  • Faculty of Information and Communication Technology

    ANALYSIS AND MODELING OF DATABASE STORAGE

    OPTIMIZATION POWER CONSUMPTION USAGE FOR GREEN

    DATA CENTERS

    Wan Noor Hamiza Binti Wan Ali

    Master of Computer Science in Database Technology

    2014

  • ANALYSIS AND MODELING OF DATABASE STORAGE

    OPTIMIZATION POWER CONSUMPTION USAGE FOR GREEN

    DATA CENTERS

    WAN NOOR HAMIZA BINTI WAN ALI

    A thesis submitted in fulfilment of the requirements for the degree of Master of

    Computer Science in Database Technology

    Faculty of Information and Communication Technology

    UNIVERSITI TEKNIKAL MALAYSIA MELAKA

    2014

  • ABSTRACT

    Data centers comprised of the building block of Internet Technology (IT) business

    organizations holding the capabilities of centralized repository for storage, management,

    networking and dissemination of data. The data centers consumed a lot of energy in order

    to ensure all the processes in data centers running completely every second which this

    situation can be lead to increase carbon footprint and give negative impact to the world

    (global warming). One way to reduce the energy consumption is by optimizing space

    storage in data centers. Thus, the proxy-based approach is used to optimize the space

    storage in CMR database in order to establish green data centers. This technique requires

    proxy candidate in order to drop some attribute for decrease the space storage. The proxies

    can be discovered by using a developed algorithm of functional dependencies (FDs) called

    as TANE algorithm. By using TANE algorithm, the proxy candidate and droppable

    attribute for table in CMR database can be discovered before the space saving can be

    calculate by given formula. The power saving can be calculated after the amount of space

    saving is known. The correlation between amount of space saving and amount of power

    saving was visualized in form of graph in the green data center correlation tool. The project

    concludes the result from the experiment achieved all the objectives and answered all the

    research questions.

    i

  • ABSTRAK

    Pusat data terdiri daripada organisasi perniagaan Teknologi Internet (IT) yang menjadi

    pusat repositori untuk penyimpanan, pengurusan, rangkaian dan penyebaran data. Pusat

    data memerlukan banyak tenaga elektrik untuk memastikan semua proses di pusat-pusat

    data berjalan dengan lancar setiap saat yang mana keadaan ini boleh membawa kepada

    peningkatan kesan karbon dan memberi kesan negatif kepada dunia (pemanasan global).

    Salah satu cara untuk mengurangkan penggunaan tenaga adalah dengan mengoptimumkan

    ruang penyimpanan data. Oleh itu, pendekatan berasaskan proksi digunakan untuk

    mengoptimumkan ruang penyimpanan dalam pangkalan data CMR disamping

    menubuhkan pusat data hijau. Teknik ini memerlukan calon proksi yang terdiri daripada

    atribut yang mempunyai kebergantungan berfungsi kepada atribut yang akan digugurkan

    sebagai cara untuk mengurangkan ruang dalam pangkalan data. Proksi boleh ditemui

    dengan menggunakan algoritma berdasarkan kerbergantungan berfungsi (FD) yang

    dikenali sebagai algoritma TANE. Dengan menggunakan algoritma TANE, calon proksi

    dan attribut yang akan digugurkan daripada jadual dalam pangkalan data CMR boleh

    ditemui sebelum pengiraan penjimatan ruang dibuat berdasarkan kepada formula yang

    diberi. Hubungan antara jumlah penjimatan ruang dan jumlah penjimatan kuasa

    ditunjukkan dalam bentuk graf di alat korelasi pusat data hijau. Kesimpulannya, projek ini

    mencapai semua objektif dan menjawab semua soalan penyelidikan

    ii

  • ACKNOWLEDGEMENT

    By the Name of Allah, the Most Gracious and the Most Merciful

    First, I would like to express my appreciation to Allah, the Most Merciful, and the Most

    Compassionate who has granted ne the ability and willing to start and complete my project.

    I do pray to His Greatness to inspire and enable me to continue the work.

    My most profound thankfulness goes to my supervisor DR. NURUL AKMAR BINTI

    EMRAN for her creativity encouraging guidance and directed me all the way through the

    process of developing the project. She is very helpful person and she is my inspiration to

    be more successful in the future.

