filter combiners - sdp telecom a molex company · pdf filefilter combiners capability catalog...

20
Engineered To Outperform Filter Combiners Capability Catalog Market-Driven Innovative Customer-Focused Market-Driven Innovative Customer-Focused

Upload: doankhue

Post on 18-Mar-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

Engineered To Outperform

Filter CombinersCapability Catalog

Market-Driven ■ Innovative ■ Customer-FocusedMarket-Driven ■ Innovative ■ Customer-Focused

Page 2: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

Filter Combiners- sdptelecom.com2

This brochure has been prepared to share our capabilities, all specifications within this document are typical.For your custom specification we encourage you to inquire with our sales representatives.

[email protected]

Page 3: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

3Filter Combiners- sdptelecom.com

Table of ContentsIntroduction 4Dual-Band 5

380-960 / 1710-2700 MHz 5COM-2A4E5-XYZ-000

1710-1880 / 1920-2170 MHz 6COM-2E1G1-XYZ-000

1710-2170 / 2300-2690 MHz 7COM-2E2H2-XYZ-000

698-806/ & 710-1755 & 2110-2155 / 824-894 & 1850-2000 MHz 8COM-2B2C2-XYZ-000

Triple-Band 9698-960 / 1710-1880 / 1920-2170 MHz 9

COM-3B3E1G1-XYZ-000

698-960 / 1710-2170 / 2500-2690 MHz 10COM-3C1G1I1-XYZ-000

1710-1880 / 1920-2170 / 2500-2690 MHz 11COM-3E1G1I1-XYZ-000

824-894 / 1850-1990 / 1710-1755 & 2110-2155 MHz 12COM-3C1J1F1-XYZ-000

Quad-Band 13806-960 / 1710-1880 / 1920-2170 / 2500-2690 MHz 13

COM-4C2E2G2I2-XYZ-000

698-806 / 824-894 / 1850-1990 / 1710-1780 & 2110-2360 MHz 14COM-4B1C1F1J2-XYZ-000

698-806 / 824-894 / 1710-1880 / 1920-2170 MHz 15COM-4B2C2E2J1-XYZ-000

Penta-Band 16698-790 / 806-897 / 1850-1995 / 1710-1755 & 2110-2155 / 2300-2690 MHz 16

COM-5B1C1F1J1H2-XYZ-000

824-894 / 1850-1995 / 1710-1755 & 2110-2155 / 2300-2400 / 2500-2690 MHz 17COM-5C1F1J1H1I1-XYZ-000

Part Number Definition - XYZ 18Dual-Band Combiner 18

Triple-Band Combiner 18

Quad-Band Combiner 18

Penta-Band Combiner 18

Page 4: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

Filter Combiners- sdptelecom.com4

IntroductionSDP Filter Combiners are designed for co-siting purposes which enable sharing the same feeder cable for two, three, four, five or more frequency bands. The units can be used as a combiner near the BTS or as a splitter near the antenna. The Filter Combiner is supplied as a single unit or double unit for XPol antennas. Each unit is equipped with built-in lightning protection and DC bypass. The units are designed to sustain the highest environmental and reliability requirements and can be used in both indoor and outdoor applications.

-

X-PO

L A

NTE

NN

ALT

E 2

600

UM

TS 2

100

D

CS

180

0SDP

FDD DTMADual-Inline

UMTS 2100

BTS 1DCS 1800

BTS 2UMTS 2100

TX/RX

BTS 3LTE 2600

TX/RX(Diversity)

-

SDP

BIA

S-T

(690

2700

MH

z)

T

)

SDP

SMA

RT

BIA

S-T

(690

-270

0 M

Hz)

LTE

SDPTRI-BAND COMBINER

( 2600, UMTS 2100, DCS 1800)

Port 1 Port 2 Port 3

Port 4

RE

T

Feeder Cable

TX/RX TX/RX(Diversity)

TX/RX TX/RX(Diversity)

TX/RX TX/RX(Diversity)

