 31681 31696 31883 31698
18” 31682 31694 31884 31699
24” 31683 31693 31885 31705
MODEL DBS – Flat Polyurethane BeltCOLLECTION RATE1 Quart or Liter per Hour 1 Gallon or 4 Liters per Hour
MOTORS are permanent-magnet typewith SS sheath cover & 6 ft. cordset115/1/60 – 0.0065 amp 220/1/50/CE –0.05 amp draw. Stainless steelmounting bracket & scraper/ troughassy. Steel tail pulley & stabilizer barnylon drive pulley. Max, suggestedtemp – 120 F (50oC) – Ship wt 5-9 Ibs.1 year warranty against manufactureddefects. Belts Warranted 90 days forbreakage only. Further warranty detailson request.
Manufacturers of Oil Skimmers, Blowers and Filter/ Ventilator Systems
MSBCog Belt
DBSFlat Belt
MOTOR
4 1/4"
4 5/8"
BELT
REACH 3 1/4" Wide
From Front
TROUGH
Mounting Surface
TA
IL P
UL
LE
YB
EL
TD
RIV
E P
UL
LE
Y
3 /4"
1"
(FOR THE SERVICE AND MAINTENANCE USE)
VTSB Trading12
For Central Coolant Systems and wastewater/ Water treatment SystemsMAXI- SkimmersTM are a recent development to provideindustry with an economical, corrosion-free, wide beltskimmer for central coolant tanks, wastewater and watertreatment applications with collection rates from 2.5 to 10gallons per hour. Economy is gained by using manycomponents which are purchased in volume for other designs!
Benefits!Economical cost and Dependable Operation!Choice of 2.5, 5.0 or 10 Gallons per Hour Collection!Std Belt Lengths to 10 ft. – Can be made to 50ft. down!Handles Fluctuating Liquid Levels!No Corrosion – All Stainless Polymer Materials!Takes Little space & is easy to install!Furnished as a complete System with Accessories!
Features!Uses 2 – 4” wide Polyurethane or Stainless Steel Belt!Uses Quiet & Dependable Hurst Permanent Magnet Motor!UHMW Bearing-Grade Polymer Sraper Blade!Choice Of three Standard Collection Rates!Nice Appearance!1 Year Limited Warranty!
Accessories (Included)!Timer For Automatic Control – Three Settings/ 24 Hrs!Ground Fault Interrupter for Electrical Safety!3 Foot Oil Outlet Extension Hose!
TechnicalMotor : 115/1/60, 30 rpm, cont. dutyCordset : 6 ft. three prong.Amp. Draw : 0.65 (7 watts)Frame : Stainless Steel & UHMW endsCollects : 2.5, 5 or 10 Gph.Temp. : 120 F. Max (with poly belt).Ship Weight : 15 – 30 Ibs.
Optional Accessories.Adjustable stand for drum collection.Diverter for oil/water separation.Handle for portability.
Modifications Include 220vac. 12-24 vdc motors. Collection rates. Stainless steel belt and belt reaches to 50 ft.
Manufacturers of Oil Skimmers, Blowers and Filter/Ventilator Systems
(FOR THE SERVICE AND MAINTENANCE USE)
VTSB Trading13
1. To fill up the FROSCO Oil Interceptor with clean water, free of oil, dirt or othercontaminants when it is properly installed.
2. The amount of debris such as sand, gravel, dirt, leaves, grass cutting, etc, permittedto enter the system must be minimized. Sediment bucket should be inspected andcleaned on daily/ weekly / biweekly basis depending on the incoming volume.
3. The floating oil (oil trapped) in the interceptor should be cleaned on daily/ weekly /biweekly basis depending on the incoming volume.
a) Manual Scoop (Method I)To scoop the floating oil manually on regular basis.
b) Oil Storage Tank (Method II)Refer to column on the oil storage tank application.
c) Oil Skimmer (Method III)Oil Skimmer is pre-set to run on daily / weekly basis for certain time duration(depend on oil content) to skim up the floating oil and channel it to aseparate oil container awaiting for disposal.
Operating Manual
To assure maximum effectiveness of the system, certain precautions should be observed.1. The amount of debris such as sand, gravel, dirt, leaves, grass cuttings, etc., permitted
to enter the system must be minimized. Perforated bucket of the sediment trapbefore the interceptor should be inspected and cleaned on a regular basis.
