MTC001 EMF Report COMMERCIAL IN CONFIDENCE Sat-Com (Pty) Ltd Original Company Registration Number: 91/415 Sat-Com House, No 2-6 Jakaranda Street, Suiderhof, Windhoek, Namibia P.O. Box 22951, Windhoek Tel +264 (0)61 374 700 Fax +264 (0)61 251 615 http://www.sat.com.na/ Electromagnetic Field Measurements and Predictive Report Date: 05 September 2012 Project Code: MTC001 – EMF Measurements Revision: 1.0 APPROVAL AUTHORITY NAME SIGNATURE DATE Sat-Com Reinhold Rothkegel 05 September 2012 Enviro Dynamics Eloise Carstens 11 September 2012 Non-Disclosure Protection Statement The information contained within this document is confidential in all respects and it is hereby acknowledged and agreed that the information as provided shall only be used for study and evaluation purposes. It is further agreed that the information furnished will not be used for any other purpose than stated above and that the information will not, either directly or indirectly, by agent, employee, or representative, be disclosed either in whole or in part, to any other third party; provided however that the information provided may be disclosed only to those directors, officers, employees, and advisors who need such information for the purpose of evaluation, it being understood that those directors, officers, employees and advisors shall be informed of the confidential nature of the information and shall be directed to treat the information confidentially

Upload: others

Post on 15-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • MTC001 EMF Report COMMERCIAL IN CONFIDENCE

    Sat-Com (Pty) Ltd Original Company Registration Number: 91/415 Sat-Com House, No 2-6 Jakaranda Street,

    Suiderhof, Windhoek, Namibia P.O. Box 22951, Windhoek Tel +264 (0)61 374 700

    Fax +264 (0)61 251 615

    http://www.sat.com.na/

    Electromagnetic Field Measurements and

    Predictive Report

    Date: 05 September 2012

    Project Code: MTC001 – EMF Measurements Revision: 1.0

    APPROVAL

    AUTHORITY NAME SIGNATURE DATE

    Sat-Com Reinhold Rothkegel 05 September 2012

    Enviro Dynamics Eloise Carstens 11 September 2012

    Non-Disclosure Protection Statement The information contained within this document is confidential in all respects and it is hereby acknowledged and agreed that the information as provided shall only be used for study and evaluation purposes. It is further agreed that the information furnished will not be used for any other purpose than stated above and that the information will not, either directly or indirectly, by agent, employee, or representative, be disclosed either in whole or in part, to any other third party; provided however that the information

    provided may be disclosed only to those directors, officers, employees, and advisors who need such information for the purpose of evaluation, it being understood that those directors, officers, employees and advisors shall be informed of the confidential nature of the information and shall be directed to treat the information confidentially

  • Created: 05 September 2012 Proprietary and Confidential

    Page 2 of 24

    Contents REPORT DOCUMENT REVISION HISTORY 6

    GLOSSARY OF TERMS AND ABBREVIATIONS 6

    Section A: EMF Measurement Report 1. INTRODUCTION 7 2. MEASURED RESULTS 7

    3. PHOTOS OF SELECTED MEASUREMENT POSITIONS: 13

    4. SUMMARY OF RESULTS AND CONCLUSION 15 5. INDEPENDENT ASSESSOR 15

    6. MEASUREMENT EQUIPMENT AND METHODOLOGY 15

    Section B: EMF Predictive Report 1. INTRODUCTION 16 2. BASE-STATION DETAILS 17

    3. CALCULATED RESULTS 19 4. TECHNICAL BACKGROUND 23

    5. REFERENCES 24

  • Created: 05 September 2012 Proprietary and Confidential

    Page 3 of 24

    List of Figures

    Section A: EMF Measurement Report Figure A 1 : Overview Map of sites where measurements were performed ........................................... 8

    Figure A 2 : Map of Area and Measurement Positions around the planned Mission Road ........................ 9 Figure A 3 : Map of Area and Measurement Positions around the planned Gloudina Road ...................... 9

    Figure A 4 : Map of Area and Measurement Positions around the planned Kwame Road Mini Base

    Station Site ............................................................................................................... 10 Figure A 5 : Map of Area and Measurement Positions around the planned Hebenstreit Base Station

    Site .......................................................................................................................... 10 Figure A 6 : Map of Area and Measurement Positions around the planned Reuning Base Station Site ..... 11