X-PO

L A

NTE

NN

A

X-PO

L A

NTE

NN

ASDP

FDD DTMADual-Inline

LTE 2600

SDPFDD DTMA

Dual-Inline

DCS 1800

RE

T

Feeder Cable

SDPTRI-BAND COMBINER

(LTE 2600, UMTS 2100, DCS 1800)

Port 1 Port 2 Port 3

Port 4

SDP

DC

STO

P(6

90-2

700

MH

z)

SDP

DC

STO

P(6

90-2

700

MH

z)

SDP

DC

STO

P(6

90-2

700

MH

z)

SDP

SMA

RT

BIA

S-T

(690

-270

0 M

Hz)

TX/RX(Diversity)

TX/RX(Diversity)

TX/RX TX/RX

SDP

TRI-BAND COMBINER(LTE 2600, UMTS 2100 , DCS 1800 )

Port 1 Port 2 Port 3

Port 4

SDP

TRI-BAND COMBINER(LTE 2600, UMTS 2100 , DCS 1800 )

Port 1 Port 2 Port 3

Port 4

Page 5: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

5Filter Combiners- sdptelecom.com

Part number COM-2A4E5-XYZ-000Specification Band1 Band2Frequency band 380-960 MHz 1710-2700 MHzInsertion loss 0.3 dB max.. 0.4 dB max.Return loss 18 dB MinRejection 50 dB Min @ Band2 50 dB Min @ Band1

Power 250 W (DIN and 4.1/9.5 Mini-DIN connector) 100 W avg input max. (N connector)

Intermodulation, 2 x 43 dBm -160 dBc typ., -155 dBc max. (DIN or Mini-DIN connector) -155 dBc typ., -150 dBc max. (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40 °C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Low Band

COMMON

High Band Low Band

COMMON

High Band

Low Band

COMMON

High BandLow Band

COMMON

High Band

COM-2A4E5-X1Z-000 COM-2A4E5-X2Z-000

COM-2A4E5-XNZ-000COM-2A4E5-XAZ-000

Block Diagram

Dual-Band380-960 / 1710-2700 MHz

Low PIM < -160 dBc Typical Product Specification

Single unit, see back page for part number definition; XYZ

Page 6: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

Filter Combiners- sdptelecom.com6

Part number COM-2E1G1-XYZ-000Specification Band1 Band2Frequency band 1710-1880 MHz 1920-2170 MHzInsertion loss 0.3 dB max.Return loss 18 dB MinRejection 50 dB Min @ Band2 50 dB Min @ Band1

Power 250 W (DIN and 4.1/9.5 Mini-DIN connector) 100 W avg input max. (N connector)

Intermodulation, 2 x 43 dBm <-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40 °C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Low Band

COMMON

High Band Low Band

COMMON

High Band

Low Band

COMMON

High BandLow Band

COMMON

High Band

COM-2E1G1-X1Z-000 COM-2E1G1-X2Z-000

COM-2E1G1-XAZ-000 COM-2E1G1-XNZ-000

Block Diagram

Dual-Band1710-1880 / 1920-2170 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 7: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

7Filter Combiners- sdptelecom.com

Part number COM-2E2H2-XYZ-000Specification Band1 Band2Frequency band 1710-2170 MHz 2300-2690 MHzInsertion loss 0.3 dB max.Return loss 18 dB MinRejection 50 dB Min @ Band2 50 dB Min @ Band1

Power 250 W (DIN and 4.1/9.5 Mini-DIN connector) 100 W avg input max. (N connector)

Intermodulation, 2 x 43 dBm <-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Low Band

COMMON

High Band Low Band

COMMON

High Band

Low Band

COMMON

High BandLow Band

COMMON

High Band

COM-2E2H2-X1Z-000 COM-2E2H2-X2Z-000

COM-2E2H2-XAZ-000 COM-2E2H2-XNZ-000

Block Diagram

Dual-Band1710-2170 / 2300-2690 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 8: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

Filter Combiners- sdptelecom.com8

Part number COM-2B2C2-XYZ-000Specification Band1 Band2Frequency band 698-806/1710-1755/2110-2155 MHz 824-894/1850-2000 MHzInsertion loss 0.5 dB max.Return loss 18 dB MinRejection 50 dB Min @ Band2 50 dB Min @ Band1Power 100 W avg input max.