1. Automotive and truck engine crankcase oil should not be drained into the systemsludge and deposits present in the oil will significantly reduce the effectiveness ofthe interceptor.
1. Hydrocarbons entering the separator will be in a free non-emulsified state andcapable of being separated from water in a gravity separator.
1. Detergents have a definite affinity for hydrocarbons. Wash water from truck washingracks must be routed directly to a sanitary sewer or treated with special equipment.Water containing detergents must not be allowed to enter the system, unless thedetergents is biodegradable.
1. Water flow rates are within the specification. Adequate water retention time willensure proper separation of oil/ water mixture.
A flow controller is advisable to install at the upstream of the unit to ensure no accidentaldischarge of oil during periods of excessive wastewater flow.
Steps To Further Improve Effectiveness
VTSB Trading14
Model Photo Model Photo
FOS-50BELT SKIMMER
FFS-1BFLOATING SKIMMER
FOS-50BBELT SKIMMER
FFS-2FLOATING SKIMMER
FOS-50NBELT SKIMMER
FWOS-300POLYMER WHEEL SKIMMER
FOS-50N-PVCBELT SKIMMER
FTB-80BELT SKIMMER
FNC-40BELT SKIMMER
FOS-2BELT SKIMMER
Type Of Frosco Oil Skimmer
(FOR THE SERVICE AND MAINTENANCE USE)
VTSB Trading15
Model Photo Model Photo
FWOS-300A400POLYMER WHEEL SKIMMER
FOS-4BELTSKIMMER
FWOS-300BPOLYMER WHEEL SKIMMER
FWOSPOLYMER WHEEL SKIMMER
FFS-1FLOATING SKIMMER
FFSCL-A-AIR-1POLYMER WHEEL SKIMMER
FFS-5POLYMER WHEEL SKIMMER
FFSCL-ELDC-1POLYMER WHEEL SKIMMER
Type Of Frosco Oil Skimmer
(FOR THE SERVICE AND MAINTENANCE USE)
VTSB Trading16
Model Photo Model Photo
FM-100-1RS FM100-6RS
FM-100-2RS FM100-8RS
FM-100-4RS FM100-10RS
Type Of Frosco Oil Cleaner
(FOR THE CLEANING, SERVICE AND MAINTENANCE USE)
VTSB Trading18
FROSCO PRODUCTS ALWAYS COME WITH REGISTERED TRADE MARK, MODEL AND SERIAL NUMBER IN EVERY UNIT SUPPLIED.
1. Stainless steel body ( paint sprayed FROSCO trade mark ) – both side2. Stainless steel cover ( embossed FROSCO trade mark ) – both covers3. Next to dosing hole a pieces of PVC Plate with FROSCO trade mark, model and serial number.
4. Hydrafilter Baffle ( embossed FROSCO trade mark and serial number ).
FROSCO Oil Interceptor
Model : xxxxSerial Number : xxxx
Note : We reserve all the rights to take up legal action againt those who copy our product and registeredTRADE MARK.
VTSB Trading20
SEDIMENT WASTE DRAIN
In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.
