fingerprint terminal ac-2000 & ac-2100plus
TRANSCRIPT
Doc. Ver. : V1.1
JUN.,24.2019
R&D CenterUnion Community Co., Ltd.
Doc. Ver. : V1.1
JUN.,24.2019
R&D CenterUnion Community Co., Ltd.
Installation & Wiring Guide
FingerPrint Terminal
AC-2000 & AC-2100PLUS
Installation for AC-2000 & AC-2100PLUS V1.0 2
1. Cable Descriptions
1. Orange : EXIT : EXT2. Yellow : DM0 :DM03. Green : DM1 :DM15. Black : Gnd : GND6. Red : 5V : 5V7. Black : Gnd : GND8. Green : RS485A : R4A9. Blue : RS465B : R4B
10. Orange : WieOut0 : WO011. Yellow : WieOut1 : WO112. Brown : WieIN0 : WI013. Pink : WieIN1 : WI114. Black : Gnd : GND15. Black : E_TXP16. Blue: E_TXN17. Yellow : E_RXP18. Green : E_RXN19. Red : 12V IN : 12V20. Black : Gnd : GND
21.Red : 12V Out : 12V22.Gray : Lock 1 Com : L1C23.Brown : Lock 1 NC : L1NC24.White : Lock 1 NO : L1NO26. Black : Gnd : GND27. Black : Gnd : GND28. Black : Gnd : GND
M
128
P - 3
P - 2
P - 1
Installation for AC-2000 & AC-2100PLUS V1.0 3
2. Schematic for Door Lock Interface
T152
1
LOCK1_NO/MT
T151
1
T153
1
Wie_OUT14
W_IN14W_IN04
Wie_OUT04
RS485A4RS485B4
T158
1
T156
1
LOCK2
T155
1
T157
1
IN12V
CON-28P\SMDH200
DoorMntr1
T163
1
DoorMntr0
T165
1
T161
1
T164
1T159
1
T160
1
T166
1
InsideOpen
LOCK1_NCLOCK1_COM
N_TXN4N_TXP4
N_RXP4N_RXN4
PV159LVS16140C1
1 2
DoorMntr2
T162
1
J151FN200-H356-28-DJ-G
DoorM13
WieIN113
WieOut010
WieOut111
GND114
WieIN012
RS485B9
Lock_NO24
PGnd528
Lock_NC23
DoorM02
12VOut21
DC12V IN19
EXIT1
Eth_TXP15
Eth_TXN16
Eth_RXP17
Eth_RXN18
PGnd220
RS485A8
PGnd15
Lock_COM22
DoorM24
Lock225
5VOUT6
PwrGnd27
PGnd326
PGnd427
T154
1
LB157HH1M301J21 2
5V
LOCK1_COM
PV154A260LJT2
12
LOCK1_NC
D1521N4148W
12
D154S1A
12
LOCK1_NO/MT
PV160A260LJT2
12
PV161A260LJT2
12
K151AGQ200A4H
67
5
32
418
473
222 Q151KRC105S
B
EC
5VDC161104C
12
SOT23
LOCK_CON12
DC162104C1
12
Installation for AC-2000 & AC-2100PLUS V1.0 4
3. Connecting Dead-Bolt Type Door Lock (Fail Safe)
15 14
26. GND/(COM)
23. Lock1 NC
Inside DoorOpen S/W
2. DoorMontor0/(NC)
1. EXIT 27. GND128
21Pin, 22Pin Short
P - 3
P - 2
P - 1
3.1. Connecting One System/ One Lock <DB Door Signal>Closed: NO-COM, Short
NC-COM, OpenOpened: NO-COM, Open
NC-COM, Short
Installation for AC-2000 & AC-2100PLUS V1.0 5
3. Connecting Dead-Bolt Type Door Lock (Fail Safe)
1/28
1/28
21Pin, 22Pin Short
26. GND/(COM)
23. Lock1 NC
2. DoorMontor0/(NC)
S
y
s
t
e
m
2
S
y
s
t
e
m
1
3.2. Connecting Two Systems/ One Lock
22. Lock1 COM
26. GND
24. Lock1 NO
1. EXIT
<DB Door Signal>Closed: NO-COM, Short
NC-COM, OpenOpened: NO-COM, Open