Intermodulation, 2 x 43 dBm <-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Low Band

COMMON

High Band Low Band

COMMON

High Band

Low Band

COMMON

High BandLow Band

COMMON

High Band

COM-2B2C2-X1Z-000 COM-2B2C2-X2Z-000

COM-2B2C2-XAZ-000 COM-2B2C2-XNZ-000

Block Diagram

Dual-Band698-806/ & 710-1755 & 2110-2155 / 824-894 & 1850-2000 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 9: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

9Filter Combiners- sdptelecom.com

Part number COM-3B3E1G1-XYZ-000Specification Band1 Band2 Band3Frequency band 698-960 MHz 1710-1880 MHz 1920-2170 MHzInsertion loss 0.3 dB max.Return loss 18 dB MinRejection 50 dB Min @ Band2/Band3 50 dB Min @ Band1/Band3 50 dB Min @ Band1/Band2

Power 250 W (DIN and 4.1/9.5 Mini-DIN connector) 100 W avg input max. (N connector)

Intermodulation, 2 x 43 dBm

<-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Low Band Mid Band

COMMON

High Band Low Band Mid Band

COMMON

High Band

Low Band Mid Band

COMMON

High Band

Low Band Mid Band

COMMON

High BandLow Band Mid Band

COMMON

High Band

COM-3B3E1G1-X1Z-000 COM-3B3E1G1-X2Z-000

COM-3B3E1G1-X3Z-000

COM-3B3E1G1-XAZ-000 COM-3B3E1G1-XNZ-000

Block Diagram

Triple-Band698-960 / 1710-1880 / 1920-2170 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 10: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

Filter Combiners- sdptelecom.com10

Part number COM-3C1G1I1-XYZ-000Specification Band1 Band2 Band3Frequency band 698-960 MHz 1710-2170 MHz 2500-2690 MHzInsertion loss 0.3 dB max.Return loss 18 dB MinRejection 50 dB Min @ Band2/Band3 50 dB Min @ Band1/Band3 50 dB Min @ Band1/Band2

Power 250 W (DIN and 4.1/9.5 Mini-DIN connector) 100 W avg input max. (N connector)

Intermodulation, 2 x 43 dBm

<-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Low Band Mid Band

COMMON

High Band Low Band Mid Band

COMMON

High Band

Low Band Mid Band

COMMON

High Band

Low Band Mid Band

COMMON

High BandLow Band Mid Band

COMMON

High Band

COM-3C1G1I1-X1Z-000 COM-3C1G1I1-X2Z-000

COM-3C1G1I1-X3Z-000

COM-3C1G1I1-XAZ-000 COM-3C1G1I1-XNZ-000

Block Diagram

Triple-Band698-960 / 1710-2170 / 2500-2690 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 11: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

11Filter Combiners- sdptelecom.com

Part number COM-3E1G1I1-XYZ-000Specification Band1 Band2 Band3Frequency band 1710-1880 MHz 1920-2170 MHz 2500-2690 MHzInsertion loss 0.3 dB max.Return loss 18 dB MinRejection 50 dB Min @ Band2/Band3 50 dB Min @ Band1/Band3 50 dB Min @ Band1/Band2

Power 250 W (DIN and 4.1/9.5 Mini-DIN connector) 100 W avg input max. (N connector)

Intermodulation, 2 x 43 dBm

<-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Low Band Mid Band

COMMON

High Band Low Band Mid Band

COMMON

High Band

Low Band Mid Band

COMMON

High Band

Low Band Mid Band

COMMON

High BandLow Band Mid Band

COMMON

High Band

COM-3E1G1I1-X1Z-000 COM-3E1G1I1-X2Z-000

COM-3E1G1I1-X3Z-000

COM-3E1G1I1-XAZ-000 COM-3E1G1I1-XNZ-000

Block Diagram

Triple-Band1710-1880 / 1920-2170 / 2500-2690 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 12: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

