flush mounted corner guards · 2017-11-04 · flush mounted corner guards 24fmcg important notes 1....

6
FLUSH MOUNTED CORNER GUARDS 24FMCG IMPORTANT NOTES 1. ALL MATERIAL TO BE SUPPLIED IN STOCK LENGTHS. ALUMINUM RETAINER AND ACROVYN COVERS IN LENGTHS UP TO 20'-0". THIS MATERIAL IS TO BE FIELD CUT USING QUALITY EQUIPMENT TO ENSURE THAT ALL CUTS ARE SQUARE. WHEN CUTTING MATERIAL SECTIONS, CS RECOMMENDS USING AN 80-100 TOOTH CARBIDE TIPPED SAW BLADE OR EQUIVALENT, TO MINIMIZE CHIPPING AND MAINTAIN JOINT ALIGNMENT. 2. ALL DIMENSIONS ARE TYPICAL. 3. FOR DRYWALL/PLASTER WALL CONSTRUCTION, IT IS RECOMMENDED FOR FASTENERS TO BE ENGAGED INTO METAL/WOOD STUDS TO MAINTAIN MAXIMUM PULLOUT STRENGTH. IF DURING INSTALLATION YOU ENCOUNTER SPECIAL WALL CONDITIONS THAT DO NOT ALLOW FOR DIRECT ATTACHMENT TO THE STUDS PLEASE CONSULT THE LOCAL AUTHORITY HAVING JURISDICTION. 4. MATERIAL MUST REACH 65°F MIN. TO 75°F MAX. 24 HOURS PRIOR TO INSTALLATION. THIS IS ESSENTIAL TO MINIMIZE EXPANSION AND CONTRACTION OF MATERIAL. 5. DUE TO 1 1/4" [31.8mm] NOSE RADIUS IT IS NOT RECOMMENDED TO INSTALL FS-10N, FS-10MN, OR SFS-10N AT PARTIAL HEIGHT. 6. FOR MORE INFORMATION ON FLUSH MOUNTED CORNER GUARDS SEE OUR WEBSITE AT www.c-sgroup.com. SECTIONAL VIEW PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE FLUSH MOUNTED CORNER GUARD INSTALLATION! THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION OF THIS FLUSH MOUNTED CORNER GUARD. CONTAINED WITHIN IS THE TECHNICAL INFORMATION AND INSTALLATION TECHNIQUES REQUIRED TO COMPLETE AN EFFICIENT, NEAT AND LONG-LASTING INSTALLATION. INSPECT ALL MATERIALS FOR DAMAGE OR MISSING PARTS. IF YOU DISCOVER DAMAGED OR MISSING MATERIALS, IN THE USA PLEASE NOTIFY THE FACTORY AT (800) 233-8493, AND IN CANADA (888) 895-8955 FOR CUSTOMER SERVICE. FLUSH MOUNTED CORNER GUARD MUST BE INSTALLED IN ACCORDANCE WITH THESE INSTRUCTIONS! FAILURE TO FOLLOW THESE INSTRUCTIONS MAY VOID ANY PRODUCT WARRANTIES AND RESULT IN AN UNSUCCESSFUL INSTALLATION. FOR SPECIFIC QUESTIONS REGARDING THE INSTALLATION OF THIS FLUSH MOUNTED CORNER GUARD PLEASE CALL THE FACTORY IN THE USA AT (800) 233-8493 OR EMAIL [email protected]. IN CANADA CALL (888) 895-8955. G.W.B (BY OTHERS) FEATHERED JOINT CEMENT LEG LENGTH LEG LENGTH R1/4" [R6.3mm] Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16

Upload: others

Post on 06-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FLUSH MOUNTED CORNER GUARDS · 2017-11-04 · flush mounted corner guards 24fmcg important notes 1. all material to be supplied in stock lengths. aluminum retainer and acrovyn covers

