focus photo fp64-sm1 - altalink · genesee 330p leduc pcounty ne-25-50-3- w5 ne-26-50-3- w5...

1
1209L 1203L GENESEE 330P LEDUC COUNTY NE-25-50-3- W5 NE-26-50-3- W5 NE-35-50-3- W5 NE-36-50-3- W5 NW-25-50-3- W5 NW-36-50-3- W5 SE-25-50-3- W5 SE-26-50-3- W5 SE-35-50-3- W5 SE-36-50-3- W5 SW-25-50-3- W5 SW-36-50-3- W5 C1 809L Photography dated: 2007 Source: Valtus Imagery Services 40cm Colour Ortho Photography Although there is no reason to believe that there are any errors associated with the data used to generate this product or in the product itself, users of these data are advised that errors in the data may be present. Indicative Tower Tangent Structure (0-1 degrees) Light Deadend Structure (0-45 degrees) Heavy Deadend Structure (45-90 degrees) Point Designation Preferred/Alternate Transmission Line Route Proposed Reconfiguration of Existing Transmission Line Salvaged Line Future Sunnybrook 510S Substation Proposed Sunnybrook 510S Substation Right of Way Boundary Existing Substation Gas or Oil Well Existing Transmission Line Road FP64-SM1 FOCUS PHOTO WESTERN ALBERTA TRANSMISSION LINE PROPOSED NO: DRAWN: CT - ST FILE NO.: 123510318-185 REVISION: 0.04.00 DATE: 2011-02-25 AL FOLDER: Western Alberta Transmission Line 0 200 400 Metres 0 500 1,000 Feet LEGEND Proposed 500kV AC Proposed 500kV AC Reconfigured Existing 500kV Sunnybrook Substation Reconfigured Existing 138kV

Upload: truongliem

Post on 27-Apr-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: FOCUS PHOTO FP64-SM1 - AltaLink · GENESEE 330P LEDUC PCOUNTY NE-25-50-3- W5 NE-26-50-3- W5 NE-35-50-3- W5 NE-36-50-3- W5 NW-25-50-3- W5 ... Sunnybrook Substation …

1209

L

1203

LGENESEE330P

LEDUC COUNTYNE-25-50-3- W5NE-26-50-3- W5

NE-35-50-3- W5 NE-36-50-3- W5

NW-25-50-3- W5

NW-36-50-3- W5

SE-25-50-3- W5SE-26-50-3- W5

SE-35-50-3- W5

SE-36-50-3- W5

SW-25-50-3- W5

SW-36-50-3- W5

C1 809L

Photography dated: 2007 Source: Valtus Imagery Services 40cm Colour Ortho PhotographyAlthough there is no reason to believe that there are any errors associated with the data used to generate thisproduct or in the product itself, users of these data are advised that errors in the data may be present.

Indicative TowerTangent Structure (0-1 degrees)Light Deadend Structure (0-45 degrees)Heavy Deadend Structure (45-90 degrees)Point DesignationPreferred/Alternate Transmission Line RouteProposed Reconfiguration of Existing Transmission Line

Salvaged LineFuture Sunnybrook 510S Substation Proposed Sunnybrook 510S SubstationRight of Way BoundaryExisting SubstationGas or Oil WellExisting Transmission LineRoad

FP64-SM1FOCUS PHOTO

WESTERN ALBERTA TRANSMISSION LINEPROPOSED

NO: DRAWN: CT - STFILE NO.: 123510318-185REVISION: 0.04.00DATE: 2011-02-25AL FOLDER: Western Alberta Transmission Line

0 200 400 Metres

0 500 1,000 Feet

LEGEND

Proposed 500kV AC

Proposed 500kV AC

Reco

nfigu

red Ex

isting

500k

V

Sunnybrook Substation

Reco

nfigu

red Ex

isting

138k

V