    I would like to thank my beloved parents and family who have always been my biggest

    inspiration and always being supportive. Your advices are my greatest motivation to keep

    on achieving my dreams.

    Last but not least, I would like to thanks all my beloved friends and classmates whom

    supports me and also helps me in this project. Your co-operation, sacrifice, knowledge

    sharing and understanding is really appreciated.

    iii

  • DECLARATION

    I declare that this thesis entitle “Analysis and Modeling of Database Storage Optimization

    Power Consumption Usage for Green Data Centers” is the result of my own research

    except as cited in the references. The thesis has not been accepted for any degree and is not

    concurrently submitted in candidate of any other degree.

    Signature : ........................................................................

    Name : ........................................................................

    Date : ........................................................................

    iv

  • APPROVAL

    I hereby declare that I have read this dissertation/report and in my opinion this

    dissertation/report is sufficient in terms of scope and quality as a partial fulfillment of

    Master of Computer Science (Database Technology).

    Signature :……………. .....................................................

    Supervisor Name :……………………… ......................................

    Date :…………………….. ........................................

    v

  • LIST OF TABLES

    TABLE TITLE PAGE

    2.1 A Proxy Map in Pure Relational Table 21

    2.2 A Proxy Map in Multi-Valued Table 21

    2.3 Attribute and Schema of Microbial Data Sets 22

    2.4 Summary of Three Techniques 30

    3.1 Example of Amount Space Saving for each Proxy 45

    3.2 Values of PW Based on Amount of Space Saving 46

    4.1 Description of Bug Bug_Attribute, Taxon, Feat_Link and

    ORF_Attribute

    52

    4.2 Proxy Candidate and Droppable Attribute for Taxon Table 60

    4.3 Candidate and Droppable Attribute for Feat_Link Table 63

    4.4 Proxy Candidate and Droppable Attribute for ORF_Attribute Table 66

    4.5 Proxy 1 from CMR Taxon Table 70

    4.6 Proxy 2 from CMR ORF_Attribute Table 70

    4.7 Proxy3 from CMR ORF_Atrribute Table 71

    4.8 Proxy 4 from CMR Taxon Table 72

    4.9 Proxy 5 from CMR Taxon Table 73

    4.10 Proxy 6 from CMR Bug_Attribute Table 74

    4.11 Proxy 7 from CMR Taxon Table 75

    4.12 Proxy 8 from CMR ORF_Attribute Table 76

    4.13 Proxy 9 from CMR Feat_Link Table 76

    4.14 Proxy 10 from CMR Feat_Link Table 77

    4.15 Power Saving on Proxy 1 78

    4.16 Power Consumption on Proxy 2 70

    4.17 Power Consumption on Proxy 3 80

    4.18 Power Consumption on Proxy 4 81

    vi

  • 4.19 Power Consumption on Proxy 5 82

    4.20 Power Consumption on Proxy 6 82

    4.21 Power Consumption on Proxy 7 83

    4.22 Power Consumption on Proxy 8 83

    4.23 Power Consumption on Proxy 9 85

    4.24 Power Consumption on Proxy 10 86

    4.25 A Set of Proxy with Details of Droppable Attribute, Proxy Candidate,

    Space Saving and Power Saving

    87

    5.1 Details for G3 Error, Droppable Attribute and Proxy Candidate each

    Table in CMR Database

    96

    5.2 Size of Table Involves in Space Saving Calculation 98

    5.3 Relationship Percentage Amount of Space Saving and Percentage

    Amount of Power Saving

    99

    vii

  • LIST OF FIGURES

    FIGURE TITLE PAGE

    2.1 Comparison of Data Center Power Consumption between Intel Xeon

    Processor and Older Single-Core Processor

    9

    2.2 Comparison of Monthly Average PUE 11

    2.3 A Conceptual Diagram Illustrating on How the Use of Power in Data

    Centers Impact an Environment

    17

    2.4 Proxy Map Size of attribute for Evidence Table 23

    2.5 Proxy Map Size of attribute for Taxon Table 23

    2.6 Proxy Map Size of attribute for Bug_attribute Table 24

    2.7 Energy Calculating Algorithm 26

    2.8 Compression Graph 29

    2.9 TANE Main Algorithm 33

    2.10 Generating Level Algorithm 33

    2.11 Computing Dependencies Algorithm 34

    2.12 Pruning the Lattice 35

