en nac-3000 terminal installation guide

18

Upload: carlos-javier

Post on 04-Apr-2015

432 views

Category:

Documents


12 download

TRANSCRIPT

Page 1: En NAC-3000 Terminal Installation Guide
Page 2: En NAC-3000 Terminal Installation Guide

- 2 -

ⓒ Copyright 2003, NITGEN Co., Ltd. All rights reserved

To Contact UsTo Contact UsTo Contact UsTo Contact Us

Tel. 82-2-3415-1800

Fax. 82-2-3415-1601

E-mail : [email protected]

URL : http://www.nitgen.com

Features and specifications are subject to change without notice. Nopart of this guide may be copied or reproduced for any purpose withoutthe prior written authorization from NITGEN. NITGEN holds the copyright on the brands NITGEN and NITGEN logo.

Page 3: En NAC-3000 Terminal Installation Guide

- 3 -

Table of Contents 1. Before Installation

1.1 To install ----------------------------------------------------------- 4 1.2 Product package ------------------------------------------------ 4

2. Installation Environment ---------------------------------------------- 6 3. System Configuration

3.1 Network mode ----------------------------------------------------- 7 3.2 Standalone mode ------------------------------------------------- 8

4. Installation 4.1 Fastening the auxiliary plate ---------------------------------- 9 4.2 Attaching other devices except the terminal -------------- 10 4.3 Connecting external cables ----------------------------------- 11 4.4 Fastening the terminal ----------------------------------------- 12

5. Check After Installation ---------------------------------------------- 18

Page 4: En NAC-3000 Terminal Installation Guide

- 4 -

1. Before Installation 1.1 To install

Please follow the installation guide because the performance can be decreased if the product is installed incorrectly.

1.2 Product package

Product Pictures Qty Use Terminal

1ea Access Controller

Adapter

1ea

Power cord

1ea

Supplying power for the

terminal

Bracket

1ea Fastening the terminal

Page 5: En NAC-3000 Terminal Installation Guide

- 5 -

2ea Fastening the terminal Bolt

5ea Fastening the bracket

Housing

1ea

Receptacle

6ea

Connecting door cable

Housing & Receptacle & Cable

1ea

Connecting interphone

cable

S/W CD 1ea

Page 6: En NAC-3000 Terminal Installation Guide

- 6 -

2. Installation Environment

Please keep in mind the following conditions when you install the product. You might need to obtain the user's consent if necessary. ① This product is originally designed to install indoors. If you

have to install it outdoors, however, do not expose the terminal to direct sunlight, snow or rain.

② The connection cables should not be exposed outside, and it is highly recommended to bury them underground. If that is impossible, you must obtain the user's consent before installation.

③ Power supply should begin after all connections are completed. Do not disconnect the lines or make any additional connections while the power is supplied.

④ If you install the product as an access controller at a proper height for the users and in a near place that facilitates control of the entrance, you can use it more efficiently.

⑤ The power requirement for the system is AC 100~240V, 50/60Hz.

Page 7: En NAC-3000 Terminal Installation Guide

- 7 -

3. System Configuration 3.1 Network mode

Terminals are connected by network and it can be remote control.

Network (TCP/IP)

Server PC Client PC

Terminal

Locking Device

Door Open S/WInterphone

Page 8: En NAC-3000 Terminal Installation Guide

- 8 -

3.2 Standalone mode One terminal is used independently. All settings such as user registration, deletion, and access control are performed in the terminal alone.

Locking Device

Door Open S/W

Interphone

Page 9: En NAC-3000 Terminal Installation Guide

- 9 -

4. Installation ☞ The overall installation procedure is as follows: ①Fasten the bracket ②Attach other devices except terminal(locking device, interphone,

etc.) ③Connect the external cables ④Fasten the terminal 4.1 Fastening the auxiliary plate

① Decide where you want to install the product with the bracket and make 2 holes (ΦΦΦΦ30) for cable insertion to the wall as shown in the shaded area in [Figure 1].

② Align the bracket with the holes and fasten it with 5 bolts ([Figure 1]- ⓐⓑⓓⓔⓕ).

③ If there are extra holes for fastening, you can use ⓒ and ⓔ in [Figure 1].

[Figure 1][Figure 1][Figure 1][Figure 1]

d

e

f

a

c

b

Page 10: En NAC-3000 Terminal Installation Guide

- 10 -

4.2 Attaching other devices except terminal ☞ You can attach the following devices. Refer to the specifications

of each device for more information on installation. ①interphone ②Locking device ③Door Open button ■■■■ Types of installable locking devices and specifications

Type Specifications Remarks Deadbolt input: DC12V,

1A or lower Voltage output, Fail Safe/Secure

Electronic Magnetic-Lock

input: DC12V, 1A or lower

Voltage output, Fail Safe/Secure

Electric Strike input: DC12V, 1A or lower

Voltage output, Fail Safe/Secure

Auto Door *Maximum Switching

Voltage:220V DC,250V AC.

