FPR Lessons Learned Sterling Field Support Center. December 1, 2009. Contact Center Inquiries. 39 trouble tickets since June Of the 39 tickets, 8 kits were returned to Kansas City. Contact Center Inquiries. 39 trouble tickets since June Of the 39 tickets, 8 kits were returned to Kansas City - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/1.jpg)
FPR Lessons LearnedFPR Lessons LearnedSterling Field Support CenterSterling Field Support Center
December 1, 2009December 1, 2009
![Page 2: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/2.jpg)
Contact Center InquiriesContact Center Inquiries
•39 trouble tickets since June39 trouble tickets since June– Of the 39 tickets, 8 kits were Of the 39 tickets, 8 kits were
returned to Kansas Cityreturned to Kansas City
![Page 3: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/3.jpg)
Contact Center InquiriesContact Center Inquiries
•39 trouble tickets since June39 trouble tickets since June– Of the 39 tickets, 8 kits were Of the 39 tickets, 8 kits were
returned to Kansas Cityreturned to Kansas City
•Circuit card/display needed to be Circuit card/display needed to be reseatedreseated
![Page 4: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/4.jpg)
Contact Center InquiriesContact Center Inquiries
•39 trouble tickets since June39 trouble tickets since June– Of the 39 tickets, 8 kits were Of the 39 tickets, 8 kits were
returned to Kansas Cityreturned to Kansas City
•Circuit card/display needed to be Circuit card/display needed to be reseatedreseated
•Defective switchDefective switch
![Page 5: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/5.jpg)
Contact Center InquiriesContact Center Inquiries
![Page 6: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/6.jpg)
Contact Center InquiriesContact Center Inquiries
•Several tickets related to the Several tickets related to the assembly instructionsassembly instructions
•Feedback from the field resulted Feedback from the field resulted in many early changes to the in many early changes to the instructionsinstructions
![Page 7: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/7.jpg)
Contact Center InquiriesContact Center Inquiries
•Categories:Categories:
– SettingsSettings– InstallationInstallation– Error CodesError Codes– Data IssuesData Issues– Logger IssuesLogger Issues
![Page 8: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/8.jpg)
Common IssuesCommon Issues
•SettingsSettings– Does the Site ID need to be 8 digitsDoes the Site ID need to be 8 digits
??
![Page 9: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/9.jpg)
Common IssuesCommon Issues
•SettingsSettings– Does the Site ID need to be 8 digitsDoes the Site ID need to be 8 digits
??•YES, the Site ID MUST be 8 digits. The YES, the Site ID MUST be 8 digits. The
third and fourth digits will be zerosthird and fourth digits will be zeros
![Page 10: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/10.jpg)
Common IssuesCommon Issues
•SettingsSettings– Does the Site ID need to be 8 digitsDoes the Site ID need to be 8 digits
??•YES, the Site ID MUST be 8 digits. The YES, the Site ID MUST be 8 digits. The
third and fourth digits will be zerosthird and fourth digits will be zeros
– Does the data logger lose settings Does the data logger lose settings when the battery is disconnected?when the battery is disconnected?
![Page 11: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/11.jpg)
Common IssuesCommon Issues
•SettingsSettings– Does the Site ID need to be 8 digitsDoes the Site ID need to be 8 digits ??
•YES, the Site ID MUST be 8 digits. The YES, the Site ID MUST be 8 digits. The third and fourth digits will be zerosthird and fourth digits will be zeros
– Does the data logger lose settings Does the data logger lose settings when the battery is disconnected?when the battery is disconnected?•NO, the settings are saved to memory NO, the settings are saved to memory
![Page 12: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/12.jpg)
Common IssuesCommon Issues
• InstallationInstallation– Which way should the load cell be Which way should the load cell be
installed?installed?