    2.13 Computing Partitions Algorithm 36

    2.14 Approximate Dependencies Algorithm 36

    3.1 Flowchart of Project Implementation 39

    3.2 Flowchart of Experimental Based Research Methodology 42

    3.3 Command to Analyze Table 44

    3.4 Command to Get Size of Table in Bytes 44

    3.5 RAD Model 47

    3.6 An Expected Graph of Correlation between

    Space Saving and Power Saving

    48

    3.7 Quadrants of Plot Graph 49

    4.1 Home Screenshot of Cygwin64 Terminal 54

    4.2 Screenshot of Cygwin64 Terminal for command cd d:\TANE 54

    viii

  • 4.3 Screenshot of Cygwin64 Terminal for command ls 55

    4.4 Screenshot of Cygwin64 Terminal for command cd descriptions 55

    4.5 Screenshot of Cygwin64 Terminal for command cd src 55

    4.6 Range 0.00 G3 Error for Bug_Attribute Table 57

    4.7 Range 0.10 G3 Error for Taxon Table 60

    4.8 Range 0.20Figure 4.15: Range 0.20 G3 Error for Feat_Link Table 64

    4.9 Range 0.20 G3 Error for ORF_Attribute Table 67

    4.10 Screenshot of selectpage.php 88

    4.11 Screenshot of a Proxyset Table in phpMyAdmin Database 89

    4.12 Screenshot of correlationtool2.php 90

    4.13 Screenshot of graph.php 91

    4.14 Screenshot of FusionCharts for Dreamweaver (DataGrid) 91

    4.15 Screenshot of FusionCharts for Dreamweaver (Chart Selection) 92

    4.16 Screenshot of FusionCharts for Dreamweaver (General Option) 93

    5.1 Correlation between Power Saving with Space Saving Scattered

    Graph

    102

    5.2 Quadrants of Plot Graph 103

    ix

  • LIST OF ABBREVIATIONS

    AHU - Air Handling Unit

    CMR - Comprehensive Microbial Resources

    CO2 - Carbon Dioxide

    CRAC - Computer Room Air Conditioning

    CPU - Central Processing Unit

    CSV - Comma Separated Values

    DBA - Database Administrator

    DX - Direct Expansion

    FDs - Functional Dependency

    GDCE - Green Data Center Effectiveness

    GUI - Graphical User Interface

    kW - Kilowatts

    IT - Internet Technology

    PHP - Hypertext Preprocessor

    PUE - Power Utilization Effectiveness

    RAD - Rapid Application Development

    UPS - Uninterruptible Power Supply

    XML - Extensible Markup Language

    x

  • TABLE OF CONTENT

    PAGE

    ABSTRACT i

    ABSTRAK ii

    ACKNOWLEDGEMENT iii

    DECLARATION iv

    APPROVAL v

    LIST OF TABLES vi

    LIST OF FIGURES viii

    LIST OF ABBREVIATIONS x

    1. INTRODUCTION

    1.1 Introduction 1

    1.2 Background 1

    1.3 Problem Statement 4

    1.4 Research Question 4

    1.5 Objective 5

    1.6 Scope 6

    1.7 Significance of Study 6

    1.8 Expected Output 6

    2. LITERATURE REVIEW

    2.1 Introduction 7

    2.2 Power Consumption in Green Data Center 7

    2.2.1 New Technology of Processor 8

    2.2.2 New Cooling System 9

    2.2.3 Server Consolidation Technique 12

    2.2.4 Calculation of Power Consumption Used by One Server 15

    2.2.5 The Impact of Power Consumption in Data Centers on

    the Environment

    16

    2.3 Methods of Space Saving Optimization 18

    2.3.1 Proxy-Based Approach 18

    xi

  • 2.3.2 Deduplication Technique 24

    2.3.3 Data Compression Method 27

    2.4 Comparison of Method 30

    2.5 TANE Algorithm 32

    2.5 Conclusion 37

    3. METHODOLOGY

    3.1 Introduction 38

    3.2 Project Implementation Methodology 38

    3.2.1 Experimental Based Research Methodology 41

    3.2.2 Development Methodology 46

    3.3 Conclusion 49

    4. RESULT

    4.1 Introduction 51

    4.2 Pre-Processing Analysis 51

    4.2.1 Installation of TANE Algorithm 53

    4.2.2 Proxy Discovery 53

    4.3 Space Saving Calculation 69

    4.4 Power Consumption Estimation 78

    4.5 Correlation Tool 88

    4.6 Conclusion 93

    5. RESULT ANALYSIS AND DISCUSSIONS

    5.1 Introduction 95

    5.2 Proxy Candidate Discovery 95

    5.3 Space Saving Analysis 98

    5.4 Power Consumption Analysis 99

    5.5 Graph Analysis 101

    5.6 Conclusion 103

    6. CONCLUSION 104

    REFERENCES 108

    APPENDINCES 111

    xii

  • 1

    CHAPTER 1

    INTRODUCTION

    1.1 Introduction

    In this chapter, the background of green data centers will be presented. Data center

