flexibility 1
TRANSCRIPT
-
8/8/2019 Flexibility 1
1/84
Page 305 of 529
Page 285
FLEXIBILITY ANALYSIS
INTRODUCTION
Flexibility Analysis is a subject which is more talked about and less
understood
Flexibility Analysis is done on the Piping System to study the behaviour
on the same, when it changes the temperature from ambient / installed
to operating, so as to arrive at the most economical layout.
There are mainly three sets of conditions which define the minimum
acceptable flexibility on a piping configuration. They are:
1. The maximum allowable stress range in the system.
2. The limiting values of forces and moments which the system is
permitted to impose on the equipment to which it is connected.
3. The maximum allowable stress on the supporting structure.
When piping is connected to strain sensitive equipments, the flexibility
required to satisfy the acceptable limits of forces and moments
overrides that required to satisfy the maximum stress range conditions
and overstressing of supporting structures.
The Piping Engineer ahs the following choices to establish that the
required flexibility has been provided in the layout.
1. A per clause 319.4.1 of the code ASME B 31.3 which specifies
that no formal analysis is required in systems which.a) are duplicates of successfully operating installations or
replacements.
b) Can really be judged adequate by comparison with previously
analysed systems.
-
8/8/2019 Flexibility 1
2/84
Page 306 of 529
c) Satisfies the equation (16) specified in clause 319.4.1
2. Analysing the layout by an appropriate method.
3. Carrying out a comprehensive analysis.
Let us consider those aspects in the code which are mandatoryrequirements for the expansion and flexibility of metallic piping.
Pipe is erected at ambient temperature and that depends on the climatic
conditions. 700F (210C) is the figure commonly used for calculations. The
same piping when in operation is a Petrochemical Plant could achieve a
temperature in excess of 5000C if it were in a reactor piping system or it
could be of the order of - 1200C if it were associated with Ethylene
refrigeration System.Each material has it own coefficient of thermal expansion. If the pipe is
carbon steel or low alloy steel each 100 ft will expand at the rate o to 1
or each 1000 F temperature rise. This means that the pipe running between
two equipments 100 t. apart may well want to expand to 4 inches more as
it heats up. The increased length can be accommodated only by straining
the pipe as the ends are not free to move. This straining induces stress in
the pipe. However when the line is cooled during shutdown to ambient
temperature the expansion returns to zero, the straining I no longer
required and hence stress also disappears.
Page 286
Everytime the plants is in operation and in shut-down, the same cycle occurs. The pipe starts from stress free condition when cold, getstress imposed which reaches the maximum at operating condition and reduce to zero when operation stops and system cools down.
But this is not what exactly happens practically. The piping system can absorb
displacement without returning exactly to previous configuration. Relaxation to
the sustaining level of material will tend to establish a condition of stability in few
-
8/8/2019 Flexibility 1
3/84
Page 307 of 529
cycles, each cycle lowering the upper limit of hot stress until a state of equilibrium
is reached in which the system is completely relaxed and capable of maintaining
constant level of stress. The stress at which the material is relieved due to
relaxation appears as stress in the opposite temperature state, with equal
intensity but of opposite sign. Thus the system which originally was stress less
could within a few cycles accumulate stress in the cold condition and spring itself
without the application of external load. This phenomenon is called self
springing;. This can be demonstrated as below :
24000 psi
4 EXP
System Relaxed 6000 psi System Self Springing
To Sustaining Level
Let us assume that the system absorbs 4 expansion between anchors and the
calculated maximum stress is 24,000 psi. Suppose the material at the particular
operating temperature can sustain only 18,000 psi or of the developed stress,
yielding will take place to its sustaining level. On cooling back to ambient
temperature the system must contract by 4. At of this contraction, i.e. at 3 the
system will become stress less. Completion of contraction through remaining 1
will result in a stress of 6000 psi in the opposite direction. The system which wasstressless at the start will now cold spring. Hence it is evident that the true
magnitude of the stress either in hot or cold condition cannot be determined by
calculation because the amount of relaxation is unknown and cannot be judged
reliably. However service failure are related to cyclic rather than static conditions
and it is therefore permissible to assume that the system will operate.
-
8/8/2019 Flexibility 1
4/84
Page 308 of 529
Page 287
-
8/8/2019 Flexibility 1
5/84
Page 309 of 529
Page 288
-
8/8/2019 Flexibility 1
6/84
Page 310 of 529
Page 289
-
8/8/2019 Flexibility 1
7/84
Page 311 of 529
Page 290
-
8/8/2019 Flexibility 1
8/84
Page 312 of 529
Page 291
-
8/8/2019 Flexibility 1
9/84
Page 313 of 529
Page 292
-
8/8/2019 Flexibility 1
10/84
Page 314 of 529
Page 293
For this type of application, calculate the vertical force component of the verticalconnection excluding pressure loading. Compare with value of 1/5 the pressure loading.