![Page 13: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/13.jpg)
Common IssuesCommon Issues
• InstallationInstallation– Which way should the load cell be Which way should the load cell be
installed?installed?•It can be installed either parallel or It can be installed either parallel or
perpendicular to the baseperpendicular to the base
![Page 14: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/14.jpg)
Common IssuesCommon Issues
• InstallationInstallation– Which way should the load cell be Which way should the load cell be
installed?installed?•It can be installed either parallel or It can be installed either parallel or
perpendicular to the baseperpendicular to the base
– Does the load cell require locking Does the load cell require locking washers?washers?
![Page 15: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/15.jpg)
Common IssuesCommon Issues
• InstallationInstallation– Which way should the load cell be Which way should the load cell be
installed?installed?•It can be installed either parallel or It can be installed either parallel or
perpendicular to the baseperpendicular to the base
– Does the load cell require locking Does the load cell require locking washers?washers?•No, it does notNo, it does not
![Page 16: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/16.jpg)
Common IssuesCommon Issues
•Error CodesError Codes– What is a hardware error #4207?What is a hardware error #4207?
![Page 17: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/17.jpg)
Common IssuesCommon Issues
•Error CodesError Codes– What is a hardware error #4207?What is a hardware error #4207?
•This occurs when the SD card is This occurs when the SD card is removed incorrectly after removed incorrectly after downloading datadownloading data
![Page 18: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/18.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– The data shows large swings in The data shows large swings in
data?data?
![Page 19: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/19.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– The data shows large swings in The data shows large swings in
data?data?•Check the base itself: flexors, plunger Check the base itself: flexors, plunger
position, calibration, post not touching position, calibration, post not touching lower assemblylower assembly
![Page 20: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/20.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– The data shows large swings in The data shows large swings in
data?data?•Check the base itself: flexors, plunger Check the base itself: flexors, plunger
position, calibration, post not touching position, calibration, post not touching lower assemblylower assembly
– Bent flexorsBent flexors
![Page 21: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/21.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– The data shows large swings in The data shows large swings in
data?data?•Check the base itself: flexors, plunger Check the base itself: flexors, plunger
position, calibration, post not touching position, calibration, post not touching lower assemblylower assembly
– Bent flexorsBent flexors– Uneven baseUneven base
![Page 22: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/22.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– The data shows large swings in The data shows large swings in
data?data?•Check the base itself: flexors, plunger Check the base itself: flexors, plunger
position, calibration, post not touching position, calibration, post not touching lower assemblylower assembly
– Bent flexorsBent flexors– Uneven baseUneven base– RecalibrationRecalibration
![Page 23: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/23.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– Data lost because of power resets?Data lost because of power resets?
![Page 24: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/24.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– Data lost because of power resets?Data lost because of power resets?
•Check the connections, wires, cables, Check the connections, wires, cables, terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagram, blockage on the solar wiring diagram, blockage on the solar panelpanel
![Page 25: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/25.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– Data lost because of power resets?Data lost because of power resets?
•Check the connections, wires, cables, Check the connections, wires, cables, terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagram, blockage on the solar wiring diagram, blockage on the solar panelpanel
– Connection at the terminal was looseConnection at the terminal was loose
![Page 26: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/26.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– Data lost because of power resets?Data lost because of power resets?
•Check the connections, wires, cables, Check the connections, wires, cables, terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagram, blockage on the solar wiring diagram, blockage on the solar panelpanel
– Connection at the terminal was looseConnection at the terminal was loose– Bad batteryBad battery
![Page 27: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/27.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– Data lost because of power resets?Data lost because of power resets?
•Check the connections, wires, cables, Check the connections, wires, cables, terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagram, blockage on the solar wiring diagram, blockage on the solar panelpanel
– Connection at the terminal was looseConnection at the terminal was loose– Bad batteryBad battery– Loose battery cableLoose battery cable
![Page 28: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/28.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– Data are showing Data are showing
decreases/increasesdecreases/increases??
![Page 29: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/29.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– Data are showing Data are showing
decreases/increasesdecreases/increases??
