essential lighting wiring guide - control4 · 3 3-way load - light - line (light between line and...

4
1 1 Control4® Essential Lighting Wiring Guide SCREW TERMINALS ON ESSENTIAL LIGHTING PRODUCTS Control4 Essential Lighting products feature convenient dual quick-connect holes and screw terminals with the ability to daisy-chain devices for convenient installation. Important wiring information Essential Lighting products are only rated for use with copper wire. Use 14 AWG or larger wires suitable for at least 80 °C To use the quick-connect holes, strip 5/8" (16 mm) of insulation from the wires. To use the screw terminals, strip 1" (25 mm) of insulation from the wires. Wiring examples SWITCH-LEG CONFIGURATION This diagrams shows a sample wiring configuration using an Essential Forward Phase Dimmer (C4-V-FPD120) in a switch-leg (no neutral in the wallbox) situation. Switch-leg (no neutral) Note: The Essential Forward Phase Dimmer does not support an Auxiliary Keypad when installed in a switch-leg configuration. Note: The Essential Switch does not support switch-leg configuration. Switch-leg dimmer (Forward Phase Dimmer) Load Line Ground Neutral Light (load) From breaker box WIRING LEGEND Black Red Gray Green Blue Red/ White Important! Wiring colors in these diagrams are representative and will vary depending on your installation. Line voltage Load (to light) Neutral Earth ground Traveler Load/neutral (switch-leg) ESSENTIAL FORWARD PHASE DIMMER ESSENTIAL SWITCH ESSENTIAL AUXILIARY KEYPAD

Upload: others

Post on 31-May-2020

4 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Essential Lighting Wiring Guide - Control4 · 3 3-way Load - Light - Line (Light between Line and Load switch locations) 4-WAY CONFIGURATION WITH ESSENTIAL AUXILIARY KEYPADS This

11

Control4® Essential Lighting Wiring GuideSCREW TERMINALS ON ESSENTIAL LIGHTING PRODUCTSControl4 Essential Lighting products feature convenient dual quick-connect holes and screw terminals with the ability to daisy-chain devices for convenient installation.

Important wiring information

• Essential Lighting products are only rated for use with copper wire.• Use 14 AWG or larger wires suitable for at least 80 °C• To use the quick-connect holes, strip 5/8" (16 mm) of insulation from the

wires.• To use the screw terminals, strip 1" (25 mm) of insulation from the wires.

Wiring examplesSWITCH-LEG CONFIGURATIONThis diagrams shows a sample wiring configuration using an Essential Forward Phase Dimmer (C4-V-FPD120) in a switch-leg (no neutral in the wallbox) situation.

Switch-leg (no neutral)

Note: The Essential Forward Phase Dimmer does not support an Auxiliary Keypad when installed in a switch-leg configuration.

Note: The Essential Switch does not support switch-leg configuration.

Switch-leg dimmer(Forward Phase Dimmer)

Load

Line

Ground

NeutralLight (load)

From breaker box

WIRING LEGENDBlack

Red

Gray

Green

Blue

Red/ White

Important! Wiring colors in these diagrams are representative and will vary depending on your installation.

Line voltage

Load (to light)

Neutral

Earth ground

Traveler

Load/neutral (switch-leg)

ESSENTIAL FORWARD PHASE DIMMER ESSENTIAL SWITCH ESSENTIAL AUXILIARY KEYPAD

Page 2: Essential Lighting Wiring Guide - Control4 · 3 3-way Load - Light - Line (Light between Line and Load switch locations) 4-WAY CONFIGURATION WITH ESSENTIAL AUXILIARY KEYPADS This

2

3-WAY CONFIGURATIONS WITH AN ESSENTIAL AUXILIARY KEYPADThese diagrams show sample 3-way wiring configurations using an Essential Forward Phase Dimmer (C4-V-FPD120) or Switch (C4-V-SW120-277) with one Essential Auxiliary Keypad (C4-V-AUX).

