faira transparency reports 9927 171st ave se ......608 state st. south kirkland, wa 98033...

125
608 State St. South Kirkland, WA 98033 www.faira.com [email protected] +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at http://www.faira.com/listings/11616 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Upload: others

Post on 14-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

608 State St. South Kirkland, WA 98033

www.faira.com

[email protected] +1.800.571.FAIR

FAIRA TRANSPARENCY REPORTS

9927 171st Ave SE, Renton, WA 98059

Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.

You may view more detailed information for this home and can make an offer at

http://www.faira.com/listings/11616 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Page 2: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Confidential Inspection Report

LOCATED AT:9927 171st Ave SE

Renton, Washington 98059

PREPARED EXCLUSIVELY FOR:Faira.com

INSPECTED ON:Friday, March 30, 2018

Inspector, Isaac McPheeStrong Foundations Home Inspection

Page 3: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 2 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Executive Summary

This is a summary review of the inspectors' findings during this inspection. However, it does not contain every detailed observation. This is provided as an additional service to our client, and is presented in the form of a listing of the items which, in the opinion of your inspector, merit further attention, investigation, or improvement. Some of these conditions are of such a nature as to require repair or modification by a skilled craftsman, technician, or specialist. Others can be easily handled by a homeowner such as yourself.

Often, following the inspector's advice will result in improved performance and/or extended life of the component(s) in question. In listing these items, your inspector is not offering any opinion as to who, among the parties to this transaction, should take responsibility for addressing any of these concerns. As with most of the facets of your transaction, we recommend consultation with your Real Estate Professional for further advice with regards to the following items:

= Item in poor condition, warranting immediate repair or replacement

= Item that warrants repair or replacement now or in the near term, but does not pose an immediate risk or threat

= Upgrade recommended, but not required

= Potentially dangerous or hazardous condition that should be corrected as soon as possible (safety concern)

= Item not operating at the time of the inspection, or unable to be inspected for another reason

= Item that warrants continued monitoring or further evaluation by licensed professional. Though issues may not necessarily exist in the present or are not readily visible, monitoring or further evaluation is recommended.

Introductory Notes

NOTES

1: - The home was occupied at the time of the inspection, with personal possessions and furniture in every room of the home that prohibited the inspection of some surfaces or systems. This includes numerous electrical outlets, lights, walls, floors, etc. We recommend further evaluation of the home if it becomes vacant, in order to more thoroughly evaluate the condition.

Exterior/Site/Ground

FOUNDATION

2: - Hairline and/or small cracks, within normal tolerances, are visible. This type of cracking is often a result of shrinkage of materials and/or minor settlement and usually does not affect the strength of the foundation. No action is indicated.

EXTERIOR PLUMBING

3: - One or more exterior hose bibs in the landscaping were not operating. This may be due to a valve shut off or other reason. Recommend inquiring of homeowner as to the cause and repair as necessary.

Page 4: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 3 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

4: - One or more hose bib(s) is/are dripping/leaking from the handle when operated. We recommend the washer be replaced and/or the packing nut be tightened.

OUTDOOR RECEPTACLES

5: - A receptacle cover plate at the front of the home is damaged. We recommend it be replaced during the course of normal maintenance.

HARDBOARD SIDING

6: - The masonry board siding shows routine wear but is generally in serviceable condition. We recommend minor maintenance to ensure maximum service life.

DOORS

7: - Several exterior doors or door frames had some damage, primarily superficial. We recommend they be repaired or replaced.

GRADING

8: - Grading is sloped toward the structure in some areas. Low spots and negative grading promote water accumulation near the building, leading to foundation problems. It is important that drains at the side of the home be monitored to ensure that proper draining is taking place during and after periods of heavy rain.

DRAINAGE

9: - The drainage system appears to be in serviceable condition, but one or more of the grates is clogged and would be ineffective in a heavy rain. We recommend that debris be cleaned from the grates and pipes be cleaned to ensure proper operation during heavy weather.

DRIVEWAY

10: - The minor cracks in the driveway are of a cosmetic nature. However, they do indicate movement in the soil and, over time, may develop into an aesthetic issue and/or a safety concern because of tripping hazards.

DECK

11: - There are deteriorated deck boards at the surface of the rear deck, as well as on railings and other wood components, which may present a safety hazard if left unrepaired. We recommend replacement of all damaged material.

RAILINGS

12: - The railings at the rear deck may not be sturdy enough to resist a person's weight. We recommend that the railings be reinforced or replaced in accordance with present standards.

FENCING

13: - The fencing is generally serviceable but shows signs of routine wear and is in need of minor maintenance. Typically, fencing around the perimeter of the home is considered a shared responsibility between owners of adjacent properties. Recommend inquiring of neighbors prior to making repairs.

GATES

14: - The gates show signs of wear/deterioration and the need for maintenance in order for proper and continued operation.

Page 5: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 4 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

VEGETATION

15: - Some trees or shrubberies were observed to be in contact with or near the siding or foundation. Recommend trimming back all trees and shrubberies at least 6 inches from the home in order to protect the home's surface from moisture or pest intrusion.

TRIM

16: - The trim at the several locations around the home is worn and in need of painting/caulking maintenance, or damaged/deteriorated. We recommend that trim be repaired and painted, and deteriorated wood trim be repaired or replaced. Note: Damaged siding or trim may act to hide further deterioration or defects within the wall. Only removing portions of the siding/trim and further evaluating the interior of the wall will fully reveal the extent of any hidden damage.

FASCIA

17: - Portions of the fascia are weathered, with blistered and/or peeling paint. This will require surface preparation and refinishing in the course of routine property maintenance to restore surface appearance.

EAVES/SOFFITS

18: - At one or more locations we observed sagging sheathing at the eaves, indicating improper support or installation. We recommend repair to prevent damage to the roof surface or sheathing.

PAINT/STAIN

19: - The exterior paint is in fair to good condition but appears a bit 'tired'. Except where noted otherwise, the need for painting is primarily cosmetic.

20: - In several locations around the home the caulking is in need of repair. Ensure that all gaps, particularly around penetrations including doors and windows, are properly caulked to prevent moisture intrusion or damage.

Roofing

Composition Shingle

SURFACE

21: - Some moss was growing on the roof surface. As a result, shingles can lift or be damaged. Leaks can result and/or the roof surface can fail prematurely if the moss is left to grow unabated. Efforts should be made to kill the moss during its growing season (wet months). Typically, zinc or phosphate based chemicals are used for this and must be applied periodically.

22: - The roof surface is in generally functional condition, and no evidence of leaks were noted at present, across the surface we observed numerous indications of granulation loss, cracking or broken shingles (especially at the ridges where shingles are bent), and exposed nails or staples, puncturing the roof surface. These items indicate that the roof is older and in need of repairs in the near term. Recommend further evaluation by a licensed roofing professional to determine a course of action, as well as repairs of roof as needed to prolong the life of the roof surface and protect the home and continuing to monitor as the surface ages.

Page 6: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 5 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

FLASHINGS: OVERALL

23: - In one or more locations the metal roof flashing is lifting up from the roof surface, leaving exposed nail holes. Recommend reattaching the flashing to the roof surface and patching any nail holes as needed.

CHIMNEY AT ROOF

24: - Wood-framed chimneys are an often-neglected portion of the home's siding and trim. The siding and trim at the chimney at the roof is in marginal condition, with some maintenance needed. This maintenance includes painting and caulking, and may require the replacement of some siding or trim pieces as needed.

OTHER VENTS

25: - One of the vent caps or pipes is corroded. We recommend it be prepped and painted to restore its cosmetic appearance and prevent damage.

GUTTERS

26: - Debris and standing water was present in portions of the gutters, which limited our visual inspection. We recommend all debris be removed to ensure proper drainage. The condition of the gutters can be better assessed at that time.

GENERAL COMMENT

27: - This roof is older and near the end of its expected service life. Although it is presently watertight, repairs are needed at present and the need for replacement should be expected within the next few years.

Garage

FLOOR

28: - There are cracks in the floor slab with minor vertical displacement of the slab toward the middle of the garage. This is not a reflection on the condition of the rest of the building. No action is indicated.

GENERAL COMMENT

29: - Due to the presence of personal belongings, access to portions of the area were effectively blocked at the time of our inspection. A 'walk-through' is recommended when the area is cleared and accessible.

Kitchen

CABINETS

30: - The cabinets are in serviceable condition. Several of the doors need adjustment of hinges and latches for smoother operation.

COUNTERTOPS

31: - The caulk/grout at the joint between the countertop and the wall is cracking and discolored. Recommend replacing caulk/grout to prevent moisture intrusion behind the countertop and cabinet.

DISHWASHER

32: - The dishwasher is not properly attached to the cabinets. We recommend it be attached according to the manufacturer's installation instructions.

Page 7: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 6 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

33: - The dishwasher door and control panel had minor damage/cracking. Recommend repair as needed.

MICROWAVE

34: - The built-in microwave was not operating using normal controls. Recommend further evaluation and repair.

Bathroom

Second Floor Hallway

WATER BASIN

35: - The drain stop is defective. We recommend it be repaired or replaced.

SHOWER WALLS

36: - Recommend sealing the grout in the bathroom shower. This is an item of regular maintenance that will help prolong the life of the shower wall and floor materials.

BATHROOM FLOOR

37: - Particle board trim pieces at the bathroom floor showed signs of swelling. This is typical when this type of trim is used in bathrooms, as it is highly susceptible to moisture. Recommend replacing trim as warranted.

CABINETS

38: - The cabinets are in serviceable condition. Several of the doors need adjustment of hinges and latches for smoother operation.

COUNTERTOPS

39: - Caulking at the countertop/backsplash joint is cracking. Recommend recaulking to prevent moisture damage.

Second Floor Master

BATHTUB

40: - Caulking or grout around the perimeter of the bathtub or surround is cracked or missing in several areas. Ensure all joints and gaps are fully sealed to prevent moisture damage.

SHOWER

41: - The showerhead was not installed correctly and leaked from the fitting when operated. Recommend reinstalling.

SHOWER WALLS

42: - Recommend sealing the grout in the bathroom shower. This is an item of regular maintenance that will help prolong the life of the shower wall and floor materials.

GLASS ENCLOSURE

43: - The sliding glass shower door was difficult to operate and is in need of maintenance/adjustment for full operation.

Page 8: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 7 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

VENTILATION

44: - The exhaust fan is very noisy and is not likely to be used in its present condition. We recommend that it be serviced or replaced to restore quite operation.

Bedroom

Second Floor Master

CEILING

45: - There are ceiling and wall cracks that appear outside of the range of normal. These can be patched, prepared and finished in the course of routine maintenance. It should be understood that this type of cosmetic cracking may recur due to minor movement in the structure. Continue to monitor and if cracks appear to grow, recommend further evaluation.

DOORS

46: - The door is missing its door stop. We recommend a stop or bumper be installed to prevent damage to the surfaces behind the door.

Second Floor Southeast

WALLS

47: - The wall and window frame area on the south side of the home shows signs of warping and unusual settlement. Though the cause of this condition was not determined, we recommend repairs to restore cosmetic appearance, and continuing to monitor this area for any signs of unusual movement. Further evaluation would be recommended if the condition worsens.

CLOSET DOORS

48: - The door does not slide properly, indicating portions of the hardware are not properly installed. We recommend repair or replacement.

Living Room

WALLS

49: - There are minor wall and ceiling cracks. These can be patched, prepared and finished in the course of routine maintenance. It should be understood that this type of cosmetic cracking may recur due to minor movement in the structure.

DOORS

50: - The exterior living room door hardware is damaged or not operating properly. The deadbolt is not operating and the hardware to open half of the door is missing. We recommend repair or replacement of the door and/or hardware.

FIREPLACE

51: - Home inspectors are not certified the chimney professionals. Only a level 2 inspection performed by a CSIA (Chimney Safety Institute of America) certified chimney sweep can determine the condition of the flue and whether the fireplace is safe to use. Recommend a Level 2 inspection and cleaning/servicing of the fireplace and chimney flues by a qualified professional. Clean chimneys don't catch on fire.

Page 9: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 8 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

52: - Some erosion of the firebricks is normal over time. In this case, the back of the firebox is deeply eroded and past its useful service life. We recommend the firebricks be replaced.

Family/Dining Room

WALLS

53: - The wall and window frame area on the south side of the home shows signs of warping and unusual settlement. In the family room this has led to the window being difficult to operate. Though the cause of this condition was not determined, we recommend repairs to restore cosmetic appearance, and continuing to monitor this area for any signs of unusual movement. Further evaluation would be recommended if the condition worsens.

Library/Office

DOORS

54: - The door is not properly aligned in the frame and doesn't latch. We recommend adjustments to the hardware or frame to restore proper function.

Interior

SURFACES: OVERALL

55: - There is wear and tear throughout the house, of the type generally resulting from age and heavy use. We make no attempt to list all cosmetic flaws and suggest that most of these deficiencies will be addressed by routine maintenance and upgrading.