    is one of the crucial parts for physical data storage which required efficiency in handling it

    in order to avoid high power consumption. We motivate the need for green data centers

    based on the problems identified on the traditional data centers before formulating the

    objectives of the research.

    1.2 Background

    Data centers comprised of the building blocks of Internet Technology (IT) business

    organizations holding the capabilities of centralized repository for storage, management,

    networking and dissemination of data. Major part of a data center is data server where all

    data centers plagued with a thousand servers (Uddin and Rahman 2010). These servers

    consumed a lot of energy without performing useful work. The operators of data center

    must fight to reduce utility cost as expensing of operating component to remain

    competitive (Intel, 2011). Based on the finding of the EPA’s report on server and data

    centers power consumption, one of the conclusion from this report is the server and data

    centers consume about 2.5 percent of all purchased electricity (John, 2013). Thus, green

    data centers needed to avoid wasteful power consumption and space storage. Green data

    centers are managed and are operated on green computing principles which provide the

  • 2

    similar capabilities and characteristics of a typical data centers. However, they are four

    distinctive characteristics such as reduce carbon footprint, optimization of space, cost

    saving, and more efficiency as compared to a traditional data centers. Efficiency in data

    centers can be measured by hardware assets, power, cooling, space and human resources.

    First characteristic of green data centers as just mentioned earlier is reducing

    carbon footprint. According to Pallamentary Office of Science and Technology (POST

    2006), a carbon footprint can be defined as the total amount of Carbon Dioxide (CO2) and

    other greenhouse gases which released over the full life cycle of a process that populate a

    data center such as servers, UPS, building shell, cooling, etc (Bouley, 2012). The carbon

    footprint is not expected to be 100 percent accurate because it is depended on financial and

    environment terms. Thus, by establishing green data centers, we can reduce the carbon

    footprint. Second characteristic is optimization of space which means the large amount of

    data storage not only leads to inconsistent and impractically to maintain the data centers,

    however also render to inefficient power usage. By optimizing the required storage to store

    large data volumes, the physical data storage may be reduced ( Emran, Abdullah and Isa

    2012). Space saving also gives benefits not only when space is highly constrained, but also

    when concern is to reduce query response time. By reducing the space to store the data, the

    time taken for input/output operation query also can be reduced.

    Furthermore, third characteristic of green data centers is cost saving. Even though

    an establishment a green data center can be expensive up front, but long-term cost saving

    can be realized on operation and maintenance. When fewer data servers will be used, it is

    means that fewer data centers space, lower power and cooling cost required. We also can

    reduce cost with downsized, generator and battery backup infrastructure proportional to

    reduction in peak power requirements. In addition, the fourth characteristic is gain more

    efficiency. Efficiency of the data centers can be shown because providers can avoid

  • 3

    performing the task of: adding new staff, improving the server, adding new equipment of

    data center and so on. Some of specific actions which the providers or industries can take

    to support by increasing data center efficiency such as run more sophisticated power

    management and define certain points for processor, server and data centers efficiency

    based on the current technologies (Emerson, 2009). Efficiency of green data center will be

    increase when limits the units of server by doing the optimization of space storage and

    power consumption.