Filter Combiners- sdptelecom.com12

Low Band Mid Band

COMMON

High Band Low Band Mid Band

COMMON

High Band

Low Band Mid Band

COMMON

High Band

Low Band Mid Band

COMMON

High BandLow Band Mid Band

COMMON

High Band

COM-3C1J1F1-X1Z-000 COM-3C1J1F1-X2Z-000

COM-3C1J1F1-X3Z-000

COM-3C1J1F1-XAZ-000 COM-3C1J1F1-XNZ-000

Part number COM-3C1J1F1-XYZ-000Specification Band1 Band2 Band3Frequency band 824-894 MHz 1850-1990 MHz 1710-1755/2110-2155 MHzInsertion loss 0.3 dB max. 0.5 dB max.Return loss 18 dB MinRejection 50 dB Min @ Band2/Band3 50 dB Min @ Band1/Band3 50 dB Min @ Band1/Band2

Power 250 W (DIN and 4.1/9.5 Mini-DIN connector) 100 W avg input max. (N connector)

Intermodulation, 2 x 43 dBm

<-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Block Diagram

Triple-Band824-894 / 1850-1990 / 1710-1755 & 2110-2155 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 13: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

13Filter Combiners- sdptelecom.com

Part number COM-4C2E2G2I2-XYZ-000Specification Band1 Band2 Band3 Band4Frequency band 806-960 MHz 1710-1880 MHz 1920-2170 MHz 2500-2690 MHzInsertion loss 0.5 dB max.Return loss 18 dB Min

Rejection 50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

Power 250 W (DIN and 4.1/9.5 Mini-DIN connector) 100 W avg input max. (N connector)

Intermodulation, 2 x 43 dBm

<-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Port 1 Port 2

COMMON

Port 3 Port 4 Port 1 Port 2

COMMON

Port 3 Port 4

Port 1 Port 2

COMMON

Port 3 Port 4 Port 1 Port 2

COMMON

Port 3 Port 4

Port 1 Port 2

COMMON

Port 3 Port 4Port 1 Port 2

COMMON

Port 3 Port 4

Block DiagramCOM-4C2E2G2I2-X1Z-000 COM-4C2E2G2I2-X2Z-000

COM-4C2E2G2I2-X3Z-000 COM-4C2E2G2I2-X4Z-000

COM-4C2E2G2I2-XAZ-000 COM-4C2E2G2I2-XNZ-000

Quad-Band806-960 / 1710-1880 / 1920-2170 / 2500-2690 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 14: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

Filter Combiners- sdptelecom.com14

Part number COM-4B1C1F1J2-XYZ-000Specification Band1 Band2 Band3 Band4

Frequency band 698-806 MHz 824-894 MHz 1850-1990 MHz 1710-1780/2110-2360 MHz

Insertion loss 0.5 dB max.Return loss 18 dB Min

Rejection 50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

Power 250 W (DIN and 4.1/9.5 Mini-DIN connector) 100 W avg input max. (N connector)

Intermodulation, 2 x 43 dBm

<-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Port 1 Port 2

COMMON

Port 3 Port 4 Port 1 Port 2

COMMON

Port 3 Port 4

Port 1 Port 2

COMMON

Port 3 Port 4 Port 1 Port 2

COMMON

Port 3 Port 4

Port 1 Port 2

COMMON

Port 3 Port 4Port 1 Port 2

COMMON

Port 3 Port 4

Block DiagramCOM-4B1C1F1J2-X1Z-000 COM-4B1C1F1J2-X2Z-000

COM-4B1C1F1J2-X3Z-000 COM-4B1C1F1J2-X4Z-000

COM-4B1C1F1J2-XAZ-000 COM-4B1C1F1J2-XNZ-000

Quad-Band698-806 / 824-894 / 1850-1990 / 1710-1780 & 2110-2360 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 15: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

15Filter Combiners- sdptelecom.com

Part number COM-4B2C2E2J1-XYZ-000Specification Band1 Band2 Band3 Band4Frequency band 698-806 MHz 824-894 MHz 1710-1880 MHz 1920-2170 MHzInsertion loss 0.5 dB max.Return loss 18 dB Min