WALLS & CEILINGS

56: - There are minor cracks in the walls and/or ceilings. This is a common condition with this type of construction and does not indicate a structural deficiency. The cracks can be repaired or painted over during routine maintenance.

DETECTORS: OVERALL

57: - Carbon monoxide detectors were not found in the home. Typical building practice calls for at least one CO detector per floor of living space. Recommend installing CO detectors due to safety concerns.

58: - We note that the detectors present were visibly older - it is recommended that smoke detectors be replaced every 10 years in order to ensure proper operation, in addition to batteries being replaced every 6 months. Recommend replacing all detectors in this home with newer models.

Crawl Space

ACCESS

59: - There is a very large drop from the basement door into the crawlspace. We recommend the installation of a permanent stairs or ladder for easier access.

Page 10: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 9 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

WALL FRAMING

60: - Portions of the exterior wall sheathing and/or framing was showing signs of moisture-related damage below the dryer vent. We recommend further evaluation to determine the cause of this damage, and replacement of any damaged materials.

PEST CONTROL

61: - Containers of bait and/or traps have been placed in the crawl space, indicating past problems with rodents. No obvious recent activity was evident and it might be assumed that this problem has been solved.

FLOOR INSULATION

62: - There are fiberglass batts that have fallen out of place. We recommend this material be secured back in place.

Heat

Forced Hot Air

AIR FILTERS

63: - The filter has accumulated significant debris which decreases its effectiveness and blocks air flow. This can dramatically decrease the efficiency of the heating system. We recommend the filter be removed, cleaned and replaced if necessary.

GENERAL COMMENT

64: - The last service date of the gas forced air furnace appeared to be more than 1 year ago, or the inspector was unable to determine the last service date. Ask the property owner when it was last serviced. If unable to determine the last service date, or if last service date was more than one year ago, recommend that a qualified HVAC technician inspect, clean, and service the system, and make repairs if necessary. For safety reasons, and because the system is fueled by gas, this servicing should be performed annually in the future. Any needed repairs noted in this report should be brought to the attention of the HVAC technician when it is serviced.

Electrical System

CB MAIN PANEL

65: - Some of the panel cover screws are missing. We recommend proper, blunt-end screws be installed.

Insulation/Energy

FLOOR INSULATION

66: - There are fiberglass batts that have fallen out of place. We recommend this material be secured back in place.

Page 11: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 10 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Friday, March 30, 2018Faira.com

9927 171st Ave SERenton, Washington 98059

Dear Faira.com,

We have enclosed the report for the property inspection we conducted for you on Friday, March 30, 2018 at:

9927 171st Ave SERenton, Washington 98059

Our report is designed to be clear, easy to understand, and helpful. Please take the time to review it carefully. If there is anything you would like us to explain, or if there is other information you would like, please feel free to call us. We would be happy to answer any questions you may have.

Throughout the report, you'll find special symbols at the front of certain comments. Below are the symbols and their meanings:

= Item in poor condition, warranting immediate repair or replacement

= Item that warrants repair or replacement now or in the near term, but does not pose an immediate risk or threat

= Upgrade recommended, but not required

= Potentially dangerous or hazardous condition that should be corrected as soon as possible (safety concern)

= Item not operating at the time of the inspection, or unable to be inspected for another reason

= Item that warrants continued monitoring or further evaluation by licensed professional. Though issues may not necessarily exist in the present or are not readily visible, monitoring or further evaluation is recommended.

We thank you for the opportunity to be of service to you.

Sincerely,

Inspector, Isaac McPheeStrong Foundations Home Inspection

Page 12: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 11 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Page 13: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Table of Contents

Executive Summary.......................................................................................................................................2

Introduction..................................................................................................................................................13

Introductory Notes.......................................................................................................................................14

Exterior/Site/Ground....................................................................................................................................14

Roofing........................................................................................................................................................27

Garage.........................................................................................................................................................34

Kitchen.........................................................................................................................................................37

Laundry Area...............................................................................................................................................43

Mud Room...................................................................................................................................................46

Bathroom.....................................................................................................................................................47

Bedroom......................................................................................................................................................61

Living Room.................................................................................................................................................68

Family/Dining Room....................................................................................................................................72

Library/Office...............................................................................................................................................75

Interior.........................................................................................................................................................76

Attic..............................................................................................................................................................78

Crawl Space................................................................................................................................................81

Plumbing......................................................................................................................................................86

Water Heater...............................................................................................................................................89

Heat.............................................................................................................................................................93

Electrical System.........................................................................................................................................97

Insulation/Energy.......................................................................................................................................100

Locations of Emergency Controls..............................................................................................................101

Environmental Concerns...........................................................................................................................103

Conclusion.................................................................................................................................................103

tmp6DF0....................................................................................................................................................104

Page 14: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 13 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Introduction

We have inspected the major structural components and mechanical systems for signs of significant non- performance, excessive or unusual wear and general state of repair. The following report is an overview of the conditions observed.

In the report, there may be specific references to areas and items that were inaccessible. We can make no representations regarding conditions that may be present but were concealed or inaccessible for review. With access and an opportunity for inspection, reportable conditions may be discovered. Inspection of the inaccessible areas will be performed upon arrangement and at additional cost after access is provided.

We do not review plans, permits, recall lists, and/or government or local municipality documents. Information regarding recalled appliances, fixtures and any other items in this property can be found on the Consumer Product Safety website. These items may be present but are not reviewed.

Our recommendations are not intended as criticisms of the building, but as professional opinions regarding conditions present. As a courtesy, the inspector may list items that they feel have priority in the Executive Summary portion of the report. Although the items listed in this section may be of higher priority in the opinion of the inspector, it is ultimately the client's responsibility to review the entire report. If the client has questions regarding any of the items listed, please contact the inspector for further consultation.

Lower priority conditions contained in the body of the report that are neglected may become higher priority conditions. Do not equate low cost with low priority. Cost should not be the primary motivation for performing repairs. All repair and upgrade recommendations are important and need attention.

This report is a "snapshot" of the property on the date of the inspection. The structure and all related components will continue to deteriorate/wear out with time and may not be in the same condition at the close of escrow.

Anywhere in the report that the inspector recommends further review, it is strongly recommended that this be done PRIOR TO THE CLOSE OF ESCROW. This report is not intended for use by anyone other than the client named herein. No other persons should rely upon the information in this report. Client agrees to indemnify, defend and hold inspector harmless from any third party claims arising out of client's unauthorized distribution of the inspection report.

By accepting this inspection report, you acknowledge that you have reviewed and are in agreement with all of the terms contained in the standard contract provided by the inspector who prepared this report.

Page 15: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 14 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Introductory Notes

ORIENTATIONFor purposes of identification and reporting, the front of this building faces east.

For purposes of identification and reporting, the front of the building is the side containing the primary access.

NOTESThe house was estimated to be approximately 19 years old.

The weather was cloudy at the time of our inspection.

Over the course of this inspection the temperature was estimated to be between 40 and 50 degrees.

We make no representations as to the extent or presence of code violations, nor do we warrant the legal use of this building. This information would have to be obtained from the local building and/or zoning department.

A driveway and/or street is shared with other properties. To determine if maintenance-sharing or liability agreements are in effect regarding the driveway or street, consult the owner of the subject property, neighboring owners or public records.

There may be information pertinent to this property which is a matter of public record. A search of public records is not within the scope of this inspection. We recommend the client or their representative review all appropriate public records.

The scope of this inspection is limited to reasonably accessible areas. We make no attempt to move furnishings, stored personal property, and/or vegetation. Although no problems are anticipated, removal of these items may reveal reportable items.

Your inspector may choose to include photos in your inspection report. There are times when only a picture can fully explain the condition or if the client is unable to attend the inspection. Photo inclusion is at the discretion of the inspector and in no way is meant to emphasize or highlight the only conditions that were seen. We always recommend full review of the entire inspection report.

The home was occupied at the time of the inspection, with personal possessions and furniture in every room of the home that prohibited the inspection of some surfaces or systems. This includes numerous electrical outlets, lights, walls, floors, etc. We recommend further evaluation of the home if it becomes vacant, in order to more thoroughly evaluate the condition.

Exterior/Site/Ground

BASIC INFORMATIONGeneral lot topography: Hillside

Page 16: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 15 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Driveway: Concrete on grade

Walkways: Concrete

Primary exterior wall covering: Masonry Board

Primary exterior window material: Vinyl/plastic or vinyl clad

Page 17: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 16 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

FOUNDATION

Hairline and/or small cracks, within normal tolerances, are visible. This type of cracking is often a result of shrinkage of materials and/or minor settlement and usually does not affect the strength of the foundation. No action is indicated.

EXTERIOR PLUMBINGTesting of the irrigation system and/or automatic timer is beyond the scope of this inspection.

One or more exterior hose bibs in the landscaping were not operating. This may be due to a valve shut off or other reason. Recommend inquiring of homeowner as to the cause and repair as necessary.

Page 18: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 17 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

One or more hose bib(s) is/are dripping/leaking from the handle when operated. We recommend the washer be replaced and/or the packing nut be tightened.

OUTDOOR RECEPTACLESThe GFCI protection for the exterior receptacles is provided by a GFCI receptacle located in the garage. We advise testing on a monthly basis.

A receptacle cover plate at the front of the home is damaged. We recommend it be replaced during the course of normal maintenance.

OUTDOOR LIGHTSThe outdoor lights were tested and appeared functional at the time of the inspection.

Page 19: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 18 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

HARDBOARD SIDING

The masonry board siding shows routine wear but is generally in serviceable condition. We recommend minor maintenance to ensure maximum service life.

DOORS

Several exterior doors or door frames had some damage, primarily superficial. We recommend they be repaired or replaced.

GRADING

Grading is sloped toward the structure in some areas. Low spots and negative grading promote water accumulation near the building, leading to foundation problems. It is important that drains at the side of the home be monitored to ensure that proper draining is taking place during and after periods of heavy rain.

DRAINAGEA surface drainage system is designed to collect and divert roof runoff and other surface water. It is installed in solid pipe and flows continuously downhill to a point of discharge.

The surface water drainage system is below grade and cannot be viewed. Designs and materials for these systems vary widely, making it impossible to evaluate the integrity of the system with any certainty.

Page 20: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 19 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

We could not determine the discharge location of the drainage system. We suggest inquiries and/or observation during a heavy rain to discover the discharge location and effectiveness of the system.

The drainage system appears to be in serviceable condition, but one or more of the grates is clogged and would be ineffective in a heavy rain. We recommend that debris be cleaned from the grates and pipes be cleaned to ensure proper operation during heavy weather.

PUBLIC WORKSThe owner may have rights and responsibilities concerning the public improvements associated with this property. We suggest inquiries of the local public works department, particularly regarding liabilities for future maintenance costs.

The public sidewalks appear to be properly installed and are in serviceable condition.

Page 21: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 20 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

DRIVEWAY

The minor cracks in the driveway are of a cosmetic nature. However, they do indicate movement in the soil and, over time, may develop into an aesthetic issue and/or a safety concern because of tripping hazards.

WALKWAYSThe walkways appear to be properly installed and are in serviceable condition.

DECK

There are deteriorated deck boards at the surface of the rear deck, as well as on railings and other wood components, which may present a safety hazard if left unrepaired. We recommend replacement of all damaged material.

Page 22: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 21 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

RAILINGS

The railings at the rear deck may not be sturdy enough to resist a person's weight. We recommend that the railings be reinforced or replaced in accordance with present standards.

Page 23: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 22 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

FENCING

The fencing is generally serviceable but shows signs of routine wear and is in need of minor maintenance. Typically, fencing around the perimeter of the home is considered a shared responsibility between owners of adjacent properties. Recommend inquiring of neighbors prior to making repairs.

It should be stated that wood fences do have a finite service life. Maintaining the bases of the fence posts free and clear of rotting leaves, and an occasional treatment with a wood preservative will be most effective in prolonging service life.

GATES

The gates show signs of wear/deterioration and the need for maintenance in order for proper and continued operation.

Page 24: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 23 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

VEGETATION

Some trees or shrubberies were observed to be in contact with or near the siding or foundation. Recommend trimming back all trees and shrubberies at least 6 inches from the home in order to protect the home's surface from moisture or pest intrusion.

Page 25: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 24 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

TRIM

The trim at the several locations around the home is worn and in need of painting/caulking maintenance, or damaged/deteriorated. We recommend that trim be repaired and painted, and deteriorated wood trim be repaired or replaced. Note: Damaged siding or trim may act to hide further deterioration or defects within the wall. Only removing portions of the siding/trim and further evaluating the interior of the wall will fully reveal the extent of any hidden damage.

Page 26: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 25 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

FASCIA

Portions of the fascia are weathered, with blistered and/or peeling paint. This will require surface preparation and refinishing in the course of routine property maintenance to restore surface appearance.

