fsmf
TRANSCRIPT
-
238 DN09108269
LTE RL40, Feature Descriptions and Instructions
Id:0900d80580994cddConfidential
5.4 LTE947: FSMF Flexi Multiradio 10 System ModuleIntroduction to the featureFlexi Multiradio BTS System Module FSMF is a highly integrated 3U high outdoor System Module of the Flexi Multiradio BTS. It hosts the telecom control, system opera-tion and maintenance, baseband application, transmission, and power distribution func-tionality. The System Module can be also equipped with optional capacity extension sub-modules which bring additional signal processing power and/or allow the system to support different radio access technology. Adding the capacity sub-modules in the field does not affect ongoing traffic.
The System Module can also act as a System Extension Module operating in a baseband extension mode. Flexi Multiradio BTS architecture supports chaining up to nine System Modules enabling to build very high capacity sites and different redundancy solutions.
Flexi Multiradio System Module hardware supports the following software operating modes:
GSM/EDGE mode WCDMA mode LTE in FDD and TDD mode
5.4.1 Benefits
End-user benefitsThis feature does not affect the end-user experience.
Operator benefitsThe FSMF is a successor of the FSMD and FSME System Modules providing enhanced capacity, connectivity and expansion possibilities in the same form factor. FSMF is IP ingress protected and operates at the temperature range from -35 to + 55 C.
5.4.2 Requirements
Software requirementsTable Software requirements lists software required for this feature.
System release Flexi Multiradio BTS Flexi Multiradio 10 BTS OMS
RL40 - LBTS4.0 OMS4.0
UE NetAct MME SAE GW
- OSS5.4 CD2 - -
Table Software requirements
-
DN09108269 239
LTE RL40, Feature Descriptions and Instructions
Id:0900d80580994cddConfidential
5.4.3 Functional description
Functional overviewThe Flexi Multiradio BTS System Module FSMF consists of a 3U high casing, which can accommodate in addition to the base module, optionally
up to two baseband sub-modules (FBBA), one additional transport sub-module (FTxx), one power distribution sub-module (FPFx).The following functions are integrated in the FSMF:
ethernet transport, clock and control functions, baseband processing, fan control, status LEDs.Table Flexi Multiradio System Module FSMF peak throughput shows the total through-put of a Flexi Multiradio System Module, which can vary depending on the combination of the modules used. Note that MIMO is supported for both HSPA and LTE.
One FSMF System Module provides a hardware baseband capacity for up to three 20 MHz LTE cells.
Figure 29 presents the front view of the Flexi Multiradio BTS System Module FSMF.
Capacity FSMF
GSM/EDGE
[transceivers]
72
WCDMA
[channel elements]
528
HSDPA
[Mbps]
756
HSUPA
[Mbps]
115
LTE DL
[Mbps]
450
LTE UL
[Mbps]
150
LTE BW/cell
[MHz]
20
LTE cells
[cell count]
3
MIMO (HSPA/LTE) yes
Table Flexi Multiradio System Module FSMF peak throughput
-
240 DN09108269
LTE RL40, Feature Descriptions and Instructions
Id:0900d80580994cddConfidential
Figure 29 Front panel of the System Module (FSMF) with optional sub-modules FPFD, FTIF, and two FBBAs
InterfacesThe FSMF provides the following interfaces:
Three optical OBSAI RP3-01 interfaces with up to 6 GBit/s or CPRI One optical interface which can be used as OBSAI RP3-01 interface with up to 6
Gbit/s (or CPRI) or as 1000Base-X as network interface One electrical interface 100/1000Base-T as transport backhaul interface One electrical interface 10/100Base-T as local management interface One Sync In interface One Sync Out interface One EAC (External Alarm and Control) interface (6 alarm signals, 6 SW-controllable
signals that can be assigned to be either Alarm or Control signals). The interface includes also a CAN interface.
One SRIO (Serial Rapid Input/Output) interface for an external baseband extension, for example additional System Module
Two baseband extension interfaces for optional sub-modules One -48 VDC input and one -48 VDC output
More information, see Flexi Multiradio 10 BTS, Multiradio System Module Description.
5.4.4 System impacts
Interdependencies between featuresThere are no interdependencies between this and any other feature.
