WALL TYPE LEGEND
TYPE: DESIGN: CONSTRUCTION:
1
EXTERIOR WALL:
WALL TYPE 1:
2A
INT. FIN (COORDINATE W/ RM. FIN.
SCH.'S).
NEW 16mm IMPACT RESISTANT GYPSUM WALL
BOARD
NEW SEALED VAPOUR BARRIER
NEW 140mm MINERAL WOOL INSULATION (24)
EX. WOOD STUD FRAMING (2x6)
EX. EXTERIOR SHEATHING
NEW 50mm SEMI RIGID MINERAL WOOL
CAVITY INSULATION. (R10)
NEW 51mm HOR. METAL Z-GIRTS @600mmO.C.
NEW TYVEK MEMBRANE
NEW 25mm VERTICAL METAL FURRING @
600mm O.C..
NEW PRE-FIN. METAL SIDING
EXTERIOR WALL:
WALL TYPE 2A:
25 16140
16
5016
INT. FIN (COORDINATE W/ RM. FIN.
SCH.'S).
NEW 16mm IMPACT RESISTANT GYPSUM
WALL BOARD
NEW SEALED VAPOUR BARRIER
NEW 140mm MINERAL WOOL INSULATION
(24)
EX. WOOD STUD FRAMING (2x6)
EX. EXTERIOR SHEATHING
NEW 50mm SEMI RIGID MINERAL WOOL
CAVITY INSULATION. (R10)
NEW 51mm HOR. METAL Z-GIRTS @
600mmO.C.
NEW TYVEK MEMBRANE
NEW 25mm VERTICAL WOOD FURRING @
600mm O.C..
NEW PRE-FIN. WOOD SIDING.
EXTERIOR WALL:
WALL TYPE 2B:
INT. FIN (COORDINATE W/ RM. FIN.
SCH.'S).
NEW 16mm IMPACT RESISTANT GYPSUM
WALL BOARD
NEW SEALED VAPOUR BARRIER
NEW 140mm MINERAL WOOL INSULATION
(24)
EX. WOOD STUD FRAMING (2x6)
EX. EXTERIOR SHEATHING
NEW 50mm SEMI RIGID MINERAL WOOL
CAVITY INSULATION. (R10)
NEW 51mm HOR. METAL Z-GIRTS @
600mmO.C.
NEW TYVEK MEMBRANE
NEW 25mm VERTICAL METAL FURRING @
600mm O.C..
NEW ACM PANEL.
EXTERIOR WALL:
WALL TYPE 2C:
INT. FIN (COORDINATE W/ RM. FIN.
SCH.'S).
16MM GYP. BD.
140MM WOOD STUD, CAVITY FILLED WITH
SOUND ATTENUATION BATT INSULATION.
16MM GYP. BD.
INT. FIN. (COORDINATE W/ RM. FIN.
SCH.'S).
INTERIOR PARTITION:
WALL TYPE 3A:
16 16
INTERIOR PARTITION:
WALL TYPE 3B:
3C
INTERIOR PARTITION:
WALL TYPE 3C:
2A
2B 2B
2C 2C
WALL TYPE LEGEND
TYPE: DESIGN: CONSTRUCTION:
ROOF TYPE LEGEND
TYPE: DESIGN: CONSTRUCTION:
REMOVE EXISTING ROOFING DOWN TO ROOF
EXISTING SHEATHING
NEW METAL ROOFING SYSTEM AS SPEC'D
NEW HIGH TEMP UNDERLAYMENT MEMBRANE
EXISTING OSB SHEATHING
EXISTING WOOD TRUSSES (REFER TO STRUCTURAL)
NEW R60 BLOWN CELLULOSE INSULATION
NEW VAPOUR BARRIER
NEW 13mm METAL FURRING CHANNEL @
400mm O/C
NEW 16mm GYPSUM BOARD
NEW PRIMER & PAINT
ROOF TYPE R1B:
92MM METAL STUD SPACED AT 600 O/C
22MM FURRING CHANNEL RUNNING
PERPENDICULAR TO STUDS @ 600 O/C
16MM GYP. BD.