EAVES/SOFFITS

At one or more locations we observed sagging sheathing at the eaves, indicating improper support or installation. We recommend repair to prevent damage to the roof surface or sheathing.

PAINT/STAIN

The exterior paint is in fair to good condition but appears a bit 'tired'. Except where noted otherwise, the need for painting is primarily cosmetic.

If caulking is needed for maintenance, or in preparation for the next paint job, we suggest a high quality urethane sealant such as 'Sikaflex'. Latex, butyl, oil based, silicone or 'architectural grade' sealants should be avoided on the exterior.

Page 27: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 26 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

In several locations around the home the caulking is in need of repair. Ensure that all gaps, particularly around penetrations including doors and windows, are properly caulked to prevent moisture intrusion or damage.

GENERAL COMMENTAs preventive maintenance, caulking and sealing the gaps in the exterior of the building around the doors, windows, plumbing and electrical entry points will help prevent heat loss, cold air infiltration and moisture entry.

If caulking is needed for maintenance of any flashing or exterior trim, we suggest a high quality urethane sealant such as 'Sikaflex'. Latex, butyl, oil based, silicone or 'architectural grade' sealants should be avoided.

There are areas where exterior features are in need of attention. These conditions suggest lapses in maintenance. We make no attempt to list all cosmetic flaws but, do suggest attention to items relating to function and safety.

Page 28: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 27 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Roofing

A roof system consists of the surface materials, connections, penetrations and drainage (gutters and downspouts). We visually review these components for damage and deterioration and do not perform any destructive testing. If we find conditions suggesting damage, improper application, or limited remaining service life, these will be noted. We may also offer opinions concerning repair and replacement. Opinions stated herein concerning the roof are based on a limited visual inspection. These do not constitute a warranty that the roof is, or will remain, free of leaks.

Composition Shingle

BASIC INFORMATIONLocation: Covers whole building

Roof slope: MediumMaterial: Asphalt composition shingleLayers: Single layerAge: Approximately 19+ years oldConnections and penetrations: Sealed with metal flashing

Roof drainage system: Gutters and downspouts

Page 29: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 28 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

INSPECTION METHODOur inspection of this roof was conducted from the roof surface. The inspector walked upon the surface and visually examined the accessible roofing components.

SURFACE

Some moss was growing on the roof surface. As a result, shingles can lift or be damaged. Leaks can result and/or the roof surface can fail prematurely if the moss is left to grow unabated. Efforts should be made to kill the moss during its growing season (wet months). Typically, zinc or phosphate based chemicals are used for this and must be applied periodically.

The roof surface is in generally functional condition, and no evidence of leaks were noted at present, across the surface we observed numerous indications of granulation loss, cracking or broken shingles (especially at the ridges where shingles are bent), and exposed nails or staples, puncturing the roof surface. These items indicate that the roof is older and in need of repairs in the near term. Recommend further evaluation by a licensed roofing professional to determine a course of action, as well as repairs of roof as needed to prolong the life of the roof surface and protect the home and continuing to monitor as the surface ages.

Page 30: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 29 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

FLASHINGS: OVERALLMetal flashing has been used to seal the connections and penetrations.

Page 31: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 30 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

In one or more locations the metal roof flashing is lifting up from the roof surface, leaving exposed nail holes. Recommend reattaching the flashing to the roof surface and patching any nail holes as needed.

CHIMNEY AT ROOF

Wood-framed chimneys are an often-neglected portion of the home's siding and trim. The siding and trim at the chimney at the roof is in marginal condition, with some maintenance needed. This maintenance includes painting and caulking, and may require the replacement of some siding or trim pieces as needed.

Page 32: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 31 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

PLUMBING VENTSOne or more plumbing vents at the roof are showing signs of tearing or warping at the neoprene flashing. Recommend replacement of any damaged plumbing flashings.

Page 33: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 32 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

OTHER VENTS

One of the vent caps or pipes is corroded. We recommend it be prepped and painted to restore its cosmetic appearance and prevent damage.

GUTTERSRoof runoff water is channeled to the downspouts by a metal gutter system attached to the fascia boards or to the ends of the rafters along the edge of the roof.

Debris and standing water was present in portions of the gutters, which limited our visual inspection. We recommend all debris be removed to ensure proper drainage. The condition of the gutters can be better assessed at that time.

Page 34: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 33 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

DOWNSPOUTSThe downspouts appear to be properly installed and in serviceable condition.

The downspouts terminate in subsurface drain lines. See comments under 'Drainage'.

GENERAL COMMENT

This roof is older and near the end of its expected service life. Although it is presently watertight, repairs are needed at present and the need for replacement should be expected within the next few years.

For further evaluation of the conditions of the roof we recommend you consult a licensed roofing contractor.

Page 35: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 34 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Garage

FRAMINGThe wall framing appears properly installed and, based on conventional construction standards, is adequate to resist lateral movement. The garage framing can usually serve as an indicator of the type and quality of the framing in general.

RECEPTACLESGFCI (ground fault circuit interrupter) protection has been installed providing an increased margin of safety. We recommend testing the device on a monthly basis.

GARAGE DOOR OPENERThe garage door opener(s) operated properly to raise and lower the doors, including the auto-reverse mechanisms, which stopped and reversed the direction of the doors when they struck objects in their path.

FLOORThe floor is a concrete slab.

Page 36: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 35 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

There are cracks in the floor slab with minor vertical displacement of the slab toward the middle of the garage. This is not a reflection on the condition of the rest of the building. No action is indicated.

GARAGE DOORSThe garage is equipped with two roll up doors.

Operation of one or more door(s) is controlled by a motorized mechanism, more commonly referred to as an automatic opener.

The garage doors were operated and appear to be properly installed and in generally serviceable condition.

Our review of the garage door(s) does not include resistance testing of the pressure switch and/or correct balance of the door springs. Further review by a specialty contractor is suggested.

FIRE SEPARATIONThe fire separation between the garage and the living space is without problems where visible. However, portions of the wall could not be inspected. With access, we recommend this wall be checked for any penetrations, and patched if necessary.

Page 37: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 36 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

PASSAGE DOORThe door between the garage and the living space seems to be of fire resistive construction as required by today's building standards and includes an approved automatic closer. This is a positive feature which provides a greater margin of safety.

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection. However, this area is in need of routine maintenance as noted above or in other sections of this report.

Due to the presence of personal belongings, access to portions of the area were effectively blocked at the time of our inspection. A 'walk-through' is recommended when the area is cleared and accessible.

Page 38: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 37 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Kitchen

The kitchen is visually inspected for proper function of components, active leakage, excessive or unusual wear, and general state of repair. We inspect built-in appliances to the extent possible using normal operating controls. Freestanding stoves are operated, but refrigerators, small appliances, portable dishwashers, and microwave ovens are not tested.

BASIC INFORMATIONEnergy: Gas (or propane) stove/oven with other electric appliancesVentilation: Exhaust ducted to the exteriorRefrigerators, wine coolers, and other cooling appliances are beyond the scope of this inspection

DRAIN TRAPSThe drain trap and associated piping are PVC plastic.

AIR GAPThe dishwasher drain is equipped with an air-gap fitting. This assures separation of the supply wat from the waste water.

Page 39: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 38 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

SINKThe sink is porcelain.

The sink appears to be properly installed. When operated, it was observed to be fully functional and in serviceable condition.

GAS SUPPLYThe gas piping for the appliance includes a local 90 degree shut-off valve for use in an emergency or in case of repair. The valve was not tested at the time of inspection, but is of a type usually found to be serviceable.

The gas connector is an approved flexible type in good condition.

RECEPTACLESThe receptacles appear to be properly installed and were operational.

GFCI (ground fault circuit interrupter) protection has been installed providing an increased margin of safety. We recommend testing the device on a monthly basis.

LIGHTSThe overhead kitchen lights were tested and found to be operational at the time of the inspection.

Page 40: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 39 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

HEAT OUTLETThe heating outlet is in serviceable condition. Conditioned air was observed flowing into the room when the heating system was operated.

FLOORThe wood or laminate flooring is in serviceable condition. Kitchen floors receive the most concentrated wear of any area in the house, especially at the sink and stove. We recommend these areas be coated every two to three years as preventive maintenance.

CABINETS

The cabinets are in serviceable condition. Several of the doors need adjustment of hinges and latches for smoother operation.

COUNTERTOPSThe countertop is tile.

We suggest the use of a quality sealant such as 'GE Sanitary Silicone' or 'Dow Corning 786' for caulking. Latex and 'latex with silicone' sealants are inferior materials and their use is strongly discouraged.

Page 41: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 40 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

The caulk/grout at the joint between the countertop and the wall is cracking and discolored. Recommend replacing caulk/grout to prevent moisture intrusion behind the countertop and cabinet.

VENTILATIONKitchen ventilation is provided by a unit that draws air downward through a fan next to the range burners, venting to the exterior. The fan appears to be properly installed and in serviceable condition.

Page 42: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 41 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

STOVEThe stove was turned on with the normal operating controls and found to be in satisfactory working condition.

OVENThe oven was turned on with the normal operating controls and found to be in satisfactory working condition.

DISPOSALThe disposal was turned on with normal user controls and observed to be in satisfactory working condition.

Page 43: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 42 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

DISHWASHER

The dishwasher is not properly attached to the cabinets. We recommend it be attached according to the manufacturer's installation instructions.

The dishwasher door and control panel had minor damage/cracking. Recommend repair as needed.

Page 44: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 43 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

MICROWAVE

The built-in microwave was not operating using normal controls. Recommend further evaluation and repair.

GENERAL COMMENTThis area is in need of repair as noted above or in other sections of this report.

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Laundry Area

Laundry areas and/or laundry rooms are visually inspected for general state of repair. Due to their hidden nature, we do not review appliances, connections, hookups, or venting.

Page 45: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 44 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

HEAT OUTLETThe heating outlet is in serviceable condition. Conditioned air was observed flowing into the room when the heating system was operated.

DRYER VENTThe dryer vent appears properly installed and in serviceable condition.

Page 46: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 45 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

WASHER/DRYERThe hookups for the washer and dryer are properly installed and in serviceable condition. The appliances themselves were not tested.

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection. However, this area is in need of routine maintenance as noted above or in other sections of this report.

Page 47: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 46 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Mud Room

DRAIN TRAPThe drain trap and associated piping are PVC plastic.

LAUNDRY TUBThe laundry tub is plastic.

The laundry tub is properly installed and in serviceable condition.

Page 48: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 47 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection.

Bathroom

Bathrooms are visually inspected for proper function of components, active leakage, excessive or unusual wear and general state of repair. Fixtures are tested using normal operating features and controls. Due to finished surfaces such as drywall/plaster, tile, and flooring, much of the bathroom is considered inaccessible. We do not test or confirm proper application of secondary equipment including but not limited to steam units, spa tubs, heated towel bars, etc.

Main Floor Half Bath

BASIC INFORMATIONToilet: Ceramic unit with a porcelain finish

Page 49: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 48 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Wash basin: Ceramic unit with a porcelain finish

DRAIN TRAPThe drain trap and associated piping are PVC plastic.

TOILETThe toilet was flushed and appeared to be functioning properly.

WATER BASINThe wash basin appears to be properly installed. When operated, it was observed to be fully functional and in serviceable condition.

RECEPTACLESThe receptacle appears to be properly installed and was operational.

GFCI (ground fault circuit interrupter) protection has been installed providing an increased margin of safety. We recommend testing the device on a monthly basis.

Page 50: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 49 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

BATHROOM FLOORThe floor appears to be properly installed and is in serviceable condition.

VENTILATIONVentilation in this bathroom is provided by a ceiling fan. This fan was operated and was found to be working satisfactorily.

Page 51: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 50 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection.

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Second Floor Hallway

BASIC INFORMATIONToilet: Ceramic unit with a porcelain finish

Page 52: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 51 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Wash basin: Pressed steel unit with a porcelain finish

Bathtub: Pressed steel with a porcelain finish

Shower walls: Mortar set ceramic tile

Page 53: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 52 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

DRAIN TRAPThe drain trap and associated piping are PVC plastic.

TOILETThe toilet was flushed and appeared to be functioning properly.

WATER BASIN

The drain stop is defective. We recommend it be repaired or replaced.

BATHTUBThe bathtub appears to be properly installed and in serviceable condition.

SHOWERThe shower was operated for the inspection and appeared to be in serviceable condition.

RECEPTACLESThe receptacle appears to be properly installed and was operational.

GFCI (ground fault circuit interrupter) protection has been installed providing an increased margin of safety. We recommend testing the device on a monthly basis.

Page 54: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 53 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

The GFCI protection for this bathroom is provided by a GFCI receptacle located in the first floor half bathroom. We advise testing on a monthly basis.

HEAT OUTLETThe heating outlet is in serviceable condition. Conditioned air was observed flowing into the room when the heating system was operated.

