flexmaster snmp reference guide 9.6
TRANSCRIPT
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
1/22
Ruckus Wireless™ FlexMaster™ 9.6
SNMP Reference G uid e
Part N um ber 800-70430-001 Rev A
Published M ay 2013
w w w .ruckusw ireless.com
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
2/22
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
3/22
FlexMaster SNMP Reference Guide Rev A iii
Copyright Notice and Proprietary InformationCopyright 2013 Ruckus Wireless, Inc. All rights reserved.
No part of this documentation may be reproduced, transmitted, or translated, in any form or
by any means, electronic, mechanical, manual, optical, or otherwise, without prior written
permission of Ruckus Wireless, Inc. (“Ruckus”), or as expressly provided by under license
from Ruckus.
Destination Control Statement Technical data contained in this publication may be subject to the export control laws of the
United States of America. Disclosure to nationals of other countries contrary to United States
law is prohibited. It is the reader’s responsibility to determine the applicable regulations and
to comply with them.
Disclaimer THIS DOCUMENTATION AND ALL INFORMATION CONTAINED HEREIN (“MATERIAL”) IS
PROVIDED FOR GENERAL INFORMATION PURPOSES ONLY. RUCKUS AND ITS LICEN-
SORS MAKE NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO
THE MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY, NON-INFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE,
OR THAT THE MATERIAL IS ERROR-FREE, ACCURATE OR RELIABLE. RUCKUS
RESERVES THE RIGHT TO MAKE CHANGES OR UPDATES TO THE MATERIAL AT ANY
TIME.
Limitation of LiabilityIN NO EVENT SHALL RUCKUS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS,
REVENUE, DATA OR USE, INCURRED BY YOU OR ANY THIRD PARTY, WHETHER IN AN
ACTION IN CONTRACT OR TORT, ARISING FROM YOUR ACCESS TO, OR USE OF, THE
MATERIAL.
TrademarksRuckus Wireless, Bark Logo, Ruckus, ZoneFlex and FlexMaster are trademarks of Ruckus
Wireless, Inc. in the United States and other countries. All other product or company names
may be trademarks of their respective owners.
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
4/22
iv Ruckus Wireless, Inc.
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
5/22
FlexMaster SNMP Reference Guide Rev A v
A bo ut This G uide
About This GuideThisRuckus W ireless FlexM aster SN M P Reference G uide contains inform ation about
configuring and m onitoring FlexM aster Release 9.6 devices and supported Zo neFlexdevices using Sim ple N etw ork M anagem ent Protocol (SN M P).
NOTE: Refer to the FlexM aster 9.6 U ser G uide for SN M P server configuration
instructions.
This guide is written for service operators and system ad m inistrators who are respon-
sible for m anag ing, configuring, and troubleshooting Ruckus W ireless devices.
C onsequently, it assum es a basic w orking kno w ledge of local area netw orks, w ireless
netw orking , and w ireless devices. Prior know led ge and experience w ith SN M P w ould
be helpful.
NOTE: If a release note is shipped w ith your Ruckus W ireless product and the
inform ation there differs from the inform ation in this guide, follow the instructions in
the release note.
M ost user guides and release no tes are available in A dobe A crobat Reader Portable
D ocum ent Form at (PD F) or H TM L on the R uckus W ireless Support W eb site athttp://support.ruckusw ireless.com
(login required)
Documentat ion CommentsRuckus W ireless is interested in im proving its docum entation and w elcom es your
com m ents and suggestions. You can em ail your com m ents to Ruckus W ireless at
docs@ ruckusw ireless.com(login required)
W hen contacting us, please include the follow ing inform ation:
■ D ocum ent title
■ D ocum ent part num ber (on the cover page)
■ Page num ber (if appropriate)
For exam ple:
■ FlexM aster 9.6 SN M P Reference G uide
■ Part num ber: 800-70430-001 Rev A
■ Page 7
Please note that w e can only respond to com m ents and questions about Ruckus
W ireless product docum entation at this em ail address. Q uestions related to technical
sup port or sales should be directed in the first instance to your netw ork supplier.
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
6/22
vi Ruckus Wireless, Inc.