NC-COM, Short
Installation for AC-2000 & AC-2100PLUS V1.0 6
26. GND
23. Lock 1NC
2. DoorMontor0/(NC)
4. Connecting Strike Type Door Lock (Fail Safe)
Inside DoorOpen S/W
1. EXIT 27. GND
21Pin, 22Pin Short
P - 3
P - 2
P - 1
128
4.1. Connecting One System/ One Lock
Installation for AC-2000 & AC-2100PLUS V1.0 7
4. Connecting Strike Type Door Lock (Fail Safe)
4.2. Connecting Two Systems/ One Lock
S
y
s
t
e
m
2
S
y
s
t
e
m
1
1/28
1/28
21Pin, 22Pin Short
26. GND
23. Lock1 NC
2. DoorMontor0/(NC)
22. Lock1 COM
26. GND
24. Lock1 NO
1. EXIT
Installation for AC-2000 & AC-2100PLUS V1.0 8
5. Connecting Strike Type Door Lock (Fail Secure)
26. GND
24. Lock 1NO
2. DoorMontor0/(NC)
Inside DoorOpen S/W
1. EXIT 27. GND
21Pin, 22Pin Short
P - 3
P - 2
P - 1
128
5.1. Connecting One System/ One Lock
Installation for AC-2000 & AC-2100PLUS V1.0 9
S
y
s
t
e
m
2
S
y
s
t
e
m
1
1/28
1/28
21Pin, 22Pin Short
26. GND
24. Lock1 NO
2. DoorMontor0/(NC)
22. Lock1 COM
26. GND
24. Lock1 NO
1. EXIT
5.2. Connecting Two Systems/ One Lock
5. Connecting Strike Type Door Lock (Fail Secure)
Installation for AC-2000 & AC-2100PLUS V1.0 10
6. Connecting an EM Type Door Lock (Fail Safe)
15 14
26. GND
23. Lock1 NC
2. DoorMontor0/(NC)
1. EXIT
27. GND/(COM)28 1
21Pin, 22Pin Short
P - 3
P - 2
P - 1
Inside DoorOpen S/W
6.1. Connecting One System/ One Lock<EM Door Signal>Closed: NO-COM, Short
NC-COM, OpenOpened: NO-COM, Open
NC-COM, Short
Installation for AC-2000 & AC-2100PLUS V1.0 11
6. Connecting an EM Type Door Lock (Fail Safe)
1/28
14/15
1/28
14/15
21Pin, 22Pin Short
26. GND
23. Lock 1 NC
2. DoorMontor0
S
y
s
t
e
m
2
S
y
s
t
e
m
1
6.2. Connecting Two Systems/ One Lock
24. Lock 1 NO
26. GND
22. Lock 1 COM
<EM Door Signal>Closed: NO-COM, Short
NC-COM, OpenOpened: NO-COM, Open
NC-COM, Short
Installation for AC-2000 & AC-2100PLUS V1.0 12
6. Connecting an EM Type Door Lock (Fail Safe)
15 14
26. GND/(COM)
23. Lock1 NC
Inside DoorOpen S/W
3. DoorMontor0/(NC)
1. EXIT 27. GND128
12V 3.5A
Adapter
6.3. Connecting One System/ Two Locks “ Use external DC Power adapter”
(+)(-)
13. GND
22. Lock 1 COM
<EM Door Signal>Closed: NO-COM, Short
NC-COM, OpenOpened: NO-COM, Open
NC-COM, Short
Installation for AC-2000 & AC-2100PLUS V1.0 13
7. Connecting Auto-Door (Contact Control)
Sensor Input Line
Auto-Door SensorAuto-Door Monitor
Auto Door Operating Part Auto Door Motor
22. Lock1 COM
24. Lock 1NO
1/28
14/15
7.1. Connecting One System/ One Door
Inside DoorOpen S/W
1. EXIT27. GND
Installation for AC-2000 & AC-2100PLUS V1.0 14