SHOWER WALLS

Recommend sealing the grout in the bathroom shower. This is an item of regular maintenance that will help prolong the life of the shower wall and floor materials.

BATHROOM FLOORThe floor appears to be properly installed and is in serviceable condition.

It is important to maintain the caulking around bathtubs and showers, especially at the intersection between the tub or shower and the floor. Failure to maintain this seal will often result in damage to flooring materials, subflooring and framing.

Page 55: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 54 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Particle board trim pieces at the bathroom floor showed signs of swelling. This is typical when this type of trim is used in bathrooms, as it is highly susceptible to moisture. Recommend replacing trim as warranted.

CABINETS

The cabinets are in serviceable condition. Several of the doors need adjustment of hinges and latches for smoother operation.

Page 56: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 55 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

COUNTERTOPS

Caulking at the countertop/backsplash joint is cracking. Recommend recaulking to prevent moisture damage.

VENTILATIONVentilation in this bathroom is provided by a ceiling fan. This fan was operated and was found to be working satisfactorily.

Page 57: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 56 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

GENERAL COMMENTThis area is in need of repair as noted above or in other sections of this report.

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Second Floor Master

BASIC INFORMATIONToilet: Ceramic unit with a porcelain finish

Page 58: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 57 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Wash basins: Pressed steel units with a porcelain finish

Bathtub: Molded fiberglass

Shower walls: Mortar set ceramic tile

Page 59: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 58 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

DRAIN TRAPThe drain trap and associated piping are PVC plastic.

TOILETThe toilet was flushed and appeared to be functioning properly.

WATER BASINThe wash basins appear to be properly installed. When operated, they were observed to be fully functional and in serviceable condition.

BATHTUB

Caulking or grout around the perimeter of the bathtub or surround is cracked or missing in several areas. Ensure all joints and gaps are fully sealed to prevent moisture damage.

SHOWERThe shower was operated for the inspection and appeared to be in serviceable condition.

Page 60: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 59 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

The showerhead was not installed correctly and leaked from the fitting when operated. Recommend reinstalling.

RECEPTACLESThe receptacles appear to be properly installed and were operational.

GFCI (ground fault circuit interrupter) protection has been installed providing an increased margin of safety. We recommend testing the device on a monthly basis.

The GFCI protection for this bathroom is provided by a GFCI receptacle located in the first floor half bathroom. We advise testing on a monthly basis.

HEAT OUTLETThe heating outlet is in serviceable condition. Conditioned air was observed flowing into the room when the heating system was operated.

SHOWER WALLSThe shower walls appear to be properly installed and generally in serviceable condition, with exceptions noted below.

Page 61: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 60 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Recommend sealing the grout in the bathroom shower. This is an item of regular maintenance that will help prolong the life of the shower wall and floor materials.

GLASS ENCLOSURE

The sliding glass shower door was difficult to operate and is in need of maintenance/adjustment for full operation.

COUNTERTOPSThe countertop is tile.

The countertop shows typical wear and tear, normal for this heavily used component. We considered the flaws cosmetic in nature with no action indicated.

Page 62: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 61 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

VENTILATION

The exhaust fan is very noisy and is not likely to be used in its present condition. We recommend that it be serviced or replaced to restore quite operation.

GENERAL COMMENTThis area is in need of repair as noted above or in other sections of this report.

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Bedroom

Second Floor Master

RECEPTACLESThe receptacles were found to be properly installed and in serviceable condition. The number of receptacles is considered adequate for the size of the room.

Page 63: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 62 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

LIGHTS / FANThere is no ceiling fixture in this room. Building practices require the ability to turn on a light from a switch in every room. In this case, one of the receptacles is connected to the switch, allowing control of a cord connected lamp.

HEAT OUTLETThe heating outlet is in serviceable condition. Conditioned air was observed flowing into the room when the heating system was operated.

CEILING

There are ceiling and wall cracks that appear outside of the range of normal. These can be patched, prepared and finished in the course of routine maintenance. It should be understood that this type of cosmetic cracking may recur due to minor movement in the structure. Continue to monitor and if cracks appear to grow, recommend further evaluation.

FLOORThe floors are covered with wall-to-wall carpet. No attempt was made to determine the type or condition of the material under the carpet.

Page 64: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 63 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

DOORS

The door is missing its door stop. We recommend a stop or bumper be installed to prevent damage to the surfaces behind the door.

SMOKE DETECTORThe smoke detector alarm was properly located and appeared adequately installed.

Page 65: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 64 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

GENERAL COMMENTThis area is in need of repair as noted above or in other sections of this report.

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Second Floor Southeast

RECEPTACLESThe receptacles were found to be properly installed and in serviceable condition. The number of receptacles is considered adequate for the size of the room.

LIGHTS / FANThe bedroom lights and/or fan were tested using normal controls and appeared to be functioning properly.

HEAT OUTLETThe heating outlet is in serviceable condition. Conditioned air was observed flowing into the room when the heating system was operated.

Page 66: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 65 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

WALLS

The wall and window frame area on the south side of the home shows signs of warping and unusual settlement. Though the cause of this condition was not determined, we recommend repairs to restore cosmetic appearance, and continuing to monitor this area for any signs of unusual movement. Further evaluation would be recommended if the condition worsens.

FLOORThe floors are covered with wall-to-wall carpet. No attempt was made to determine the type or condition of the material under the carpet.

Page 67: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 66 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

CLOSET DOORS

The door does not slide properly, indicating portions of the hardware are not properly installed. We recommend repair or replacement.

SMOKE DETECTORThe smoke detector alarm was properly located and appeared adequately installed.

Page 68: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 67 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

GENERAL COMMENTThis area is in need of repair as noted above or in other sections of this report.

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Second Floor Middle

RECEPTACLESThe receptacles were found to be properly installed and in serviceable condition. The number of receptacles is considered adequate for the size of the room.

LIGHTS / FANThe bedroom lights and/or fan were tested using normal controls and appeared to be functioning properly.

HEAT OUTLETThe heating outlet is in serviceable condition. Conditioned air was observed flowing into the room when the heating system was operated.

Page 69: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 68 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

FLOORThe floors are covered with wall-to-wall carpet. No attempt was made to determine the type or condition of the material under the carpet.

SMOKE DETECTORThe smoke detector alarm was activated when the test button was depressed.

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection. However, this area is in need of routine maintenance as noted above or in other sections of this report.

Living Room

RECEPTACLESThe receptacles were found to be properly installed and in serviceable condition. The number of receptacles is considered adequate for the size of the room.

Page 70: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 69 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

LIGHTSThe lights and/or ceiling fan in this room were tested using standard operating controls and appeared to operate properly.

HEAT OUTLETThe heating outlet is in serviceable condition. Conditioned air was observed flowing into the room when the heating system was operated.

WALLS

There are minor wall and ceiling cracks. These can be patched, prepared and finished in the course of routine maintenance. It should be understood that this type of cosmetic cracking may recur due to minor movement in the structure.

Page 71: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 70 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

FLOORThe floors are covered with wall-to-wall carpet. No attempt was made to determine the type or condition of the material under the carpet.

DOORS

The exterior living room door hardware is damaged or not operating properly. The deadbolt is not operating and the hardware to open half of the door is missing. We recommend repair or replacement of the door and/or hardware.

Page 72: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 71 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

FIREPLACE

Home inspectors are not certified the chimney professionals. Only a level 2 inspection performed by a CSIA (Chimney Safety Institute of America) certified chimney sweep can determine the condition of the flue and whether the fireplace is safe to use. Recommend a Level 2 inspection and cleaning/servicing of the fireplace and chimney flues by a qualified professional. Clean chimneys don't catch on fire.

Some erosion of the firebricks is normal over time. In this case, the back of the firebox is deeply eroded and past its useful service life. We recommend the firebricks be replaced.

For attention to the condition(s) noted above, and/or cost estimates, if necessary, we recommend the advice and services of a NCSG certified chimney specialist.

Page 73: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 72 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

GENERAL COMMENTThis area is in need of repair as noted above or in other sections of this report.

Family/Dining Room

RECEPTACLESThe receptacles were found to be properly installed and in serviceable condition. The number of receptacles is considered adequate for the size of the room.

LIGHTSThere is no ceiling fixture in portions of this room. Building practices require the ability to turn on a light from a switch in every room. In this case, one of the receptacles is connected to the switch, allowing control of a cord connected lamp.

Page 74: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 73 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

HEAT OUTLETThe heating outlet is in serviceable condition. Conditioned air was observed flowing into the room when the heating system was operated.

WALLS

The wall and window frame area on the south side of the home shows signs of warping and unusual settlement. In the family room this has led to the window being difficult to operate. Though the cause of this condition was not determined, we recommend repairs to restore cosmetic appearance, and continuing to monitor this area for any signs of unusual movement. Further evaluation would be recommended if the condition worsens.

Page 75: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 74 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

FLOORThe wood flooring is mostly covered by carpeting. The visible areas are serviceable, but we made no attempt to uncover and examine the entire floor.

GENERAL COMMENTThis area is in need of repair as noted above or in other sections of this report.

Page 76: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 75 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Library/Office

RECEPTACLESThe receptacles were found to be properly installed and in serviceable condition. The number of receptacles is considered adequate for the size of the room.

HEAT OUTLETThe heating outlet is in serviceable condition. Conditioned air was observed flowing into the room when the heating system was operated.

FLOORThe floors are covered with wall-to-wall carpet. No attempt was made to determine the type or condition of the material under the carpet.

Page 77: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 76 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

DOORS

The door is not properly aligned in the frame and doesn't latch. We recommend adjustments to the hardware or frame to restore proper function.

GENERAL COMMENTThis area is in need of repair as noted above or in other sections of this report.

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Interior

Our review of the interior includes inspection of walls, ceilings, floors, doors, windows, steps, stairways, balconies and railings. These features are visually examined for proper function, excessive wear and general state of repair. Some of these components may not be visible/accessible because of furnishings and/or storage. In such cases these items are not inspected.

BASIC INFORMATIONNumber of bedrooms: ThreeNumber of bathrooms: Two and one-half

Page 78: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 77 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Window material: VinylWindow type: Horizontal and Vertical sliding windowsWindow glazing: Double paneFinished ceiling material: DrywallFinished floor material: Carpet and wood or laminateFinished wall material: Drywall

SURFACES: OVERALL

There is wear and tear throughout the house, of the type generally resulting from age and heavy use. We make no attempt to list all cosmetic flaws and suggest that most of these deficiencies will be addressed by routine maintenance and upgrading.

WALLS & CEILINGS

There are minor cracks in the walls and/or ceilings. This is a common condition with this type of construction and does not indicate a structural deficiency. The cracks can be repaired or painted over during routine maintenance.

FLOORS: OVERALLThere are cosmetic floor blemishes which can be eliminated in the course of routine maintenance.

STAIRSThe stairs were used several times during the inspection. The various components appear to be properly installed and no deficiencies were noted during use. The handrails were securely attached.

RAILINGSThe railings appear to properly installed and are in serviceable condition.

DOORS: OVERALLThe interior doors appear to be properly installed and in good condition, with exceptions noted below.

WINDOWS: OVERALLWe operate a representative sample of the windows, but do not necessarily open, close, and latch every window. Our inspection standards require testing a minimum of one window in every room.

Page 79: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 78 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

The windows tested appear to be properly installed and generally in serviceable condition, with exceptions noted below or elsewhere in this report.

DETECTORS: OVERALLThe smoke detectors were inspected for location only. For future reference, testing with only the built-in test button verifies proper battery and horn function, but does not test the smoke sensor. We advise testing with real or simulated smoke.

Carbon monoxide detectors were not found in the home. Typical building practice calls for at least one CO detector per floor of living space. Recommend installing CO detectors due to safety concerns.

We note that the detectors present were visibly older - it is recommended that smoke detectors be replaced every 10 years in order to ensure proper operation, in addition to batteries being replaced every 6 months. Recommend replacing all detectors in this home with newer models.

HEAT SOURCEWe observed a permanent heat source in each room throughout the building.

GENERAL COMMENTThe interior surfaces, hardware, fixtures, doors and windows appear to be properly installed and generally in serviceable condition, with exceptions noted above.

We make no attempt to list all cosmetic flaws and suggest that most of these deficiencies will be addressed by normal maintenance and upgrading.

Attic

The attic contains the roof framing and serves as a raceway for components of the mechanical systems. There are often heating ducts, electrical wiring and appliance vents in the attic. We visually examine the attic components for proper function, excessive or unusual wear, general state of repair, leakage, venting and misguided improvements. Where walking in an unfinished attic can result in damage to the ceiling, inspection is from the access opening only.

Page 80: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 79 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

ACCESS/ENTRYThe attic access is located in the master bedroom closet.

SHEATHINGThe roof sheathing is 'OSB' - Oriented Strand Board, nailed solidly across the rafters.

The roof sheathing appears to be properly installed and in good condition.