300mm
300mm
300mm
Top Access
Hinged Grating
Stainless Steel
Bucket
Removable
Bell Trap
Pipe size
75mmØ/ 100mmØ/ 150mmØ
300mm
300mm
300mm
Top Access
Hinged Grating
Stainless Steel
Bucket
OUTLET
OUTLETPipe size
100mmØ
Sediment Waste Drain
Model : FSWD 335 BO
Bottom Outlet
Sediment Waste Drain
Model : FSWD 335 SO
Side Outlet
100mm
200mm
VTSB Trading21
FROSCO HF OIL SEPARATOR SYSTEM(HEAVY FLOW OIL SEPARATOR)
(COMPLETE WITH SKIMMER FILTRECEPTOR OR DETERGENTCEPTOR SYSTEM)
( GREY WATER )
VTSB Trading22
Frosco Oil Separator Code
Flowrate(GPM)
Flowrate (litre/sec)
APipe Size
(mm)
BLength(mm)
CWidth(mm)
DHeight(mm)
E(mm)
F(mm)
FEO-300 (OCBV)-IP 300 22.70 150 3000 1221 1296 330 966
FEO-350 (OCBV)-IP 350 26.49 150 3000 1271 1347 355 992
FEO-400 (OCBV)-IP 400 30.28 150 3000 1398 1499 431 1068
FEO-500 (OCBV)-IP 500 34.05 150 3000 1526 1780 433 1347
FEO-600 (OCBV)-IP 600 37.84 200 3000 1830 2008 482 1526
Frosco Oil Separator Code
Flowrate(GPM)
Flowrate (litre/sec)
APipe Size
(mm)
BLength(mm)
CWidth(mm)
DHeight(mm)
E(mm)
F(mm)
FEO-300 (OCBV)-IP 300 22.70 150 3000 1221 1296 330 966
FEO-350 (OCBV)-IP 350 26.49 150 3000 1271 1347 355 992
FEO-400 (OCBV)-IP 400 30.28 150 3000 1398 1499 431 1068
FEO-500 (OCBV)-IP 500 34.05 150 3000 1526 1780 433 1347
FEO-600 (OCBV)-IP 600 37.84 200 3000 1830 2008 482 1526
Frosco Oil Separator Code
Flowrate(GPM)
Flowrate (litre/sec)
APipe Size
(mm)
BLength(mm)
CWidth(mm)
DHeight(mm)
E(mm)
F(mm)
FEO-300 (OCBV)-EP 300 22.70 150 3000 1221 1296 330 966
FEO-350 (OCBV)-EP 350 26.49 150 3000 1271 1347 355 992
FEO-400 (OCBV)-EP 400 30.28 150 3000 1398 1499 431 1068
FEO-500 (OCBV)-EP 500 34.05 150 3000 1526 1780 433 1347
FEO-600 (OCBV)-EP 600 37.84 200 3000 1830 2008 482 1526
Frosco Oil Separator Code
Flowrate(GPM)
Flowrate (litre/sec)
APipe Size
(mm)
BLength(mm)
CWidth(mm)
DHeight(mm)
E(mm)
F(mm)
FEO-300 (OCBV)-EP 300 22.70 150 3000 1221 1296 330 966
FEO-350 (OCBV)-EP 350 26.49 150 3000 1271 1347 355 992
FEO-400 (OCBV)-EP 400 30.28 150 3000 1398 1499 431 1068
FEO-500 (OCBV)-EP 500 34.05 150 3000 1526 1780 433 1347
FEO-600 (OCBV)-EP 600 37.84 200 3000 1830 2008 482 1526
FROSCO HF OIL SEPARATOR - (OCBV Series) - Model : EP & IP
(D)
This portion to be
cut-off gravity
flow to storage tank
application
One layer at oil
floating on top
OUTLET
INLET
Deep seal
integrat trap
C/W or rebal valve
Gravity on drain
Water fall to
bottom and
being pushed out
(A)
(F)
(B) x (C)
(E)
Ball Gate
Valve
3000 mm
2008 mm
3000 mm X 1830mm
FROSCO HF OIL SEPARATORMODEL : FEO-600 (OCBV)-EP
(OVER FLOW CONTROL BALL VALVES)- EXTERNAL FLOW
SIZE : (3000 x 1830 x 2008H)
HF : Heavy Flow
(D)
This portion to be
cut-off gravity
flow to storage tank
application
(F)
(B) x (C)
(E)
3000 mm
2008 mm
3000 mm x 1830mm
FROSCO HF OIL SEPARATORMODEL : FEO-600 (OCBV)-IP
(OVER FLOW CONTROL BALL VALVES)- INTERNAL FLOW
SIZE : (3000 x 1830 x 2008H)
HF : Heavy Flow
(A)
OUTLET
One layer at oil
floating on top
Deep seal
integrat trap
C/W or rebal valve
Gravity on drain
Water fall to
bottom and
being pushed out
Ball Gate
Valve
37.84
45.41
37.8445.41
VTSB Trading23
In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.
