  • SUPPLY FAN AND VENT SCHEDULE

    EXHAUST FAN SCHEDULE

    AIR HANDLING UNIT SCHEDULE

    PUMP SCHEDULE

    SOUND ATTENUATOR SCHEDULE

    BOILER SCHEDULE

    GENERAL MECHANICAL NOTES

    FAN POWERED TERMINAL UNIT SCHEDULE AIR DEVICE SCHEDULE

    DH

    DEHUMIDIFIER DETAIL2

    CVT

    4 MECHANICAL SYSTEM INSTALLATION ORDER

    MECHANICAL SYMBOL SCHEDULE

    OUTSIDE AIR CALCULATIONS

    KITCHEN FAN SCHEDULE

    AIR TERMINAL UNIT DETAIL

    CVT

    1

    MOTOR STARTER REQUIREMENTS

    AIR COOLED ROTARY CHILLER

    1001 Fannin Street, Suite 300 | Houston, TX 77002 USAPhone 713.622.1180 | Fax 713.622.7021

    www.morris-hz.com

    M4

    MECHANICAL SCHEDULES AND DETAILS

    VAV TERMINAL UNIT SCHEDULE

    IDF A/C UNITS (ACU)

    AIR VALVE UNIT SCHEDULE

  • 1 DUCTWORK DETAILS

    RESIDENTIAL CLOTHES DRYER VENT8

    CEILING AIR DEVICE DETAIL2

    3 DUCT FIRE DAMPER DETAIL

    SOUNDATTENUATOR

    4 SOUND ATTENUATOR FIRE DAMPER DETAIL

    KSF

    KEF

    11 KITCHEN FAN DETAIL

    21 DUCT TAP CONNECTION DETAIL

    BOILER

    CONDENSATE DRAIN DETAILMULTIPLE PIPE HANGER DETAIL17

    SINGLE PIPE HANGER DETAIL18 13COIL PIPING DETAIL

    CHEMICAL POT FEEDER/FILTER15

    WALL PENETRATION DETAIL

    16

    12

    IPS STAINLESS STEEL FLUE VENT10END SUCTION PUMP DETAIL14OUTDOOR PIPING SUPPORT DETAIL19

    EXPANSION TANK DETAIL20

    RAHU ROOF CURB DETAIL9

    RAHU HOUSING

    SIDE VIEWFRONT VIEW

    MECHANICAL - ELECTRICAL COORDINATION DETAIL22

    ROOF FAN AND VENT DETAIL7

    6 CVT HANGER DETAIL

    1001 Fannin Street, Suite 300 | Houston, TX 77002 USAPhone 713.622.1180 | Fax 713.622.7021

    www.morris-hz.com

    M5

    MECHANICAL DETAILS

  • SF

    EF

    VAV/CVT

    VAV SYSTEM CONTROLS SCHEMATIC5

    AHU

    VAV/CVT

    BAS

    BAS

    4SINGLE ZONE FACE-AND-BYPASS AHU CONTROL SCHEMATIC

    EF

    SF

    CHILLED WATER SYSTEM PIPING AND CONTROLS SCHEMATIC1

    PRE-TREATED OUTSIDE AIR FACE-AND-BYPASS AHU CONTROL SCHEMATIC

    3

    BAS

    EMS

    PUMP HWP

    2 HOT WATER SYSTEM PIPING & CONTROLS SCHEMATIC

    CHILLER CH-2 CHILLER CH-1

    EMS

    PUMP CHP-2PUMP CHP-1PUMP SP

    BOILER BR-1 BOILER BR-2

    1001 Fannin Street, Suite 300 | Houston, TX 77002 USAPhone 713.622.1180 | Fax 713.622.7021

    www.morris-hz.com

    M6

    & CONTROLS SCHEMATICS

    MECHANICAL PIPING

  • 4

    AHU-2

    H

    1

    SF-2

    ACU-2B

    ACU-2A

    2

    SF-1AHU-1

    M

    4

    ACU-1B

    ACU-1A

    AV-1

    6

    AHU-3

    AHU-4

    EF-3

    G

    7

    8

    H

    SF-3

    SF-4

    10

    SF-5

    AHU-7

    AHU-8

    EF-5

    G

    13

    14

    H

    SF-6

    SA-A

    AHU-5

    AHU-6

    M

    10.2

    8

    L

    OV-1

    OV-2

    MECHANICAL ROOM 131 SECTION

    MECHANICAL ROOM 149 SECTION6

    4

    MECHANICAL ROOM 167 SECTION8

    2

    4

    MECHANICAL ROOM 119 SECTION

    AHU-1

    SF-1

    MECHANICAL ROOM 189 SECTION10

    MECHANICAL ROOM 119 DETAIL PLAN1

    MECHANICAL ROOM 131 DETAIL PLAN3

    MECHANICAL ROOM 149 DETAIL PLAN5

    MECHANICAL ROOM 167 DETAIL PLAN7MECHANICAL ROOM 189 DETAIL PLAN9

    AHU-6

    109

    AHU-5

    OV-1 OV-2

    AHU-3 AHU-4

    7

    SF-4

    8

    SF-3

    AHU-8

    13

    AHU-7

    14SF-6SF-5

    AHU-2

    H

    ACU-1B

    ACU-1A

    ROOF PIPE JACK DETAIL12

    1001 Fannin Street, Suite 300 | Houston, TX 77002 USAPhone 713.622.1180 | Fax 713.622.7021

    www.morris-hz.com

    M7PLANS & SECTIONS

    MECHANICAL DETAIL

    ACU-A

    ACU-B

    11REFRIGERANT PIPING SCHEMATIC FOR ACU

  • 54

    OV-4

    AHU-10

    JL

    18.4

    20

    CH-2

    CHP-2

    CHP-1

    GWH

    CH-1

    HWP

    AHU-11

    OV-3

    BR-1BR-2

    SP

    GM

    3

    AHU-9

    SF-7

    18

    19

    H

    ACU-4BACU-4A

    MECHANICAL CENTRAL PLANT DETAIL PLAN1MECHANICAL ROOM 208 DETAIL PLAN2MECHANICAL ROOM 208 SECTIONAHU-9

    4

    CH-1

    MECHANICAL CENTRAL PLANT SECTION

    20

    BR-1 HWP

    3

    H

    18

    AHU-10

    SF-7

    MECHANICAL CENTRAL PLANT SECTION5

    OV-3

    AHU-11 CHP-2CHP-1

    GWH

    CH-2

    18 20OV-4

    1001 Fannin Street, Suite 300 | Houston, TX 77002 USAPhone 713.622.1180 | Fax 713.622.7021

    www.morris-hz.com

    M8

    PLANS & SECTIONS

    MECHANICAL DETAIL