Rejection 50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

Power 250 W (DIN and 4.1/9.5 Mini-DIN connector) 100 W avg input max. (N connector)

Intermodulation, 2 x 43 dBm

<-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)

ElectricalDC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°CIngress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Block Diagram

Port 1 Port 2

COMMON

Port 3 Port 4 Port 1 Port 2

COMMON

Port 3 Port 4

Port 1 Port 2

COMMON

Port 3 Port 4 Port 1 Port 2

COMMON

Port 3 Port 4

Port 1 Port 2

COMMON

Port 3 Port 4Port 1 Port 2

COMMON

Port 3 Port 4

COM-4B2C2E2J1-X1Z-000 COM-4B2C2E2J1-X2Z-000

COM-4B2C2E2J1-X3Z-000 COM-4B2C2E2J1-X4Z-000

COM-4B2C2E2J1-XAZ-000 COM-4B2C2E2J1-XNZ-000

Quad-Band698-806 / 824-894 / 1710-1880 / 1920-2170 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 16: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

Filter Combiners- sdptelecom.com16

Part number COM-5B1C1F1J1H2-XYZ-000Specification Band1 Band2 Band3 Band4 Band5

Frequency band 698-790 MHz 806-897 MHz 1850-1995 MHz 1710-1755/2110-2155 MHz 2300-2690 MHz

Insertion loss 0.5 dB max.Return loss 18 dB Min

Rejection 50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

Power 100 W avg input max.Intermodulation, 2 x 43 dBm

<-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)Electrical

DC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°C

Ingress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Block Diagram

Port 1 Port 2

COMMON

Port 3 Port 4 Port 1 Port 2

COMMON

Port 3 Port 4

Port 1 Port 2

COMMON

Port 3 Port 4 Port 1 Port 2

COMMON

Port 3 Port 4

Port 1 Port 2

COMMON

Port 3 Port 4Port 1 Port 2

COMMON

Port 3 Port 4

Port 5

Port 5

Port 5

Port 5

Port 5

Port 5Port 1 Port 2

COMMON

Port 3 Port 4 Port 5

COM-5B1C1F1J1H2-X1Z-000 COM-5B1C1F1J1H2-X2Z-000

COM-5B1C1F1J1H2-X3Z-000 COM-5B1C1F1J1H2-X4Z-000

COM-5B1C1F1J1H2-X5Z-000 COM-5B1C1F1J1H2-XAZ-000 COM-5B1C1F1J1H2-XNZ-000

Penta-Band698-790 / 806-897 / 1850-1995 / 1710-1755 & 2110-2155 / 2300-2690 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 17: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

17Filter Combiners- sdptelecom.com

Part number COM-5C1F1J1H1I1-XYZ-000Specification Band1 Band2 Band3 Band4 Band5

Frequency band 824-894 MHz 1850-1995 MHz 1710-1755/2110-2155 MHz 2300-2400 MHz 2500-2690 MHz

Insertion loss 0.5 dB max.Return loss 18 dB Min

Rejection 50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

50 dB Min @ other bands

Power 100 W avg input max.Intermodulation, 2 x 43 dBm

<-160 dBc typical (DIN conntector) <-155 dBc typical (N connector)Electrical

DC bypass 3AAISG pass yesLightning protection 3kA 10/350 us

EnvironmentalOperating temperature -40°C to 65°C

Ingress protection IP67Storage ETS 300 019-1-1

MechanicalConnectors 7/16 DIN, 4.1/9.5 Mini-DIN or N typeMounting bracket

Block Diagram

Port 1 Port 2

COMMON

Port 3 Port 4 Port 1 Port 2

COMMON

Port 3 Port 4

Port 1 Port 2

COMMON

Port 3 Port 4 Port 1 Port 2

COMMON

Port 3 Port 4

Port 1 Port 2

COMMON

Port 3 Port 4Port 1 Port 2

COMMON

Port 3 Port 4

Port 5

Port 5

Port 5

Port 5

Port 5

Port 5Port 1 Port 2

COMMON

Port 3 Port 4 Port 5

COM-5C1F1J1H1I1-X1Z-000 COM-5C1F1J1H1I1-X2Z-000

COM-5C1F1J1H1I1-X3Z-000 COM-5C1F1J1H1I1-X4Z-000

COM-5C1F1J1H1I1-X5Z-000 COM-5C1F1J1H1I1-XAZ-000 COM-5C1F1J1H1I1-XNZ-000

Penta-Band824-894 / 1850-1995 / 1710-1755 & 2110-2155 / 2300-2400 / 2500-2690 MHz