Use the larger of these two numbers for vertical force component on connections inmaking calculations outlined in (1) and (2)
The force caused by the pressure loading on the vertical connections is allowed in
addition to the values established in the above up to a maximum value of vertical force
(lbs.) on the connection (including pressure loading) of 151/2 times the connection area in
square inches.
These values of allowable forces and moments pertain to the compressor structure only.They do not pertain to the forces and moments in the connecting piping flanges and
flange bolting which should not exceed the allowable stress as defined by applicable
codes and explanatory notes.
Forces on inlet connections are to be transferred along with moments to discharge
connection to analyze the compressor for resultant forces and moments. But, the transfer
of force will generate additional transfer moments which are added to the total ofmoments to give resultant moments.
-
8/8/2019 Flexibility 1
11/84
Page 315 of 529
Page 294
-
8/8/2019 Flexibility 1
12/84
Page 316 of 529
Page 295
RECIPROCATING COMPRESSORS
API 618 Reciprocating Compressor for General Refinery Service do not specify thelimit on the allowable forces and moments in the code. The vendor shall specify the
forces and moments for each nozzle in the tabular form. However, the values are as per
API 610 can considered for guidance.
FIRED HEATERS
The limiting values for forces and moments should be laid down by the manufactures.Restrictions are applied on nozzle rotations also in this case to take care of the clearnaces
between the tube and refractory lining.
The thumb rule is used is:
Forces = 200 to 300 lb/in nominal bore of nozzle
Moments Equivalent to Sh/4
Nozzle Rotation From 1/20
to 10
SHELL & TUBE TYPE HEAT EXCHANGERS
The designer has to set the limiting values or check the vessel connections for the nozzle
loading imposed by the connected piping.
The rough guide generally followed is:-
Resultant Maximum Force 200lb/in NB of nozzle
Bending Moment Equivalent to bending stress in standard schedule
Pipe between 40000 to 5000 lbs/in2
-
8/8/2019 Flexibility 1
13/84
Page 317 of 529
Page 296
-
8/8/2019 Flexibility 1
14/84
Page 318 of 529
Page 297
-
8/8/2019 Flexibility 1
15/84
Page 319 of 529
-
8/8/2019 Flexibility 1
16/84
Page 320 of 529
Page 298
-
8/8/2019 Flexibility 1
17/84
Page 321 of 529
Page 299
-
8/8/2019 Flexibility 1
18/84
Page 322 of 529
Page 300
-
8/8/2019 Flexibility 1
19/84
Page 323 of 529
Page 301
-
8/8/2019 Flexibility 1
20/84
Page 324 of 529
Page 302
-
8/8/2019 Flexibility 1
21/84
Page 325 of 529
Page 303
-
8/8/2019 Flexibility 1
22/84
Page 326 of 529
Page 304
-
8/8/2019 Flexibility 1
23/84
Page 327 of 529
Page 305
-
8/8/2019 Flexibility 1
24/84
Page 328 of 529
Page 306
-
8/8/2019 Flexibility 1
25/84
Page 329 of 529
Page 307
-
8/8/2019 Flexibility 1
26/84
Page 330 of 529
Page 308
-
8/8/2019 Flexibility 1
27/84
Page 331 of 529
Page 309
-
8/8/2019 Flexibility 1
28/84
Page 332 of 529
Page 310
-
8/8/2019 Flexibility 1
29/84
Page 333 of 529
Page 311
-
8/8/2019 Flexibility 1
30/84
Page 334 of 529
Page 312
-
8/8/2019 Flexibility 1
31/84
Page 335 of 529
Page 313
-
8/8/2019 Flexibility 1
32/84
Page 336 of 529
Page 314
-
8/8/2019 Flexibility 1
33/84
Page 337 of 529
Page 315
-
8/8/2019 Flexibility 1
34/84
Page 338 of 529
Page 316
-
8/8/2019 Flexibility 1
35/84
Page 339 of 529
Page 317
-
8/8/2019 Flexibility 1
36/84
Page 340 of 529
Page 318
-
8/8/2019 Flexibility 1
37/84
Page 341 of 529
Page 319
-
8/8/2019 Flexibility 1
38/84
Page 342 of 529
Page 320
-
8/8/2019 Flexibility 1
39/84
Page 343 of 529
Page 321
-
8/8/2019 Flexibility 1
40/84
Page 344 of 529
Page 322
-
8/8/2019 Flexibility 1
41/84
Page 345 of 529
Page 323
-
8/8/2019 Flexibility 1
42/84
Page 346 of 529
Page 324
-
8/8/2019 Flexibility 1
43/84
Page 347 of 529
Page 325
-
8/8/2019 Flexibility 1
44/84
Page 348 of 529
Page 326
-
8/8/2019 Flexibility 1
45/84
Page 349 of 529
327
SELECTION OF SPRING SUPPORTS
When vertical displacement occurs as a result of thermal expansion, it is necessary to
provide spring supports which applies supporting force throughout the expansion and
contraction cycle of the system.