INT. FIN PAINT COLOUR TO BE
SELECTED BY ARCHITECT
CEILING TYPE C1:C1
FLOOR TYPE LEGEND
TYPE: DESIGN: CONSTRUCTION:
F1
150MM CONCRETE SLAB
75MM RIGID INSULATION
VAPOUR BARRIER MEMBRANE TURNED
UP AT SLAB EDGE
GRANULAR FILL (REFER TO STRUCTURAL)
SLAB ON GRADE:
FLOOR TYPE F1:
92MM METAL STUD SPACED AT 600 O/C
22MM FURRING CHANNEL
16MM GYP. BD. TYPE X
16MM GYP. BD. TYPE X
INT. FIN PAINT COLOUR TO BE
SELECTED BY ARCHITECT
CEILING TYPE C2:FIRE RATED MEMBRANEC2
CEILING TYPE LEGEND
TYPE: DESIGN: CONSTRUCTION:
F13A1
140
3C
INT. FIN (COORDINATE W/ RM. FIN.
SCH.'S).
16MM GYP. BD.
89MM WOOD STUD, CAVITY FILLED WITH
SOUND ATTENUATION BATT INSULATION.
16MM GYP. BD.
INT. FIN. (COORDINATE W/ RM. FIN.
SCH.'S).
89MM WOOD STUD, CAVITY FILLED WITH
SOUND ATTENUATION BATT INSULATION.
16MM GYP. BD.
INT. FIN. (COORDINATE W/ RM. FIN.
SCH.'S).
R1A
R1B
C1
C2
F1EX METAL ROOF TO BE PAINTED
EX ICE AND WATER SHIELD MEMBRANE
EX OSB SHEATHING
EX WOOD TRUSS
(REFER TO STRUCTURAL)
NEW R60 BLOWN CELLULOSE INSULATION
NEW VAPOUR BARRIER MEMBRANE
NEW 13mm METAL FURRING CHANNEL
@400mm O/C
NEW 16mm GYPSUM BOARD
NEW PRIMER & PAINT
ROOF TYPE R1:
92
92
22
16
16
15
07
5
3A
WALL TYPE 3A1:ADD 16MM GYP BD ON FIRE RATED ROOM SIDE
3B
2D
EXISTING WOOD TRUSS
NEW MODIFIED BITUMEN ROOFING SYSTEM AS
SPEC'D
NEW 13MM PROTECTION BOARD
NEW TAPPERED RIGID INSULATION AS
REQUIRED TO SLOPE ROOF 2% TO DRAIN
NEW 152MM ROOFING INSULATION AS
SPEC'D. INSTALLED IN MULTIPLE LAYERS
WITH STAGGERED JOINTS
NEW VAPOUR RETARDER MEMBRANE
NEW 16MM PLYWOOD SHEATHING
(REFER TO STRUCTURE)
NEW ROOF FRAMING (REFER TO STRUCTURE)
NEW 13mm METAL FURRING CHANNEL
@400 O/C
NEW 16mm GYPSUM BOARD
NEW PRIMER & PAINT
ROOF TYPE R2:
R2R2
TYPE: DESIGN: CONSTRUCTION:
EX
EXISTING SLAB ON GRADE
(REFER TO STRUCTURE)
SLAB ON GRADE:
FLOOR TYPE EX:
F1
EX
EXTERIOR WALL:
WALL TYPE 2E:
2E
NEW PRE-FIN. WOOD SIDING.
NEW 25mm VERTICAL METAL FURRING @
600mm O.C..
NEW TYVEK MEMBRANE
NEW 51mm HOR. METAL Z-GIRTS @600mm O.C.
NEW 50mm SEMI RIGID MINERAL WOOL
CAVITY INSULATION. (R10)
NEW EXTERIOR SHEATHING
NEW WOOD STUD FRAMING (2x6)
NEW EXTERIOR SHEATHING
NEW 50mm SEMI RIGID MINERAL WOOL
CAVITY INSULATION. (R10)
NEW 51mm HOR. METAL Z-GIRTS @600mmO.C.
