gallerie e tunnel - select light · 5 gallerie e tunnel image 3 image 4 sibilities of energy saving...
TRANSCRIPT
1
GALLERIE E TUNNEL
FAEBER LIGHTING SYSTEM S.p.A.Via Papa Giovanni XXIII21040 Uboldo (VA) Italy
Telefono 39 02 96787811Telefax 39 02 96788846
www.faeber.it - [email protected]
LE
D
CA
TA
LO
GU
E
Palacio Guanabara rio de Janeiro brasile - liGhtinG ProJect Milton GiGlio atelier da luz
4
image 1
image 2
HISTORY AND EVOLUTION
LED is the acronym of Light Emitting Dio-
de. The first LED was developed in 1962 in
the USA by Nick Holonyak Jr.
Initially LED were available with only one
monochromatic emission of about 700
nanometres of wave length, meaning of
red colour. Even having a high luminous
efficiency they could be used mainly just
as signals but not for general lighting.
In the following years yellow and gre-
en LED were developed but still were
excluded for use in the world of lighting.
Only in the ninety’s, finally, LED with a hi-
gher efficiency and greater colour range
were created until also blue colour was
possible and enabled the mixture of
light: one red, one green and one blue
LED resulting in white colour. The subse-
quent development resulted in the use
of LED emitting specific wave lengths by
means (image 1-2) of exciting a layer of
phosphor and letting it light with high
efficiency. The light had a wide spectrum
and therefore different shades of white
also considered as colour temperatures
– Kelvin. This represents the biggest re-
volution in the lighting world of the last
years introducing dynamics previously
related to electronics and giving plan-
ners a wide range of solutions and pos-
Phosphor Layer
Cathode
TVS
LED Chip
Bond Layer
Metal Interconnect Layer
Silicone Lens
Ceramic Substrate
Thermal Pad
5
GALLERIE E TUNNEL
image 3
image 4
sibilities of energy saving which up to
then were unthinkable.
The LED technology reached in the last
years a drastically increase of efficiency
(lm/W) allowing the use of these com-
ponents in general lighting represen-
ting a valid alternative to traditional light
sources such as sodium high pressure
and metal halide discharge and fluore-
scent lamps.
In respect to these light sources LED
offers:
1- High efficiency in continuous growth,
at present LED are available with 160
lm/W and it seems possible to reach 200
lm/W in future (image 3).
2- High colour rendering CRI 70-90
3- Long lifetime > 50.000 h
4- Instant ignition
5- Excellent functioning also at very low
temperature (-25°C)
6- Tiny dimensions allowing the creation
of items with the most variable forms and
dimensions (image 4).
7- Good resistance to vibrations allowing
the use in harsh environments
8- Absence of infrared radiation emis-
sions andvery low UV radiation emission.
9- Absence of mercury
Cathode
TVS
Edison bulbs
fluorescent tubes
current industrial target
Nichia
Luminous efficiency of white LED
Lum
inou
s ef
ficie
ncy
(lum
en/w
att)
Preview of the English Department for Trade and Industry
Mejio Univ.
Cree
160
140
120
100
80
60
40
20
0
1990 1995 2000 2005 2010 2015
6
image 5
WHITE LIGHT
To generate white light normally one or
more blue LED are used which excite a la-
yer of phosphor which emits white light.
This light has the following characteri-
stics:
a) Colour temperature:
It is the temperature a black body should
have when the luminous radiation emit-
ted by itself appears chromatically as clo-
se as possible to the considered radiation
of the light to measure.
A low temperature (e.g. 2000°K) corre-
sponds to a yellow-orange colour. Even
lower one passes to red and to infrared,
which one can’t see anymore, whereas by
rising the temperature the light becomes
first white, then blue, violet and finally ul-
traviolet. If commonly said a light is warm
it is in reality corresponding to a low co-
lour temperature and vice versa a higher
temperature results in a commonly defi-
ned cool light.
These definitions are simply psycholo-
gically based since our mind associates
to colours like yellow-orange the idea of
heat and to colours like white and blue
coldness.
1800K 4000K 5500K 8000K 12000K 16000K
7
To notice that to talk about colour tempe-
rature makes only sense if the light source
emits a continuous energy spectrum.
This does not happen to all light sources.
Chromatic zones (BIN) (image 6): the LED
production is divided into areas defining
the chromatic coordinates.
These are so called BIN. Deliveries are
subject to a certain BIN number; the lo-
wer the number the better colour unifor-
mity.
FAEBER decided to use batches of low BIN
number even if it might result in a higher
price.
b) Colour Rendering Index (CRI):
This is the ability of a light source to di-
stinguish colours of a total sample refe-
rence (generally 8).
The norm UNI 10380 splits the different
values of the chromatic rendering index
in five groups:
• 1A: 90%
• 1B: 80% 90%
• 2: 60% 80%
• 3: 40% 60%
• 4: 20% 40%
image 6
8
The norm also suggests which CRI to be
used according to
the place to illuminated:
• 1A: housing, museums, graphic studios,
hospitals, medical cabinet, etc.
• 1B: offices, schools, shops, gyms, thea-
tres, textile and colour production, etc.
• 2: passage rooms, corridors, staircases,
elevators, gyms, service areas, etc.
• 3: indoor industrial, offices, warehouses
etc.
• 4: parking lots, piers, construction area,
loading areas etc.
Cold light LED generally have a CRI of 70-
75 whereas warm light ones of 75-80 and
sometimes over 90.
INTERNATIONAL CODES FOR COLOUR
TEMPERATURE:
At an International level a light source can
be defined with a 3 digit code.
The first digit is the chromatic rendering:
9 = Ra 90÷100
8 = Ra 80÷90
7 = Ra 70÷80
6 = Ra 60÷69
9
image 7
The second and third digit is the colour
temperature:
27 = 2700 K
30 = 3000 K
40 = 4000 K
65 = 6500 K
E.g.: /830 defines a light source with chro-
matic index of 80-90 and a colour tempe-
rature of 3000°K.
COLOURED LED
By pondered mixing of light sources ha-
ving the 3 primary colours red, green and
blue (RGB) it is possible to obtain all iris
colours (image 7).
The chromatic diagram CIE defines a co-
lour area which includes all colours visi-
ble to the human eye, independent of
the luminance. To obtain all colours light
fixtures are equipped with primary co-
lours LED and dimmable drivers run with
different protocols among which DMX
is the most common.
FAEBER LIGHTING SYSTEM supplies on de-
mand Fixtures and necessary interfaces
to generate and manage these signals.
