flat vertical - ...germany’s highest transmitter is operated by the bavarian broadcasting company...

9
FLAT VERTICAL Condensers GVH/GVV for all refrigerants Fluid coolers GFH/GFV for water/glycol and other fluids 8kW to 1,300kW Robust and variable – ideal for industrial refrigeration and air conditioning INFO

Upload: others

Post on 03-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

FLAT

VERTICALCondensers GVH/GVVfor all refrigerants Fluid coolers GFH/GFVfor water/glycol and other fluids

8kW to 1,300kW

Robust and variable – ideal for industrial refrigeration and air conditioning

INFO

Robust and variable

Güntner specialises in air-cooled condensers and dry cool-ers for all the usual fluids. Our FLAT and VERTICAL series have proved particularly popular and are continually being improved.

These extremely versatile units are available in horizontal or vertical design. Using the Güntner Product Calculator GPC you can quickly and easily design suitable condensers or dry coolers for your requirements.

You can choose from a very wide capacity range, a variety of fans for different noise emission requirements and an extensive programme of accessories.

Wide capacity range – Capacity range: 8kW – 1,300 kW – Large number of different types – Can be supplied for all refrigerants – Large selection of accessories

High-quality heat exchanger – Copper tubes for HFC and heat carriers – Stainless steel tubes for NH3

– Surface-corrugated aluminium fins for ease of cleaning and high heat transfer

– Staggered tube pattern – Various fin spacings

Suitable for all noise protection requirements – Different fan diameters – Different speeds – Night setback with Güntner controls

The Güntner Product Calculator GPC calcu-lates the optimum combination of fan number, diameter and speed for the customer’s specific noise requirements.

Robust casing – Torsion-resistant robust casing – All fan sections are separated from one another by separation sheets.

– Sheet steel, galvanised – Powder-coated in RAL 7035 – Special varnishing possible

2 3

Inspection and cleaning – Fans easily accessible – *Inspection cover – *Hinged fan plates

AC fans – Low-noise impeller with high efficiency – Two speeds as standard feature – Suitable for speed controllers – Motor protection with thermocontacts

Easy to install – Robust crane lugs to simplify transport by crane – Small number of feet and hence fewer bases, fewer attachments

– Factory-fitted assembly groups (switch cabinets, empty casing...)

EC fans – Low-noise impeller with a high level of efficiency – EC motors with a high level of efficiency – Individual speed adjustment – Integrated motor protection – Highly efficient operation and operational safety when used with Güntner Motor Management

High operational reliability and leak containment – Tried-and-tested Güntner proven floating coil principle (refrigerant tubes do not have contact with the casing, which increases the heat exchanger’s service life)

– Torsion-resistant casing for crane and forklift transport

All controls possibleAC fans – Step control, GMM step – Phase cutting control, GMM phasecut – Frequency controller with all-pole sine filter, GMM sincon

EC fans – Speed-controllable, GMM EC

Certificated capacity specificationAs part of the certification process, all series of a participating manufacturer are tested and con-firmed by specially approved laboratories. With units with the Eurovent certification seal of approv-al you can be assured that the specified capacity values are actually achieved.

Modular and flexible! – Numerous possible combinations – Configurable tube materials and geometries – Different fin spacings – Different diameter fans – Different numbers of fans

Tailored solutions for any application

*available as option

4 5

Reverse cycle for heat pump operation

Using a condenser as a heat pump evaporator (Special option, upon request)

A heat pump uses the thermal energy from the ambient air for heating. On the low-pressure side, cold is gener-ated while on the high-pressure side the heat is dissipat-ed. A refrigerating plant dissipates thermal energy to the ambient air.

For heat pumps, the operating principle is reversed. The generated thermal energy serves as heating whereas the cold is discharged to the ambient air. A heat pump offers a very high efficiency level of approx. 90 % and is one of the most efficient heating systems.