NEW TYVEK MEMBRANE
NEW 25mm VERTICAL METAL FURRING @
600mm O.C..
NEW ACM PANEL.
2D
EX
.
25MM SHEETROCK LINEAR PANELS
64MM C-H STUD @ 600 O/C
3-13MM FIRECODE C CORE GYP. BD.
INT. FIN PAINT COLOUR TO BE
SELECTED BY ARCHITECT
CEILING TYPE C3:HORIZONTAL FIRE RATED MEMBRANE OBMEC#89-1-118
C3 C3
393
8 25
EXISTING WOOD TRUSS
1319
215
19
152V
AR
IES
13
16 16
3A
140
3B
16
89
16
16
89
25 50
16
140 16
25
50
16 140 16
50
25
3A1
FOR FIRE RATED WALLS REFER TO : ULC W301 ( GA FILE No. WP3605) OR GA FILE No. WP3660
REFER TO DRAWINGS AO.2 FOR FIRE SEPARATION LOCATIONS
USE MOISTURE RESISTANT GYPSUM BOARD IN ALL "WET " AREAS
USE ABUSE RESISTANT GYPSUM BOARD IN CORRIDOR AND GENERAL USE.
USE TYPE X GYPSUM BOARD GOT ALL FIRE RATED WALLS AND CEILINGS
TYPICAL ALL PARTITIONS AND GYPSUM BOARD FINISH TO EXTEND TO U/S OF TRUSSES
TYPICAL STUD WALL SPACING TO BE 400 O/C UNLESS NOTED OTHERWISE. REFER TO STRUCTURAL
DRAWINGS FOR ADDITIONAL STUD SPACING REQUIREMENTS
GENERAL NOTES:
1
2
3
4
GENERAL NOTE 1
C4 92MM METAL STUD SPACED AT 600 O/C
22MM FURRING CHANNEL RUNNING
PERPENDICULAR TO STUDS @ 600 O/C
16MM WOOD V GROOVE SIDING
INT. FIN TO BE SLECTED BY ARCHITECT
CEILING TYPE C1:
C4
92
5
6
THE V
EN
TIN
GR
OU
P L
TD
AR
CH
ITEC
TSV
G
Client:
Scale :Drawn by : Checked by :
Revision Schedule
Project:
CN
Re
pro
du
ctio
n o
f d
raw
ing
s a
nd
re
late
d
do
cu
me
nts
in
wh
ole
or
in p
art
is
forb
idd
en
w
ith
ou
t w
ritt
en
pe
rmis
sio
n o
f Th
e V
en
tin
Gro
up
.
All
dim
en
sio
ns
an
d m
ea
sure
me
nts
mu
st b
e
ch
ec
ke
d a
nd
ve
rifie
d b
y t
he
Ge
ne
ral
Co
ntr
ac
tor
1 : 20
10
/26
/20
17 6
:51
:33
PM
V:\
+V
G O
tta
wa
Pro
jec
t Fi
les\
163
3 M
cN
ab
Bra
esi
de
\02
_W
ork
ing
Dra
win
gs\
07
Re
vit\
163
3 -
Mc
Na
b B
rae
sid
e -
Pe
rne
el B
uild
ing
09.2
6.r
vt
A0.2A
THE TOWNSHIP OF McNAB /
BRAESIDE
Author Checker
21688McNAB / BRAESIDE TOWN CENTRE
McNab / Braeside
ONTARIO
CO
NSTR
UC
TIO
N A
SSEM
BLI
ES /
NO
TES
No. Date Particular
Revision 1
Date 1 1
ISSUE FOR CLIENT REVIEW2017.08.222
ISSUE FOR CLIENT REVIEW2017.10.063
ISSUE FOR TENDER2017.10.124
ISSUE FOR BUILDING PERMIT &
TENDER
2017.10.111