D ocum entation C om m ents
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
7/22
vii
A bout This G uide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
D ocum entation C om m ents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
1 Event MIBs
ruckusFM EventZD A dm inU pgrad eTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
ruckusFM EventZD A dm inRestartedTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ruckusFM EventZD A dm inShutdow nTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ruckusFM EventZD A PD eleteTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ruckusFM EventZD A PJoinTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ruckusFM EventZD A PLostTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ruckusFM EventZD A PLostH eartbeatTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ruckusFM EventZD System FailureRecovered . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ruckusFM EventZD System StartupTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ruckusFM M iscEventTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ruckusStandaloneA PBootTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ruckusStandaloneA PTransferCom pleteTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ruckusStandaloneA PC onnectivityProblem Trap . . . . . . . . . . . . . . . . . . . . . . . . . 7
ruckusStandaloneA PReconnectTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
ruckusFM C PU U sageTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
ruckusZD C PU U sageTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ruckusZD A PTrafficTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ruckusZD A PofclientsTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ruckusZD A PLostC onnectionTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ruckusZD A PC hannelC hangeTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
ruckusZD A PRebootTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Index
Contents
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
8/22
viii Ruckus Wireless, Inc.
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
9/22
FlexMaster SNMP Reference Guide Rev A 1
Event MIBs
1Event MIBs
U se the FlexM aster Event M IBs to retrieve inform ation about events that have
occurred on FlexM aster.
ruckusFMEventZDAdminUpgradeTrapM IB N am e ruckusFM EventZD A dm inU pg radeTrap
Events A dm in upgrade
Severity low
O ID 1.3.6.1.4.1.25053.2.3.1.41
Status current
O bjects ruckusFM EventZD Firm w areVersion
ruckusFM EventZD IPAddr
ruckusFM EventZD M odelN am e
ruckusFM EventZD SerialN um ber
D escription Triggered w hen there is a ZD up grade event. The ZD 's Firm w are
version and IP address and M odel nam e and Serial num ber areenclosed .
Recom m ended actions
N o action req uired .
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
10/22
2 Ruckus Wireless, Inc.
Event MIBs
ruckusFMEventZDAdminRestartedTrapM IB N am e ruckusFM EventZD A dm inRestartedTrap
Events A dm in restartSeverity low
O ID 1.3.6.1.4.1.25053.2.3.1.42
Status current
O bjects ruckusFM EventZD IPAddr
ruckusFM EventZD M odelN am e
ruckusFM EventZD SerialN um ber
D escription Triggered w hen there is a ZD restart event. The ZD 's IP address and
M odel nam e and Serial num ber are enclosed.Recom m ended actions
N o action req uired .
ruckusFMEventZDAdminShutdownTrapM IB N am e ruckusFM EventZD A dm inShutdow nTrap
Events event.adm in.shutdow n
Severity m inorO ID 1.3.6.1.4.1.25053.2.3.1.43
Status current
O bjects ruckusFM EventZD IPAddr
ruckusFM EventZD M odelN am e
ruckusFM EventZD SerialN um ber
D escription Triggered w hen there is a ZD shutdow n event. The ZD 's IP address
and M od el nam e and Serial num ber are enclosed.
Recom m ended actionsN o action req uired .
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
11/22
FlexMaster SNMP Reference Guide Rev A 3
Event MIBs
ruckusFMEventZDAPDeleteTrapM IB N am e ruckusFM EventZD A PD eleteTrap
EventsA P delete
Severity m inor
O ID 1.3.6.1.4.1.25053.2.3.1.44
Status current
O bjects ruckusFM EventA PIPAddr
ruckusFM EventA PM acA dd r
ruckusFM EventA PM odelN am e
ruckusFM EventZD IPAddr
ruckusFM EventZD M odelN am eruckusFM EventZD SerialN um ber
D escription Triggered w hen there is a AP delete event. The A P's IP address and
M ac add ress and M od el nam e, ZD 's IP address and M odel nam e
and Serial num ber are enclosed .
Recom m ended actions
N o action req uired .
ruckusFMEventZDAPJoinTrapM IB N am e ruckusFM EventZD A PJoinTrap
Events A P joined w ith reason
A P joined
Severity m edium
O ID 1.3.6.1.4.1.25053.2.3.1.45
Status current
O bjects ruckusFM EventA PIPAddrruckusFM EventA PM acA dd r
ruckusFM EventA PM odelN am e,
ruckusFM EventZD IPAddr
ruckusFM EventZD M odelN am e
ruckusFM EventZD SerialN um ber
D escription Triggered w hen there is an A P join event. The A P's IP address and
M ac add ress and M od el nam e, ZD 's IP address and M odel nam e
and Serial num ber are enclosed .