FLUSH MOUNTED CORNER GUARDS

24FMCG

IMPORTANT NOTES

1. ALL MATERIAL TO BE SUPPLIED IN STOCK LENGTHS. ALUMINUM RETAINER AND ACROVYN COVERS IN LENGTHS UP TO 20'-0".

THIS MATERIAL IS TO BE FIELD CUT USING QUALITY EQUIPMENT TO ENSURE THAT ALL CUTS ARE SQUARE. WHEN CUTTING

MATERIAL SECTIONS, CS RECOMMENDS USING AN 80-100 TOOTH CARBIDE TIPPED SAW BLADE OR EQUIVALENT, TO MINIMIZE

CHIPPING AND MAINTAIN JOINT ALIGNMENT.

2. ALL DIMENSIONS ARE TYPICAL.

3. FOR DRYWALL/PLASTER WALL CONSTRUCTION, IT IS RECOMMENDED FOR FASTENERS TO BE ENGAGED INTO METAL/WOOD

STUDS TO MAINTAIN MAXIMUM PULLOUT STRENGTH. IF DURING INSTALLATION YOU ENCOUNTER SPECIAL WALL CONDITIONS

THAT DO NOT ALLOW FOR DIRECT ATTACHMENT TO THE STUDS PLEASE CONSULT THE LOCAL AUTHORITY HAVING

JURISDICTION.

4. MATERIAL MUST REACH 65°F MIN. TO 75°F MAX. 24 HOURS PRIOR TO INSTALLATION. THIS IS ESSENTIAL TO MINIMIZE EXPANSION

AND CONTRACTION OF MATERIAL.

5. DUE TO 1 1/4" [31.8mm] NOSE RADIUS IT IS NOT RECOMMENDED TO INSTALL FS-10N, FS-10MN, OR SFS-10N AT PARTIAL HEIGHT.

6. FOR MORE INFORMATION ON FLUSH MOUNTED CORNER GUARDS SEE OUR WEBSITE AT www.c-sgroup.com.

SECTIONAL VIEW

PLEASE READ

PLEASE READ THESE INSTRUCTIONS THOROUGHLY

PRIOR TO BEGINNING THE FLUSH MOUNTED

CORNER GUARD INSTALLATION!

THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A

SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION

OF THIS FLUSH MOUNTED CORNER GUARD.

CONTAINED WITHIN IS THE TECHNICAL INFORMATION

AND INSTALLATION TECHNIQUES REQUIRED TO

COMPLETE AN EFFICIENT, NEAT AND LONG-LASTING

INSTALLATION.

INSPECT ALL MATERIALS FOR DAMAGE OR MISSING

PARTS. IF YOU DISCOVER DAMAGED OR MISSING

MATERIALS, IN THE USA PLEASE NOTIFY THE FACTORY

AT (800) 233-8493, AND IN CANADA (888) 895-8955 FOR

CUSTOMER SERVICE.

FLUSH MOUNTED CORNER GUARD MUST BE

INSTALLED IN ACCORDANCE WITH THESE

INSTRUCTIONS! FAILURE TO FOLLOW THESE

INSTRUCTIONS MAY VOID ANY PRODUCT WARRANTIES

AND RESULT IN AN UNSUCCESSFUL INSTALLATION.

FOR SPECIFIC QUESTIONS REGARDING THE

INSTALLATION OF THIS FLUSH MOUNTED CORNER

GUARD PLEASE CALL THE FACTORY IN THE USA AT

(800) 233-8493 OR EMAIL

[email protected]. IN CANADA CALL

(888) 895-8955.