Spectrum Locus
Planchian Locus
Illuminant A
D65
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
520
500
490
480
470
540
560
580
600
620
700
380460
00
70000
6000
Te (°K)4000
3000
2000 1500
y
CIE 1931 xy Chromaticity Diagram
Obtainable cOlOurs with multichip leD by means Of pOnDereD mix sO tO reprODuce all cOlOurs insiDe the pOlygOne having as verticals the cOOrDinates Of each leD
10
LED LIFETIME
LED are electronic components having a
long but not Infinite lifetime. Generally
LED do not “die” and switch off but pro-
gressively lower the light values to a not
acceptable level.
The presumed lifetime of an LED is con-
sidered by the number of hours within a
certain percentage of samples presents a
percentage of higher flux compared to a
fraction of the initial flux.
E.g. 50.000h L70B10 means that after
50.000h at least 90% of the LED Still
have a flux of 70% compared to the ini-
tial flux.
HEAT MANAGEMENT
Different factors influence the life of an
LED (image 8) but the one in particular is
the junction temperature (Tj) which is sup-
posed to be the lowest possible (image 9).
LED manufacturers submit lists indicating
the presumed lifetime based on this tem-
perature.
To guarantee a long lifetime of the pro-
duct it is therefore essential for the de-
sign to use technical devices (radiators,
thermal interfaces etc) aimed to dissipate
the produced heat correctly.
Being conscious about this, FAEBER desi-
gns its fixtures so to ensure the tempera-
tures are far below the recommended
maximums.
image 8
image 9
TJ = TA + (Rth J-A x Pd)
Rth J-C
Rth C-P
Rth P-A
Tjunction
Tcase
Tplate
Tambient
Component
SubstrateTechnology
Cooling System
100k
80k
60k
40k
20k
0
60 80 100 120
“LED LIFE”
Star limits
Temperature
0.1 A
0.35 A
0.7 A
1 A
11
image 10
POWER SUPPLY
Another very important aspect to achie-
ve an efficient, save and long lasting pro-
duct relies on the choice of a correct dri-
ver which has to supply over the whole
lifetime of the LED the right current.
To maximize energy saving, it is also pos-
sible to use dimmable drivers which re-
duce the emitted light when full emission
is not needed so to lower the absorbed
power.
This is very important in management of
street and tunnel lighting.
The most diffused dimming protocols
are with bus 1-10V, PWM or DALI. Items
equipped with dimmable drivers can be
integrated in installations managed by
remote serial signals (RS485), power line
signals or radio signals by using appro-
priate interfaces.
FAEBER has chosen to use SELV drivers
(extreme low security voltage) as to en-
sure maximum security also during main-
tenance of the fittings.
LED FIXTURES AND STREET LIGHTING
Street lighting is one of the fields where
LED fixtures show all their advantages
compared to items with discharge lamps.
This is due further to the already mentio-
ned high efficiency and versatility of LED
to the following aspects:
Photopic v (l) and scotopic v2 (l) human response curve1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
400 450 500 550 600 650 700 750wavelength (nm)
Rel
ativ
e re
spo
nse
Visual acuity curves for photopicand scotopic vision.
CIE 1924 photopic v (l)
CIE 1951 scotopic v2 (l)
Phosphor Layer
Cathode
TVS
LED Chip
Bond Layer
Metal Interconnect Layer
Silicone Lens
Ceramic Substrate
Thermal Pad
12
image 11
image 12
image 13
1) High chromatic rendering with spec-
trum leading towards the blue zone. In
fact during night vison (scotopic) the sen-
sibility of the human eye tends towards
frequencies near to blue (image 10).
To obtain the same visual effect of a so-
dium high pressure lamp by using an LED
less light and therefore energy is used.
The Italian norm UNI 11248 takes this
scientific phenomena into consideration
and allows to declass by one category
if light sources with a CRI > 60 are used.
E.g. if a street taken into consideration is
classified ME3a it can be classified ME4a if
these light sources are used.
The norm UNI-EN13201 demands for
a correct illumination of ME3a streets
1.0cd/m2 and 0.75 cd/m2 for a ME4a, so
25% less light (image 11).
2) Possibility to obtain a great number of
different photometries which can be ap-
plied to all type of streets (image 12).
This allows to direct all the light on the
street itself and to avoid dispensations im-
proving the coefficient of use (image 13).
The amount of light emitted towards the
external area of the carriage way (the red
traced area) is clearly lower when good
LED are used (b) in respect of the same
emission in that area when traditional
lights are used (a).
AFFECTING PARAMTERS CATEGoRy ChANGE
normal visual TasK -1
non conflicTual -1
Traffic flux minor of 50% To maximum -1
Traffic flux minor of 25% To maximum -2
evidenT signs in conflicTual areas -1
wiTh cri ≥ 60 iT’s possible To reduce one caTegory -1
wiTh cri ≤ 30 iT’s necessary To increase by one caTegory +1
danger of aTTacK +1
presence of same level inTerchange and/or inTersecTion +1
200
200
400
600
800
1000
200
200
400
600
800
10000˚0˚ 15˚15˚ 15˚15˚ 30˚30˚ 30˚30˚
45˚45˚ 45˚45˚
60˚60˚ 60˚60˚
75˚75˚ 75˚75˚
90˚90˚ 90˚90˚
105˚105˚ 105˚105˚
120˚120˚ 180˚180˚
cd/kl cd/kl m m
200
200
400
600
800
10000˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
Gamma Angle Gamma Angle Gamma Angle
13
image 14
The indicated percentages refer to a typi-
cal installation and lead to a factor of use
UF which is in case (a) 0,8 x 0,55 = 0,4 and
in case (b) 0,8 x 0,75 = 0,6
3) Long lifetime of the LED allow to incre-
ase the reliability of an installation and to
reduce drastically the maintenance inter-
vals and therefore its costs in particular in
critical conditions like in tunnels.
Notice that not only the use of LED is
sufficient to really implement energy sa-
ving but the whole engineering parame-
ters are correctly defined like choice of
sources, optics, thermal management etc.
To determine in quantity if a lighting
fixture is good the first data to be consi-
dered is it’s efficiency (lm/W) (image 14).
In case of street lighting it is furthermore
necessary to define if a particular product
is suitable to illuminate a street. This can
be only done by knowing its photometry
and a light calculation to determine the
efficiency of the whole installation mea-
ning the amount of power needed to illu-
minate one kilometre [W/km].
At an international level attempts are
made to define a labelling method to the-
se parameters.