FROSCO OIL SEPARATOR SYSTEM(XL) - MODEL : SFD/FMB/FBD
TABLE
NO FROSCO SKIMMING / OIL SEPARATOR (MODEL SFD) FILTER CEPTOR ( MODEL FMB) BIO-DETERGENCEPTOR (MODEL FBD)
1 MODEL SFD 1115XL MODEL FMB 1115 MODEL FBD 1115
SIZE : 2026 x 966 x 961 (H) 2000 x 1000 x 1500 (H) 2000 x 1000 x 1500 (H)
2 MODEL SFD 1125XL MODEL FMB 1125 MODEL FBD 1125
SIZE : 2380 x 1144 x 1221 (H) 2500 x 1350 x 1500 (H) 2500 x 1350 x 1500 (H)
3 MODEL SFD 1135XL MODEL FMB 1135 MODEL FBD 1135
SIZE : 2508 X 1271 X 1347 (H) 2650 x 1650 x 1500 (H) 2650 x 1650 x 1500 (H)
4 MODEL SFD 1145XL MODEL FMB 1145 MODEL FBD 1145
SIZE : 2812 x 1526 x 1780 (H) 3000 x 1850 x 2000 (H) 3000 x 1850 x 2000 (H)
5 MODEL SFD 1160XL MODEL FMB 1160 MODEL FBD 1160
SIZE : 3041 x 1830 x 2008 (H) 3000 x 2550 x 2200 (H) 3000 x 2550 x 2200 (H)
Oil / Grease
Skimmer
Plug Point
Skimmer Timer
FROSCO OIL SKIMMER
C/W Trolly & Separator
Model : FIS/SSV/P 2-100 US
Skimmer
Belt
Water Level
BIODETERGENTCEPTORSKIMMER
OIL SEPARATOR
BASEMENT
FROSCO AUTOMATIC
DOSING UNIT
Plug Point
13amp
TREATMENT
PRODUCT
Sensor
GREASE INTERCEPTOR
C/W FILTRATION SYSTEM
OUTLET
Manhole
OIL BARREL
PUMP
FOR BASEMENT USE
SKIMMER
OIL SEPARATOR
GPT
(Gross Pollutant Trap)
Skimmer
Belt
Oil / Grease Collection Tank
(Optional)
Oil / Grease
Skimmer
Plug Point
Skimmer Timer
Trolley
(Optional)
Water Level
Ground Level
SECTION VIEW
Air Vent Pipe Air Vent Pipe
MANHOLE
or
DRAIN
Plug Point
13amp
TREATMENT
PRODUCT
Note : INSTALLATION GUIDES
BIODETERGENTCEPTOR
MANHOLE
or
DRAIN
BIODETERGENTCEPTOR
GPT
(Gross Pollutant Trap)
ADU
PUMP
PLAN VIEW
SKIMMER
OIL SEPARATOR
Oil SkimmerOil Separator Pipe
Overflow Pipe
Overflow Pipe
FROSCO OIL SKIMMER
C/W Trolly & Separator
Model : FIS/SSV/P 2-100 US
Oil Separator Pipe
FROSCO AUTOMATIC
DOSING UNIT
Collection Sump Pit c/w Strainer Basket
Collection Sump Pit c/w Strainer Basket
VTSB Trading24
Collection Sump Pit or
GPT (Gross Pollutant Trap)
c/w Strainer Basket
Skimmer
Belt
Oil / Grease Collection Tank
(Optional)
Oil / Grease
Skimmer
Plug Point
Skimmer Timer
Trolley
(Optional)
Water Level
Ground Level
SECTION VIEW
Air Vent Pipe Air Vent Pipe
MANHOLE
Plug Point
13amp
TREATMENT
PRODUCT
MANHOLE
ADU
PUMP
PLAN VIEW
Oil SkimmerOil Separator Pipe
Frosco Oil
Separator c/w Oil
Skimmer
Frosco multiple wall
Detergenceptor c/w ADU
Treatment Chemical
Product
Frosco Oil Separator c/w Multiple Wall Detergenseptor System (For External Use)
FROSCO AUTOMATIC
DOSING UNIT
FROSCO OIL SKIMMER
C/W Trolly & Separator
Model : FIS/SSV/P 2-100 US
Collection Sump Pit or
GPT (Gross Pollutant Trap)
c/w Strainer Basket
Frosco Oil
Separator c/w Oil
Skimmer
Frosco multiple wall
Detergenceptor c/w ADU
Treatment Chemical
Product
FROSCO OIL SEPARATOR C/W MULTIPLE WALL
DETERGENCEPTOR SYSTEM (FOR EXTERNAL USE)TABLE :
See for view (One Complete Set System)
In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.