ROOF TRUSSESRoof trusses support the roof sheathing and roof covering, transferring loads to the bearing walls. The bottom of a truss supports the finished ceiling. Trusses are usually engineered components assembled in a factory and delivered to the site.

Page 81: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 80 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

The trusses are generally in good condition, where seen, and have performed adequately since their installation.

VENT LINESThe vent piping for the waste system appears to be properly installed and in good condition.

DUCTSThe ducts appear to be properly installed and are in serviceable condition.

VENTILATIONOur feeling regarding attic ventilation is that 'you can never have too much'. Attic ventilation can be provided by eave, gable, and ridge vents as well as by automatic and wind driven fans. We encourage use of any or all of the above.

The attic appeared to be adequately vented (though different temperature or weather conditions may reveal inadequacies in the attic venting). Good ventilation helps reduce attic moisture levels and prevents condensation on the underside of the roof. In addition, it reduces heat build-up in the attic, making the house more comfortable.

Page 82: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 81 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Crawl Space

The crawl space is where most of the building's structural elements and portions of its mechanical systems are located. These include foundation, structural framing, electrical, plumbing and heating. Each accessible and visible component and system is examined for proper function, excessive or unusual wear and general state of repair. It is not unusual to find occasional moisture and dampness in crawl spaces. Significant and/or frequent water accumulation can adversely affect the building foundation and support system and would indicate the need for further evaluation by a specialist. Although observed in the crawl space, some items will be reported under the individual systems to which they belong.

BASIC INFORMATIONFoundation type: Raised perimeter with isolated piersFoundation material: Poured concreteMudsill: Bolted to foundationWall system: Wood stud wallsFloor system: Wood joists support by beams

ACCESSThe crawl space is accessible from an exterior door into a partially finished "basement", and then from a second door into the crawlspace.

Page 83: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 82 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

There is a very large drop from the basement door into the crawlspace. We recommend the installation of a permanent stairs or ladder for easier access.

FOUNDATIONHairline and/or small cracks, within normal tolerances, are visible. This type of cracking is often a result of shrinkage of materials and/or minor settlement and usually does not affect the strength of the foundation. No action is indicated.

MUDSILLThe mudsill is the first wood member of the framing, resting directly on the foundation. The accessible sections of mudsill are in good condition.

Page 84: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 83 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

WALL FRAMINGIn the areas where the wall framing is visible, all components appear to be properly installed and generally in good condition, with exceptions noted below:

Portions of the exterior wall sheathing and/or framing was showing signs of moisture-related damage below the dryer vent. We recommend further evaluation to determine the cause of this damage, and replacement of any damaged materials.

FLOOR JOISTSIn the areas where the floor framing is visible, all components appear to be properly installed and in good condition.

POSTSThe floor system is supported by wooden posts set over concrete pier blocks.

Page 85: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 84 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

ANCHOR BOLTSAnchor bolts are fasteners that connect the wood framing to the foundation. They limit the framing's ability to move independently on the foundation in the event of seismic activity.

Anchor bolts are in place and appear to be properly installed and in good condition.

HOLD DOWNSHoldowns are structural hardware connections that tie the support framing to the foundation. They strengthen the structure and allow it to resist lateral forces and uplift during an earthquake.

Holdowns have been installed. They appear to be properly installed and in good condition, but we cannot verify their proper number or location.

Page 86: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 85 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

MOISTUREThe soil was dry at the time of our inspection, and there were no adverse conditions or damage observed related to excessive moisture.

VAPOR BARRIERThe soil has been covered with plastic sheeting, probably installed in an attempt to reduce moisture levels in the crawl space atmosphere. This is considered a beneficial feature and is required in some jurisdictions.

VENTILATIONVentilation in the crawl space is adequate. Good ventilation in the crawl space is important to keep moisture levels down. Keeping the vents clear of debris and vegetation should be part of regular maintenance.

PEST CONTROL

Containers of bait and/or traps have been placed in the crawl space, indicating past problems with rodents. No obvious recent activity was evident and it might be assumed that this problem has been solved.

DUCTSThe ducts appear to be properly installed and are in serviceable condition.

FLOOR INSULATION

There are fiberglass batts that have fallen out of place. We recommend this material be secured back in place.

Page 87: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 86 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

GENERAL COMMENTThe conditions observed and noted above, if left unattended, may effect the performance of the foundation or the health/safety of the occupants. Recommend further evaluation and repair of any items noted above.

Plumbing

A plumbing system consists of the domestic water supply lines, drain, waste and vent lines and gas lines. Inspection of the plumbing system is limited to visible faucets, fixtures, valves, drains, traps, exposed pipes and fittings. These items are examined for proper function, excessive or unusual wear, leakage, and general state of repair. The hidden nature of piping prevents inspection of every pipe and joint. A sewer lateral test, necessary to determine the condition of the underground sewer lines, is beyond the scope of this inspection If desired, a qualified individual could be retained for such a test. Our review of the plumbing system does not include landscape watering, fire suppression systems, private water supply/waste disposal systems, or recalled plumbing supplies. Review of these systems requires a qualified and licensed specialist.

BASIC INFORMATIONDomestic water source: Public supply

Landscape water source: Public supplyMain water line: Copper

Supply piping: Copper where seen

Page 88: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 87 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Waste disposal: Private on-site disposal

Waste piping: Plastic where seen

Water pressure: Mid-range of normal water pressure

Other installed systems: Landscape watering, not inspected

WATER SHUTOFF LOCATIONThe domestic water supply shut-off valve is in the garage behind the water heater.

Page 89: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 88 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

WATER SHUTOFF COMMENTSThe main shut-off valve was located but testing the operation of this valve is not within the scope of our inspection. Operation of the valve from time to time will keep it functional and maximize its useful life.

MAIN SUPPLYThere was no evidence of surface corrosion or leakage at the exposed and accessible main supply.

INTERIOR SUPPLYThe exposed and accessible supply piping generally appears to be properly installed and in good condition.

The extent of copper plumbing is unknown. Consultation with the owner/occupant and/or a licensed plumbing contractor is recommended if more information regarding the existing supply piping is desired.

WATER PRESSUREThe system water pressure, as measured at the exterior hose bibs, is within the range of normal.

DRAIN LINESThe visible drain piping appears to be properly installed and in serviceable condition.

SEWER CLEANOUTThe sewer cleanout is located in the crawl space.

VENT LINESThe vent piping for the waste system appears to be properly installed and in good condition.

PRIVATE DISPOSALThis property uses a private waste disposal system, investigation of which is beyond the scope of this inspection. If accurate service records are not available, it is strongly recommended that the septic tank be pumped and inspected by an expert.

Whether or not further inspection is necessary, consultation with a septic tank service company is suggested to determine a probable pumping schedule and to discuss the 'do's and don'ts' of septic systems.

GAS PIPINGThe gas piping appears to be properly installed and in serviceable condition. We detected no evidence of leakage at any of the exposed gas piping. Pressure testing may reveal leaks, but this procedure is beyond the scope of our inspection.

Page 90: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 89 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

GAS METER LOCATIONThe gas meter is outside on the right side of the building. The main gas supply shutoff valve is located on the riser pipe between the ground and the meter. This valve should be turned 90 degrees (either way) in order to shut off the gas.

GENERAL COMMENTThe plumbing system appears to be in good condition.

A representative number of fixtures were operated and we observed reasonable flow when other fixtures were operated simultaneously.

A representative number of drains were tested and each emptied in a reasonable amount of time and did not overflow when other fixtures were drained simultaneously.

The supply piping is copper. Copper is generally considered a very desirable type of piping and is expected to last the lifetime of the building.

Water Heater

Our review of water heaters includes the tank, water and gas connections, electrical connections, venting and safety valves. These items are examined for proper function, excessive or unusual wear, leakage and general state of repair. We do not fully review tankless/on-demand systems and suggest you consult a specialist. The hidden nature of piping and venting prevents inspection of every pipe, joint, vent and connection.

Page 91: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 90 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

BASIC INFORMATIONLocation: In the garage

Energy source: Natural gasCapacity: 50 gallonsAge: Estimated to be 2+ years oldUnit type: Free standing tankWater heater temperature settings should be maintained in the mid-range to avoid injury from scalding

T/P RELEASE VALVEThe water heater is equipped with a temperature and pressure relief valve. This device is an important safety device and should not be altered or tampered with. We observed no adverse conditions.

Page 92: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 91 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

EXPANSION TANKThe water heater is equipped with an expansion tank that appears properly installed and in serviceable condition. However, review of this equipment is beyond the scope of this inspection.

GAS SUPPLYThe gas piping for the appliance includes a local 90 degree shut-off valve for use in an emergency or in case of repair. The valve was not tested at the time of inspection, but is of a type usually found to be serviceable.

The gas connector is an approved flexible type in good condition.

Page 93: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 92 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

VENTINGThe water heater vent is properly installed and appears in serviceable condition.

COMBUSTION AIRCombustion air provides the oxygen for fuel burning appliances. Adequate ventilation around all fuel burning appliances is vital for their safe operation. The air can come from inside or outside, providing industry standards are met.

The combustion air supply is adequate.

BURNERSThe burner is generally clean and appears to be in serviceable condition.

WATER CONNECTORSThe cold water inlet and hot water outlet connections appear properly installed and in serviceable condition.

SEISMIC RESTRAINTThe water heater tank has been secured. This feature will help prevent water heater movement and possible gas leakage, limit damage and provide a source of usable domestic water in the event of a major earthquake.

ELEVATION/LOCATIONThe water heater has been elevated above the garage floor in accordance with present standards. This is a beneficial configuration which helps prevent the ignition of fumes from spilled flammable liquids.

INSULATIONThere is no insulation blanket installed. Newer water heaters have built-in insulation to meet rigorous conservation standards. Installation of a blanket can be done but offers very little improvement on the existing efficiency of the unit.

Page 94: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 93 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

GENERAL COMMENTThis is a newer water heater, was operating and with routine maintenance should be reliable for a number of years.

Heat

A heating system consists of the heating equipment, operating and safety controls, venting and the means of distribution. These items are visually examined for proper function, excessive or unusual wear and general state of repair. This is a non-evasive, basic function review only. We do not dismantle, uncover or calculate efficiency of any system. Regular servicing and inspection of heating systems is encouraged.

Page 95: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 94 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Forced Hot Air

BASIC INFORMATIONFurnace location: Garage

Energy source: Natural gasFurnace btu input rating: 120,000 btu'sAge: 19+ years oldManufacturer: Lennox

SYSTEM NOTESForced air furnaces operate by heating a stream of air moved by a blower through a system of ducts. Important elements of the system include the heat exchanger, exhaust venting, blower, controls, ducting, and combustion air supply.

GAS SUPPLYThe gas piping includes a 90 degree shutoff valve for emergency use. The valve was not tested at the time of inspection. This age and style of valve is normally found to be operable by hand and generally trouble free.

The gas connector is an approved flexible type in good condition.

Page 96: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 95 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

BURNERSThe burners were inspected and found to be clean and in good working order.

HEAT EXCHANGERThe heat exchanger was inaccessible and could not be visually examined.

IGNITION SYSTEMThe heating unit is equipped with an electronic ignition system, which is an energy saving feature that allows operation without the need for a continuously burning pilot light.

AIR FILTERSThe air filter for the heating unit is a conventional, disposable filter.

The filter has accumulated significant debris which decreases its effectiveness and blocks air flow. This can dramatically decrease the efficiency of the heating system. We recommend the filter be removed, cleaned and replaced if necessary.

CLEARANCEThere is adequate clearance to combustible materials in the area around the heating unit as long as the space is not used for storage. We encourage good housekeeping practices in this area.

Page 97: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 96 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

VENTThe heating system vent is properly installed and appears in serviceable condition where seen.

COMBUSTION AIRCombustion air provides the oxygen for fuel burning appliances. Adequate ventilation around all fuel burning appliances is vital for their safe operation. The air can come from inside or outside, providing industry standards are met.

There is adequate combustion air for this heating unit.

DUCTSThe ducts appear to be properly installed and are in serviceable condition.

THERMOSTATThe thermostat appears to be properly installed and the unit responded to the basic controls. This is a programmable device with many options for setback settings, timed events, etc. No attempt was made to test all functions of the thermostat.

HVAC WIRINGAll accessible wiring appears in good condition.

GENERAL COMMENTThe heating system responded to normal operating controls. Components appear to be properly installed and serviceable. This is an older system showing normal wear and tear, but we noted no conditions considered to be out of the ordinary.

Our inspection of the heating system is non-invasive and is limited to visible components and their basic function. A full evaluation requires extensive testing and is beyond the scope of our inspection.