Carriage way: 2x3 m (tot. 6,0 m)Sidewalk: 1x2,5 mPole backing: 0,7 mDisposition: unilateral on the rightExcerpt: 0,3 mInterdistance: 24 mHeight: 8 m
FIXTURE Maintenance factor Fixture tilt cd/
m2 U gen U long T I % Sr medium
illum.min/med
illum.Power
absorptionSa-
ving
ST100W SUPER 0,8 0 * 1,11 0,55 0,85 6,61 0,56 11 0,58 120 -
STARLED 64/0,500 A 0,9 0 * 1 0,71 0,64 4 0,66 9 0,69 96 20,0%
STARLED 32/0,7 A 0,9 0 * 0,69 0,68 0,72 3,33 0,65 7 0,62 70 41,7%
Carriage way class ME4aSidewalk class S 4 >0,75 >0,40 >0,6 <15% >0,5 >3 -
CARRIAGE WAY SIDEWALK
With carriageway declassification
Carriage way: 2x3,5 m (tot. 7,0 m)Sidewalk: 1x1,5 mPole backing: 4,5 mDisposition: unilateral on the rightExcerpt: 0Interdistance: 25 mHeight: 8 m
FIXTURE Maintenance factor Fixture tilt cd/
m2 U gen U long T I % Sr medium
illum.min/med
illum.Power
absorptionSa-
ving
ST150W SUPER 0,8 10 * 1,56 0,42 0,79 9,02 0,64 31 0,62 170 -
STARLED 64/0,600 A 0,9 0 * 1,17 0,55 0,72 3,5 0,63 22 0,66 115 32,4%
STARLED 64/0,600 A 0,9 0 * 0,92 0,55 0,72 3,5 0,63 17 0,66 96 43,5%
Carriage way class ME4aSidewalk class S 4 >1 >0,40 >0,70 <15% >0,5 >7,5 -
CARRIAGE WAY SIDEWALK
With carriageway declassification
ST 100W
ST 150W
14
GALLERIE E TUNNEL
LED
IEC 62031 : 2008 LED Modules for General Lighting – Safety Specifications
IEC 62560 : 2011 Self-ballasted LED-lamps for general lighting services > 50 V - Safety specifications
IEC/PAS 62612 : 2009 Self-ballasted LED lamps for general lighting services > 50 V - Performance requirements
IEC 60061 series Lamp caps and holders together with gauges for the control of interchangeability and safety
IEC 60838-2-2 : 2006 Miscellaneous lampholders -Part 2-2: Particular requirements - Connectors for LEDmodules
IEC/TR 61341 : 2010 Method of measurement of centre beam intensity and beam angle(s) of reflector lamps
IEC 61231 : 2010 International lamp coding system (ILCOS)
IEC TS 62504 : 2011 Terms and definitions for LEDs and LED modules in general lighting
POWER SUPPLY UNIT
IEC 61347-1 : 2007 Lamp controlgear - Part 1: General and safety requirements
IEC 61347-2-13 : 2006 Lamp controlgear - Part 2-13 : Particular requirements for d.c. or a.c. suppliedelectronic controlgear for LED modules
IEC 62384 : 2006 + Amd 1 : 2009 DC or AC supplied electronic control gear for LED modules
electronic controlgear for LED modules
PERFORMANCE REQUIREMENTS
IEC 62386-101 : 2009 Digital addressable lighting interface – Part 101: General requirements – System
IEC 62386-102 : 2009 Digital addressable lighting interface – Part 102: General requirements - Control Gear
IEC 62386-207 : 2009 Digital addressable lighting interface – Part 207: Particular requirements for control gearLED modules (device type 6)
IEC 60598 series Luminaires
SYSTEMS
IEC 62471 : 2006 Photobiological safety of lamps and lamp systems
IEC/TR 62471-2 : 2009 Photobiological safety of lamps and lamp systems – art 2: Guidance on manufacturingrequirements relating to non-laser optical radiation safety
MEASUREMENTS
CIE 127 : 2007 Measurement of LEDs
EN 13032-1 Light and lighting - Measurement and presentation of photometric data of lamps andluminaires - Part 1: Measurement and file format
EN 13032-2 Light and lighting - Measurement and presentation of photometric data of lamps andluminaires - Part 2: Lighting of indoor work places
EMC- Electromagnetic compatibility
IEC 61547 : 2009 Equipment for general lighting purposes - EMC immunity requirements
IEC 61000-3-2 : 2009 Electromagnetic compatibility (EMC) -Part 3-2: Limits - Limits for harmonic currentemissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3 Limitation of voltage fluctuations and flicker in low-voltage supply systems forequipment with rated current ≤16 A
CISPR 15 : 2008 Limits and methods of measurement of radio disturbance characteristicsof electrical lighting and similar equipment
EMF - Electromagnetic fields
IEC 62493 : 2009 Assessment of lighting equipment related to human exposure to electromagnetic
APPLICABLE NORMSThe use of LED as a light source is a still young technology which has revolutionized the world of lighting fixtures and flooded the market also with unsafe and unreliable products. After the initial confusion, thanks to the effort of regulatory agencies lots of technical norms have been implemented to help producers to make good products. The norms are generally divided into safety and performance. Following the situation on IEC/EN norms concerning LED available at present:
GALLERIE E TUNNEL
Street Lighting
STARLED 1
STARLED 2
ZETA SBO LED
AVENIDA LED
CARRETERA LED
SUNLED 1
SUNLED 2
FASTLED ST
SATURN LED P
POWER N° LED IP KELVIN CLASS CODE PAGE
70 32 65 4000 K II 0005432243 19115 64 65 4000 K II 0005464243
175 96 65 4000 K II 000519624320
230 128 65 4000 K II 00051128243
34 32 65 4000 K II 0070832242SBO 21
70 32 66 4000 K II 0006132243 22
70 32 66 4000 K II 000623224323
96 64 66 4000 K II 0006264243
57 24 65 4000 K II 0005724444
2485 36 65 4000 K II 0005736444
114 48 65 4000 K II 0005748444
175 96 65 4000 K II 000589644425
230 128 65 4000 K II 00058128444
57 24 66 4000 K II 003792444426
85 36 66 4000 K II 0037936444
30 30 65 4300 K II 0006830343P27
30 30 65 4300 K II 0006830243P
GALLERIE E TUNNEL
Tunnel lighting
FASTLED TU
ZETA LED
BRENNERO LED
POWER N° LED IP KELVIN CLASS CODE PAGE
57 24 66 6000 K II 003792446230
85 36 66 6000 K II 0037936462