Recom m ended actions
N o action req uired .
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
12/22
4 Ruckus Wireless, Inc.
Event MIBs
ruckusFMEventZDAPLostTrapM IB N am e ruckusFM EventZD A PLostTrap
EventsA P lost
Severity m inor
O ID 1.3.6.1.4.1.25053.2.3.1.46
Status current
O bjects ruckusFM EventA PIPAddr
ruckusFM EventA PM acA dd r
ruckusFM EventA PM odelN am e
ruckusFM EventZD IPAddr
ruckusFM EventZD M odelN am eruckusFM EventZD SerialN um ber
D escription Triggered w hen A P lost contact for 20 m inutes or m ore. The A P's
IP address and M ac address and M odel nam e, ZD 's IP address and
M odel nam e and Serial num ber are enclosed.
Recom m ended actions
C heck connection stability betw een ZD and A P. If custom er know s
that this AP w ill never be used , this AP can be rem oved from the
ZD database.
ruckusFMEventZDAPLostHeartbeatTrapM IB N am e ruckusFM EventZD A PLostH eartbeatTrap
Events A P lost heartbeat
Severity m edium
O ID 1.3.6.1.4.1.25053.2.3.1.47
Status current
O bjects ruckusFM EventA PIPAddr
ruckusFM EventA PM acA dd r
ruckusFM EventA PM odelN am e
ruckusFM EventZD IPAddr
ruckusFM EventZD M odelN am e
ruckusFM EventZD SerialN um ber
D escription Triggered w hen A P loses 30-second heartbeats for 80 second s or
m ore. The A P's IP address and M A C add ress and M od el nam e, ZD 's
IP ad dress and M od el nam e and Serial num ber are enclosed.
Recom m ended actions
C heck connection stability betw een ZD and A P.
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
13/22
FlexMaster SNMP Reference Guide Rev A 5
Event MIBs
ruckusFMEventZDSystemFailureRecoveredM IB N am e ruckusFM EventZD System FailureRecovered
EventsZD System Failure R ecovered
Severity m edium
O ID 1.3.6.1.4.1.25053.2.3.1.48
Status current
O bjects ruckusFM EventZD IPAddr
ruckusFM EventZD SerialN um ber
ruckusFM EventZD M odelN am e
D escription Triggered up on ZD System Failure Recovery. The ZD 's IP address
and Serial num ber and M od el nam e are enclosed.Recom m ended actions
Verify ZD status in ZD user interface.
ruckusFMEventZDSystemStartupTrapM IB N am e ruckusFM EventZD System StartupTrap
Events System cold restarted
System w arm restarted
Severity m inor
O ID 1.3.6.1.4.1.25053.2.3.1.49
Status current
O bjects ruckusFM EventZD IPAddr
ruckusFM EventZD SerialN um ber
ruckusFM EventZD M odelN am e
D escription Triggered w hen there is a ZD cold restart or w arm restart event. The
ZD 's IP address and Serial num ber and M od el nam e are enclosed.Recom m ended actions
N o action req uired .
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
14/22
6 Ruckus Wireless, Inc.
Event MIBs
ruckusFMMiscEventTrap
NOTE: The ruckusFM M iscEventTrap req uires that the ZoneD irector and A P d evices
support the sam e set of traps.
N am e ruckusFM M iscEventTrap
Severity low
O ID 1.3.6.1.4.1.25053.2.3.1.1
Status current
O bjects ruckusFM EventD escription
D escription G eneric trap triggered by adm in specified m iscellaneous event.The Event D escription is enclosed.
Recom m ended actions
N o action req uired .
Events (various m essages)
ruckusStandaloneAPBootTrapM IB N am e ruckusStand aloneA PB ootTrap
Events standalone A P reboot
Severity m inor
Status current
O bjects ruckusFM EventA PIPAddr
ruckusFM EventA PM acA dd r
ruckusFM EventA PM odelN am e
ruckusFM EventA PSerialN um berruckusFM EventA PD eviceN am e
D escription Triggered w hen there is a standalone A P reb oot event. The A P's IP
address, M A C address, Serial num ber, D evice nam e, and M odel
nam e are enclosed.