    Figure A 7 : Map of Area and Measurement Positions around Gevers Street Mobile Base Station Site ..... 11

    Section B: EMF Predictive Report Figure B 1 : Overview of installation ............................................................................................... 17 Figure B 2 : Overview of Site Locations .......................................................................................... 18

    Figure B 3 : Predicted RF Exposure levels 1.5m above ground level over a 500m x 500m area at Mission Road Mini site (including the position of expected highest RF exposure) ............... 20

    Figure B 4 : Predicted RF Exposure levels 1.5m above ground level over a 500m x 500m area at the

    Gloudina Road Mini site (including the position of expected highest RF exposure) ............. 20 Figure B 5 : Predicted RF Exposure levels 1.5m above ground level over a 500m x 500m area at the

    Kwame Road Mini site (including the position of expected highest RF exposure) ............... 21 Figure B 6 : Predicted RF Exposure levels 1.5m above ground level over a 500m x 500m area at the

    Hebenstreit site (including the position of expected highest RF exposure) ........................ 21

    Figure B 7 : Predicted RF Exposure levels 1.5m above ground level over a 500m x 500m area at the Reuning site (including the position of expected highest RF exposure) ............................. 22

    Figure B 8 : Predicted RF Exposure levels 1.5m above the level of expected maximum exposure of a multiple storey building near the Gloudina Road Mini site (including the position of

    expected highest RF exposure) ................................................................................... 22

  • Created: 05 September 2012 Proprietary and Confidential

    Page 4 of 24

    List of Tables

    Section A: EMF Measurement Report Table A 1 : RF Exposure Levels at Measurement Positions ................................................................. 12

    Section B: EMF Predictive Report Table B 1 : Antenna parameters used for the numerical prediction ..................................................... 18 Table B 2 : Predicted maximum exposure summary at 1.5m above ground level .................................. 19

  • Created: 05 September 2012 Proprietary and Confidential

    Page 5 of 24

    5 September 2012

    Enviro Dynamics

    16 Seder Street Suiderhof

    Windhoek Namibia

    To Whom It May Concern:

    ELECTROMAGNETIC FIELD EXPOSURE ASSESSMENT OF THE PROPOSED MTC POLE BASE STATION SITES

    (MISSION ROAD MINI, GLOUDINA ROAD MINI, KWAME ROAD MINI, HEBENSTREIT, REUNING) IN THE LUDWIGSDORF AND SURROUNDING AREAS

    Sat-Com PTY LTD and EMSS Consulting (EMSS) has expertise in the field of human exposure assessment to radio-frequency (RF) fields. For more than a decade we have focused our efforts in this area on the

    assessment of human exposure to cellular technologies.

    With the current available scientific knowledge, international regulating bodies have set guidelines for safe exposure to electromagnetic fields. The most widely accepted of these are the International Commission on Non-Ionizing Radiation Protection (or ICNIRP) guidelines.

    A number of independent international expert groups have also reviewed this scientific literature. All

    concluded that the balance of evidence indicates that exposure below the ICNIRP guidelines would not cause any negative health effects.

    Exposure predictions around the proposed installations were performed, using numerical simulations based on the site information supplied by MTC.

    The results obtained show that:

    1) The maximum expected RF exposure anywhere at 1.5m above ground level around all the

    proposed sites is at least 2300 times below the general public guidelines of limiting exposure

    proposed by ICNIRP.

    2) The maximum expected RF exposure at 1.5m above the level of expected maximum exposure of a multiple storey building near the Gloudina Road Mini base station is at least 450 times below the

    ICNIRP general public guidelines.

    3) According to the numerical EMF exposure assessment performed by Sat-Com and EMSS, the site is

    classified as Provisionally Compliant and will be Compliant with the ICNIRP Guidelines if the equipment is installed as specified in the planned documentation.

    Should the base station be constructed and switched on, Sat-Com and EMSS could verify that the installation is performed as in the information received from MTC before certifying the site in terms of the

    ICNIRP guidelines. Yours sincerely,

    ______________________ Reinhold Rothkegel Pr Eng.

    Sat-Com (PTY) LTD

  • Created: 05 September 2012 Proprietary and Confidential

    Page 6 of 24

    Report Document Revision History

    Revision No Revision Date Reason for Amendment

    1 5 September 2012 Initial Report

    Glossary of Terms and Abbreviations

    Term

    EMF Electromagnetic Fields

    EMSS EMSS Consulting (PTY) Ltd.