Page 98: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 97 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

The last service date of the gas forced air furnace appeared to be more than 1 year ago, or the inspector was unable to determine the last service date. Ask the property owner when it was last serviced. If unable to determine the last service date, or if last service date was more than one year ago, recommend that a qualified HVAC technician inspect, clean, and service the system, and make repairs if necessary. For safety reasons, and because the system is fueled by gas, this servicing should be performed annually in the future. Any needed repairs noted in this report should be brought to the attention of the HVAC technician when it is serviced.

Electrical System

An electrical system consists of the service, distribution, wiring and convenience outlets (switches, lights, and receptacles). Our examination of the electrical system includes the exposed and accessible conductors, branch circuitry, panels, overcurrent protection devices, and a random sampling of convenience outlets. We look for adverse conditions such as improper installation, exposed wiring, running splices, reversed polarity and circuit protection devices. We do not evaluate fusing and/or calculate circuit loads. The hidden nature of the electrical wiring prevents inspection of every length of wire.

BASIC INFORMATIONService entry into building: Underground service lateralVoltage supplied by utility: 120/240 voltsCapacity (available amperage): 200 amperesBranch circuit protection: Circuit breakersWiring method: Non-metallic sheathed cable or 'romex'

ELECTRIC METERThe electric meter is outside on the right side of the building.

Page 99: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 98 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

MAIN SERVICEThe main electrical service panel is in the garage.

MAIN DISCONNECTThe main disconnect is incorporated into the electrical service panel.

MAIN DISCONNECTThe ampacity of the main disconnect is 200 amps.

Page 100: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 99 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

CB MAIN PANELThe main service panel is in good condition with circuitry installed and fused correctly.

Some of the panel cover screws are missing. We recommend proper, blunt-end screws be installed.

The circuits in the panel are labeled. We did not verify the accuracy of the labeling, but it appears to be typical. When the opportunity arises, we suggest checking the labeling by actually operating the breakers.

SERVICE CAPACITYThe service entrance conductors are the wires between the utilities service drop and the main service disconnect or main service panel.

The service entrance conductors appear to be #4/0 Aluminum providing an ampacity of 200.

Our statement regarding service capacity is based upon the labeled rating of the main electrical service disconnect.

The service capacity is normal for a house this size and age, and appears adequate for the present demand and minor additional loads.

BRANCH CIRCUITRYThe accessible branch circuitry was examined and appeared properly installed and in serviceable condition.

RECEPTACLES: OVERALLFor reference, as receptacles are discussed in this report, present standards for typical room plugs require grounded, 3 prong receptacles within six feet of any point on all walls. Upgrading is required in older buildings only during remodeling.

Based upon our inspection of a representative number, the receptacles were found to be properly installed for the time of construction, in serviceable condition, and operating properly.

SWITCHES: OVERALLWe checked a representative number of switches and found they were operating and in serviceable condition.

Page 101: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 100 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

LIGHTS: OVERALLThe light fixtures in this building are generally in serviceable condition.

GFI PROTECTIONGFCI (ground fault circuit interrupter) protection is a modern safety feature designed to prevent shock hazards. GFCI breakers and receptacles function to de-energize a circuit or a portion of a circuit when a hazardous condition exists.

GFCI protection is inexpensive and can provide a substantial increased margin of safety.

GFCI protection is installed for all of the receptacles where this type of protection is presently required. We recommend testing these devices on a monthly basis.

GENERAL COMMENTThe electrical system is in good condition and the components are properly installed. No unsafe conditions were observed in the readily accessible portions of the installation.

Insulation/Energy

Insulation, weatherstripping, dampers, double-glazed glass and set-back thermostats are features that help reduce heat loss and/or gain and increase system and appliance efficiency. Our visual inspection includes review to determine if these features are present in representative locations and we may offer suggestions for upgrading. Our review of insulation is based upon uniformly insulated or are insulated to current standards. It is our opinion that all homes could benefit from energy conservation upgrades, and we suggest that you consult professionals.

ATTIC INSULATIONThe attic has blown-in cellulose insulation.

The level of insulation would appear to provide an R-30 insulating value. This provides very good resistance to heat transfer by present standards.

WALL INSULATIONWe were unable to access the wall cavities and/or determine the presence or condition of insulation.

FLOOR INSULATION

There are fiberglass batts that have fallen out of place. We recommend this material be secured back in place.

GENERAL COMMENTThe structure appears to be generally adequately insulated, given the age of the home. Though some minor repairs or upgrades could be made, the energy efficiency of the home is generally considered adequate.

Page 102: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 101 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

Locations of Emergency Controls

In an emergency, you may need to know where to shut off the gas, the water and/or the electrical system. We have listed below these controls and their location for your convenience. We urge that you familiarize yourself with their location and operation.

WATER SHUTOFF LOCATIONPLUMBINGThe domestic water supply shut-off valve is in the garage behind the water heater.

SEWER CLEANOUTPLUMBINGThe sewer cleanout is located in the crawl space.

GAS METER LOCATIONPLUMBINGThe gas meter is outside on the right side of the building. The main gas supply shutoff valve is located on the riser pipe between the ground and the meter. This valve should be turned 90 degrees (either way) in order to shut off the gas.

Page 103: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 102 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

ELECTRIC METERELECTRICAL SYSTEMThe electric meter is outside on the right side of the building.

MAIN SERVICEELECTRICAL SYSTEMThe main electrical service panel is in the garage.

Page 104: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

Page 103 of 124Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-03028

MAIN DISCONNECTELECTRICAL SYSTEMThe main disconnect is incorporated into the electrical service panel.

Environmental Concerns

Environmental issues include but are not limited to radon, fungi/mold, asbestos, lead paint, lead contamination, toxic waste, formaldehyde, electromagnetic radiation, buried fuel oil tanks, ground water contamination and soil contamination. We are not trained or licensed to recognize or discuss any of these materials. We may make reference to one of more of these materials in this report when we recognize one of the common forms of these substances. If further study or analysis seems prudent, the advice and services of the appropriate specialists are advised.

Conclusion

COMMENTSThis structure appears to be of standard quality, in need of miscellaneous repair and upgrading. There is also maintenance in need of attention. Examples of these conditions have been described in this report.

If performed routinely, this type of construction requires average maintenance to keep it in serviceable condition.

Most of the items that are in need of immediate attention and/or possible major cost items that would require repair in the near future are listed in the report summary. Please refer to these items for more information.

Page 105: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

ADDENDA TO INSPECTION REPORT 1. The inspection to be performed for Client consists of non-intrusive visual observations to survey the readily accessible, easily visible material components, systems and equipment of the building. The inspection is designed to identify material physical deficiencies in the building’s components, systems and equipment, as they exist at the time of the inspection. The work product resulting from completing an inspection in accordance with this contract is an inspection report. The inspection report incorporates the information obtained during the inspection. The inspection report is for the sole use and benefit of the Client. Client agrees to read the entire inspection report when it is received and shall promptly call the Inspector with any questions or concerns Client may have regarding the inspection report or the inspection. The inspection report shall be considered the final and exclusive findings of the Inspector regarding the inspection of the building. Client shall not rely on any oral statement made by the Inspector prior to issuance of the inspection report. 2. Components and systems operated during the inspection will be identified in the inspection report. The identified components and systems shall be operated with normal user controls and as conditions permit. If a component or system is operated, it may be conducted without the aid of special protective clothing, exploratory probing, removing materials, testing, measuring, preparing, calculations or using special equipment, including meters or devices of any kind. Testing, measuring, or preparing calculations for any system or component to determine adequacy, capacity, or compliance with any standard is outside the scope of this contract. 3. The term “poor” or “major concern” in regard to a component mean the presence of conspicuous patent defects or material deferred maintenance of the building’s material systems, components, or building equipment as observed during the inspection. This definition specifically excludes deficiencies that may be remedied with routine maintenance, miscellaneous minor repairs, and normal operating maintenance, and excludes conditions that generally do not present material physical deficiencies of the building. 4. Inspector is an expert generalist and not acting as an expert in any SPECIFIC craft or

Page 106: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

trade. The inspector may make recommendations for further evaluation by an individual(s) who is an expert or specialist IN ONE OR MORE SPECIFIC BUILDING COMPONENTS OR SYSTEMS. 5. The inspection is not technically exhaustive. The cost obtaining information or the time required to conduct a technically exhaustive inspection and prepare the inspection report could outweigh the usefulness of the information and could be detrimental to the orderly and timely completion of Client’s transaction. 6. No inspection can wholly eliminate the uncertainty regarding the presence of physical deficiencies and the performance of the building’s systems. Preparation of an inspection report in accordance with this contract is intended to reduce, but not eliminate, the uncertainty regarding the potential for component or system failure and to reduce the potential that such component or system may not be initially observed. Client recognizes the inherent subjective nature of the inspector’s opinions as to issues such as workmanship, quality of original installation, and estimating the remaining useful life of any given component or system. The inspector’s opinions generally are formed without detailed knowledge from those specifically familiar with the component or system’s performance. 7. The inspection report will contain a representative indication of the property condition at the time of the inspection and is dependent on the information available to the inspector at that time. 8. It is the Client’s duty and obligation to exercise reasonable care to protect himself or herself regarding the condition of the building, including those facts that are known to or within the diligent attention and observation of the Client. SCOPE AND LIMITATIONS OF THIS INSPECTION This inspection is limited to a visual observation of the exposed and readily accessible areas of the home. The concealed and inaccessible areas are not included. The following locations are considered inaccessible due to limited height and excluded from this inspection unless otherwise stated:

Crawl space areas less than 18 inches in height

Attic spaces less than 5 feet in height

Spaces under outdoor decks less than 5 feet high Observation includes operation of the systems or components by means of the normal user controls. Dismantling of equipment, and destructive testing is not included. Some specific items are also excluded, and these are listed in the following section. If you feel there is a need for evaluation of any of these items, then you will need to arrange for specific inspections. Items not Included

Page 107: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

1. Recreational, leisure, playground or decorative equipment or appliances including but not limited to pools, hot tubs, saunas, steam baths, landscape lighting, fountains, shrubs, trees, and tennis courts; 2. Cosmetic conditions (wallpapering, painting, carpeting, scratches, scrapes, dents, cracks, stains, soiled or faded surfaces on the structure or equipment, soiled, faded, torn, or dirty floor, wall or window coverings etc.); 3. Noise pollution or air quality in the area; 4. Earthquake hazard, liquefaction, flood plain, soil, slide potential or any other geological conditions or evaluations; 5. Engineering level evaluations on any topic; 6. Existence or non-existence of solder or lead in water pipes, asbestos, hazardous waste, radon, urea formaldehyde urethane, lead paint or any other environmental, flammable or toxic contaminants or the existence of water or airborne diseases or illnesses and all other similar or potentially harmful substances (although the inspector may note the possible existence of asbestos in ceiling texture and furnace duct tape); 7. Zoning or municipal code (e.g. building, fire, housing (existing buildings), mechanical, electrical, plumbing, etc. code) restrictions or other legal requirements of any kind; 8. Any repairs which relate to some standard of interior decorating; 9. Cracked heat exchangers or similar devices in furnaces; 10. Any evaluation which requires the calculation of the capacity of any system or item that is expected to be part of the inspection. Examples include but are not limited to the calculation of appropriate wattage or wiring of kitchen appliances, appropriate sizing of flues or chimneys, appropriate ventilation to combustion-based items (e.g. furnaces, water heaters, fireplaces etc.), appropriate sizing, spacing and spanning of joists, beams, columns, girders, trusses, rafters, studs etc., appropriate sizing of plumbing and fuel lines, etc.; 11. Washers and dryers; 12. Circuit breaker operation; 13. Specialty evaluations such as private sewage, wells, solar heating systems, alarms, intercom systems, central vacuum systems, wood and coal stoves, pre-fab and zero clearance fireplaces, space heaters, sprinkler systems, gas logs, gas lights, elevators and common areas unless these have been specifically added to the inspection description above but only to the degree that the inspector is capable of evaluating these items;

Page 108: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

14. Items that are not visible and exposed including but not limited to concealed wiring, plumbing, water leaks, under bathtubs and shower stalls due to faulty pans or otherwise, vent lines, duct work, exterior foundation walls (below grade or covered by shrubs or wall/paneling, stored goods etc.) and footings, underground utilities, and systems and chimney flues; 15. Evaluations involving destructive testing; 16. Evaluation which requires moving personal goods, debris, furniture, equipment, floor covering, insulation or like materials; 17. Design problems and adequacy or operational capacity, quality or suitability; 18. Fireplace drafting; 19. To prevent damages to units, air conditioning when outside temperature below 60 degrees F or if the unit has not been warmed up or on for at least 24 hours prior to inspection; 20. Any evaluation which would involve scraping paint or other wall coverings; 21. Heating system accessories (e.g. humidifiers, electronic air cleaners etc.); 22. Legal description of property such as boundaries, egress/ingress, etc.; 23. Quality of materials; 24. Conformance with plan specifications or manufacturers specifications; 25. Flood conditions or plains; 26. Any other characteristics or items which are generally not included in a building inspection report on a regular basis. Services for inspecting or evaluating the excluded items listed above may be available from the Inspector for an additional fee or from specialists qualified to inspect or evaluate a particular category or item. Disclaimer In some cases we may recommend your consulting a specialist such as a structural engineer or licensed electrician. Hiring a specialist can be a prudent means of providing some protection of your financial investment in this property. WE DO NOT MAKE ANY TYPE OF WARRANTY OR GUARANTEE AS TO THE CONDITION OF THE PROPERTY. SOME THINGS MAY REMAIN HIDDEN OR BECOME DEFECTIVE AFTER THE INSPECTION. IT IS NOT POSSIBLE TO DETECT