FluidsFor all HFCs and ammonia

*Accessories- Step controller, GMM Step- Frequency converters (VFD’s) with all-pole sine filter, GMM sincon- EC fans with Güntner Motor Management, GMM EC- Bus-enabled system for high level connectivity (modbus/profibus)- Pre-wired ready to operate

Heat exchanger technologies – finoox (fin and tube heat exchanger) offering a large surface

– Copper as standard, stainless steel tubes as option

– Aluminium as standard, aluminium/epoxy, copper and stainless steel fins as option

Types of casing options – Weather protection roof – Inlet hood – Air discharge hood – Stainless steel casing as option – FLAT, VERTICAL and V-SHAPE (GVD/GVW)

Adhering to norms and regulations – EU Directive 97/23/EC for pressure equipment (Pressure Equipment Directive)

– EN 378, Part 1 to 4: “Refrigerating systems and heat pumps, safety and environmental requirements”

Status: June 2008 EU Directive 2006/42/EC for machines (Machinery Directive)

We can also turn condensers into heat pump evapo-rators for you. This means that the connection system of the condenser is modified in a way it operates as heat pump connection. Based on your parameters and the employed fluid, Güntner calculates and designs the pipe circuiting. Then the condenser operates as DX heat pump evaporator.

And the best is yet to come: You can set the mode of operation to cooling during summer and to heating during winter.

No additional heating required Saves space Safe plant (no heating system integrated

into the building)

Coil orientation*Available in V-shape (GVD)

* Available as option

6 7

Controls

Güntner Motor Management (GMM) is an electronic module for controlling fans. The GMM system is available for AC or EC fans. A number of different technologies are used, but one feature is common to all management systems: They all provide various functions that serve to enhance energy efficiency and operational safety.

All GMM systems can be extended to include com-munication modules. Available modules include Modbus, Profibus and Gateway for Lon and BacNet.

GMMs can also be equipped with WiFi/LAN mod-ules. This module offers manifold communication possibilities.

You can use a smartphone or tablet to access the integrated web services, or use the Güntner Controls app to handle the entire controller setup process.

Energy-efficiency

Control

GMMphase cut

GMMstep

GMMf-drive

GMMsincon

AC fans

Investment

GMMEC

Maximum efficiency can be achieved with EC fans and the GMM EC.

A number of technologies are available for AC fans depending on the application.

EC fans

not so good very good

Cooling circuit

Speed controller

Precision

Noise

Investment costs

Service life

Cooling circuit

Speed controller

Precision

Noise

Investment costs

Service life

Cooling circuit

Speed controller

Precision

Noise

Investment costs

Service life

Cooling circuit

Speed controller

Precision

Noise

Investment costs

Service life

Cooling circuit

Speed controller

Precision

Noise

Investment costs

Service life

Empfehlungenzur Materialauswahl

Güntner Wissen

für verschiedene Einsatzfälle und Umgebungsbedingungen

Korrosion vermeiden durch optimale Materialauswahl

Manifold combinations of materials

Integrated subcoolers

Refrigerant receiver

Multiple circuit coilEmpty casings for components installed on-site

Speed controllers and switch cabinets

Wide range of options and accessories

Increased corrosion protection Different applications with aggressive atmospheres require targeted material selection. We have compiled a brochure with recommendations for material selection.

www.guentner.asia/know-how/application-tipswww.guentner.asia/know-how/guentner-app

8 9

References

High cooling power – special assembly situationLondon is home to one of Europe’s largest shopping cen-tres. A total of 61 speed-controller-equipped Güntner dry coolers provide for a pleasant atmosphere. Such a large number of dry coolers calls for special measures for the

assembly and installation. The speed controllers ensure that the required noise levels can be complied with day and night.

Process coolingIn this factory, the company Glockenbrot produces baked goods for branches all over Germany. This involves processing 100 tonnes of flour every day. Güntner’s dry coolers cool the refrigeration units required for process cooling.

Altitude – extreme conditionsGermany’s highest transmitter is operated by the Bavarian broadcasting company BR in the Alps. Güntner dry coolers are in operation in all weathers at an altitude of 1800 m.

Fish processing – corrosion proofOne of Europe’s largest and most modern fish processing plants is on the Baltic island of Rügen. Erecting condensers and dry coolers on the coast calls for special anti-corrosion measures. Güntner’s special corrosion-proof condensers fulfil these requirements.