G.W.B (BY OTHERS)

FEATHERED

JOINT CEMENT

LEG

LENGTH

LEG

LENGTH

R1/4"

[R6.3mm]

Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16

AutoCAD SHX Text
1
Page 2: FLUSH MOUNTED CORNER GUARDS · 2017-11-04 · flush mounted corner guards 24fmcg important notes 1. all material to be supplied in stock lengths. aluminum retainer and acrovyn covers

FS-20NFS-10N

FS-10MN

SFS-10N SFS-20N

FS-10N MOD

-RETAINER IS SPLIT FOR ANGLES LESS THAN 78°

OR GREATER THAN 154°

- RETAINER IS FACTORY MODIFIED FOR ALL OTHER

ANGLES (EXCLUDING 90°)

FLUSH MOUNTED CORNER GUARDS

SECTIONAL VIEW

24FMCG

G.W.B (BY OTHERS)

3"

[76.6mm]

3"

[76.6mm]

STEEL/WOOD STUD

(BY OTHERS)

2"

[51.2mm]

FOAM TAPE

2"

[51.2mm]

G.W.B.

(BY OTHERS)

135°

3"

[76.2mm]

3"

[76.2mm]

R1"

[R25.4mm]

R1/4"

[R6.4mm]

R1/4"

[R6.4mm]

R1 1/4"

[R31.8mm]

R1 1/4"

[R31.8mm]

R1 1/4"

[R31.8mm]

STEEL/WOOD

STUD (BY OTHERS)

G.W.B.

(BY OTHERS)

STEEL/WOOD

STUD (BY OTHERS)

G.W.B (BY OTHERS)

G.W.B (BY OTHERS)

G.W.B (BY OTHERS)

STEEL/WOOD STUD

(BY OTHERS)

STEEL/WOOD STUD

(BY OTHERS)

STEEL/WOOD STUD

(BY OTHERS)

Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16

AutoCAD SHX Text
2
Page 3: FLUSH MOUNTED CORNER GUARDS · 2017-11-04 · flush mounted corner guards 24fmcg important notes 1. all material to be supplied in stock lengths. aluminum retainer and acrovyn covers

FLUSH MOUNTED CORNER GUARDS

COMPONENTS & WALL FASTENERS

24FMCG

FS-10N/FS-10MN ACROVYN COVER

(24U130xxx)

ACROVYN CHAMELEON COVER

(24U963xxx)

FS-20N ACROVYN COVER

(24U002xxx)

ACROVYN CHAMELEON COVER

(24U634xxx)

FS-10N/FS-20N

ALUMINUM RETAINER

1/2" DRYWALL (24A159000)

5/8" DRYWALL (24A166000)

FS-10MN

ALUMINUM RETAINER

1/2" DRYWALL (24A162000)

5/8" DRYWALL (24A168000)

(SEE SECTION ON PAGE 2 IF WALL IS

AN ANGLE OTHER THAN 135°)

SFS-10N ACROVYN COVER

(24U007xxx)

ACROVYN CHAMELEON COVER

(24U676xxx)

SFS-20N ACROVYN COVER

(24U004xxx)

ACROVYN CHAMELEON COVER

(24U622xxx)

WALL CONDITION SPECIFIED FASTENER

DRILL DIAMETERS

CS PART

NUMBER

WALL RETAINER

STEEL STUD/GYPSUM WALL

WOOD STUD/GYPSUM WALL

#6 X 1 5/8" BUGLE HEAD SMS N/A N/A 90H079002

SFS-10N/SFS-20N

ALUMINUM RETAINER

1/2" DRYWALL (24A160000)

5/8" DRYWALL (24A167000)

4" ALUMINUM BASE

(24F008000-FS10N )

(24F010000-FS10MN)

(24F009000-FS20N)

(24F011000-SFS10N)

(24F012000-SFS20N)

1" ALUMINUM

CLOSURE CAP

(24F094000-FS10N)

(24F096000-FS10MN)

(24F062000-FS20N)

(24F093000-SFS10N)

(24F063000-SFS20N)

GASKET

(24M009000-FS10N)

(24M018000-FS10MN)

(24M010000-FS20N)

(24M011000-SFS10N)

(24M012000-SFS20N)

6" ALUMINUM BASE

(24F145000-FS10N)

(24F149000-FS10MN)

(24F146000-FS20N)

(24F147000-SFS10N)

(24F144000-SFS20N)

3/4" FOAM TAPE

**SFS-10N ONLY**

(90M008002C)

Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16

AutoCAD SHX Text
3
Page 4: FLUSH MOUNTED CORNER GUARDS · 2017-11-04 · flush mounted corner guards 24fmcg important notes 1. all material to be supplied in stock lengths. aluminum retainer and acrovyn covers

NOTE:

DUE TO THE NOSE RADIUS, IT IS NOT

RECOMMENDED TO INSTALL FS-10N, FS-10MN,

OR SFS-10N AT PARTIAL HEIGHT.