Page 109: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

EVERY DEFECT WITHIN A BUILDING DURING THE COURSE OF A GENERAL INSPECTION. THIS REPORT SHOULD BE USED IN CONJUNCTION WITH, AND NOT A REPLACEMENT FOR , A PRE-CLOSING WALK-THROUGH BY THE CLIENT. THIS INSPECTION IS NOT AN INSURANCE POLICY AGAINST HIDDEN DEFECTS, OR CONDITIONS THAT ARE NOT VISIBLE AND READILY APPARENT AT THE TIME OF INSPECTION. THE COST OF THIS INSPECTION DOES NOT ENTITLE YOU TO ANY TYPE OF PROTECTION FROM HIDDEN FLAWS AND DEFECTS. THIS INSPECTION DOES NOT TRANSFER YOUR ULTIMATE RESPONSIBILITY TO ALL POINT HOME INSPECTIONS. ENVIRONMENTAL CONCERNS: Client acknowledges that what is being contracted for is a building inspection and not an environmental evaluation and the inspection is not intended to detect, identify or disclose any health or environmental concerns regarding this building or property, including, but not limited to, the presence of asbestos, radon, lead, urea formaldehyde, fungi, mold, mildew, PCB’s or other toxic materials or substances in the water, air, soil or building materials. CONFIDENTIAL REPORT: The inspection report to be prepared for the Client is solely and exclusively for the Client’s own information and may not be relied upon by any other person. Client agrees to maintain the confidentiality of the inspection report and agrees not to disclose any part of it to any other person. Client my distribute copies of the inspection report to other persons directly involved in this transaction, but the Client and Inspector do not in any way intend to benefit said other persons directly or indirectly through this Contract, the inspection or the inspection report. CLIENT AGREES TO INDEMNIFY, DEFEND AND HOLD THE INSPECTOR HARMLESS FROM ANY THRID PARTY CLAIMS ARISING OUT OF THE CLIENT’S UNAUTHORIZED DISTRIBUTION OF THE INSPECTION REPORT. LIQUIDATED DAMAGES: IT IS UNDERSTOOD AND AGREES BY AND BETWEEN THE PARTIES HERETO THAT THE INSPECTOR/INSPECTION COMPANY IS NOT AN INSURER, THAT THE PAYMENT FOR THE SUBJECT INSPECTION IS BASED SOLELY ON THE VALUE OF THE SERVICES PROVIDED BY THE INSPECTOR/INSPECTION COMPANY IN THE PREFORMANCE OF THE INSPECTION AND PRODUCTION OF THE INSPECTION REPORT AS DESCRIBED HEREIN, THATIT IS IMPRACTICABLE AND EXTREMELY DIFFICULT TO FIX THE ACTUAL DAMAGES, OF ANY, WHICH MAY RESULT FROM A FAILURE TO PERFORM SUCH SERVICES, AND IN CASE OF FAILURE TO PERFORM SUCH SERVICES AND A RESULTING LOSS, THE CLIENT’S DAMAGES HEREIN SHALL BE LIQUIDATER AND FIXED IN AN AMOUNT EQUAL TO THE INSPECTION FEE PAID MULTIPLIED BY ONE HUNDRED TWENT-FIVE PERCENT (125%) AS

Page 110: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

LIQUIDATED DAMAGES AND NOT AS A PENALTY, AND THIS REMEDY SHALL BE EXCLUSIVE. GENERAL PROVISIONS: A. This inspection contract, the inspection, and the inspection report do not constitute a warranty, guarantee, or insurance policy of any kind whatsoever. B. No legal action or proceeding of any kind, including in tort or contract can be commenced against Inspector/Inspection Company, or its officers, agents or employees more than one year after the date of the subject inspection. Time is expressly of the essence herein. THIS TIME PERIOD IS SHORTER THAN OTHERWISE PROVIDED BY LAW. C. In the event the Client discovers a material physical deficiency in a component, system or equipment of the building that was not identified and reported by the Inspector, Client shall so notify the Inspector in writing and allow Inspector and/or Inspector’s designated representative to re-inspect and document the condition(s) of the material physical deficiency prior to making any repair, alteration, or replacement to said physical deficiency. D. Should any provision of this contract be held by a court of competent jurisdiction to be either invalid or unenforceable, the remaining provisions of this contract shall remain in full force and effect, unimpaired by the court’s holding. E. This contract shall be binding upon and inure to the benefit of only the undersigned parties and their heirs, successors and assigns. F. This contract constitutes the entire integrated agreement between the parties hereto pertaining to the subject matter hereof, and may be modified only by a written agreement signed by all of the parties hereto. No oral agreements, understanding, or representations shall change, modify, or amend any part of this contract. G. Each party signing this contract warrants and represents that he/she has the full capacity and authority to execute this contract on behalf of the named party whether it is a corporation, partnership, or other entity. If this contract is executed on behalf of the Client by a third party, the person executing this contract expressly represents to the Inspector that he/she has the full and complete authority to execute this contract on the Client’s behalf and to fully and completely bind the Client to all of the terms, conditions, limitations, exceptions and exclusions of this contract. This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited. FOLLOW-UP INSPECTION POLICY Generally we discourage follow-up inspections for these reasons

Page 111: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

1. Quality of repairs

If repairs are made to a property based on the results of an inspection, the work should be performed by qualified contractors, not the seller. By qualified, we mean licensed, bonded, state-certified where applicable and with a reasonable amount of experience. Contractors providing repairs should provide legible documentation in the form of work orders and/or receipts. If repairs are made in this way, then there's generally no need for a follow-up inspection. Additionally, it may be better to negotiate a lower price on your home and have repairs made by contractors you choose rather than the seller making repairs as cheaply as possible. ________________________________________ As a part of our service, we sometimes provide approximate, cost of repair estimates for particular items. These estimates should be considered as background information only. It is beyond the scope of this inspection and report to supply you with accurate repair costs. Such estimates should be supplied by contractors who specialize in this type of work. Our estimates should be used only as guidelines. If you intend to negotiate the price of this property based on defects found during this inspection, we strongly suggest you obtain one or more written bids from a licensed contractor(s). It is a conflict of interest for Strong Foundations Home Inspection to recommend any specific contractor.

Page 112: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

Life Expectancy Charts for Homes PLEASE NOTE: These life expectancies have been determined through research and testing based on regular recommended maintenance and conditions of normal wear and tear, and not extreme weather or other conditions, neglect, over-use or abuse. Therefore, they should be used as guidelines only, and not relied upon as guarantees or warranties. Surface preparation and paint quality are the most important determinants of a paint's life expectancy. Ultraviolet (UV) rays via sunshine can shorten life expectancy. Additionally, conditions of high humidity indoors or outdoors can affect the lifespan of these components, which is why they should be inspected and maintained seasonally.

ADHESIVES, CAULK & PAINTS

YEARS

Caulking (interior & exterior) 5 to 10 Construction Glue 20+ Paint (exterior) 7 to 10 Paint (interior) 10 to 15 Roofing Adhesives/Cements 15+ Sealants 8 Stains 3 to 8 Appliance life expectancy depends to a great extent on the use it receives. Furthermore, consumers often replace appliances long before they become worn out due to changes in styling, technology and consumer preferences.

APPLIANCES YEARS Air Conditioner (window)

5 to 7

Compactor (trash) 6 Dehumidifier 8 Dishwasher 9 Disposal (food waste) 12 Dryer Vent (plastic) 5 Dryer Vent (steel) 20 Dryer (clothes) 13 Exhaust Fans 10 Freezer 10 to 20 Gas Oven 10 to 18 Hand Dryer 10 to 12 Humidifier (portable) 8 Microwave Oven 9 Range/Oven Hood 14 Electric Range 13 to 15

Page 113: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

Gas Range 15 to 17 Refrigerator 9 to 13 Swamp Cooler 5 to 15 Washing Machine 5 to 15 Whole-House Vacuum System 20 Modern kitchens today are larger and more elaborate. Together with the family room, they now form the “great room.”

CABINETRY & STORAGE YEARS Bathroom Cabinets 50+ Closet Shelves 100+ Entertainment Center/Home Office

10

Garage/Laundry Cabinets 70+ Kitchen Cabinets 50 Medicine Cabinet 25+ Modular (stock manufacturing-type)

50

Walls and ceilings last the full lifespan of the home.

CEILINGS & WALLS YEARS Acoustical Tile Ceiling 40+ (older than 25 years may

contain asbestos) Ceramic Tile 70+ Concrete 75+ Gypsum 75 Wood Paneling 20 to 50 Suspended Ceiling 25+ Natural stone countertops, which are less expensive than they were just a few years ago, are becoming more popular, and one can expect them to last a lifetime. Cultured marble countertops have a shorter life expectancy, however.

COUNTERTOPS YEARS Concrete 50 Cultured Marble 20 Natural Stone 100+ Laminate 20 to 30 Resin 10+ Tile 100+ Wood 100+

Page 114: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

Decks are exposed to a wide range of conditions in different climates, from wind and hail in some areas, to relatively consistent, dry weather in others. See FASTENERS & STEEL section for fasteners.

DECKS YEARS Deck Planks 15 Composite 8 to 25 Structural Wood 10 to 30 Exterior fiberglass, steel and wood doors will last as long as the house, while vinyl and screen doors have a shorter life expectancy. The gaskets/weatherstripping of exterior doors may have to be replaced every 5 to 8 years.

DOORS YEARS Closet (interior) 100+ Fiberglass (exterior) 100+ Fire-Rated Steel (exterior) 100+ French (interior) 30 to 50 Screen (exterior) 30 Sliding Glass/Patio (exterior) 20 (for roller wheel/track

repair/replacement) Vinyl (exterior) 20 Wood (exterior) 100+ Wood (hollow-core interior) 20 to 30 Wood (solid-core interior) 30 to 100+ Copper-plated wiring, copper-clad aluminum, and bare copper wiring are expected to last a lifetime, whereas electrical accessories and lighting controls, such as dimmer switches, may need to be replaced after 10 years. GFCIs could last 30 years, but much less if tripped regularly. Remember that faulty, damaged or overloaded electrical circuits or equipment are the leading cause of house fires, so they should be inspected regularly and repaired or updated as needed.

ELECTRICAL YEARS Accessories 10+ Arc-Fault Circuit Interrupters (AFCIs)

30

Bare Copper 100+ Bulbs (compact fluorescent) 8,000 to 10,000+ hours Bulbs (halogen) 4,000 to 8,000+ hours Bulbs (incandescent) 1,000 to 2,000+ hours Bulbs (LED) 30,000 to 50,000+ hours Copper-Clad Aluminum 100+ Copper-Plated 100+

Page 115: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

Fixtures 40 Ground-Fault Circuit Interrupters (GFCIs)

up to 30

Lighting Controls 30+ Residential Propane Backup Generators

12

Service Panel 60 Solar Panels 20 to 30 Solar System Batteries 3 to 12 Wind Turbine Generators 20 Floor and roof trusses and laminated strand lumber are durable household components, and engineered trim may last 30 years.

ENGINEERED LUMBER YEARS Engineered Joists 80+ Laminated Strand Lumber 100+ Laminated Veneer Lumber 80+ Trusses 100+ Fastener manufacturers do not give lifespans for their products because they vary too much based on where the fasteners are installed in a home, the materials in which they're installed, and the local climate and environment. However, inspectors can use the guidelines below to make educated judgments about the materials they inspect.

FASTENERS, CONNECTORS & STEEL

YEARS

Adjustable Steel Columns 50+ Fasteners (bright) 25 to 60 Fasteners (copper) 65 to 80+ Fasteners (galvanized) 10+ Fasteners (electro-galvanized) 15 to 45 Fasteners (hot-dipped galvanized)

35 to 60

Fasteners (stainless) 65 to 100+ Steel Beams 200+ Steel Columns 100+ Steel Plates 100+ Flooring life is dependent on maintenance and the amount of foot traffic the floor endures.

FLOORING YEARS All Wood Floors 100+ Bamboo 100+ Brick Pavers 100+

Page 116: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

Carpet 8 to 10 Concrete 50+ Engineered Wood 50+ Exotic Wood 100+ Granite 100+ Laminate 15 to 25 Linoleum 25 Marble 100+ Other Domestic Wood 100+ Slate 100 Terrazzo 75+ Tile 75 to 100 Vinyl 25 Concrete and poured-block footings and foundations will last a lifetime, assuming they were properly built. Waterproofing with bituminous coating lasts 10 years, but if it cracks, it is immediately damaged.