52 32 65 6000 K II 0070832361 31
60 48 65 6000 K II 007544801 32
SATURN LED S
SATURN LED T
SATURN LED A
POWER N° LED IP KELVIN CLASS CODE PAGE
30 30 65 4300 K II 0006830341S28
30 30 65 4300 K II 0006830241S
30 30 65 4300 K II 0006830341T28
30 30 65 4300 K II 0006830241T
30 30 65 4300 K II 0006830341A
30 30 65 4300 K II 0006830241A29
Floodlights POWER N° LED IP KELVIN CLASS CODE PAGE
85 36 10° 65 4000 K II 0037936447
85 36 25° 65 4000 K II 0037936448 33
85 36 40° 65 4000 K II 0037936449FASTLED PR
GALLERIE E TUNNEL
Outdoor Lighting
POWER N° LED IP KELVIN CLASS CODE PAGE
45 36 10° 65 RGB II 0037936947
45 36 25° 65 RGB II 0037936948 34
45 36 40° 65 RGB II 0037936949
35 30 10° 66 4000 K II 003141030
3535 30 25° 66 4000 K II 003142530
35 30 35° 66 4000 K II 003143530
FASTLED PR RGB
TIGER LED
HORIZONTE I
HORIZONTE I RGB
HORIZONTE E
TRUCK LED
HORIZONTE E RGB
TRUCK LED RGB
POWER N° LED IP KELVIN CLASS CODE PAGE
26÷55 24 40° 67 4000 K II 003662424436
26÷55 24 ASM 67 4000 K II 0036624249
43 36 40° 67 RGB II 003663629437
45 36 ASM 67 RGB II 0036636299
26÷55 24 40° 65 4000 K II 003672424438
26÷55 24 ASM 65 4000 K II 0036724249
35 36 40° 65 RGB II 003673629439
35 36 ASM 65 RGB II 0036636299
18 12 15° 67 2700 K II 008021511
40
18 12 30° 67 2700 K II 00802301118 12 90° 67 2700 K II 008029011
18 12 15° 67 5600 K II 00802151018 12 30° 67 5600 K II 00802301018 12 90° 67 5600 K II 008029010
22 18 15° 67 RGB II 00802151841
22 18 30° 67 RGB II 008023018
POWER N° LED IP KELVIN CLASS CODE PAGE
30 30 65 4300 K II 0006830341S28
30 30 65 4300 K II 0006830241S
30 30 65 4300 K II 0006830341T28
30 30 65 4300 K II 0006830241T
30 30 65 4300 K II 0006830341A
30 30 65 4300 K II 0006830241A29
GALLERIE E TUNNELSTRADALI
MAYA
IndoorPOWER N° LED IP KELVIN CLASS CODE PAGE
115 64 ASM 20 4000 K II 0038564249 42
52 DALI 120° 40 5000 K I 0197945150F1DALI43
52 DALI 120° 40 5000 K I 0197945150F2DALI
15 63° 20 2700 K I 0197307126
4415 63° 20 2700 K I 0197307226
15 63° 20 4000 K I 0197307146
15 63° 20 4000 K I 0197307246
12 DIM 60° 44 2700 K I 0197406126DIM
45
12 DIM 74° 44 2700 K I 0197406127DIM
14 DIM 60° 44 4000 K I 0197409146DIM
14 DIM 74° 44 4000 K I 0197409147DIM
15 DIM 60° 44 3000 K I 0197409136DIM
15 DIM 74° 44 3000 K I 0197409137DIM
27 DIM 60° 44 3000 K I 0197418136DALI
27 DIM 74° 44 3000 K I 0197418137DALI
27 DIM 60° 44 4000 K I 0197418146DALI
27 DIM 74° 44 4000 K I 0197426147DALI
37 DIM 60° 44 3000 K I 0197426136DALI
37 DIM 74° 44 3000 K I 0197426137DALI
37 DIM 60° 44 4000 K I 0197426146DALI
37 DIM 74° 44 4000 K I 0197426147DALI
13 99° 20-44 4000 K I 0197511140DK
46
15 99° 20-44 3000 K I 0197511130DK
26 99° 20-44 4000 K I 0197520140DK
28 99° 20-44 3000 K I 0197520130DK
46 99° 20-44 4000 K I 0197530140DK
40 99° 20-44 RGB I 0197509190DK
13 99° 20-44 4000 K I 0197511140SV
46
15 99° 20-44 3000 K I 0197511130SV
26 99° 20-44 4000 K I 0197520140SV
28 99° 20-44 3000 K I 0197520130SV
46 99° 20-44 4000 K I 0197530140SV
40 99° 20-44 RGB I 0197509190SV
13 80° 20 4000 K I 0197711148
47
15 80° 20 3000 K I 0197711138
26 80° 20 4000 K I 0197720148
28 80° 20 3000 K I 0197720138
46 80° 20 4000 K I 0197730148
50 80° 20 3000 K I 0197730138
MAGALED
INCA 125
INCA 236 DK
INCA 236 SV
INCA 184
INCA Q
LED Strip ip20-64-65 DA 1,8 A 14,4 W/m 20-65-67 2700-4000-5000 K 48
DMX Controller central unit dmx stand alone 49
COLOUR TABLES BI WHITE • AL ALUMINIUM • IN INOX • GR GREY • GRCF GUN STEEL GREY • GRV GREEN GREY • NE BLACK
19
GALLERIE E TUNNELSTREET LIGHTING
305
60 mm
110
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
STARLED 1 32 LED 0005432243 70 32 4900 4000 ≥75 65 II GR 10,0
STARLED 1 64 LED 0005464243 115 64 9200 4000 ≥75 65 II GR 10,0
Street and urban decoration lighting fixture with 32 or 64 power LED with secondary optic, optimized pho-tometry for street lighting purpose, cut-off. Compliant to norms concerning light pollution (e.g. UNI 10819). Body of diecast aluminium polyester powder coated in standard grey colour. Tempered calcic-sodium protection glass of 5mm. Silicone gaskets. Suitable for side pole mounting diameter 60mm or as post top mounting with separate accessories.Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Cable gland M20 (cable 9-11mm)Power correction factor > 0,98
STARLED 1
central unit dmx stand alone 49
200
200
400
600
800
1000
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
25155
Semipiani C
270.0
180.0 0.0
90.0
25.0
Mast diam.745 mm
Angle Gamma
Kg
20
GALLERIE E TUNNELSTREET LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
STARLED 2 96 LED 0005196243 175 96 14.100 4000 ≥75 65 II GR 18,2
STARLED 2 128 LED 00051128243 230 128 18.400 4000 ≥75 65 II GR 18,2
410
140
60 mm
Street and urban decoration lighting fixture with 96 or 128 power LED with secondary optic, optimized pho-tometry for street lighting purpose, cut-off. Compliant to norms concerning light pollution (e.g. UNI 10819). Body of diecast aluminium polyester powder coated in standard grey colour. Tempered calcic-sodium pro-tection glass of 5mm. Silicone gaskets.Suitable for side pole mounting diameter 60mm or as post top mounting with separate accessories (on request).Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Cable gland M20 (cable 9-11mm)Power correction factor > 0,98
STARLED 2
200
200
400
600
800
1000
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
25155
Semipiani C
270.0
180.0 0.0
90.0
25.0
Mast diam.
