FL-YZD-KM3 GAS STATION LIGHT 12 YEARS FOCUS ON LED LIGHTING Power:60W/80W/90W/100W/120W /150W/160W/200W 3-5years warranty 60-200W LED Gas Station Light

Upload: others

Post on 09-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

FL-YZD-KM3GAS STATION LIGHT

12 YEARS FOCUS ON LED LIGHTING

Power:60W/80W/90W/100W/120W/150W/160W/200W

3-5yearswarranty

60-200WLED Gas Station Light

Page 2: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

CATALOGUEProduct electrical parameters 1

Product features 4

Chips 5

Beam angle 5

Product size 6

Explosion map 7

Package Size 8

Product installation 9

Applications 11

Installation Precautions 11

https://www.ledsolarstreetlight.com

https://flled.en.alibaba.com

https://fl-led.en.alibaba.com

Page 3: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

Product electrical parameters

1

Product FL-YZD-KM3-2-60W FL-YZD-KM3-2-80W FL-YZD-KM3-2-100W

Power 60W 80W 100W

Chip brandsPhilips / Osram/

Bridgelux

Philips / Osram/

Bridgelux

Philips / Osram/

Bridgelux

Chips 3030 3030 3030

Led quantity 112 112 112

Input voltage AC100-305V AC100-305V AC100-305V

Driver brands Mean well Mean well Mean well

Lumen 9941 lm 10390 lm 14386 lm

Luminous efficiency 160.2 lm/w 125.1 lm/w 142.0 lm/w

Beam angle90°

70° x100°60° x 135°

90°70° x100°60° x 135°

90°70° x100°60° x 135°

Color temp 3000-6500K 3000-6500K 3000-6500K

PF > 0.9 > 0.9 > 0.9

CRI 70-80 70-80 70-80

IP rating IP65 IP65 IP65

Working temp -30℃~+60℃ -30℃~+60℃ -30℃~+60℃

Boby material Aluminum+PC lens Aluminum+PC lens Aluminum+PC lens

Warranty 3-5 years 3-5 years 3-5 years

Page 4: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

2

Product FL-YZD-KM3-3-90W FL-YZD-KM3-3-120W FL-YZD-KM3-3-150W

Power 90W 120W 150W

Chip brandsPhilips / Osram/

Bridgelux

Philips / Osram/

Bridgelux

Philips / Osram/

Bridgelux

Chips 3030 3030 3030

Led quantity 168 168 168

Input voltage AC100-305V AC100-305V AC100-305V

Driver brands Mean well Mean well Mean well

Lumen 13463 lm 18775 lm 22471 lm

Luminous efficiency 148.6 lm/w 156.3 lm/w 149.7 lm/w

Beam angle90°

70° x100°60° x 135°

90°70° x100°60° x 135°

90°70° x100°60° x 135°

Color temp 3000-6500K 3000-6500K 3000-6500K

PF > 0.9 > 0.9 > 0.9

CRI 70-80 70-80 70-80

IP rating IP65 IP65 IP65

Working temp -30℃~+60℃ -30℃~+60℃ -30℃~+60℃

Boby material Aluminum+PC lens Aluminum+PC lens Aluminum+PC lens

Warranty 3-5 years 3-5 years 3-5 years

Page 5: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

3

Product FL-YZD-KM3-4-120W FL-YZD-KM3-4-160W FL-YZD-KM3-4-200W

Power 60W 80W 100W

Chip brandsPhilips / Osram/

Bridgelux

Philips / Osram/

Bridgelux

Philips / Osram/

Bridgelux

Chips 3030 3030 3030

Led quantity 112 112 112

Input voltage AC100-305V AC100-305V AC100-305V

Driver brands Mean well Mean well Mean well

Lumen 9941 lm 10390 lm 14386 lm

Luminous efficiency 160.2 lm/w 125.1 lm/w 142.0 lm/w

Beam angle90°

70° x100°60° x 135°

90°70° x100°60° x 135°

90°70° x100°60° x 135°

Color temp 3000-6500K 3000-6500K 3000-6500K

PF > 0.9 > 0.9 > 0.9

CRI 70-80 70-80 70-80

IP rating IP65 IP65 IP65

Working temp -30℃~+60℃ -30℃~+60℃ -30℃~+60℃

Boby material Aluminum+PC lens Aluminum+PC lens Aluminum+PC lens

Warranty 3-5 years 3-5 years 3-5 years

Page 6: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

4

Product features

■Light body with compact appearance and thickness only 4.65cm.