FULL HEIGHT PARTIAL HEIGHT

STANDARD DEDUCTIONS

FLUSH MOUNTED CORNER GUARDS

LAYOUT VIEW

24FMCG

RETAINER

LENGTH

EQUALS

CEILING

HEIGHT

PLUS 2"

[50.8mm]

2"

[50.8mm]

BASE

HEIGHT

1/16" [1.6mm]

GASKET

COVER

LENGTH

EQUALS

RETAINER

LENGTH

MINUS

BASE

HEIGHT

AND

1/16"

[1.6mm]

FINISH CEILING

ALUMINUM RETAINER

FINISH FLOOR

RETAINER

HEIGHT

EQUALS

FINISH

HEIGHT

PLUS

1" [25.4mm]

BASE

HEIGHT

1/16" [1.6mm]

GASKET

COVER

LENGTH

EQUALS

FINISH

HEIGHT

MINUS

BASE

HEIGHT

AND

1/8" [3.2mm]

1/16" [1.6mm]

GASKET

1"

[25.4mm]

ALUMINUM CLOSURE

CAP

ALUMINUM

RETAINER

CEILING

HEIGHT

Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16

AutoCAD SHX Text
4
Page 5: FLUSH MOUNTED CORNER GUARDS · 2017-11-04 · flush mounted corner guards 24fmcg important notes 1. all material to be supplied in stock lengths. aluminum retainer and acrovyn covers

FULL HEIGHT PARTIAL HEIGHT

FLUSH MOUNTED CORNER GUARDS

TYPICAL ASSEMBLY

24FMCG

DRYWALL SETBACK CHART

FS-10N FS-10MN FS-20N SFS-10N SFS-20N

1/2" DRYWALL

2 11/16"

[68.3mm]

2 13/16"

[71.4mm]

2 11/16"

[68.3mm]

1 3/4"

[43.8mm]

1 3/4"

[43.8mm]

5/8" DRYWALL

2 5/8"

[66.7mm]

2 13/16"

[71.4mm]

2 5/8"

[66.7mm]

1 5/8"

[41.3mm]

1 5/8"

[41.3mm]

DRYWALL/

PLASTER

STEEL/WOOD

STUD

DRYWALL SETBACK

(REF. CHART BELOW)

SPECIFIED FASTENER

PRE-PUNCHED

HOLES

18"

[457.2mm]

MAX.

ALUMINUM

RETAINER

BLACK

ACROVYN

GASKET

ALUMINUM BASE

ACROVYN

COVER

DRYWALL/

PLASTER

STEEL/WOOD

STUD

ALUMINUM CLOSURE CAP

REQUIRED AT PARTIAL

HEIGHT APPLICATIONS

BLACK ACROVYN

GASKET

18"

[457.2mm]

MAX.

SPECIFIED

FASTENER

PRE-PUNCHED

HOLES

ALUMINUM

RETAINER

ACROVYN

COVER

BLACK

ACROVYN

GASKET

ALUMINUM BASE

Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16

AutoCAD SHX Text
5
Page 6: FLUSH MOUNTED CORNER GUARDS · 2017-11-04 · flush mounted corner guards 24fmcg important notes 1. all material to be supplied in stock lengths. aluminum retainer and acrovyn covers

1. WHEN INSTALLING THE GYPSUM BOARD OR PLASTER, CONSULT

THE CHART ON PAGE 5 TO DETERMINE THE SETBACK DISTANCE

TO PROVIDE A SNUG FIT WHEN THE RETAINER IS INSTALLED.