Spring supports are of two types.
A. Constant Spring
B. Variable Spring
CONSTANT SPRING
Constant spring hangers provide constant supporting force for piping throughout its full
range of expansion and contraction. This is accomplished by a helical coil spring working
in conjunction with a bell crank lever in such a way that the spring force times itsdistance to liver pivot is always equal to the pipe load times its distance to liver pivot.
CONSTANT SUPPORT
Because of the consistency in supporting effect these are used for the support of critical
piping systems. Depending upon the structure availability, headroom, location of pipe
above or below, the type could be selected. The hanger size is selected from the LoadTravel Table. The travel shown in the table is the total travel that is the maximum
vertical movement which the hanger will accommodate. The total travel of pipe to allow
for any discrepancy. Hence the total travel = Actual travel + Over travel.
-
8/8/2019 Flexibility 1
46/84
Page 350 of 529
The over travel shall be 20% of calculate Actual travel and in no case less than 10mm.
Page 328
VARIABLE SPRING
Variable spring hangers are used to support are used to support piping subject to vertical
movement where constant supports are not required.
In this case, the supporting force varies with spring deflection and spring scale. Thevariation of supporting force is equal to the product of the amount of vertical expansion
and the spring scale of the hanger. Since the pipe weight is the same during any
condition, cold or operating, the variation In supporting force results in additional stresses
in the piping system.
Accepted practice is to limit the amount of supporting force variation to 25%.
The spring hangers are specified by the series, the type and the hanger size.
1. How to select series
The selection of the hanger series shall be done to limit the supporting force within the
allowable range. In choosing between the series VSI, VS2, and VS3 it must bedetermined that the calculated movement will fall within the working load range. The
series VS1 has the maximum variation in supporting force and hence not a competitiveselection but an invention of necessity where head room is not sufficient to use VS2.
Good engineering sense combined with available space and reasonable economic
considerations should ultimately determine which series of variable spring hangers
should be used.
2. How to determine type
The type of variable spring to be used depends upon the physical characteristics required
by the suspension problem i.e. available head room, pipe to be supported above thespring or below the spring etc. The type to be selected from the seven standard typesavailable. (see sketch for types A through G)
3. How to determine size
For determine the size of the hanger the load deflection table shall be preferred. In order
to choose the proper hanger size the data required is the actual load or the working load
-
8/8/2019 Flexibility 1
47/84
Page 351 of 529
(also called the hot load) and the amount and direction of the pipe line movement fromcold to hot.
Locate the hot load in the table. To determine the cold load, read the spring scale up or
down for the amount of expected movement. The chart must be read opposite from thedirection of pipe movement. The load arrived is cold load.
If the cold load falls outside the working load range of hanger selected, relocate the hot
load to the adjacent column and find the cold load. When both the hot and cold loads are
within the working range of a hanger, the size of the hanger is the number found at thetop of the column.
Should it be impossible to select a hanger in any series such that both loads fall within the
working range, consideration should be given for a constant spring hanger. Once
selected, the percentage load variation shall be checked as follows.
Travel x Spring Rate x 100
Load variation percentage =
Hot Load
Which should be within 25% as specified in the code.
-
8/8/2019 Flexibility 1
48/84
Page 352 of 529
Page 329
-
8/8/2019 Flexibility 1
49/84
Page 353 of 529
Page 331
-
8/8/2019 Flexibility 1
50/84
Page 354 of 529
Page 332
-
8/8/2019 Flexibility 1
51/84
Page 355 of 529
Page 333
-
8/8/2019 Flexibility 1
52/84
-
8/8/2019 Flexibility 1
53/84
Page 357 of 529
The support location is dependent on pipe size, piping configuration, the location ofheavy valves and specialties and the structure that is available for the support of the
piping.
The suggested maximum spans between supports normally adopted are as follows.