* Maximum Switching Current:

2A DC,AC or lower

Contact output

☞Fail Safe Type: UNLOCKED, Open Type on Emergency ☞Fail Secure Type: LOCKED, Close Type on Emergency

Page 11: En NAC-3000 Terminal Installation Guide

- 11 -

4.3 Connecting the external cables ☞ You should connect the following external cables.

But you don't have to install the interphone and network cables if the customer doesn't request them.

①Interphone cable (ⓐ in Figure 2) ②Door control cable (ⓑin Figure 2) ③Network cable (ⓓin Figure 2) ④Power cable (ⓒin Figure 2) 4.3.1 Connecting the interphone cable (J6)

Schematic Housing Receptacle Cable

PIN NO. Feature 1 INTER_2

51021-0200 50058-8000 UL1007, 28AWG 2 INTER_1

☞ When connecting the cable to the connector, please pay attention

to the terminal numbers.

J16

J6

J5

RJ 45

J14

[Figure 2][Figure 2][Figure 2][Figure 2]

Page 12: En NAC-3000 Terminal Installation Guide

- 12 -

Interphone Door Open S/W

Interphone

Door Open Button

INTER2

INTER1

Common

Door Monitor

GND

Door Open

Contact_B

Contact_A

Page 13: En NAC-3000 Terminal Installation Guide

- 13 -

4.3.2 Connecting the door control cable (J5) ■■■■ Specifications of the cable and material

Housing Receptacle Cable 5264-06 5263PBT UL1007, 22AWG

☞ Connection Note ①Pay attention to terminal numbers when connecting the cable to

the connector. ②Contact output is used when installing on the auto door. So make

sure to set the terminal [JP3] as OPEN. The factory default of the terminal [JP3] is JUMPER.

③Some locking devices may not have door monitoring signals. ■■■■ How to connect cables by types of locking devices

Common

Contact_B

GND

Door Monitor

Door Open

Contact_A

Door Open

Power(Fail

Door Monitoring

Deadbolt

Power(Fail

Strike EM Lock

Page 14: En NAC-3000 Terminal Installation Guide

- 14 -

Deadbolt/Strike/Electronic Magnetic-Lock PIN NO.

Feature Fail

Safe Type

Fail

Secure

Type

Door

Monitoring

Door

Open

1 GND GND GND Open

button

2 Door Open button Open

button

3 Door Monitoring Monitor (12/24V)

4 CONTACT_B VCC(12V) 5 COMMON 6 CONTACT_A VCC(12V)

Auto Door

PIN NO.

Feature Normal

Open

Normal

Close

Door

Monitoring

Door

Open

1 GND GND Open

button

2 Door Open button Open

button

3 Door Monitoring Monitor (12/24V)

4 CONTACT_B Contact 5 COMMON Contact Contact 6 CONTACT_A Contact

Page 15: En NAC-3000 Terminal Installation Guide

- 15 -

4.3.3 Connecting the network cable (J14) ① If there's no connector for the network cable, connect as

follows (pay attention to PIN numbers):

Schematic Housing Cable

PIN No Feature 1 TXP 2 TXN 3 RXP

RJ45, 8PIN UTP

6 RXN

② After you finish the above connection, use the [Network Connection Cable] to connect to the connector [J14] (ⓓ in Figure 2).

4.3.4 Connecting the power cable (J16)

Connect the DC cable of the adaptor to the connector [J16].

Page 16: En NAC-3000 Terminal Installation Guide

- 16 -

[Figure 3][Figure 3][Figure 3][Figure 3]

4.4 Fastening the terminal

① As shown in [Figure 3], insert the grooves of the terminal into two hooks of the fastened bracket.

Page 17: En NAC-3000 Terminal Installation Guide

- 17 -

② As shown in [Figure 4], use 2 bolts to fasten the terminal to

the bracket.

[Figure 4][Figure 4][Figure 4][Figure 4]

Page 18: En NAC-3000 Terminal Installation Guide

- 18 -

5. Check After Installation

When you finish the installation of the entire system, check if it is installed correctly before supplying power. Check if locking device and other devices work normally as the following order. For more information, please refer to "NAC-3000 Terminal User Manual" and "NAC-3000 Software User Manual". ① When power is supplied, the initial screen with NITGEN logo

will appear. ② Press the menu button to choose System Option > Terminal

Mode and check if the terminal is in SO mode. ③ Choose User Manager from the menu and then register user

ID and fingerprint. (By default, user ID is set to 4 digits long.) ④ Test the devices (including locking device) attached to the

terminal by performing fingerprint authentication. ⑤ If there's no problem, delete the fingerprint you registered for

the test.

If you manage terminals via the network after installation, proceed the following test:

① Install the program on a server PC for manager registration

and initial settings. ② Set the terminal mode to NL or NS from the terminal menu. ③ Set the network environment from the terminal menu. ④ Run Remote Manager to check the terminal connection and

then register it. ⑤ In the server PC, register a terminal user and check if the

authentication is performed normally. ⑥⑥⑥⑥ If there's no problem, delete both server and terminal users.