Typical Product SpecificationLow PIM < -160 dBc

Single unit, see back page for part number definition; XYZ

Page 18: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

Part Number Definition - XYZ

Dual-Band Combiner

X = single or double and indoor or outdoor application (indoor is IP65 and outdoor is IP67)0 = single indoor unit1 = single outdoor unit2 = double indoor unit3 = double outdoor unit

Y = DC Bypass for Dual band0 = bypass between port 1 and 21 = bypass between port 1 and Ant2 = bypass between port 2 and AntA = bypass through all portsN = bypass through none of the ports

Z = Connector type1 = N Female2 = DIN Female3 = Mini DIN Female

Triple-Band Combiner

X = single or double and indoor or outdoor application (indoor is IP65 and outdoor is IP67)0 = single indoor unit1 = single outdoor unit2 = double indoor unit3 = double outdoor unit

Y = DC Bypass for Triple band0 = bypass between port 1 and 31 = bypass between port 1 and Ant2 = bypass between port 2 and Ant3 = bypass between port 3 and AntA = bypass through all portsN = bypass through none of the ports

Z = Connector type1 = N Female2 = DIN Female3 = Mini DIN Female

Quad-Band Combiner

X = single or double and indoor or outdoor application (indoor is IP65 and outdoor is IP67)0 = single indoor unit1 = single outdoor unit2 = double indoor unit3 = double outdoor unit

Y = DC Bypass for Quad band0 = bypass between port 1 and 41 = bypass between port 1 and Ant2 = bypass between port 2 and Ant3 = bypass between port 3 and Ant4 = bypass between port 4 and AntA = bypass through all portsN = bypass through none of the ports

Z = Connector type1 = N Female2 = DIN Female3 = Mini DIN Female

Penta-Band Combiner

X = single or double and indoor or outdoor application (indoor is IP65 and Outdoor is IP67)0 = single indoor unit1 = single outdoor unit2 = double indoor unit3 = double outdoor unit

Y = DC Bypass for Penta band0 = bypass between port 1 and 51 = bypass between port 1 and Ant2 = bypass between port 2 and Ant3 = bypass between port 3 and Ant4 = bypass between port 4 and Ant5 = bypass between port 5 and AntA = bypass through all portsN = bypass through none of the ports

Z = Connector type1 = N Female2 = DIN Female3 = Mini DIN Female

Page 19: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

19Filter Combiners- sdptelecom.com

Page 20: Filter Combiners - SDP Telecom a Molex Company · PDF fileFilter Combiners Capability Catalog ... be used as a combiner near the BTS or as a splitter near the antenna. ... is supplied

COM (16-05) Rev E

® ©

All

info

rmat

ion

cont

aine

d w

ithin

this

pro

duct

cat

alog

ue is

pro

prie

tary

and

is c

onsi

dere

d co

pyrig

ht o

f SD

P Te

leco

m.

Spe

cific

atio

ns s

ubje

ct to

cha

nge

with

out n

otic

e.

sdptelecom.com

Radio Link Waveguide

In-Building

SDP TELECOM ULC (Canada)119 Brunswick Blvd. Unit 600Pointe-Claire, Québec H9R 5N2, CanadaTel.: +1(514) 428-7070Fax: +1(514) 428 7051

SDP TELECOM (Suzhou) Ltd. (China)17b Suchun Industrial EstateNo.428 Xinglong StreetSuzhou Industrial ParkSuzhou, Jiangsu Province 215026ChinaTel.: +86 512 62836108Fax: +86 512 62836208

OTHER CATEGORIES WE SUPPORT: For details pertaining to >2,000 products, please contact your SDP representative.

Components