Recom m ended actions
N o action req uired .
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
15/22
FlexMaster SNMP Reference Guide Rev A 7
Event MIBs
ruckusStandaloneAPTransferCompleteTrapM IB N am e ruckusStandaloneA PTransferC om pleteTrap
Eventsstandalone A P transfer com plete
Severity m inor
Status current
O bjects ruckusFM EventA PIPAddr
ruckusFM EventA PM acA dd r
ruckusFM EventA PM odelN am e
ruckusFM EventA PSerialN um ber
ruckusFM EventA PD eviceN am e
ruckusFM EventA PFirm w areVersion
D escription Triggered w hen there is a standalone A P transfer com plete event.
The A P's IP address, M A C address, Serial num ber, D evice nam e,
M odel nam e and Firm w are Version are enclosed.
Recom m ended actions
N o action req uired .
ruckusStandaloneAPConnectivityProblemTrap
M IB N am e ruckusStandaloneA PC onnectivityProblem Trap
Events stand alone A P connection problem
Severity m inor
Status current
O bjects ruckusFM EventA PIPAddr
ruckusFM EventA PM acA dd r
ruckusFM EventA PM odelN am e
ruckusFM EventA PSerialN um ber
ruckusFM EventA PD eviceN am e
D escription Triggered w hen there is a stand alone A P connection problem
event. The A P's IP address, M A C address, Serial num ber, D evice
nam e and M odel nam e are enclosed.
Recom m ended actions
N o action req uired .
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
16/22
8 Ruckus Wireless, Inc.
Event MIBs
ruckusStandaloneAPReconnectTrapM IB N am e ruckusStand aloneA PR econnectTrap
Eventsstand alone A P connection problem
Severity m inor
Status current
O bjects ruckusFM EventA PIPAddr
ruckusFM EventA PM acA dd r
ruckusFM EventA PM odelN am e
ruckusFM EventA PSerialN um ber
ruckusFM EventA PD eviceN am e
D escriptionTriggered w hen there is a standalone A P reconnect event. The A P's
IP address, M A C address, Serial num ber, D evice nam e and M odel
nam e are enclosed.
Recom m ended actions
N o action req uired .
ruckusFMCPUUsageTrapM IB N am e ruckusFM C PU U sageTrap
Events FM C PU usage exceeds the threshold value
Severity (enclosed)
Status current
O bjects ruckusFM A larm D efinitionC ode
ruckusFM A larm D eviceN am e
ruckusFM A larm Severity
ruckusFM A larm D eviceM ac
ruckusFM A larm C ategory
ruckusFM A larm TypeTextruckusFM A larm M essage
ruckusFM A larm D atetim e
D escription Triggered w hen FM C PU usage exceeds the threshold value. The
D efinition C ode, D evice N am e, and A larm Severity are enclosed.
Recom m ended actions
N o action req uired .
E MIB
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
17/22
FlexMaster SNMP Reference Guide Rev A 9
Event MIBs
ruckusZDCPUUsageTrapM IB N am e ruckusZD C PU U sageTrap
Events ZD C PU usage exceeds the threshold value
Severity (enclosed)
Status current
O bjects ruckusFM A larm D efinitionC ode
ruckusFM A larm D eviceN am e
ruckusFM A larm Severity
ruckusFM A larm D eviceM ac
ruckusFM A larm C ategory
ruckusFM A larm TypeText
ruckusFM A larm M essage
ruckusFM A larm D atetim e
D escription Triggered w hen ZD C PU usage exceeds the threshold value. The
D efinition C ode, D evice N am e, and A larm Severity are enclosed.
Recom m ended actions
N o action req uired .
ruckusZDAPTrafficTrapM IB N am e ruckusZD A PTrafficTrap
Events A P count exceed s the thresho ld value
Severity (enclosed)
Status current
O bjects ruckusFM A larm D efinitionC ode
ruckusFM A larm D eviceN am e
ruckusFM A larm Severity
ruckusFM A larm D eviceM acruckusFM A larm C ategory
ruckusFM A larm TypeText
ruckusFM A larm M essage
ruckusFM A larm D atetim e
D escription Triggered w hen the A P count exceeds the threshold value. The
D efinition C ode, D evice N am e, and A larm Severity are enclosed.
Recom m ended actions
N o action req uired .