3-way Line - Load - Light (Dimmer at line switch location)

3-way Line - Load - Light (Dimmer at load switch location)

Out to load switch

From breaker box

Line Switch(Forward Phase Dimmer or Switch)

Load Switch(Auxiliary Keypad)

Load

Line

Ground

Traveler

Neutral

Ground

TravelerNeutral

Out to light (load)

Out to line switch

From breaker box

Load Switch(Forward Phase Dimmer or Switch)

Line Switch(Auxiliary Keypad)

Load

Line

Ground

Traveler

Neutral

Ground

TravelerNeutral

Out to light (load)

Page 3: Essential Lighting Wiring Guide - Control4 · 3 3-way Load - Light - Line (Light between Line and Load switch locations) 4-WAY CONFIGURATION WITH ESSENTIAL AUXILIARY KEYPADS This

3

3-way Load - Light - Line (Light between Line and Load switch locations)

4-WAY CONFIGURATION WITH ESSENTIAL AUXILIARY KEYPADSThis diagram shows a sample 4-way wiring configuration using an Essential Forward Phase Dimmer (C4-V-FPD120) or Switch (C4-V-SW120-277) with two Essential Auxiliary Keypads (C4-V-AUX). Daisy-chain each additional Auxiliary Keypad by extending the Ground, Traveler, and Neutral to each keypad.

4-way configuration

Note: The Essential Forward Phase Dimmer and Switch support up to five Auxiliary Keypads, daisy-chained as shown above in 3-, 4-, 5-, or 6-way wiring configurations.

Note: Each Essential Auxiliary Keypad can be up to 100 m (300 ft) from the dimmer, switch, or another keypad. Total distance from the dimmer or switch to all the connected keypads can be up to 300 m (1000 ft).

From breaker box

Load Switch(Forward Phase Dimmer or Switch)

Line Switch(Auxiliary Keypad)

Load

Line

Ground

Traveler

Neutral

Ground

TravelerNeutral

Out to light (load)

Light (load)

Out to line switch

From breaker box

Load Switch(Forward Phase Dimmer or Switch)

Line Switch(Auxiliary Keypad)

Load

Line

Ground

Traveler

Neutral

Ground

TravelerNeutral

Out to light (load) Out to line switch

Line Switch(Auxiliary Keypad)

Ground

TravelerNeutral

Page 4: Essential Lighting Wiring Guide - Control4 · 3 3-way Load - Light - Line (Light between Line and Load switch locations) 4-WAY CONFIGURATION WITH ESSENTIAL AUXILIARY KEYPADS This

4

MULTI-GANG BOX WIRING EXAMPLEThis diagram shows a sample multi-gang box configuration with an additional 3-way location using mutliple Essential Forward Phase Dimmers (C4-V-FPD120) or Switches (C4-V-SW120-277) and an Essential Auxiliary Keypad (C4-V-AUX).

Tip: Use the two quick-connect terminals to daisy-chain your wiring to save clutter in a multi-gang box installation. For example, take ground into each dimmer and then out to each light.

Three-gang box with one 3-way

Regulatory/Safety informationTo review regulatory information for your particular Control4 products, see the information located on the Control4 website at ctrl4.co/reg.

WarrantyVisit ctrl4.co/warranty for details.

More informationMore information on Essential Lighting products can be found on our website or in the Dealer Portal. Open the URL below or scan the QR code.

From breaker box

Forward Phase Dimmer or Switch

Load

Ground

Neutral

Out to light (load)Out to line switch

Auxiliary Keypad

Ground

TravelerNeutral

Load

Ground

NeutralLine

Line

Load

Ground

Neutral

Traveler

Line

Forward Phase Dimmer or Switch

Forward Phase Dimmer or Switch

ESSENTIAL LIGHTING HELP

ctrl4.co/essential-wiring

ESSENTIAL LIGHTING PRODUCTS

ctrl4.co/essential-lighting

Copyright ©2020, Wirepath Home Systems, LLC. All rights reserved. Control4 and Snap AV and their respective logos are registered trademarks or trademarks of Wirepath Home Systems, LLC, dba “Control4” and/or dba “SnapAV” in the United States and/or other countries. 4Store, 4Sight, Control4 My Home, Snap AV, and Wirepath are also registered trademarks or trademarks of Wirepath Home Systems, LLC. Other names and brands may be claimed as the property of their respective owners. All specifications subject to change without notice.