-
DN09108269 241
LTE RL40, Feature Descriptions and Instructions
Id:0900d80580994cddConfidential
Impacts on interfacesNew interfaces available.
Impacts on network and network element management toolsThis feature has no impact on network management and network element management tools.
Impacts on system performance and capacityNew configurations are available.
5.4.5 LTE947:Flexi Multimode System Module FSMF management dataFor information on alarm, counter, key performance indicator, and parameter docu-ments, see Reference documentation.
AlarmsThere are no alarms related to this feature.
Measurements and countersThere are no measurements or counters related to this feature.
Key performance indicatorsThere are no key performance indicators related to this feature.
ParametersThere are no parameters related to this feature.
5.4.6 Sales information
BSW/ASW License control in network element License control attributes
BSW - -
Table Sales information
-
242 DN09108269
LTE RL40, Feature Descriptions and Instructions
Id:0900d805809953daConfidential
5.5 LTE949: FPFD Flexi Power Distribution Sub-moduleIntroduction to the featureThe FPFD is a highly integrated optional power distribution sub-module for the new Flexi Multiradio System Modules.
5.5.1 Benefits
End-user benefitsThis feature does not affect the end-user experience.
Operator benefitsOutdoor Power distribution unit with fuses is integrated into the 3U high System Module casing. The FPFD is installed into the Flexi Multiradio System Module and requires therefore no dedicated power distribution unit thus no need for additional space or cabinet.
5.5.2 Requirements
Software requirementsTable Software requirements lists software required for this feature.
Hardware requirementsThis feature requires Flexi Multiradio 10 BTS.
5.5.3 Functional description
Functional overviewOptional integrated FPFD outdoor sub-module is a size optimized power distribution unit (PDU). It is located at the top left of the outdoor Flexi Multiradio System Module.
It can be used for stacked configuration and feederless configuration the same way as earlier Flexi integrated Power distribution units. In feederless configuration FPFD can be used with optional Over Voltage Protection units (OVP with FSEC or FSES).
It can be installed together with new Flexi Multiradio System Module in one 3U casing. FPFD Power distribution sub-module provides four external -48 V DC outlets for Flexi Modules (RF Module, RRH, or external System Module) or any standard 48 V DC device at site and one internal DC output to System Module itself.
System release Flexi Multiradio BTS Flexi Multiradio 10 BTS OMS
- - - -
UE NetAct MME SAE GW
- - - -
Table Software requirements
-
DN09108269 243
LTE RL40, Feature Descriptions and Instructions
Id:0900d805809953daConfidential
The FPFD has integrated basic Over Voltage Protection on input (OVP Type approval level with +/- 1 kV (L-L) 8/20 s and +/- 2 kV (L-N) 8/20 s), EMC filtering and reverse polarity protection. It protects the connected units against short circuit, overcurrent (fixed trip points), and high voltage transients.
Figure 30 FPFD sub-module
InterfacesThe FPFD provides the following external interfaces:
One -48 V DC input Four external -48 V DC outputs One internal DC output to the System Module Control panel with the following elements:
one LED for each output (RF1, RF2, RF3, EXT, SYS) SELECT and SET buttons to control their status
Communication with Flexi Multiradio System Module is done via serial interface.
For more information, see:
Installing Flexi Multiradio 10 BTS Power Distribution Sub-Module (FPFD) in Install-ing Flexi Multiradio 10 BTS for Stack, Wall, and Pole Configurations.
Connecting Flexi Multiradio 10 BTS Power Distribution Sub-Module (FPFD) cabling in Cabling Flexi Multiradio 10 BTS.
5.5.4 System impacts
Interdependencies between featuresThere are no interdependencies between this and any other feature.
Impacts on interfacesNew interfaces available.
-
244 DN09108269
LTE RL40, Feature Descriptions and Instructions
Id:0900d805809953daConfidential
Impacts on network and network element management toolsThis feature has no impact on network management and network element management tools.
Impacts on system performance and capacityNew configurations are available.
5.5.5 LTE949: Flexi power distribution sub-module FPFD management dataFor information on alarm, counter, key performance indicator, and parameter docu-ments, see Reference documentation.
AlarmsThere are no alarms related to this feature.