    Exclusion Zone

    Area around an antenna or antennas where the RF field values emanating from the antennas exceed the ICNIRP public guidelines (public exclusion zone) or the ICNIRP occupational

    guidelines (occupational exclusion zone)

    ICNIRP International Commission on Non-Ionizing Radiation Protection

    RF Radio-Frequency

    Sat-Com Sat-Com (PTY) Ltd

  • Created: 05 September 2012 Proprietary and Confidential

    Page 7 of 24

    Section A: EMF Measurement Report

    1. Introduction

    During a measurement survey commissioned by Enviro Dynamics, measurements were performed at and

    around the locations of five planned and one mobile base station sites of MTC in the Ludwigsdorf area,

    Windhoek. The aim of the survey was to measure the electromagnetic exposure levels at various positions

    around these sites.

    Measured results are compared to the guidelines of limiting exposure proposed by the International

    Commission on Non-Ionizing Radiation Protection (ICNIRP).

    The measurement protocol used is the IEC 62232 (May 2011) standard for determination of RF field

    strength and SAR in the vicinity of radio communication base stations for the purpose of evaluating human

    exposure.

    2. Measured Results Figure 1 to Figure 7 and Table 1 presents the measurement positions and exposure levels in terms of a

    percentage of the ICNIRP guidelines, where a 100% value would indicate that the safe exposure limit for

    the General Public has been reached. The cellular contribution to the total exposure is given in the last

    column of the table.

    Since the aim of the survey was to measure the typical exposure values, the reported results are un-

    extrapolated peak field instantaneous exposure results, at the specific date and time of the measurement

    survey.

    Measurements were performed around the position of the following six base station sites (five of which are

    planned base station sites and the remaining one an operational mobile base station):

    • Mission Road Mini, planned site to be located next to the south eastern boundary wall of 1 Herbst

    Street, on Dr. Kwame Nkrumah Avenue.

    • Gloudina Road Mini, planned site to be located alongside the Gloudina Pumpstation, at the corner

    of Babs and Joseph Mukwayu Ithana Streets.

    • Kwame Road Mini, planned site to be located next to the northern boundary wall of 70 Dr. Kwame

    Nkrumah Avenue.

    • Hebenstreit, planned site to be located on the corner of Hebenstreit and Wilemien Streets.

  • Created: 05 September 2012 Proprietary and Confidential

    Page 8 of 24

    • Reuning, planned site to be located along the northern boundary fence of the Lutheran Church on

    Reuning Street.

    • Gevers Street Mobile, operational mobile site currently located at the Maria municipal substation

    next to Belvedere Guest House on Dr. Kwame Nkrumah Avenue.

    Figure A 1 : Overview Map of sites where measurements were performed

  • Created: 05 September 2012 Proprietary and Confidential

    Page 9 of 24

    Figure A 2 : Map of Area and Measurement Positions around the planned Mission Road

    Mini Base Station Site

    Figure A 3 : Map of Area and Measurement Positions around the planned Gloudina Road

    Mini Base Station Site

  • Created: 05 September 2012 Proprietary and Confidential

    Page 10 of 24

    Figure A 4 : Map of Area and Measurement Positions around the planned Kwame Road Mini Base

    Station Site

    Figure A 5 : Map of Area and Measurement Positions around the planned Hebenstreit Base Station

    Site

  • Created: 05 September 2012 Proprietary and Confidential

    Page 11 of 24

    Figure A 6 : Map of Area and Measurement Positions around the planned Reuning Base Station Site

    Figure A 7 : Map of Area and Measurement Positions around Gevers Street Mobile Base Station Site

  • Created: 05 September 2012 Proprietary and Confidential

    Page 12 of 24

    Table A 1 : RF Exposure Levels at Measurement Positions

    Measured On

    No. Location Total Exposure

    Cellular Exposure

    4/08/2012

    11:37

    1 At the proposed position of the Mission Road

    Mini site.

    0.0025% 0.0002%

    14/08/2012

    11:48

    2 On the road in front of 52 Quenta Street. 0.0141% 0.0047%

    14/08/201 11:52

    3 On the driveway of 24 Dr. Kwame Nkrumah Avenue.

    0.0177% 0.0090%

    14/08/2012

    12:09

    4 In front of 2 Herbst Street at the end of the cul-de-

    sac.

