Page 1: Flowmeters

Calibration of flowmeters

When a competent supplier is essential• Factory calibrations from DN1 to DN2000

• On-site calibration using mobile calibration rig minimizes production downtime

• Adjustment, repair, service and consultation as required

Page 2: Flowmeters

Instruments International

Endress+Hauser Instruments International AGKägenstrasse 24153 ReinachSwitzerlandTel. +41 61 715 81 00Fax +41 61 715 25 00http://[email protected]

Other locations

Please visit: www.endress.com/worldwide

IN00104H/29/EN/01.06PF/INDD CS4

Long-term stability and guaranteed precision are essential requirements for flow measurement instruments. Regular calibration is particularly important for measuring points that have a bearing on quality and safety.

Calibration of flowmeters

On-site or factory calibration?With one of our mobile calibration rigs, flow measurement instruments can be calibrated quickly on-site – often with the instrument still installed – by comparing the flow measurement instrument against a certified reference in the calibration unit. This saves time and money, and the cost benefits are even greater if several instruments require calibration. If the required precision cannot be obtained using the mobile facility, the instruments exceed the nominal range that can be handled on-site, or maybe only a single instrument requires calibration, then one of our accredited calibration centres is probably more suitable. Here, your measurement instruments are calibrated, and adjusted if required, within a guaranteed timeframe.

Place of calibration On-site In the laboratory (at E+H)

Calibration range

0.3 to 200 m3/hDN4 to DN125

Others may be possible following consultation

0 to 5760 m3/hDN1 to DN2000

Equipment concerned

• Electromagnetic flowmeters • Vortex flowmeters • Coriolis flowmeters• Thermal flowmeters• Ultrasonic flowmeters • Mechanical flowmeters • Others on request

• Electromagnetic flowmeters • Vortex flowmeters • Coriolis flowmeters• Thermal flowmeters• Ultrasonic flowmeters • Mechanical flowmeters

Calibration method Comparison with a specific master flowmeter connected in series

• Volumetric• Gravimetric• Master-Slave

Number of calibration points 3 points 1, 3, 5 points

(others by special agreements)

Resources used Mobile rig with specific master flowmeter

• Volumetrically with calibrated vessels• Gravimetrically with weighing scales• Master using mass flowmeters or

electromagnetic flowmeters

Metrological compliance

To national and international standards

To national and international standards or SCS 052 accreditation

Documents issued

• Calibration certificate• On request, copy of the proof

of conformity to national/international standards

• Calibration certificate• On request, copy of the proof of

conformity to national/international standards