    Based on four characteristics of green data centers as described earlier, all of them

    are related to each other. When space is optimized, automatically cost of maintenance and

    operation can be reduced. Then the efficiency of data centers will be increase where leads

    to reduce carbon footprint. Consequently, this project proposed modelling of database

    storage optimization power consumption usage for green data centers. Our main focus is to

    study correlation between space saving and power consumption based on the selected

    technique. The selected technique is proxy based approach because this technique requires

    reduce physical storage space at schema level compared to dedulication technique and data

    compression method that describes in the next chapter.

    Comprehensive Microbial Resource (CMR) database has been chosen in order to

    use the data sets. The data sets that have been used from four tables in CMR database

    which are Bug_Attribute, Feat_Link, ORF_Attribute and Taxon. The data sets from these

    four tables undergo the pre-processing steps for discovered a set of proxy by using TANE.

    TANE is an algorithm to find out the functional dependency (FDs) which presented by

    Huhtala et al (Huhtala et al., 1999). After a set of proxy already discovered, we can

    calculate the space saving and power saving before presented the correlation between

    power consumption and space saving in form of scattered graph in the green data center

    correlation tool.

  • 4

    1.3 Problem Statement

    The major problem of this project is on identifying the correlation between space

    saving and power consumption. It is crucial for data centers administrator to plan or decide

    on the amount of space to be saving based on the amount of targeted power saving. In

    addition, sensitivity amount of power consumed to the increasing volume of space storage

    also one of the problem where when the lower power is consumed, it will give benefits in

    terms of cost saving and efficiency of data centers. Another problem is tool that use in

    order to determine power consumption which related to amount of space saving. It is

    because once the correlation of space saving and power consumption is identified, we

    needs tool to see distribution of plotted points on scattered graph which is the graph will be

    divide into four quadrants and analyze the best case scenario based on the plotted points.

    1.4 Research Question

    The following are the research questions that arise from the problem stated in the

    problem statement section:

    i. How space saving correlates to power consumption?

    ii. How sensitive is the amount of power consumed to the amount of increase

    in storage space?

    iii. Is there a case for a selected storage space optimization method (proxy-

    based approach) that contributes to lower power consumption?

  • 5

    1.5 Objective

    The following are the objectives of this project:

    i. To investigate the standard amount of power consumption in data

    centers.

    In order to understand the power consumption rate in data centers, we need

    to explore the standard amount of power consumption rate based on read

    scenarios. The result of this step will be used as the based-line for our

    correlation process.

    ii. To design the model of power consumption for green data centers using

    space saving parameter.

    The correlation tool will be design and develop based on the standard

    amount of power consumption and space saving which has been identified

    in order to do correlation.

    iii. To simulate the correlation between data center’s power consumption

    and space saving.

    By using storage space saving rate and power consumption variables,

    correlation between these two variables will be graphically presented in

    form of a data center correlation tool.

  • 6

    1.6 Scope

    This project covers the study of database storage optimization’s efficiency in

    relation to the power consumption variable in order to establish a green data center for

    microbial domain from the J. Craig Venter Institute. We use the data sets from CMR which

    includes four tables in order to find out a set of proxy. The tables that will be used are

    Bug_Attribute, Feat_Link, ORF_Attribute and Taxon. Even though there are 25 tables in

    the CMR database, but not all tables can be used because some of the data sets cannot be

    download from the internet due to the corrupted data sets. Space storage and power

    consumption can be correlates after the space saving and power saving are calculated.

    1.7 Significance of Study

    The investigation on the correlation of power consumption and space storage

    contributes to better understanding on the behaviour of proxy-based approach. The result

    from this project can be applied by database administrators (DBAs) from J. Craig Venter

    Institute in order to minimize the space storage and power consumption in the data center.

    Technical issues during the development and implementation of the correlation tool

    provide guidance for future improvement.

    1.8 Expected Output

    Expected output from this project is a software green data center correlation tool

    that can be used to correlate the amount of power saving for a given space saving target for

    DBAs.

  • 7

    CHAPTER 2

    LITERATURE REVIEW

    2.1 Introduction

    This chapter over review of literature on power consumption and techniques of

    space saving for green data centers. By understanding the requirements of green data

    centers from power consumption and space saving point of view, the model of correlation

    between spaces saving and power consumption can be built.