FOUNDATIONS YEARS Baseboard Waterproofing System 50 Bituminous-Coating Waterproofing

10

Concrete Block 100+ Insulated Concrete Forms (ICFs) 100 Permanent Wood Foundation (PWF; treated)

75

Post and Pier 20 to 65 Post and Tensioned Slab on Grade

100+

Poured-Concrete Footings and Foundation

100+

Slab on Grade (concrete) 100 Wood Foundation 5 to 40 Framing and structural systems have extended longevities; poured-concrete systems, timber frame houses and structural insulated panels will all last a lifetime.

FRAMING YEARS Log 80 to 200 Poured-Concrete Systems 100+ Steel 100+ Structural Insulated Panels (SIPs)

100+

Timber Frame 100+

Page 117: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

The quality and frequency of use will affect the longevity of garage doors and openers.

GARAGES YEARS Garage Doors 20 to 25 Garage Door Openers 10 to 15 Home technology systems have diverse life expectancies and may have to be upgraded due to evolution in technology.

HOME TECHNOLOGY YEARS Built-In Audio 20 Carbon Monoxide Detectors* 5 Doorbells 45 Home Automation System 5 to 50 Intercoms 20 Security System 5 to 20 Smoke/Heat Detectors* less than 10 Wireless Home Networks 5+ * Batteries should be changed at least annually. Thermostats may last 35 years but they are usually replaced before they fail due to technological improvements.

HVAC YEARS Air Conditioner (central) 7 to 15 Air Exchanger 15 Attic Fan 15 to 25 Boiler 40 Burner 10+ Ceiling Fan 5 to 10 Chimney Cap (concrete)

100+

Chimney Cap (metal) 10 to 20 Chimney Cap (mortar) 15 Chimney Flue Tile 40 to 120 Condenser 8 to 20 Dampers 20+ Dehumidifier 8 Diffusers, Grilles and Registers 25 Ducting 60 to 100 Electric Radiant Heater 40 Evaporative Cooler 15 to 25

Page 118: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

Furnace 15 to 25 Gas Fireplace 15 to 25 Heat Exchanger 10 to 15 Heat Pump 10 to 15 Heat-Recovery Ventilator 20 Hot-Water and Steam-Radiant Boiler

40

Humidifier 12 Induction and Fan-Coil Units 10 to 15 Thermostats 35 Ventilator 7 As long as they are not punctured, cut or burned and are kept dry and away from UV rays, cellulose, fiberglass and foam insulation materials will last a lifetime. This is true regardless of whether they were installed as loose-fill, housewrap or batts/rolls.

INSULATION & INFILTRATION BARRIERS

YEARS

Batts/Rolls 100+ Black Paper (felt paper) 15 to 30 Cellulose 100+ Fiberglass 100+ Foamboard 100+ Housewrap 80+ Liquid-Applied Membrane 50 Loose-Fill 100+ Rockwool 100+ Wrap Tape 80+ Masonry is one of the most enduring household components. Fireplaces, chimneys and brick veneers can last the lifetime of the home.

MASONRY & CONCRETE YEARS Brick 100+ Insulated Concrete Forms (hybrid block)

100+

Concrete Masonry Units (CMUs) 100+ Man-Made Stone 25 Masonry Sealant 2 to 20 Stone 100+ Stucco/EIFS 50+ Veneer 100+

Page 119: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

Custom millwork and stair parts will last a lifetime and are typically only upgraded for aesthetic reasons.

MOLDING, MILLWORK & TRIM

YEARS

Attic Stairs (pull-down) 50 Custom Millwork 100+ Pre-Built Stairs 100+ Stair Parts 100+ Stairs 100+ The lifetime of any wood product depends heavily on moisture intrusion.

PANELS YEARS Flooring Underlayment 25 Hardboard 40 Particleboard 60 Plywood 100 Softwood 30 Oriented Strand Board (OSB) 60 Wall Panels 100+ The quality of plumbing fixtures varies dramatically. The mineral content of water can shorten the life expectancy of water heaters and clog showerheads. Also, some finishes may require special maintenance with approved cleaning agents per the manufacturers in order to last their expected service lives.

PLUMBING, FIXTURES & FAUCETS

YEARS

ABS and PVC Waste Pipe 50 to 80 Accessible/ADA Handles 100+ Acrylic Kitchen Sink 50 Cast-Iron Bathtub 100 Cast-Iron Waste Pipe (above ground)

60

Cast-Iron Waste Pipe (below ground)

50 to 60

Concrete Waste Pipe 100+ Copper Water Lines 70 Enameled Steel Kitchen Sink 5 to 10+ Faucets and Spray Hose 15 to 20 Fiberglass Bathtub and Shower 20 Gas Lines (black steel) 75 Gas Lines (flex) 30

Page 120: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

Hose Bibs 20 to 30 Instant (on-demand) Water Heater

10

PEX 40 Plastic Water Lines 75 Saunas/Steam Room 15 to 20 Sewer Grinder Pump 10 Shower Enclosure/Module 50 Shower Doors 20 Showerheads 100+ (if not clogged by

mineral/other deposits) Soapstone Kitchen Sink 100+ Sump Pump 7 Toilet Tank Components 5 Toilets, Bidets and Urinals 100+ Vent Fan (ceiling) 5 to 10 Vessel Sink (stone, glass, porcelain, copper)

5 to 20+

Water Heater (conventional) 6 to 12 Water Line (copper) 50 Water Line (plastic) 50 Water Softener 20 Well Pump 15 Whirlpool Tub 20 to 50 Radon systems have but one moving part: the radon fan.

RADON SYSTEMS YEARS Air Exchanger 15 Barometric Backdraft Damper/Fresh-Air Intake

20

Caulking 5 to 10 Labeling 25 Manometer 15 Piping 50+ Radon Fan 5 to 8 The life of a roof depends on local weather conditions, building and design, material quality, and adequate maintenance. Hot climates drastically reduce asphalt shingle life. Roofs in areas that experience severe weather, such as hail, tornadoes and/or hurricanes, may also experience a shorter-than-normal lifespan overall or may incur isolated damage that requires repair in order to ensure the service life of the surrounding roofing materials.

ROOFING YEARS

Page 121: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

Aluminum Coating 3 to 7 Asphalt (architectural) 30 Asphalt Shingles (3-tab) 20 BUR (built-up roofing) 30 Clay/Concrete 100+ Coal and Tar 30 Copper 70+ EPDM (ethylene propylene diene monomer) Rubber

15 to 25

Fiber Cement 25 Green (vegetation-covered) 5 to 40 Metal 40 to 80 Modified Bitumen 20 Simulated Slate 10 to 35 Slate 60 to 150 TPO 7 to 20 Wood 25 Outside siding materials typically last a lifetime. Some exterior components may require protection through appropriate paints or sealants, as well as regular maintenance. Also, while well-maintained and undamaged flashing can last a long time, it is their connections that tend to fail, so seasonal inspection and maintenance are strongly recommended.

SIDINGS, FLASHING & ACCESSORIES

YEARS

Aluminum Gutters, Downspouts, Soffit and Fascia

20 to 40+

Aluminum Siding 25 to 40+ Asbestos Shingle 100 Brick 100+ Cementitious 100+ Copper Downspouts 100 Copper Gutters 50+ Engineered Wood 100+ Fiber Cement 100+ Galvanized Steel Gutters/Downspouts

20

Manufactured Stone 100+ Stone 100+ Stucco/EIFS 50+ Trim 25 Vinyl Gutters and Downspouts 25+ Vinyl Siding 60 Wood/Exterior Shutters 20

Page 122: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

Site and landscaping elements have life expectancies that vary dramatically.

SITE & LANDSCAPING YEARS American Red Clay 100+ Asphalt Driveway 15 to 20 Brick and Concrete Patio 15 to 25 Clay Paving 100+ Concrete Walks 40 to 50 Controllers 15 Gravel Walks 4 to 6 Mulch 1 to 2 Polyvinyl Fencing 100+ Sprinkler Heads 10 to 14 Underground PVC Piping 60+ Valves 20 Wood Chips 1 to 5 Wood Fencing 20 Swimming pools are composed of many systems and components, all with varying life expectancies.

SWIMMING POOLS YEARS Concrete Shell 25+ Cover 7 Diving Board 10 Filter and Pump 10 Interior Finish 10 to 35 Pool Water Heater 8 Vinyl Liner 10 Waterline Tile 15+ Aluminum windows are expected to last between 15 and 20 years, while wooden windows should last nearly 30 years.

WINDOWS YEARS Aluminum/Aluminum-Clad 15 to 20 Double-Pane 8 to 20 Skylights 10 to 20 Vinyl/Fiberglass Windows 20 to 40 Window Glazing 10+ Wood 30+ Note: Life expectancy varies with usage, weather, installation, maintenance and quality of

Page 123: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

materials. This list should be used only as a general guideline and not as a guarantee or warranty regarding the performance or life expectancy of any appliance, product, system or component. Evaluations are made as to the present age, and remaining economic life of an item, i.e. water heaters, roofs, plumbing, furnaces, etc. These evaluations are based on visual observation, industry averages and prior experience. THEY ARE NOT OFFERED AS A WARRANTY OR CERTIFICATION OF REMAINING LIFE.

Page 124: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

HOME MAINTENANCE CHECK LIST: Monthly: 1. Clean any removable dishwasher filters. 2. Purge food disposal by filling the kitchen sink with clean water, then turn on the device until the water drains through. 3. Wash refrigerator/freezer interior walls and door gaskets with a solution of one quart of warm water to two tablespoons of baking soda and wipe dry. 4. Vacuum and clean “return” air ducts/grills. 5. Inspect lighting fixtures and replace any burned-out bulbs. 6. Clean clothes dryer lint trap and/or duct for better energy efficiency and to decrease the risk of fire. Quarterly: 1. Inspect and service doors by cleaning and lubricating latches, hinges or replacing weather-stripping as might be required. 2. Inspect and repair, if necessary, exterior caulking and finish around windows, doors, and siding. 3. Replace/clean, at least quarterly, furnace, heating and cooling system filters. 4. Re-tighten knobs and pulls on cabinets. Clean and lubricate drawer tracks and guides. Semi-annually: 1. Inspect and test smoke and carbon monoxide alarms. Replace backup batteries as might be required. 2. Test (GFCI) ground fault circuit interrupters and (AFCI) arc fault breakers. 3. Inspect and maintain/clean gutters and downspouts. Runoff water must be directed away from the home. 4. Inspect attics and substructure areas for rodent droppings or other signs of pests or leaks/standing water, etc. 5. Prior to the beginning of the rainy season, test sump pumps for adequacy and function. 6. Look for moisture or decay, outside and inside the house, where flat surface decks and landing attach to the house. This is especially important if the landings do not have proper flashings. 7. Clean range hood fan grills and housings. 8. Use a vacuum cleaner to remove dust on coils behind the refrigerator/freezer. Annually: 1. Licensed contractor to inspect and service heating and air-conditioning systems. 2. Professional contractor to inspect and service wood burning appliances and chimneys. 3. Seal any foundation cracks. 4. Inspect, clean and lubricate garage vehicle door tracks and test auto-reverse functions. 5. Clean and lubricate sliding glass door and window tracks. 6. Inspect exterior paint for cracking and wear. Repaint, caulk and seal as needed.

Page 125: FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE ......608 State St. South Kirkland, WA 98033 hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 9927 171st Ave SE, Renton, WA 98059Confidential

©2018 Strong Foundations Home Inspection

7. Reseal, as required, wood decks and landings. 8. Inspect, for water damage, pests or rot, any substructure and attic areas. 9. Inspect roof flashings, chimney caps, shingles. 10. Inspect outside electrical service lines for damage, exposed wires or proximity to tree limbs. 11. Inspect all supply hoses at sinks, toilets and washing machines. 12. Clean and repair caulking or grout in bathrooms or kitchens. 13. Clean bathroom exhaust fan blades and grills. 14. Inspect all electric coeds and replace as needed. 15. Change water filters and have fresh water systems professionally services. Tips for keeping drains clear: 1. Pour a pot of hot water down the drain once a week to help clear away fat or grease that may have built-up in the drain line or the P-trap. 2. If a drain is clogged, try pouring 1/2 cup of white vinegar down the drain. Cover the drain and let the mixture sit for a few minutes. Then pour a pot of hot water down the drain. General Safety tips: Ensure that you know where the following items are located: 1. Emergency contact telephone numbers. 2. Fire extinguishers and water hose pipes. 3. Heating gas/fuel main shut off valve. 4. Main electrical disconnect circuit breaker (breaker box/service panel). 5. Main drain line clean-out. 6. Main water shut-off valve. 7. All window and door exits.