Stringent noise requirementsRefrigeration equipment with a total cooling power of 3.5 MW is installed at the Rinecker Proton Therapy Center. The location of the dry coolers called for a non-standard assembly and compliance with extra stringent noise requirements.

10 11

Protection of historic buildingsThe Altmarkt gallery in Dresden operates 20 GFH dry coolers to ensure a pleasant atmosphere. Utilising the “free cooling” operating mode saves energy amounting to 95,000 kWh per year. To protect the historic building the dry coolers were arranged at an angle and integrated into the building.

More at: www.guentner.asia/know-how/references12 13

Download your Güntner Product Calculator (GPC) for free.

www.guentner.asia

The Güntner Product Calculator GPC configuration software allows you to quickly and easily design the right unit for your individual application.

Simply enter the required parameters in the convenient entry screen of the GPC. The calculator will consider your specified operating conditions and selected accessories, perform the thermodynamic configuration and provide a selection of suitable units. Capacity specifications are stated in compliance with EUROVENT.

Use our software to select evaporators, condensers, air coolers, dry coolers, control units and switch cabinets!

Quickly and reliablethermodynamic calculation

and proposal submission

YOUR BENEFITS AT A GLANCE: – Thermodynamic calculation – Quick and safe configuration – Automatic coordination of individual unit components – Various units of measurement possible – Choice of 15 languages – Current prices and delivery times can be called up – Display of quickly deliverable units in stock

Fans

Heat Exchanger

450 / 500 / 650 / 800 / 900 mm

Fin geometry: H up to type 065 25 x 22 mm

From type 080. 50 x 25 mm with staggered tube pattern

Fin spacing 2.2 / 2.4 mm

1 – 12

Horizontal

Available Material

Material

Standard version

AIMgAluminiumCopperAluminium, epoxy-resin coatedSteel, hot-dip galvanisedSheet steel, galvanizedStainless steel, V2A 304Stainless steel, V2A 316

Fin CasingTube

Other

Epoxy resin-coated finsSpecial varnishingEC fans Inspection coverVibration dampersFlange connectionExtended legsEmpty casingsMax. operating pressure 41 barMade of stainless steel

Controls

GMM ECGMM sincon®

GMM phase cutGMM step

Switch cabinetRepair switch

NMLSENMLSENMLSE

GVH/GVV

AGVH/AGVV

GFH/GFV

19,8 – 1180 kW 70,2 – 1126 kW 14,6 – 961 kW11,7 – 681 kW13,8 – 624 kW47,8 – 1310 kW76,0 – 1158 kW34,4 – 986 kW23,8 – 704 kW21,5 – 652 kW24,3 – 929 kW 60,8 – 965 kW 17,9 – 732 kW 14,1 – 585 kW14,1 – 527 kW

47 – 67 dB(A)45 – 64 dB(A)36 – 60 dB(A)31 – 48 dB(A)28 – 49 dB(A)54 – 67 dB(A)45 – 64 dB(A)47 – 60 dB(A)40 – 52 dB(A)35 – 49 dB(A)49 – 67 dB(A)45 – 63 dB(A)39 – 60 dB(A)31 – 52 dB(A)31 – 49 dB(A)

HFCHFCHFCHFCHFCNHCNH3

NH3

NH3

NH3

Heat carriersHeat carriersHeat carriersHeat carriersHeat carriers

RefrigerantSound level Nominal capacity*Sound pressure level**

Liquid receivers

HorizontalVertical

Multiple circuit coilSeparate heat exchanger

Subcooler

Vertical

Available Accessories

Product types / Refrigerant / OutputOrientation

** at a distance of 10 metres as per EN 13487* tLE 25 °C, tC 40 °C

Members of Güntner Group

Guntner Asia Pacific Pte., Ltd. 8 Jurong Town Hall Road#23-06 The JTC SummitSingapore 609434

www.guentner.asia

Subj

ect t

o te

chni

cal c

hang

es. A

PO /

INFO

/ H

EATP

UM

P / E

N /

MAR

201

6