1000
Angle Gamma
Kg
21
GALLERIE E TUNNELSTREET LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
ZETA SBO 32 LED 0070832242SBO 34 32 2.200 4000 ≥75 65 II GR 5,0
Street and urban decoration lighting fixture with 32 power LED with secondary optic, optimized photo-metry for street lighting purpose, cut-off. Compliant to norms concerning light pollution (e.g. UNI 10819). Body of diecast aluminium (EN AB46100) polyester powder coated in standard grey colour. Tempered calcic-sodium protection glass of 5mm. Silicone gaskets.Polyamide cable gland PG 13,5 (cables 9-11mm).Twistable and adjustable decorative aluminium bracket (included) suitable for post top mounting 60mm.Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
ZETA SBO LED
200
200
400
600
800
1000
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
25155
Semipiani C
270.0
180.0 0.0
90.0
25.0
260
130
41060 mmMast diam.
Angle Gamma
Kg
22
GALLERIE E TUNNELSTREET LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
AVENIDA 32 LED 0006132243 70 32 4.900 4000 ≥75 66 II GR 8,7
Street lighting fixture with 32 power LED with secondary optic, optimized photometry for street lighting purpose, cut-off. Compliant to norms concerning light pollution (e.g. UNI 10819). Body of diecast aluminium (EN AB 46100) polyester powder coated in grey RAL9006. Tempered calcic-sodium protection glass of 5mm. Silicone gaskets.Suitable for post top and side entry mounting 60mm.Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
524
245
304
60 mm
AVENIDA LED
200
200
400
600
800
1000
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
25155
Semipiani C
270.0
180.0 0.0
90.0
25.0
Mast diam.
Angle Gamma
Kg
23
GALLERIE E TUNNELSTREET LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
CARRETERA 32 LED 0006232243 70 32 4900 4000 ≥75 66 II GR 11,5
CARRETERA 64 LED 0006264243 96 64 7250 4000 ≥75 66 II GR 11,5
Street lighting fixture with 32 or 64 power LED with secondary optic, optimized photometry for street ligh-ting purpose, cut-off. Compliant to norms concerning light pollution (e.g. UNI 10819). Body of diecast alumi-nium (EN AB 46100) polyester powder coated in grey RAL9006. Tempered calcic-sodium protection glass of 5mm. Silicone gaskets.Suitable for post top and side entry mounting 60 – 76mm. Orientable by 5° degree steps (+5° -15° side entry mounting and 0°-20° post top mounting).Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
667
245
330
60-76 mm
CARRETERA LED
200
200
400
600
800
1000
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
25155
Semipiani C
270.0
180.0 0.0
90.0
25.0
Mast diam.
Angle Gamma
Kg
24
GALLERIE E TUNNEL STREET LIGHTINGSTREET LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
SUNLED 1 24 LED 0005724444 57 24 4270 4000 ≥75 65 II GRCF 6,5
SUNLED 1 36 LED 0005736444 85 36 6400 4000 ≥75 65 II GRCF 6,5
SUNLED 1 48 LED 0005748444 114 48 8550 4000 ≥75 65 II GRCF 6,5
Street lighting fixture with 24, 36 or 48 power LED with secondary optic, optimized photometry for street lighting purpose, cut-off. Compliant to norms concerning light pollution (e.g. UNI 10819). Body of diecast aluminium polyester powder coated in gunmetal grey. Tempered calcic-sodium protection glass of 4mm. Silicone gaskets.Suitable for side pole mounting diameter 60mm or as post top mounting with separate accessories (on re-quest). Cable gland M20 (cable 9÷11 mm). Dimmable version on request.Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
SUNLED 1
572
242
718090
60 mm
200
200
400
600
800
1000
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
25155
Semipiani C
270.0
180.0 0.0
90.0
25.0
Mast diam.
Angle Gamma
Kg
25
GALLERIE E TUNNELSTREET LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
SUNLED 2 96 LED 0005896444 175 96 14.200 4000 ≥75 65 II GRCF 14,0
SUNLED 2 128 LED 00058128444 230 128 18.400 4000 ≥75 65 II GRCF 14,0
Street lighting fixture with 96 or 128 power LED with secondary optic, optimized photometry for street lighting purpose, cut-off. Compliant to norms concerning light pollution (e.g. UNI 10819). Possibility of LED driving with different currents. Body of diecast aluminium polyester powder coated in gunmetal grey. Tem-pered calcic-sodium protection glass of 4mm. Silicone gaskets.Suitable for side pole mounting diameter 60mm or as post top mounting with separate accessories (on re-quest). Cable gland M20 (cable 9÷11 mm). Dimmable version on request.Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
B2
3
72
374
796
60 mm
95 80
SUNLED 2
200
200
400
600
800
1000
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
25155
Semipiani C
270.0
180.0 0.0
90.0
25.0
Mast diam.
Angle Gamma
Kg
26
GALLERIE E TUNNELSTREET LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
FASTLED ST 24 LED 0037924444 57 24 4200 4000 ≥75 66 II GRCF 3,0
FASTLED ST 36 LED 0037936444 85 36 6400 4000 ≥75 66 II GRCF 3,0
Street lighting floodlight with 24 or 36 power LED with secondary optic, optimized photometry for street lighting purpose, cut-off. Compliant to norms concerning light pollution (e.g. UNI 10819). Body of diecast aluminium polyester powder coated in gunmetal grey. Tempered calcic-sodium protection glass of 4mm. Silicone gaskets.Fixing bracket in galvanized steel. Post top mounting accessory on request.Cable gland M20 (cable 9÷11 mm). Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
38042724
0
70
35
252
34 34
FASTLED ST
200
200
400
600
800
1000
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
25155
Semipiani C
270.0
180.0 0.0
90.0
25.0
Angle Gamma
holes 8,5mm
Kg
27
GALLERIE E TUNNELSTREET LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
SATURN LED 30 P 0006830343P 30 30 3100 4300 75 65 II NE 8,0
SATURN LED 30 P 0006830243P 30 30 3100 4300 75 65 II GR 8,0
Street lighting fixture with 30 power LED with secondary optic, optimized photometry for street lighting purpose, cut-off. Compliant to norms concerning light pollution (e.g. UNI 10819). Body of diecast aluminium degreased and phosphor chromatized and polyester powder coated in graphite black RAL9011, on request powder coated in grey RAL9006 gross finish. UV and saline fog resistant. Inside part of white galvanized ste-el. Tempered calcic-sodium protection glass of 5mm. Silicone gaskets. Top opening with stainless steel screws INOX AISI 304.Post top or side pole mounting diameter 60mm. Adjustable by 2,5° degree steps, fixing by means of 4 stainless steel grains.Cable gland M20 (cable 9÷11 mm). Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
SATURN LED 30 P
MAX0,187mq
282
488
564612
190
143
60 mm
200
200
400
600
800
10000˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0180
90
270
40140
Semipiani C
180.00 .090.0
270.0140.0 40.0
Mast diam.
