  • 7/28/2019 Endoscopy Leaflet -Amended Copyv3 (2)27.06

    1/4

  • 7/28/2019 Endoscopy Leaflet -Amended Copyv3 (2)27.06

    2/4

    W hitewater are specialists in the provision of purifiedwater systemsfor critical healthcare applications, includingendoscopy, haemodialysis, sterile services, clinical chemicalanalysers, laboratory and pathology.

    We are the largest supplier of endoscopy water systemsinIreland, providing purified water for disinfection and finalrinse to automated endoscope reprocessors(A ERs) .

    Designed to meet HSE Code of Practice for Decontamination

    of RIMD and HTM 2030

    Mediwater Endoscopy Fully Automatic ValidatedHot Disinfection Programme

    D econtamination Department, A ltnagelvin H ospital,

    Complete Service Capability

    We understand that ongoing validation and service supportis an essential requirement and ensure your critical pathequipment ismaintained on a regular, preventative basisto achieve maximum system reliability, cost effective andconsistent operation and technical compliance.

    O ur highly trained support team of service techniciansprovide an unrivalled service.

    Through this extensive level of resource, we offer acomprehensive range of service contracts, including our

    and guaranteed service levelagreementsto the majority of Irish hospitalsandprivate healthcare institutes.

    24 / 7 on-call support

    User Friendly Maintenance

    M aintenance on the M ediwater Endoscopy unit is easy.

    A ll consumablesare easily replaced, and directly accessible.

    Total maintenance accessibility iscompleted by lift-off

    panelsfor all round access.

    Trending and Data Analysis

    M ediwater Endoscopy providesRS232 portsfor chartrecorder / printer hook up to make a permanent archiveof historic and real time data or for BM S interface.

    *

    Ensuresconsistent compliance with endotoxin and TVCrequirements.

    N o chemicalsare used: no chemical handling no chemical storage no chemical compatibility issues no chemical disposal.

    Lower operating coststhan chemical.

    M imicsthe thermal disinfection cycle of the endoscopewasher to provide consistently secure water source.

    Fully automatic control for daily thermal disinfection

    The Mediwater Endoscopy unit isdesigned for ease ofuse by hospital staff and incorporatesstate of the art

    thermal disinfection.

  • 7/28/2019 Endoscopy Leaflet -Amended Copyv3 (2)27.06

    3/4

    70 LitrePurifiedWaterTank

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    ClassA air break tank on feedwater supply

    H igh efficiency reverse osmosis membrane

    Integral 70 ltr PW ** water reservoir with bacterial vent

    filter to ensure microbiological integrity

    Re-circulation pump provides instantaneousdelivery flow

    O peratesquietly at very low noise levels

    Ultra-violet steriliser for continual bacteria destruction

    and maintenance of low microbiological levels

    Ultrafiltration membrane providesfinal security against

    microbiological and particulate contamination

    Comprehensive micro- processor monitoring and control

    system

    A septic sample point to validate and verify product water

    quality

    Complete range of alarm systems which alert user to

    critical parameters

    A utomatic fully programmable HO T disinfection

    programme

    !

    !

    !

    !

    !

    !

    !

    !

    !

    !

    Mediwater Endoscopy Fully Automatic ValidatedHot Disinfection Programme

    Features and benefits

    #24 / 7 on-call support.For clientswho take out 12 monthservice contractsand whose systemsare regularly maintained, we

    offer a 24 hour emergency on-call service by the largest team of

    qualified and experienced engineers in Ireland.

    AutomaticDumpValve

    InlineHeater

    *

    Disinfection

  • 7/28/2019 Endoscopy Leaflet -Amended Copyv3 (2)27.06

    4/4

    1970 197074040

    180 21027040

    66060

    ISO 9001:2000 Q uality A ssured F rm

    2 Inch Stand Pipe Suitable for 85C