Measurements and countersThere are no measurements or counters related to this feature.
Key performance indicatorsThere are no key performance indicators related to this feature.
ParametersThere are no parameters related to this feature.
5.5.6 Sales information
BSW/ASW License control in network element License control attributes
BSW - -
Table Sales information
-
DN09108269 245
LTE RL40, Feature Descriptions and Instructions
Id:0900d80580996cc4Confidential
5.6 LTE950: FPFC Flexi Power Distribution ModuleIntroduction to the featureThe optional FPFC is a stand-alone 19 inch rack wide power distribution module for Flexi Multiradio BTS configurations.
5.6.1 Benefits
End-user benefitsThis feature does not affect the end-user experience.
Operator benefitsThe general-purpose FPFC can be flexibly used at larger outdoor and indoor Flexi BTS sites, or up on a tower, together with Radio Modules or RRHs. It provides six -48V DC outputs with improved Over Voltage Protection (OVP).
5.6.2 Requirements
Software requirementsTable Software requirements lists software required for this feature.
Hardware requirementsThis feature requires no new or additional hardware.
5.6.3 Functional description
Functional overviewOptional FPFC is a stand-alone outdoor general purpose Power Distribution Unit (PDU) with Class II Over Voltage Protection, with 15 kA protection level. External overvoltage protection (using, for instance, units of type FSEC or FSES) might be needed with RF parts if the PDU is located more than ten meters away from the powered unit.
FPFC is a stand-alone external 19 inch wide 2U high outdoor module. Power distribution module FPFC provides six outlets for Flexi Modules (Radio Modules, RRHs, or System Module), or any standard -48 V DC device at site. It can also be used, for example, at the top of the antenna mast to distribute power to several RF Modules or Remote Radio Heads. It has one External alarm to indicate Over Voltage Protection (OVP) device con-dition.
System release Flexi Multiradio BTS Flexi Multiradio 10 BTS OMS
- - - -
UE NetAct MME SAE GW
- - - -
Table Software requirements
-
246 DN09108269
LTE RL40, Feature Descriptions and Instructions
Id:0900d80580996cc4Confidential
To provide more than six outputs, it is possible to chain two FPFCs using the same DC power source.
Figure 31 FPFC module
InterfacesFPFC provides the following external interfaces:
one DC input six DC outputs
CH1-2: maximum fixed output 30A CH3-6: maximum adjustable output 4A/15A/30AAdditionally, each output has On/Off bar.
one EAC connectorEAC connector (RJ45) informs about any abnormal situation, for example, when the protective component(s) have been damaged. It indicates SPD alarm via two alarm signals - Normal Open (NO) and Normal Closed (NC): NO
Alarm is active when the connection is closed. 5V alarm detection line is pulled down during alarm: Active = 0, Inactive = 1.
NCAlarm is active when the connection is open. 5V alarm detection line is pulled up during alarm: Active = 1, Inactive = 0.
For more information, see
Flexi Power Distribution and Fuses Outdoor (FPFC) description in Flexi Multiradio BTS LTE Optional Items Description
Installing Flexi Power Distribution and Fuses Outdoor (FPFC) in Installing Flexi Mul-tiradio BTS LTE Optional Items
FPFC EAC connector On/Off Bar
Input connectorIP boot
Input connector Output connectorIP boot
-
DN09108269 247
LTE RL40, Feature Descriptions and Instructions
Id:0900d80580996cc4Confidential
5.6.4 System impacts
Interdependencies between featuresThere are no interdependencies between this and any other feature.
Impacts on interfacesNew interfaces available.
Impacts on network and network element management toolsThis feature has no impact on network management and network element management tools.
Impacts on system performance and capacityNew configurations are available.
5.6.5 LTE950: Flexi power distribution module FPFC management dataFor information on alarm, counter, key performance indicator, and parameter docu-ments, see Reference documentation.
AlarmsThere are no alarms related to this feature.
Measurements and countersThere are no measurements or counters related to this feature.
Key performance indicatorsThere are no key performance indicators related to this feature.
ParametersThere are no parameters related to this feature.
5.6.6 Sales information
BSW/ASW License control in network element License control attributes
BSW - -
Table Sales information