NO FROSCO OIL SEPARATOR C/W OIL SKIMMER (A) FROSCO MULTIPLE WALL DETERGENCEPTOR COMPLETE SET
C/W ADU TREATMENT CHEMICAL PRODUCT (B)
1 MODEL : FOSS 0300XL + (FIS/SSV/P2-100US) + TROLLEY) MODEL : FMWD 0300XXL+(ADU & TREATMENT CHEMICAL) (A+B)
SIZE : 2026mm (L) x 966mm (W) x 961mm (H) SIZE : 2000mm (L) x 1000mm (W) x 1500mm (H) C/Set
2 MODEL : FOSS 0350XL + (FIS/SSV/P2-100US) + TROLLEY) MODEL : FMWD 0350XXL+(ADU & TREATMENT CHEMICAL) (A+B)
SIZE : 2380mm (L) x 1144mm (W) x 1221mm (H) SIZE : 2500mm (L) x 1350mm (W) x 1500mm (H) C/Set
3 MODEL : FOSS 0400XL + (FIS/SSV/P2-100US) + TROLLEY) MODEL : FMWD 0400XXL+(ADU & TREATMENT CHEMICAL) (A+B)
SIZE : 2508mm (L) x 1271mm (W) x 1347mm (H) SIZE : 2650mm (L) x 1650mm (W) x 1500mm (H) C/Set
4 MODEL : FOSS 0500XL + (FIS/SSV/P2-100US) + TROLLEY) MODEL : FMWD 0500XXL+(ADU & TREATMENT CHEMICAL) (A+B)
SIZE : 2812mm (L) x 1526mm (W) x 1780mm (H) SIZE : 3000mm (L) x 2300mm (W) x 1800mm (H) C/Set
5 MODEL : FOSS 0600XL + (FIS/SSV/P2-100US) + TROLLEY) MODEL : FMWD 0600XXL+(ADU & TREATMENT CHEMICAL) (A+B)
SIZE : 3041mm (L) x 1830mm (W) x 2008mm (H) SIZE : 3000mm (L) x 2550mm (W) x 2200mm (H) C/Set
FROSCO OIL SEPARATOR C/W MULTIPLE WALL DETERGENCEPTOR SYSTEM (FOR EXTERNAL USE)
TABLE
Collection Sump Pit c/w Strainer Basket
Collection Sump Pit c/w Strainer Basket
VTSB Trading25
Wate
r R
eta
inin
g P
on
d
Wate
r R
eta
inin
g
Po
nd
in
flu
en
tp
ara
mete
r m
ay
req
uir
e t
oco
mp
ly t
o
rele
van
tau
tho
rity
's
reg
ula
tio
n &
gu
ide lin
e
Sele
cte
d O
ilIn
terc
ep
tor
sh
ou
ld b
e a
ble
to r
em
ove O
& G
in h
igh
est
rem
oval
eff
icie
ncy in
th
e
perc
en
tag
e 9
9%
on
ly
Oil In
terc
ep
tor
FE
O 6
00
Eff
ecte
d s
erv
ice a
rea
on
ly C
/W 3
00 x
200
Scu
pp
er
Dra
in A
rou
nd
Sg
.
(Riv
er)
Air
cra
ft S
erv
ice a
nd
Park
ing
are
a
(Wate
r je
t +
Rain
fall (
1st
Wash
)
at
acfe
cte
d a
rea o
nly
)
Oil In
terc
ep
tor
FE
O 6
00
Oil In
terc
ep
tor
FE
O 6
00
Oil In
terc
ep
tor
FE
O 6
00
OP
EN
AR
EA
FR
OS
CO
OIL
IN
TE
RC
EP
TO
R
SC
HE
MA
TIC
PL
AN
In k
eep
ing
wit
h o
ur
po
licy o
f u
pd
ati
ng
pro
du
cts
we r
eserv
e t
he r
igh
t to
make im
pro
vem
en
t o
r ch
an
ges w
ith
ou
t n
oti
ce.