■Backside is fully enclosed treatment, at least IP65.

■Modules design heatsink, better heat dissipation.

■ Removable module design for facilitate maintenance.

■ Professional optical design, with world-renowned brands of led light sourcelight efficiency is 50% higher compare with traditional gas station canopy light.

Page 7: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

5

Beam angle

Chips

PHILIPS SMD 3030 SORUCE

Philips SMD 3030 LED source owns eletrostaticprotection component, maximally avoid thedamage of electrostatic. providing excellentlumen output, long-lasting stability and splendidsight.

90°

60°x135°

70°x100°

Page 8: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

6

Product size Labeling unit: mm

Page 9: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

7

Explosion map

Page 10: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

8

Package Size

FL-YZD-KM3-2: net weight: 5.3 kg; Gross weight: kg Size:45x38x16 cm

FL-YZD-KM3-3: net weight: 6.7 kg; Gross weight: 7.5 kg Size: 45x47x16 cm

FL-YZD-KM3-4: net weight: 7.4 kg; Gross weight: kg Size: 46x58x16 cm

Page 11: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

9

Labeling unit: mmProduct installationInstallation 1

People can operate above the ceiling

Step 1:Cut the ceiling hole accordingto the lamp size (reference holesize: two modules 320x220,Three modules 320x320, fourmodules 320x420).

Ceiling thickness <24mm

Step 2:Loosen the four screws ofthe two L-shaped piece,remove the two L-piecesand the fixed screws.

Step 3:Place the two L-pieces and thefixing screws above the ceilingfor further use.

Step 4:Push the lamp body downthe mounting hole.

Step6:Installation completed.

Step 5:Press the plate and L-shapedpieces close to the ceiling,adjust the hole position, tightenthe four fixed L-shaped screw.

Page 12: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

Installation 2

T

Step1:Measure the thickness of theceiling T and give the ceilingaperture according to the lampsize of the oil station (cutoutsize: 2 module 380x285mm,3module 380x380mm,4 module 380x475mm).

Step2:Loosen the 4 screws ofthe 2 L parts and pull theL parts upward.

Step3:Adjust the height to theceiling thickness T, tightenthe screws. If the ceiling isthick Degree is relativelylarge, you can rotate theL-shaped 180 ° piece forinstallation, as shown.

T

Ceiling thickness T: 42mm <T<66mm,L-shaped piece rotated 180 ° forinstallation

42m

m

66m

m

T<28mm

Step4:Lamps 45 ° inclinedinstall into the hole andconnect the Wiring.

Step5:Position the oil station lampin position and gently dropit at the mounting hole.

Step6:Installation completed.

10

Page 13: FL-YZD-KM3 GAS STATION LIGHT · Light body with compact appearance and thickness only 4.65cm. Backside is fully enclosed treatment, at least IP65. Modules design heatsink, better

11

Applications

Installation Precautions

FAX:86-0760-23757130TEL:86-0760-23757132

Widely used in gas stations, tunnels, airports, parking lots, toll booths, indoor garages and so on.

1.Make sure lamp installation and wiring in power outages condition, in case electric shock.

2. The lamp must be fixed strong, avoid lamp loose cause danger in future.

3. The power connection must be insulated and waterproof.

4.All lights with ground wire must be grounded , avoid leakage caused by electric shock and

to prevent the lamp suffered by lightning.

5.All lamps can not be installed inside the traditional lampshade (because the traditional

lampshade is a closed space, affecting the normal cooling of our lamps).

6.Before using the our lamps should know its protection level, prohibit using the lamp in

environment beyond protection level .