Angle Gamma
Kg
28
GALLERIE E TUNNELSTREET LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
SATURN LED 30 S 0006830341S 30 30 2900 4300 75 65 II NE 7,5
SATURN LED 30 T 0006830341T 30 30 2900 4300 75 65 II NE 7,5
SATURN LED 30 S 0006830241S 30 30 2900 4300 75 65 II GR 7,5
SATURN LED 30 T 0006830241T 30 30 2900 4300 75 65 II GR 7,5
Street lighting fixture with 30 power LED with secondary optic, optimized photometry for urban decoration purpose. Compliant to norms concerning light pollution (e.g. UNI 10819). Body of diecast aluminium degrea-sed and phosphor chromatized and polyester powder coated in graphite black RAL9011, on request powder coated in grey RAL9006 gross finish. UV and saline fog resistant. Inside part of white galvanized steel. Tem-pered calcic-sodium protection glass of 5mm. Silicone gaskets. Bottom opening with stainless steel screws INOX AISI 304.S-version: suspension mounting under console by stainless steel gas 1” thread male, the console must be provided with a reduction bush 1” gas female T-version: suspension mounting on chains of 4-8mm thickness, brass PG13,5 entranceCable gland M20 (cable 9÷11 mm). Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
SATURN LED 30 S and T
S T
S
T
488
192
MAX0,182mq
246
19228
0
250
250
500
750
1000
12500˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0180
90
270
175 5
Semipiani C180.0 0.0
90.0270.0175.0 5.0
1 inchmale
Angle Gamma
Kg
29
GALLERIE E TUNNELSTREET LIGHTINGSTREET LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
SATURN LED 30 A 0006830341A 30 30 3900 4300 75 65 II NE 9,5
SATURN LED 30 A 0006830241A 30 30 3900 4300 75 65 II GR 9,5
Urban decoration and street lighting fixture with 30 power LED with secondary optic, optimized photome-try for urban decoration. Compliant to norms concerning light pollution (e.g. UNI 10819). Body of diecast aluminium degreased and phosphor chromatized and polyester powder coated in graphite black RAL9011, on request powder coated in grey RAL9006 gross finish. UV and saline fog resistant. Inside part of white gal-vanized steel. Tempered calcic-sodium protection glass of 5mm. Silicone gaskets. Top opening with stainless steel screws INOX AISI 304. Power cut-off device.Post top pole mounting diameter 60mm. Cable gland M20 (cable 9÷11 mm). Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
SATURN LED 30 A
488
192MAX
0,182mq
703
60 mm
250
250
500
750
1000
12500˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0180
90
270
175 5
Semipiani C180.0 0.0
90.0270.0175.0 5.0
Mast diam.
Angle Gamma
Kg
30
GALLERIE E TUNNELTUNNEL LIGHTING
380427
240
70
Floodlight for tunnel lighting purpose with 24 or 36 power LED. Suitable for illumination of the permanent part in tunnels. Specific secondary optic for tunnel light, cut-off. Body of diecast aluminium polyester powder coated in gunmetal grey. Tempered calcic-sodium protection glass of 4mm. Silicone gaskets.Fixing bracket in galvanized steel. On request cable tray fixing clips available for quick installation.On request dimmable and/or remote controlled versions.Cable gland M20 (cable 9÷11 mm). Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
FASTLED TU 24 LED 0037924462 57 24 4750 6000 ≥75 66 II GRCF 3,0
FASTLED TU 36 LED 0037936462 85 36 7135 6000 ≥75 66 II GRCF 3,0
FASTLED TU
Clips inox150
150
300
450
600
7500˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
Semipiani C
270.0180.00 .0
90.0
Angle Gamma
Kg
31
GALLERIE E TUNNEL
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
ZETA LED 32 OO70832361 52 32 3700 6000 52 65 II NE 5,00
TUNNEL LIGHTING
260
130
41046040
230 70
70
Floodlight for tunnel lighting purpose with 32 power LED. Suitable for illumination of the permanent part in tunnels. Specific primary silicone optic for tunnel light, cut-off. Body of diecast aluminium (EN AG 46100) polyester powder coated in black. Tempered calcic-sodium pro-tection glass of 4mm. Silicone gaskets.Fixing bracket in galvanized steel. On request cable tray fixing clips available for quick installation.On request dimmable and/or remote controlled versions.Cable gland PG13,5 (cable 9÷11 mm). Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
ZETA LED
Clips inox200
200
400
600
800
10000˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
5175
Semipiani C270.0180.0 0.0
90.0175.0 5.0
Angle Gamma
2 holes 10,5
1 hole 14,0 mm
Kg
32
GALLERIE E TUNNELTUNNEL LIGHTING
Clips inox
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
BRENNERO 48 LED 007544801 60 48 4700 6000 ≥75 65 II IN 9,7
Floodlight for tunnel lighting purpose with 48 power LED. Suitable for illumination of the permanent part in tunnels. Specific primary silicone optic for tunnel light, cut-off. Body of stainless steel INOX AISI 316-L or 304. Tempered calcic-sodium protection glass of 4mm. Silicone gaskets.Fixing bracket in galvanized steel. On request cable tray fixing clips available for quick installation.On request dimmable and/or remote controlled versions.Nickeled brass cable gland PG16 (cable 11÷15 mm). Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
581
314
8550
604
BRENNERO LED
200
200
400
600
800
10000˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
270
0180
90
5175
Semipiani C270.0180.0 0.0
90.0175.0 5.0
Angle Gamma
Kg
33
GALLERIE E TUNNELFLOODLIGHT
Goniometer
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
FASTLED PR 10° 0037936447 10° 85 36 6400 4000 ≥75 66 II GRCF 3,0