    0.0036% 0.0010%

    14/08/2012

    12:33

    5 At the proposed position of the Gloudina Road

    Mini site.

    0.0027% 0.0004%

    14/08/2012 12:40

    6 In front of 1A Babs street. 0.0016% 0.0003%

    14/08/2012

    12:49

    7 On the driveway of the house on the corner of Olga

    and Portia streets, opposite 19 Portia Street.

    0.0119% 0.0028%

    14/08/2012

    12:54

    8 On the driveway of 39 Joseph Mukwayu Ithana

    Street.

    0.0072% 0.0008%

    14/08/2012 14:32

    9 At the proposed position of the Kwame Road Mini site.

    0.0042% 0.0008%

    14/08/2012

    14:38

    10 On the corner of Dr. Kwame Nkrumah Avenue

    and Jeanette Street.

    0.0030% 0.0016%

    14/08/2012

    14:43

    11 In front of 73 Dr. Kwame Nkrumah Avenue. 0.0049% 0.0029%

    14/08/2012 14:48

    12 Opposite the proposed position of the Kwame Road Mini site.

    0.0061% 0.0013%

    14/08/2012

    14:53

    13 At the gate of 68 Dr. Kwame Nkrumah Avenue. 0.0019% 0.0004%

    14/08/2012

    15:15

    14 At the proposed position of the Hebenstreit

    site.

    0.0091% 0.0047%

    14/08/2012 15:20

    15 In front of 45 Hebenstreit Street, close to the small gate.

    0.0094% 0.0059%

    14/08/2012

    15:26

    16 In front of 38 Hebenstreit Street 0.0106% 0.0036%

    14/08/2012

    15:32

    17 In the courtyard of the Square Park Shopping

    Centre, in front of the entrance to Hugo

    Scheepers Architects.

    0.0082% 0.0037%

    15/08/2012

    9:11

    18 At the proposed position of the Reuning site. 0.0020% 0.0005%

    15/08/2012 9:20

    19 Against the northeastern corner of the Lutheran Church building.

    0.0055% 0.0019%

    15/08/2012

    9:26

    20 In front of the gate of 11 Reuning Street. 0.0111% 0.0023%

    15/08/2012

    9:33

    21 On the driveway of 20 Reuning Street.

    0.0103% 0.0040%

    15/08/2012 11:00

    22 At the base of the Gevers Street Mobile site. 0.1483% 0.1407%

    15/08/2012

    11:07

    23 Next to the entrance gate to 89 Dr. Kwame

    Nkrumah Avenue Street.

    0.0318% 0.0240%

    5/08/2012 11:16

    24 Close to the Dr. Kwame Nkrumah Avenue entrance of the Belvedere Guesthouse.

    0.0698%

    0.0622%

    5/08/2012 11:36

    25 On the disabled parking, in front of the steps leading to the East Side Baptist Church entrance.

    0.0044%

    0.0030%

  • Created: 05 September 2012 Proprietary and Confidential

    Page 13 of 24

    3. Photos of selected measurement positions:

  • Created: 05 September 2012 Proprietary and Confidential

    Page 14 of 24

  • Created: 05 September 2012 Proprietary and Confidential

    Page 15 of 24

    4. Summary of Results and Conclusion Various positions around the Ludwigsdorf area, Windhoek, were surveyed and measurements were

    recorded at positions of maximum exposure in areas around the planned and mobile cellular base stations.

    For the measured results presented in this report a 100% value would indicate that the ICNIRP exposure

    limit for the General Public has been reached. The highest value measured is 0.1483% of the ICNIRP

    General Public guidelines and was obtained at position 22. This is more than 650 times below the General

    Population limit.

    5. Independent Assessor EMSS Consulting (EMSS) has expertise in the field of human exposure assessment to radio-frequency

    fields. Work performed includes site surveys, numerical predictions (computer simulations) and the

    interpretation and establishment of guidelines for limiting exposure. For more than a decade EMSS has

    focused its efforts in this area on the assessment of human exposure to cellphone technologies. These

    include measurements and numerical predictions of exposure to cellphones and base station antennas.

    EMSS publishes its research results in international peer-reviewed literature and has written numerous

    technical reports on base station site surveys performed on request from cellular operators and/or

    members of the public.

    6. Measurement Equipment and Methodology The survey meter and probes must be calibrated on a regular basis. The calibration status is presented in

    the following table.