NOTE: FOR ODD-ANGLE CONDITIONS DRY FIT ALUMINUM BASE WITH

ALUMINUM RETAINERS TO AID IN DETERMINING DRYWALL SETBACK

AND PROPERLY POSITION RETAINERS ON CORNER OF WALL. IF WALL

IS LESS THAN 78° OR GREATER THAN 154°, ALUMINUM RETAINERS ARE

SPLIT INTO (2) PIECES.

2. ALIGN EACH RETAINER WITH THE CORNER AND SECURE EACH

LEG THROUGH THE WALL INTO METAL/WOOD STUDS USING THE

SPECIFIED FASTENERS. MAKE SURE THE RETAINER REMAINS

PLUMB WITH THE FINISH FLOOR.

3. INSERT ALUMINUM BASE CLOSURE AT THE BASE OF THE

RETAINER AND SECURE THE ACROVYN GASKET ON TOP BY

REMOVING THE PROTECTIVE COVERING TO EXPOSE THE

TRANSFER ADHESIVE. ALIGN GASKET WITH OUTSIDE EDGE.

NOTE: GASKETS FOR FS-10N MOD CORNER GUARDS ARE TO BE FIELD

MITERED.

4. A 1" [25.4mm] CLOSURE CAP IS TO BE INSTALLED AT TOP OF

RETAINER ON PARTIAL HEIGHT GUARDS FOLLOWING

PROCEDURES SIMILAR TO STEP 3.

5. APPLY 2" [50.8mm] JOINT TAPE ALONG THE EDGE OF THE DRYWALL

AND THE ALUMINUM RETAINER WITH INTEGRATED CORNER BEAD.

FINISH THE INSTALLATION BY APPLYING A UNIFORM FEATHERED

JOINT AT THIS LOCATION AS PER STANDARD CONSTRUCTION

PRACTICES. ALLOW TO DRY AND THEN SAND AS REQUIRED.

APPLY ADDITIONAL COATS, AS REQUIRED, TO PROVIDE A

UNIFORM AND NEAT FINISH. APPLY THE PROCEDURE TO ANY

"CLOSURE" CAPS USED ON PARTIAL HEIGHT INSTALLATIONS.

6. FINISH WALL SURFACE AS SPECIFIED. BE SURE THAT THE

SELECTED FINISH IS APPLIED TO THE INSIDE SURFACE OF THE

REAR "CONTOURED" PORTION OF THE ALUMINUM RETAINER.

NOTE: ON MODEL SFS-10N: APPLY NEOPRENE TAPE TO NOSE OF THE

RETAINER.

7. FINISH INSTALLATION BY SNAPPING THE ACROVYN COVER ONTO

THE RETAINER.

FLUSH MOUNTED CORNER GUARDS

TYPICAL ASSEMBLY

24FMCG

This document is the property of Construction Specialties, Inc. and contains CONFIDENTIAL PROPRIETARY INFORMATION

that is not to be disclosed to third parties and is not to be used without approval in writing from Construction Specialties, Inc.

Muncy, Pennsylvania ● (800) 233-8493 ● Fax (570) 546-5169

Mississauga Ontario ● (888) 895-8955 ● Fax (905) 274-6241

www.c-sgroup.com

DRYWALL

TAPE

FEATHERED

JOINT

WALL FINISH

MATERIAL

COVE BASE

(BY OTHERS)

BLACK ACROVYN

GASKET

WALL

FINISH

MATERIAL

FEATHERED

JOINT

ACROVYN

COVER

DRYWALL

SETBACK

(REF. CHART

ON PAGE 5)

WALL FINISH

MATERIAL

Doc#: II-24FMCG Issue Date: 01/01/99 Rev Date: 10/12/16

AutoCAD SHX Text
6
AutoCAD SHX Text
10/12/16