FASTLED PR 25° 0037936448 25° 85 36 6400 4000 ≥75 66 II GRCF 3,0
FASTLED PR 40° 0037936449 40° 85 36 6400 4000 ≥75 66 II GRCF 3,0
Floodlight with 36 power LED. Secondary circular optic in 10°, 25° or 40° opening.Body of diecast aluminium polyester powder coated in gunmetal grey. Tempered calcic-sodium protection glass of 4mm. Silicone gaskets.Fixing bracket in galvanized steel. On request with goniometer to fix the floodlight in a specific position.Cable gland M20 (cable 9÷11 mm). Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
380427
240
70
35
252
34 34
FASTLED PR
TUNNEL LIGHTING
3000
3000
6000
9000
12000
15000
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0
90
270
180
380mm x 283mm
Semipiani C
180.0 0.0
270.0 90.0
Angle Gamma
holes 8,5mm
Kg
34
GALLERIE E TUNNELFLOODLIGHT
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
FASTLED PR RGB 10° 0037936947 10° 85 36 - RGB - 65 II GRCF 3,0
FASTLED PR RGB 25° 0037936948 25° 85 36 - RGB - 65 II GRCF 3,0
FASTELD PR RGB 40° 00379336949 40° 85 36 - RGB - 65 II GRCF 3,0
Floodlight with 36 power RGB LED. Secondary circular optic in 25°.Body of diecast aluminium polyester powder coated in gunmetal grey. Tempered calcic-sodium protection glass of 4mm. Silicone gaskets.Fixing bracket in galvanized steel. On request with goniometer to fix the floodlight in a specific position.Cable gland M20 (cable 9÷11 mm). Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
380427
240
70
35
252
34 34
FASTLED PR RGB
DMX controler (see page 49)
Goniometer3000
3000
6000
9000
12000
15000
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0
90
270
180
380mm x 283m m
Semipiani C
180.0 0.0
270.0 90.0
Angle Gamma
holes 8,5mm
Kg
35
GALLERIE E TUNNELFLOODLIGHT
PROIETTORI
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
TIGER LED 10° 003141030 10° 35 30 2450 4000 ≥75 65 II GR 3,0
TIGER LED 25° 003142530 25° 35 30 2450 4000 ≥75 65 II GR 3,0
TIGER LED 35° 003143530 35° 35 30 2450 4000 ≥75 65 II GR 3,0
Floodlight with 30 power LED with secondary optic in 10°, 25° or 35°. Body of diecast aluminium (EN AB 46100) polyester powder coated in grey RAL9006. Tempered calcic-sodium protection glass of 5mm. Silico-ne gaskets. Fixing bracket in galvanized steel.Cable gland M20 (cables 9-11mm).Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
35
34
TIGER LED
300
300
600
900
1200
1500
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
H0
V0
Piani VH
H0.0
V0.0
Angle Gamma
holes 8,5mm
Kg
340 29621
4
112
36
GALLERIE E TUNNELOUTDOOR LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
HORIZONTE I 40° 0036624244 40° 26-55 24 1600 ÷ 2900 4000 ≥75 67 II AL 4,2
HORIZONTE I ASM 0036624249 ASM 26-55 24 1600 ÷ 2900 4000 ≥75 67 II AL 4,2
Inground floodlight with 24 power LED. Secondary optic 40° or asymmetric. Body of extruded aluminium. Tempered calcic-sodium protection glass of 4mm. Silicone gaskets. Inground installation form included.LED driver current can be set to 0,350 – 0,500 – 0,700 mACable gland M12 (cables 4-6mm).Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
5290
90
HORIZONTE I LED
700
700
1400
2100
2800
3500
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0180
90
270
135
315
1502mm x 76mm
Semipiani C
180.0 0.0
270.0 90.0
135.0 315.0
Angle Gamma
Kg
1225
1218BODY INGROUND INSTALLATION FORM
37
GALLERIE E TUNNELOUTDOOR LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
HORIZONTE I RGB 40° 0036636294 40° 43 36 - RGB - 67 II AL 4,2
HORIZONTE I RGB ASM 0036636299 ASM 43 36 - RGB - 67 II AL 4,2
Inground floodlight with 24 power RGB LED. Secondary optic 40° or asymmetric. Body of extruded alumi-nium. Tempered calcic-sodium protection glass of 4mm. Silicone gaskets. Inground installation form inclu-ded.On request with DMX or other control systems.Cable gland M12 (cables 4-6mm).Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
5290
90
HORIZONTE I LED RGB
700
700
1400
2100
2800
3500
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0180
90
270
135
315
1502mm x 76mm
Semipiani C
180.0 0.0
270.0 90.0
135.0 315.0
Angle Gamma
Kg
1225
1218BODY INGROUND INSTALLATION FORM
38
GALLERIE E TUNNELOUTDOOR LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
HORIZONTE E 40° 0036724244 40° 26-55 24 1600 ÷ 2900 4000 ≥75 65 II GRV 4,5
HORIZONTE E ASM 0036724249 ASM 26-55 24 1600 ÷ 2900 4000 ≥75 65 II GRV 4,5
Wall washer with 24 power LED. Secondary optic 40° or asymmetric. Body of extruded aluminium. Tempered calcic-sodium protection glass of 4mm. Silicone gaskets. Two fixing brackets included.LED driver current can be set to 0,350 – 0,500 – 0,700 mADimmable versions on request.Cable gland M12 (cables 4-6mm).Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
1.502
108
76165
HORIZONTE E LED
700
700
1400
2100
2800
3500
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0180
90
270
135
315
1502mm x 76mm
Semipiani C
180.0 0.0
270.0 90.0
135.0 315.0
Angle Gamma
Kg
39
GALLERIE E TUNNELOUTDOOR LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
HORIZONTE E RGB 40° 0036736294 40° 35 36 - RGB - 65 II GRV 4,5
HORIZONTE E RGB ASM 0036736299 ASM 35 36 - RGB - 65 II GRV 4,5
Wall washer with 36 power LED. Secondary optic 40° or asymmetric. Body of extruded aluminium. Tempe-red calcic-sodium protection glass of 4mm. Silicone gaskets. Two fixing brackets included.Dimmable versions on request.Cable gland M12 (cables 4-6mm).Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
1.502
108
76165
HORIZONTE E LED RGB
OUTDOOR LIGHTING
700
700
1400
2100