    Survey

    Meter:

    Narda SRM 3006 Selective Radiation

    Meter, S/N: D-0058

    Calibration

    Status:

    Calibration valid until:

    17 September 2012

    Probe: Narda BN 3501/03 Three-Axis E-Field

    Probe, S/N: K-0238

    Calibration

    Status:

    Calibration valid until:

    25 August 2012

    A full uncertainty analysis for the measurement methodology used by Sat-Com and EMSS, as required by

    the IEC 62232 standard, has been performed and is available on request. Detailed information on the

    equipment specifications and the uncertainty assessment can be obtained on request.

    For more information, contact Sat-Com PTY Ltd at: Tel: (061) 374-700 (Reinhold Rothkegel)

    Email: [email protected]

  • Created: 05 September 2012 Proprietary and Confidential

    Page 16 of 24

    Section B: EMF Predictive Report

    1. Introduction

    In this section, numerical EMF exposure predictions are presented for the proposed MTC base-station sites

    in and around the Ludwigsdorf area. The aim of the numerical simulations is to establish if the proposed

    base-stations, if erected and switched on, would result in EMF exposure values such that International

    guidelines for limiting exposure to EMF are adhere to. Results are presented in terms of the International

    Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines [1], [2].

    The numerical technique employed for the predications are based on the CENELEC EN 50383 (2008) [3]

    and IEC 62232 (2011) [4] international standards for human exposure assessment in the vicinity of base

    stations antennas.

    Exposure predictions in a 500m x 500m area around each of the proposed MTC installations were

    performed, using numerical simulations based on the site information supplied by MTC.

    The results obtained show that:

    1. The maximum expected RF exposure anywhere at 1.5m above ground level around all the proposed sites

    is at least 2300 times below the general public guidelines of limiting exposure proposed by ICNIRP.

    2. The maximum expected RF exposure at 1.5m above the level of expected maximum exposure of a

    multiple storey building near the Gloudina Road Mini base station is at least 450 times below the ICNIRP

    general public guidelines.

    Although RF exposure levels below the international guidelines are predicted for all areas accessible to the

    general public around these sites, the following recommendation is made:

    1. As an extra precaution, on-site field measurements could be performed if each base-station is erected

    and switched on. The purpose of this would be to verify, through compliance measurements, the

    exposure levels predicted in this report.

  • Created: 05 September 2012 Proprietary and Confidential

    Page 17 of 24

    2. Base-Station Details

    These planned sites each consists of one camouflaged equipment container and a cellular antenna mounted

    at 9m on a pole, situated throughout the area of Ludwigsdorf, Windhoek.

    The height to the bottom of the antenna is 9m for each of the planned sites.

    Figure 1 shows an overview of the typical site model. Figure 2 shows on overview of the site locations.

    Figure B 1 : Overview of installation

  • Created: 05 September 2012 Proprietary and Confidential

    Page 18 of 24

    Figure B 2 : Overview of Site Locations

    The antenna parameters used for the numerical prediction are listed in Table 1 below.

    Table B 1 : Antenna parameters used for the numerical prediction

    Site

    Number

    Site Name Owner Antenna Type Frequency

    Band

    Electrical

    Tilt (°)

    Power

    Watt)

    1 Mission Road Mini MTC Kathrein 741790 UMTS2100 0 20

    2 Gloudina Road Mini MTC Kathrein 741790 UMTS2100 0 20

    3 Kwame Road Mini MTC Kathrein 741790 UMTS2100 0 20

    4 Hebenstreit MTC Kathrein 741790 UMTS2100 0 20

    5 Reuning MTC Kathrein 741790 UMTS2100 0 20

  • Created: 05 September 2012 Proprietary and Confidential

    Page 19 of 24

    3. Calculated Results

    The RF exposure levels were calculated 1.5m above the ground level of the area

    surrounding each of the proposed base stations, as well as at 1.5m above the level of

    expected maximum exposure of a multiple storey building near the proposed Gloudina

    Road Mini base station.

    Figure 3 to Figure 7 shows the RF exposure levels, for each of the proposed base-

    stations as a percentage of the ICNIRP general public guidelines at 1.5m above ground

    level over 500m x 500m areas near each base station. The positions of the expected

    highest RF exposure are indicated in each figure. Table 2 summarizes the predicted

    exposure for each proposed base-station as a percentage of the ICNIRP general public

    guidelines and as a multiple below these guidelines.