•Check the oil levelCheck the oil level
![Page 30: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/30.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– Data are showing Data are showing
decreases/increasesdecreases/increases??
•Check the oil levelCheck the oil level– No oil therefore precipitation was No oil therefore precipitation was
evaporating evaporating
![Page 31: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/31.jpg)
Common IssuesCommon Issues
•Data IssuesData Issues– Data are showing Data are showing
decreases/increasesdecreases/increases??
•Check the oil levelCheck the oil level– No oil therefore precipitation was No oil therefore precipitation was
evaporating evaporating – No oil with the antifreeze therefore No oil with the antifreeze therefore
moisture was being absorbed from the moisture was being absorbed from the atmosphereatmosphere
![Page 32: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/32.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– The logger would not wake up and The logger would not wake up and
a red status light was flashing?a red status light was flashing?
![Page 33: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/33.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– The logger would not wake up and The logger would not wake up and
a red status light was flashing?a red status light was flashing?•Check the connections, wires, cables, Check the connections, wires, cables,
terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagram, solar panelwiring diagram, solar panel
![Page 34: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/34.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– The logger would not wake up and The logger would not wake up and
a red status light was flashing?a red status light was flashing?•Check the connections, wires, cables, Check the connections, wires, cables,
terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagram, solar panelwiring diagram, solar panel
– Solar panel was crackedSolar panel was cracked
![Page 35: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/35.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– The logger would not wake up and The logger would not wake up and
a red status light was flashing?a red status light was flashing?•Check the connections, wires, cables, Check the connections, wires, cables,
terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagram, solar panelwiring diagram, solar panel
– Solar panel was crackedSolar panel was cracked– Bad grounding wireBad grounding wire
![Page 36: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/36.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– The logger locked up?The logger locked up?
![Page 37: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/37.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– The logger locked up?The logger locked up?
•Check the connections, wires, cables, Check the connections, wires, cables, terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagramwiring diagram
![Page 38: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/38.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– The logger locked up?The logger locked up?
•Check the connections, wires, cables, Check the connections, wires, cables, terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagramwiring diagram
– Circuit card/display had to be reseatedCircuit card/display had to be reseated
![Page 39: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/39.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– The logger was unable to be The logger was unable to be
programmed?programmed?
![Page 40: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/40.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– The logger was unable to be The logger was unable to be
programmed?programmed?•Check the connections, wires, cables, Check the connections, wires, cables,
terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagramwiring diagram
![Page 41: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/41.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– The logger was unable to be The logger was unable to be
programmed?programmed?•Check the connections, wires, cables, Check the connections, wires, cables,
terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagramwiring diagram
– Defective switchDefective switch
![Page 42: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/42.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– Display was coming on by itself?Display was coming on by itself?
![Page 43: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/43.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– Display was coming on by itself?Display was coming on by itself?
•Check the connections, wires, cables, Check the connections, wires, cables, terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagramwiring diagram
![Page 44: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/44.jpg)
Common IssuesCommon Issues
•Logger IssuesLogger Issues– Display was coming on by itself?Display was coming on by itself?
•Check the connections, wires, cables, Check the connections, wires, cables, terminal strip, voltage on the battery, terminal strip, voltage on the battery, wiring diagramwiring diagram
– One wire at the terminal strip was looseOne wire at the terminal strip was loose
![Page 45: FPR Lessons Learned Sterling Field Support Center](https://reader035.vdocument.in/reader035/viewer/2022070402/5681386c550346895da01e1e/html5/thumbnails/45.jpg)
Contact InformationContact Information
SFSC Contact CenterSFSC Contact Center
Monday – Friday Monday – Friday
8AM-5PM Eastern Time8AM-5PM Eastern Time
(703) 661-1268 Main Line(703) 661-1268 Main Line
(703) 661-1293 Backup Line(703) 661-1293 Backup Line
[email protected]@noaa.gov