8. Connecting Auto-Door (Contact Control)
1/28
14/15
1/28
14/15
22. Lock1 COM
Sensor Input Line
Auto-Door Sensor Auto-Door Monitor
Auto Door Operating Part Auto Door Motor
24. Lock1 NO
S
y
s
t
e
m
1
S
y
s
t
e
m
2
7.2. Connecting Two Systems/ One Lock
24. Lock1 NO
22. Lock1 COM
1/28
14/15
1/28
14/15
22. Lock1 COM
Sensor Input Line
Auto-Door Sensor Auto-Door Monitor
Auto Door Operating Part Auto Door Motor
24. Lock1 NO
7.2. Connecting Two Systems/ One Lock
Installation for AC-2000 & AC-2100PLUS V1.0 15
9. Connecting Wiegand IN/OUT to External Controller
128
10. WieOut0
11. WieOut1
12. WieIN0
13. WieIN1
Installation for AC-2000 & AC-2100PLUS V1.0 16
10. Appendix
128
12. WieIN0
13. WieIN1
14. GND
10.1 How to connect the VS-R20D RF Dummy Card Reader SW51 Select S/W
ON [1]
OFF [0]
1 2 3 4 5 6
* 1, 2, 3 OFF: 26Bit* 4 ON: Wiegand Mode
Installation for AC-2000 & AC-2100PLUS V1.0 17
10. Appendix
128
12. WieIN0
13. WieIN1
14. GND
10.2 How to connect the VS-R20D SC Dummy Card Reader SW51 Select S/W
ON [1]
OFF [0]
1 2 3 4 5 6
* 1, 2, 3 ON: 34Bit* 4 ON: Wiegand Mode
Installation for AC-2000 & AC-2100PLUS V1.018
11.1 RS-485 Setting : Default Setting is off.
128
8. RS-485A
9. RS-485B
11.2 RS-485 Setting : ON: 120 Ohm Resistor is connected between 485A and 485B128
8. RS-485A
9. RS-485B
11. Resistor Setting for RS485 End Termination
120 Ohm Resistor
Installation for AC-2000 & AC-2100PLUS V1.019
12. Appendix
12. How to connect an external relay
** It is recommended to connect an external relay if a problem occurs after connection with
an external equipment such as a speed gate.
26. GND
24. Lock 1NO
21Pin, 22Pin Short
128
<Relay SPEC.>
Coil Voltage: 12V
Contact Current:
1A~2A
External
Relay
Installation for AC-2000 & AC-2100PLUS V1.0 20
Door
AWG20 * 2C
Adapter
AWG20 * 4C
AWG22 * 2C
13. Wiring Guide
13.1 Terminal & Exit Button
Installation for AC-2000 & AC-2100PLUS V1.0 21
Door
AWG20 * 2C
Adapter
AWG20 * 4C
AWG22 * 2C
13. Wiring Guide
13.2 Terminal & Exit Button
Installation for AC-2000 & AC-2100PLUS V1.0 22
13. Wiring Guide
13.3 Terminal & Exit Button
Door
Switch HubCAT. 5-4Pr.(UTP)
Server
AWG20 * 4C
CAT. 5-4Pr.(UTP)
AWG22 * 2C
Adapter
Lock Controller
( ex.BLC-015 )
AWG22 * 2C(RS485)
AWG20 * 2C(Power IN)
Installation for AC-2000 & AC-2100PLUS V1.0 23
13. Wiring Guide
13.4 Terminal & Exit Button
Door
Switch HubCAT. 5-4Pr.(UTP)
Server
AWG20 * 4C
CAT. 5-4Pr.(UTP)
AWG22 * 2C
Adapter
Lock Controller
( ex.BLC-015 )
AWG22 * 2C(RS485)
AWG20 * 2C(Power IN)