Pipe Size NB inch Span in M. (ft.)
1 2(7)
1-1/2 2.75(9)
2 3(10)
3 3.5 (12)
4 4(14)
Page 336
Pipe Size
NB inch
Span in
M. (ft.)
6 5(16)
8 5.75(18)
10 6.50(20)
12 7(23)
14 7.5(25)
16 8.25(27)
18 8.25(28)
20 9(30)
24 10(32)
The above spans are worked out on a combined bending and shear stress of 1500 psi
when the pipe is filled with water and 3 mm deflection is allowed between supports. Theydo not apply to concentrated loads or where change in direction occurs between supports.In case of concentrated loads, the support should be placed as close as possible. When
change in direction occurs, I is considered a good practice to keep the span to 75 % of the
tabulated valves.
In the illustrated example the support H1 is placed near to the equipment
flange A to reduce the load at the equipment to the minimum. Support H2
is located as per the standard span. Support H3 on the vertical leg is
-
8/8/2019 Flexibility 1
54/84
Page 358 of 529
placed above the center of gravity. Calculations would indicate that the CG
of the vertical lag falls t 16.16 ft above the lower horizontal run. If the
hanger would then act as pivot and would not resist sway. It could also be
checked with minimum leg calculation. The support H7 is placed adjacentto the valve weight concentration. The proximity of support to the valve is
helpful in keeping the load at the equipment flange B to a minimum or nil
as required. The support H6 is located as the standard support span. The
support H5 is located in such a way that the distance between H6 and H5
is not more than of the standard support span. The support H4 is
located clearing the bend and at standard support span distance from H5.
The methods involved in locating the supports for this problem are typical
of those employed by the piping engineer. Although the individual piping
configuration and structure layout will vary in practically every instance, the
general methods outlined above will apply for any critical piping system.
The Determination of Thermal Movement
The next step is to calculate the thermal movements at each location. The method
illustrated here gives satisfactory values. However this approximation will always give
positive error.
-
8/8/2019 Flexibility 1
55/84
Page 359 of 529
Page 337
-
8/8/2019 Flexibility 1
56/84
Page 360 of 529
Page 338
-
8/8/2019 Flexibility 1
57/84
Page 361 of 529
Page 339
-
8/8/2019 Flexibility 1
58/84
Page 362 of 529
Page 340
-
8/8/2019 Flexibility 1
59/84
Page 363 of 529
Page 341
-
8/8/2019 Flexibility 1
60/84
Page 364 of 529
Page 342
-
8/8/2019 Flexibility 1
61/84
-
8/8/2019 Flexibility 1
62/84
Page 366 of 529
Page 344
-
8/8/2019 Flexibility 1
63/84
Page 367 of 529
Page 345
-
8/8/2019 Flexibility 1
64/84
Page 368 of 529
Page 346
-
8/8/2019 Flexibility 1
65/84
Page 369 of 529
Page 347
-
8/8/2019 Flexibility 1
66/84
Page 370 of 529
Page 348
-
8/8/2019 Flexibility 1
67/84
Page 371 of 529
Page 349
-
8/8/2019 Flexibility 1
68/84
Page 372 of 529
Page 350
-
8/8/2019 Flexibility 1
69/84
Page 373 of 529
Page 351
-
8/8/2019 Flexibility 1
70/84
Page 374 of 529
Page 352
-
8/8/2019 Flexibility 1
71/84
Page 375 of 529
Page 353
-
8/8/2019 Flexibility 1
72/84
Page 376 of 529
Page 354
-
8/8/2019 Flexibility 1
73/84
Page 377 of 529
Page 355
-
8/8/2019 Flexibility 1
74/84
Page 378 of 529
Page 356
-
8/8/2019 Flexibility 1
75/84
Page 379 of 529
Page 357
-
8/8/2019 Flexibility 1
76/84
Page 380 of 529
Page 358
-
8/8/2019 Flexibility 1
77/84
Page 381 of 529
Page 359
-
8/8/2019 Flexibility 1
78/84
Page 382 of 529
Page 360
-
8/8/2019 Flexibility 1
79/84
Page 383 of 529
Page 361
-
8/8/2019 Flexibility 1
80/84
Page 384 of 529
Page 362
-
8/8/2019 Flexibility 1
81/84
Page 385 of 529
Page 363
-
8/8/2019 Flexibility 1
82/84
Page 386 of 529
Page 364
-
8/8/2019 Flexibility 1
83/84
Page 387 of 529
Page 365
-
8/8/2019 Flexibility 1
84/84
Page 366