    2.2 Power Consumption in Green Data Center

    A data center is a facility that comprised of the building blocks of IT business

    organizations holding the capabilities to supply source energy for IT equipments used. The

    outlines of common data center energy consumption can be divided into three areas such as

    server load and computing operation, cooling equipment and power conversion and

    distributions (Energy, 2012). There is an increasing concern about the cost and availability

    of energy (John, 2013) due to many researchers study how to optimize power consumption

    in many domains such as IT (eg., data center), engineering (e.g., digital signal processor)

    and so on because by reducing the power consumption in data center, the emission of CO2

    can be reduce and operating cost can be saved (eg., cooling system for data centers).

    Power consumption in green a data center can be defined as amount of energy

    consumed by running the data centers in order to support process or system (e.g., cooling

  • 8

    system). Power consumption used for data centers is about half from the electricity for an

    organization and percentages of power consumption usage is increase year by year as

    mentioned by DataCenterDynamic (DCD Intelligence, 2014). The increasing of usage is

    about 6.8% from 2012 to 2013. Hence, we need to overcome this problem before its

    getting worst because rising of power consumption will let to high carbon footprint.

    Consequently, there are a few approaches on how to optimize power consumption in data

    centers. In this report, we will elaborate about three approaches for optimizing power

    consumption which is by used the latest technology of processor, develop new cooling

    system and by applying server consolidation technique. Later on, we also will be

    explaining regarding to energy consumes by one server and the impact of power

    consumption in data centers on the environment.

    2.2.1 New Technology of Processor

    Based on white paper from Intel (Intel, 2013), they have explained the

    strategies developed and used by CERNopenlab. CERN is the largest physical

    laboratory in worlds which function to provide the accelerators and infrastructure

    for high-energy physic research. Comparison between power consumption of Intel

    Xeon processors and older single-core processor has been made by CERN. The

    latest Intel Xeon processor is based on the Intel Core micro architecture which can

    support about five times more compute power per Watt than older single-core

    processor which based on the earlier Intel NetBurst micro architecture. It is because

    the latest Intel Xeon processor has four cores per processors compared to older

    single-core processor that have only single core per processors.

  • 9

    Figure 2.1 Comparison of Data Center Power Consumption between Intel Xeon Processor

    and Older Single-Core Processor (Intel, 2013)

    A shown in Figure 2.1 is a graph of comparison of power consumption

    between Intel Xeon processors and older single-core processor has been produced

    by CERN. CERN was analyzing the data centers usage in MegaWatts power

    consumption from 2008 until 2012 to see the power usage differences between

    these years. CERN concluded that moving to the latest Intel Xeon processors is the

    best solution because total power consumption can be reduced about five times

    rather than the older single-core processors.

    2.2.2 New Cooling System

    By analyzing another research that was conducted by Green Data Center

    Project from National Snow and Ice Data Center (NSIDC), power consumption can

    be reduced by optimizing the cooling data center functions. The traditional data

    center cooling infrastructure used standard air conditioning system that used direct

    expansion (DX). DX system also can be referred as computer room air conditioner

  • 10

    (CRAC). DX is function to remove heat via a liquid refrigerant as running in a car

    or refrigerator. Since DX used synthetic refrigerant which harmful the environment

    and compressor in DX requires lot of energy. Even though this system is quite

    economical but it was become antiquated. Thus, Green Data Center Project was

    finding another solution to overcome this problem.

    According to Weerts et al (Weerts et al., 2012), an approach that has been

    implemented is by applying new cooling system design that consists of a unique

    cooling system that uses both airside economization and a new air conditioner

    (indirect evaporative cooling). Airside economizer control mode lets the air

    handling unit (AHU) to cool the space with outdoor air when the outdoor air is

    cooler than the air space. However, in several locations especially the Midwest and

    East Coast of the United State, the airside economization may not work well cause

    by hot and humid environment. On the other hand, indirect evaporative cooling

    used the Maisotsenko Cycle which operates direct and indirect evaporative cooling

    in order to produce a supply air state (16.7 °C to 22.2 °C).

    In order to compare the differences between CRAC system and new cooling

    system, the data center efficiency should be calculated. The Power Utilization

    Effectiveness (PUE) for any data center can be calculated by using (1).

    Power) Power)/(IT (Total =PUE (1)