CO
VE
RE
D W
OR
K S
HO
P
(SE
RV
ICE
& M
IAN
TE
NA
NC
E)
( L
x W
)
( L
x W
)
Oil In
terc
ep
tor
200 G
pm
Oil In
terc
ep
tor
300 G
pm
Bo
ein
g 7
47
Serv
ice
Bo
ein
g 7
37
Serv
ice FW
D 3
35
Waste
Dra
in
FW
D 3
35
Waste
Dra
in
AIR
PLA
NES
SE
RV
ICE
CEN
TRE
VTSB Trading26
Unknown
FR
OSC
O O
IL S
KIM
ME
RS
EPA
RA
TO
R
CO
LL
EC
TIO
N S
UM
P P
ITc/w
S/S
TE
EL B
AS
KE
T
FR
OSC
O M
UL
TIP
LE
WA
LL
DET
ER
GE
NC
EP
TO
R
Skim
me
r B
elt
Oil / G
rease C
ollectio
n T
an
k(O
ptional)
Oil
/ G
rease S
kim
merP
lug P
oin
t
Skim
mer T
imer
Tro
lley
(Optional)
Pro
po
se 'E
' D
imensio
n S
ubje
ct
To Inle
t P
ipe G
radie
nt
Gro
und L
evel
SE
CT
ION
VIE
W
Air V
ent
Pip
eW
ate
r Le
vel
Subm
ers
ible
Pu
mp
Sensor
SC
UP
PE
R D
RA
ING
round L
evel
In k
eep
ing
wit
h o
ur
po
lic
y o
f u
pd
ati
ng
pro
du
cts
we
res
erv
e t
he r
igh
t to
ma
ke i
mp
rov
em
en
t o
r ch
an
ge
s w
ith
ou
t n
oti
ce.
FR
OS
CO
AU
TO
MA
TIC
DO
SIN
G U
NIT
Plu
g P
oin
tP
lug P
oin
t
Unknown
Pro
pose 'E
' D
imensio
n S
ubje
ct
To Inle
t P
ipe G
radie
nt
Wate
r Level
Wa
ter
Level
TR
EA
TM
EN
T P
RO
DU
CT
Sc
upp
er
Dra
in
Ra
il T
rac
k
Cu
rve
On
- B
oth
Sid
e(T
o p
reve
nt
rain
wat
er
fro
m o
the
r a
rea
to
Oil
Inte
rce
pto
r A
rea
)
Tra
in
To
Col
lec
tion
Su
mp
Pit
Deta
ilin
g
30
000
mm
(L
) x
50
00
mm
(W
)
VTSB Trading27
Ma
nh
ole
or
Re
levan
t
Au
tho
rity
's
Ad
vis
e
SE
CT
ION
VIE
W
Solid
Waste
Dra
in
(SW
D)
GP
T
Oil I
nte
rce
pto
r
(Fro
sco)
WA
ST
E W
AT
ER
RE
TE
NT
ION
PO
ND
(Ma
yb
e R
eq
uir
e t
o b
e P
retr
eate
d)
CO
VE
RE
D W
OR
K S
HO
P
(SE
RV
ICE
& M
AIN
TE
NA
NC
E)
FR
OS
CO
OIL
IN
TE
RC
EP
TO
R
GP
TG
PT
GP
T
Und
er
Sin
k O
il
Inte
rce
pto
r
GP
T
BU
S P
AR
KIN
G A
RE
A (
OP
EN
)
In k
eep
ing
wit
h o
ur
po
licy
of
up
dat
ing
pro
du
cts
we
res
erve
th
e ri
ght
To m
ake
imp
rove
men
ts o
r ch
ange
s w
ith
ou
t n
oti
ce.
SOLI
D
WA
STE
SUM
P P
IT
SOLI
DW
AST
ESU
MP
PIT
SOLI
D
WA
STE
SUM
P P
IT
SOLI
D
WA
STE
SUM
P P
IT
SOLI
D
WA
STE
SUM
P P
IT
VTSB Trading28
EXTERNAL OPEN AREA
FROSCO HF OIL INTERCEPTOR AND SOLID POLLUTANT STRAINER (BASKET) MODEL: FEO-600 (OCBV)-EP
VTSB Trading29
N.B. All Intellectual Property Rights Reserved
ENVIRONMENT QUALITY ACT 1974
SEWAGE AND INDUSTRIAL EFFLUENTS REGULATIONS
First ScheduleList of discharge to which these regulations do not apply :
1) Processing of oil-palm fresh fruit bunches into crude palm oil, whether as an intermediate or final product.2) Processing of natural rubber in technically specified from latex form including prevulcanized or the form of
modified and special purpose rubber, conventional sheet, skim, crepe or scrap rubber.3) Mining activities.4) Processing manufacturing, washing or servicing of any other products or goods :
• That produce effluent of less than 60 cubic meter ( 13,000 imperial gallons ) per day,• That the effluent of which does not contain those contaminants listed as parameters (vi) to (xvi) in the first
column of the Third Schedule,• Where the total load of biochemical oxygen demand of the effluent fixed at 20 degree Centigrade for 5 days
or suspended solid or both, shall not exceed 6 kilograms per day ( concentration 100 milligrams per liter),• In any housing or commercial development or both of less than 30 units, without affecting the generality of
the © above.