    Table B 2 : Predicted maximum exposure summary at 1.5m above ground level

    Site Name Percentage (%) of ICNIRP

    General Public guidelines

    Times below ICNIRP

    General Public guidelines

    Mission Road Mini 0.03474 2878

    Gloudina Road Mini 0.04241 2357

    Kwame Road Mini 0.03380 2958

    Hebenstreit 0.03492 2863

    Reuning 0.03329 3003

    Figure 8 shows the RF exposure levels, for each of the proposed base-stations as a

    percentage of the ICNIRP general public guidelines at 1.5m above the level of expected

    maximum exposure of a multiple storey building near the proposed Gloudina Road Mini

    base station. The position of the expected highest RF exposure is indicated in the figure.

    In this area, the predicted exposure is at least 450 times below the ICNIRP general public

    guidelines, or 0.2112% of these guidelines.

    The natural contour of the areas simulated was approximated with best effort. The hills in

    the area were approximated as uniform slopes to account for the rise in terrain.

  • Created: 05 September 2012 Proprietary and Confidential

    Page 20 of 24

    Figure B 3 : Predicted RF Exposure levels 1.5m above ground level over a 500m x 500m area at

    Mission Road Mini site (including the position of expected highest RF exposure)

    Figure B 4 : Predicted RF Exposure levels 1.5m above ground level over a 500m x 500m area at the

    Gloudina Road Mini site (including the position of expected highest RF exposure)

  • Created: 05 September 2012 Proprietary and Confidential

    Page 21 of 24

    Figure B 5 : Predicted RF Exposure levels 1.5m above ground level over a 500m x 500m area at the

    Kwame Road Mini site (including the position of expected highest RF exposure)

    Figure B 6 : Predicted RF Exposure levels 1.5m above ground level over a 500m x 500m area at the

    Hebenstreit site (including the position of expected highest RF exposure)

  • Created: 05 September 2012 Proprietary and Confidential

    Page 22 of 24

    Figure B 7 : Predicted RF Exposure levels 1.5m above ground level over a 500m x 500m area at the

    Reuning site (including the position of expected highest RF exposure)

    Figure B 8 : Predicted RF Exposure levels 1.5m above the level of expected maximum exposure of a

    multiple storey building near the Gloudina Road Mini site (including the position of expected highest RF exposure)

  • Created: 05 September 2012 Proprietary and Confidential

    Page 23 of 24

    4. Technical Background

    The site parameters used for the numerical predictions in this report are based on

    documentation supplied by MTC. Free-space propagation (radiation from the antennas

    into free-space, with no buildings, houses or any other structures included in the model)

    is also assumed. In reality, the RF exposure levels would drop considerably inside the

    building and houses (see reference [5]). More complicated models could be developed to

    quantify this drop in RF exposure levels. This would increase the accuracy of the

    predictions, but is beyond the scope of this document. The predictions assuming free-

    space propagation are conservative and should be sufficient for the investigation at hand.

    It can be concluded with confidence that, unless the installation of the antennas at the

    site is changed, the results in this document represent the expected “worst case”

    exposure conditions predicted at the site.

  • Created: 05 September 2012 Proprietary and Confidential

    Page 24 of 24

    5. References

    [1] “Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and

    Electromagnetic Fields (up to 300GHz),” ICNIRP (International Commission on Non-

    Ionizing Radiation Protection), April 1998.

    [2] ICNIRP Statement on the “Guidelines for Limiting Exposure to Time-Varying Electric,

    Magnetic, and Electromagnetic Fields (up to 300GHz),” Health Physics, Volume 97,

    Number 3, September 2009.

    [3] “Basic standard for the calculation and measurement of human exposure to

    electromagnetic fields from radio base stations and fixed terminal stations for

    wireless telecommunication systems (110 MHz – 40 GHz),” CENELEC EN 50383,

    March 2008.

    [4] “Determination of RF field strength and SAR in the vicinity of radiocommunication

    base stations for the purpose of evaluating human exposure,” IEC 62232, Edition

    1.0, May 2011

    [5] “On the Propagation of RF into a Building Constructed of Cinder Block Over the

    Frequency Range 200 MHz to 3 GHz,” C.D. Taylor, S.J. Gutierrez, S.L. Langdon, and

    K.L. Murphy. IEEE Trans. On Electromagnetic Compatibility, Vol. 41, No. 1, February

    1999.