Event MIBs
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
18/22
10 Ruckus Wireless, Inc.
Event MIBs
ruckusZDAPofclientsTrapM IB N am e ruckusZD A PofclientsTrap
Events num ber of A P clients exceeds the threshold value
Severity (enclosed)
Status current
O bjects ruckusFM A larm D efinitionC ode
ruckusFM A larm D eviceN am e
ruckusFM A larm Severity
ruckusFM A larm D eviceM ac
ruckusFM A larm C ategory
ruckusFM A larm TypeText
ruckusFM A larm M essage
ruckusFM A larm D atetim e
D escription Triggered w hen the num ber of A P clients exceed s the threshold
value. The D efinition C ode, D evice N am e, and A larm Severity are
enclosed .
Recom m ended actions
N o action req uired .
ruckusZDAPLostConnectionTrapM IB N am e ruckusZD A PLostC onnectionTrap
Events ZD and A P lost their connection
Severity (enclosed)
Status current
O bjects ruckusFM A larm D efinitionC ode
ruckusFM A larm D eviceN am e
ruckusFM A larm SeverityruckusFM A larm D eviceM ac
ruckusFM A larm C ategory
ruckusFM A larm TypeText
ruckusFM A larm M essage
ruckusFM A larm D atetim e
D escription Triggered w hen the ZD and A P lost their connection. The D efinition
C ode, D evice N am e, and A larm Severity are enclosed .
Recom m ended actionsN o action req uired .
Event MIBs
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
19/22
FlexMaster SNMP Reference Guide Rev A 11
Event MIBs
ruckusZDAPChannelChangeTrapM IB N am e ruckusZD A PC hannelC hangeTrap
Events A P channel changes
Severity (enclosed)
Status current
O bjects ruckusFM A larm D efinitionC ode
ruckusFM A larm D eviceN am e
ruckusFM A larm Severity
ruckusFM A larm D eviceM ac
ruckusFM A larm C ategory
ruckusFM A larm TypeText
ruckusFM A larm M essage
ruckusFM A larm D atetim e
D escription Triggered w hen the A P channel changes. The D efinition C ode,
D evice N am e, and A larm Severity are enclosed .
Recom m ended actions
N o action req uired .
ruckusZDAPRebootTrapM IB N am e ruckusZD A PRebootTrap
Events ZD -controlled A P reb oot
Severity (enclosed)
Status current
O bjects ruckusFM A larm D efinitionC ode
ruckusFM A larm D eviceN am e
ruckusFM A larm Severity
ruckusFM A larm D eviceM acruckusFM A larm C ategory
ruckusFM A larm TypeText
ruckusFM A larm M essage
ruckusFM A larm D atetim e
D escription Triggered w hen a ZD -controlled A P reb oots. The D efinition C ode,
D evice N am e, and A larm Severity are enclosed .
Recom m ended actions
N o action req uired .
Event MIBs
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
20/22
12 Ruckus Wireless, Inc.
Event MIBs
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
21/22
FlexMaster SNMP Reference Guide Rev A 13
Index
RruckusFM C PU U sageTrap 8
ruckusFM EventZD A dm inRestartedTrap 2
ruckusFM EventZD A dm inShutdow nTrap 2
ruckusFM EventZD A dm inU pg radeTrap 1
ruckusFM EventZD A PD eleteTrap 3
ruckusFM EventZD A PJoinTrap 3
ruckusFM EventZD A PLostH eartbeatTrap 4
ruckusFM EventZD A PLostTrap 4
ruckusFM EventZD System FailureRecovered 5
ruckusFM EventZD System StartupTrap 5
ruckusFM M iscEventTrap 6
ruckusStand aloneA PB ootTrap 6
ruckusStandaloneA PC onnectivityProblem Trap 7
ruckusStand aloneA PR econnectTrap 8
ruckusStand aloneA PTransferC om pleteTrap 7
ruckusZD A PC hannelC hangeTrap 11
ruckusZD A PLo stC onnectionTrap 10
ruckusZD A PofclientsTrap 10
ruckusZD A PReboo tTrap 11
ruckusZD A PTrafficTrap 9
ruckusZD C PU U sageTrap 9
-
8/9/2019 FlexMaster SNMP Reference Guide 9.6
22/22
Copyright © 2006-2013. Ruckus Wireless, Inc.350 West Java Dr. Sunnyvale, CA 94089. USA www.ruckuswireless.com