Second ScheduleStandard methods of Analysis of Effluent
1) “Standard Methods of examination of Water and Waste Water“ published jointly by the American Public HealthAssociation, an American Water Works Association and the Water Pollution Control Federation of the UnitedStates, or
2) “Analysis of Raw, Potable and Waste Waters“ published by the Department of the Environment of the UnitedKingdom.
Third ScheduleParameter Limit of Effluent of Standard A and B :
No PARAMETER UNITSTANDARD
A BI Temperature C 40 40ii pH Value - 6.0-9.0 5.5-9.0iii BOD at 20C mg/L 20 50iv COD mg/L 50 100v Suspended Solids mg/L 50 100vi Mercury mg/L 0.005 0.05vii Cadmium mg/L 0.01 0.02viii Chromium, Hexavalent mg/L 0.05 0.05ix Arsenic mg/L 0.05 0.10x Cyanide mg/L 0.05 0.10xi Lead mg/L 0.10 0.50xii Chromium, Trivalent mg/L 0.20 1.00xiii Copper mg/L 0.20 1.00xiv Manganese mg/L 0.20 1.00xv Nickel mg/L 0.20 1.00xvi Tin mg/L 0.20 1.00xvii Zinc mg/L 2.00 2.00Xviii Boron mg/L 1.00 4.00xix Iron (Fe) mg/L 1.00 5.00xx Phenol mg/L 0.001 1.00xxi Free Chlorine mg/L 1.00 2.00xxii Sulphide mg/L 0.50 0.50xxiii Oil and Grease mg/L Not Detected 10.00
VTSB Trading
31
Existing sewage treatment system (approved after January 1999)All sewerage treatment system which were approved after the Guidelines for Developers : SewerageTreatment Vol. IV, 2nd edition and were enforced by Department of Sewerage Services, Ministry of Housingand Local Government, beginning January 1999 and up to the date of coming into operation of theseregulations.
Note :Standard A is applicable to discharge into any inland waters within catchment areas listed in the ThirdSchedule, while Standard B is applicable to any other inland waters or Malaysian waters.
ENVIRONMENT QUALITY (SEWAGE)
REGULATIONS 2009
PARAMETER UNITSTANDARD
A B
(1) (2) (3) (4)
a) BOD5 at 20oC mg/L 20 50
b) COD mg/L 120 200
c) Suspended Solids mg/L 50 100
e) Oil and Grease mg/L 20 20
f) Ammoniacal Nitrogen mg/L 50 50
VTSB Trading32
Founded Year 1986
Over 38 years experience in the Building, Construction &
Property Industry
Pioneer of Biomatic Grease Interceptor System in Malaysia
Collaborated with SIRIM (Standard and Industrial
Research Institute of Malaysia) to conduct the 1st test
analysis on the Biomatic Grease Interceptor with the
highest efficiency result in Malaysia
Our own research, design & manufacturing facilities.
One stop center for developers, architects, design
engineers & contractors for their building materials needs
Long track record & excellent service by our team of
competent and capable technicians
We provide high technical expertise & advice
Consultancy & design for environmental protection
related projects
Some of the past projects we have participated & supplied
to :
KOMTAR, Georgetown, Penang
Kuala Lumpur International Airport (KLIA)
Petronas Twin Towers (KLCC)
Kuala Lumpur Tower
Sepang International Circuit (SIC), Formula 1 Racing
(F1)
National Palace, Duta Road, Kuala Lumpur, Malaysia
Port Klang Free Trade Zone
Mid Valley City, Kuala Lumpur, Malaysia
KTM (Keretapi Tanah Melayu, Malayan Railway)
National Double Tracking & Electrification Project.
www.froscoweb.com
COPYRIGHT VTSB Trading (149888-v)
GREYWATEC ENGINEERING SDN. BHD
In keeping with our policy of updating products we reserve the rightTo make improvements or changes without notice.
ASSOCIATED BRAND :
WELL ESTABLISHED BRANDS IN GREASE / OIL AND WASTE
WATER MANAGEMENT SYSTEM FOR THE PROJECTS IN
THE MARKET