enhanced force feed lubrication system · pump connections are in different locations to use the...
TRANSCRIPT
-
Enhanced Force Feed Lubrication System• Increased reliability• Ease of maintenance• Robust component design• Improved protection and diagnostics• Enhanced pump priming • Fewer connection points• Easily interchangeable
ARIEL CORPORATION
35 Blackjack Road Mount Vernon, OH 43050 www.arielcorp.com
WORLD STANDARD COMPRESSORS
Genuine Ariel Parts are available through our worldwide network of authorized distributors.
-
Increased selection of ATEX certified no-flow monitoring devices to meet your needs.
No-Flow Monitoring Devices
Now available as a new unit option or aftermarket addition to simplify troubleshooting.
Resettable Pin Indicators
Improved manufacturing techniques reduce leakage at threaded connections and prevent thread damage.
Divider Block Baseplates and Discharge Check Valve Threads
Redesigned pump assembly improves pump priming, reduces rolling resistance on the camshaft, prevents water intrusion into the lubricator box and minimizes connection leakage.
Force Feed Lubricator PumpPressure gauges
installed on each balance valve eases adjustment and maintenance on KBU:Z:B:V units.
Balance Valves
Redesigned with increased accuracy to avoid nuisance unit shut downs.
Rupture Discs
Improved design offers better performance and quicker priming. Reduction in size and weight minimizes the effects of vibration and keeps components out of the way.
Oil Traps
Old style
New style
Ariel Response Center | Phone: (888) 397-7766 (Option 1) | Fax: (740) 397-1060 | [email protected]
One check valve with fewer fittings and potential leak points is now used for all pressure ranges. Reduction in size and weight minimizes the effects of vibration for increased reliability.
Injection Check Valves
Old style
New style
Ariel Spare Parts | Phone: (888) 397-7766 (Option 2) | Fax: (740) 397-5054 | [email protected]
Enhanced Force Feed Lubrication System
Increased Reliability and Ease of MaintenanceIntroducing the improved high pressure force feed lubrication system from Ariel. Improvements will be provided on new units and available as aftermarket upgrades beginning January 2012.
Tube connections replace threaded connections to reduce fitting leakage, ease gauge face alignment and eliminate damage from over-tightening. Gauges have been repositioned below divider blocks for increased protection where possible.
Pressure Gauges
Old style
New style
-
Resettable Pin IndicatorBlow-out Assembly
Rupture Disc
REPLACEMENT RUPTURE DISCBLOW-OUTFITTING
ArielP/N
A-0080A-3531A-3532A-3533A-3534A-3535
PT0200CB
PT0201CD
1/4 x 0.035wall
(6.4 x 0.9)
1/4 x 0.065wall
(6.4 x 1.7)
A-0124A-3536A-3537A-3538A-3539A-3540
ArielP/N
ArielP/N
A-18243
A-9968
A-9969
ArielP/N
Purple
Yellow
Red
Orange
Pink
Blue
ColorSize
in. (mm)
3250 (224)3700 (255)4600 (317)5500 (379)6400 (441)7300 (503)
Ratingpsig (bar g)
3000 (207)
3500 (241)
5000 (345)
Ratingpsig (bar g)
STAINLESS STEEL TUBING
Pin indicators are sized according to rupture disc size.
RESETTABLE PIN INDICATOR
A-17776-A
B
1/4” NPT - Oil Trap & Check Valve Assy
A-18526-A
Check Valve
A-18527-A
A Oil Trap Body
C 1/8” NPT StemDependant on Port Size
A-17776
A-18496
A-17775
A-17774
1/4” NPT Stem
A-17775-A 1/8” NPT - Oil Trap & Check Valve Assy
A-9477A-9478
A-9476Old P/N New P/N Description
A-18525-A 3/16” Ariel Pump
3/8” Ariel Pump1/4” Ariel PumpA-3189 A-18451-A
A-8728 A-17257-AA-8727 A-17256-A
A-9093 A-17258-A
A-0261Old P/N New P/N Description
A-18450-A Gauge, 100psi, Bottom Mount, 3/8” T
Gauge, 3000psi, Back Mount, 3/8” TGauge, 100psi, Back Mount, 3/8” T
Gauge, 5000psi, Back Mount, 3/8” TGauge, 7500psi, Back Mount, 3/8” T
Complete Assembly
Individual Components
Ariel encourages system conversions to take advantage of these improvements. Please note, after a phase-out period, Ariel will no longer offer the previous style of lubrication system components.Reference Ariel Customer Technical Bulletin 218 for additional details on system improvements, conversions and part numbers.
Replacing existing components will require
(~3”) to account for shorter check valve.
tube unions in toolboxes for conversions.
To maximize the benefits of the new components we advise converting to the new oil traps and check valves at the same time.
needed to adapt the new tube style connector to existing threaded connection.
Pump connections are in different locations
to use the new pump in existing systems.
Resettable Pin Indicator Sizing
Oil Trap & Check Valve
Gauges Pumps
Injection Check Valve
A-18496
1/8” NPT Connection
AOil Trap
CB
Newly available option with no interchangeability impact.
Pin indicator pressure should not exceed the rupture disc pressure protecting the system.
Contact the ARC forassistance selectingpin indicators.
Enhanced Force Feed Lubrication System | Quick Reference Guide
New Part Numbers & Interchangeability Impact
02/2012
ARIEL CORPORATIONAriel Response Center | P: (888) 397-7766 (Option 1) | [email protected]
Ariel Spare Parts | P: (888) 397-7766 (Option 2) | [email protected]
Genuine Ariel Parts are available through our worldwide network of authorized distributors.
A-19078