2800
3500
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0180
90
270
135
315
1502mm x 76mm
Semipiani C
180.0 0.0
270.0 90.0
135.0 315.0
Angle Gamma
Kg
40
GALLERIE E TUNNELOUTDOOR LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
TRUCK LED 15° 2700 008021511 15° 18 12 720 2700 ≥75 67 I IN 3,6
TRUCK LED 30° 2700 008023011 30° 18 12 720 2700 ≥75 67 I IN 3,6
TRUCK LED 90° 2700 008029011 90° 18 12 720 2700 ≥75 67 I IN 3,6
TRUCK LED 15° 5600 008021510 15° 18 12 720 5600 ≥75 67 I IN 3,6
TRUCK LED 30° 5600 008023010 30° 18 12 720 5600 ≥75 67 I IN 3,6
TRUCK LED 90° 5600 008029010 90° 18 12 720 5600 ≥75 67 I IN 3,6
In ground floodlight with 12 power LED with secondary optic in 15°, 30° or 90°. Body of diecast aluminium (EN AB 46100) polyester powder coated in black. Tempered calcic-sodium protection. Glass frame of stainless steel INOX AISI 316L. Stainless steel screws. Silicone gaskets. Resistant to static weight of 2500kg. In ground installation pot PA-ED in nylon included.Connection neoprene cable 2x1,5mm² of 2,5m included12V operation, any 12V LED driver (22W min.) in high IP is suitable.Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
220
259
255 17
0
TRUCK LED
0
250
500
750
1000
1250
1500
1750
2000
-90 -60 -30 0 30 60 90
cd/klmH0
V0V0
Piani VH
H0.0
V0.0
Kg
41
GALLERIE E TUNNELOUTDOOR LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
TRUCK LED RGB 15° 008021518 15° 22 18 - RGB - 67 I IN 4,1
TRUCK LED RGB 30° 008023018 30° 22 18 - RGB - 67 I IN 4,1
In ground floodlight with 18 power RGB LED with secondary optic in 15° or 30°. Body of diecast alumi-nium (EN AB 46100) polyester powder coated in black. Tempered calcic-sodium protection. Glass frame of stainless steel INOX AISI 316L. Stainless steel screws. Silicone gaskets. Resistant to static weight of 2500kg. In ground installation pot PA-ED in nylon included.Connection neoprene cable 6x1,5mm² of 2,5m included (L-N-E +DMX)12V operation, any 12V LED driver (22W min.) in high IP is suitable.External DMX controller needed.Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
220
259 17
0
TRUCK LED RGB
DMX controler (see page 49)
OUTDOOR LIGHTING
255
0
250
500
750
1000
1250
1500
1750
2000
-90 -60 -30 0 30 60 90
cd/klmH0
V0V0
Piani VH
H0.0
V0.0
Kg
42
GALLERIE E TUNNELINDOOR LIGHTING
DESCRIPTIONCode Power Nr. LED Lumen Kelvin CRI IP Class Colour Weight
MAGALED ASM 0038564249 ASM 115 64 9000 Im 4000 K ≥75 20 II AL 9,7
Floodlight with 64 Power LED with seconday asymmetric optic 18x36°. Suitable for shop or warehouse aisle illumination. Body of anodized extruded aluminium. Fixing plates made of galvanized steel, included.Applicable norms EN 60598-1, EN 60598-2-5, EN6100-3-2, EN 55015Power correction factor > 0,98
160
103,
5
85
113
103,5
MAGALED
700
700
1400
2100
2800
3500
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0180
90
270
135
315
1502mm x 76mm
Semipiani C
180.0 0.0
270.0 90.0
135.0 315.0
Angle Gamma
Kg
2100
43
GALLERIE E TUNNELINDOOR LIGHTING
Recessed LED lighting fixture. Optical system by prismatic microdiffuser. Electronic dimmable DALI dri-ver. Emergency execution on request. Body of steel sheet. Frame of estrude aluminium profiles. Diffuser in PMMA. Powdercoated in white RAL9003 colour. For ambient temperature of up to 35°C. Lifetime expectancy 50.000hF1 version for mounting inside false ceiling structureF2 version for mounting below false ceiling structureAccessories for installation in plasterboard ceilings on request.
919
571
595
573
595
DESCRIPTIONCode Power Lumen Kelvin CRI IP Class Colour Weight
MAYA LED F1 DALI 0197945150F1DALI 120° 52 4500 5000 >80 40 I BI 6,3
MAYA LED F2 DALI 0197945150F2DALI 120° 52 4500 5000 >80 40 I BI 6,3
MAYA
INDOOR LIGHTING
80
80
160
240
320
400
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0
180
90
270
17.5
197.5
595mm x 595mm
Semipiani C
180.0 0.0
270.0 90.0
17.5
Angle Gamma
Kg
44
GALLERIE E TUNNELINDOOR LIGHTING
DESCRIPTIONCode Power Lumen Kelvin CRI IP Class Colour Weight
INCA 125 2700 BI 0197307126 63° 15 700 2700 90 20 I BI 0,4
INCA 125 2700 GR 0197307226 63° 15 700 2700 90 20 I GR 0,4
INCA 125 4000 BI 0197307146 63° 15 700 4000 90 20 I BI 0,4
INCA 125 4000 GR 0197307246 63° 15 700 4000 90 20 I GR 0,4
Recessed LED lighting fixture. Direct light.Body and frame of steel powdercoated in white RAL9003 or grey RAL9006Anodized aluminium reflector.For ambient temperature of up to 35°C. Lifetime expectancy 25.000h
INCA 125
180
25
MIN.
125 125
107
125
FORO INCASSODIAMETRO 110 mm
maximum ThicKness
FORO INCASSODIAMETRO 110 mm
250
250
500
750
1000
1250
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0
180
Diam=125mm
Semipiani C
180.0 0.0
Angle Gamma
Cut out of 110 mm diameter
Kg
45
GALLERIE E TUNNELINDOOR LIGHTING
DESCRIPTIONCode Power Lumen Kelvin CRI IP Class Colour Weight
INCA 184 12 DIM 60° 0197406126DIM 60° 12 650 2700 > 90 44 I BI 0,7
INCA 184 12 DIM 74° 0197406127DIM 74° 12 650 2700 > 90 44 I BI 0,7
INCA 184 15 4 DIM 60° 0197409146DIM 60° 15 900 4000 > 90 44 I BI 0,7
INCA 184 15 4 DIM 74° 0197409147DIM 74° 15 900 4000 > 90 44 I BI 0,7
INCA 184 15 DIM 60° 0197409136DIM 60° 15 900 3000 > 90 44 I BI 0,7
INCA 184 15 DIM 74° 0197409137DIM 74° 15 900 3000 > 90 44 I BI 0,7
INCA 184 27 DALI 60° 0197418136DALI 60° 27 1800 3000 > 90 44 I BI 1,5
INCA 184 27 DALI 74° 0197418137DALI 74° 27 1800 3000 > 90 44 I BI 1,5
INCA 184 27 4 DALI 60° 0197418146DALI 60° 27 1800 4000 > 90 44 I BI 1,5
INCA 184 27 4 DALI 74° 0197418147DALI 74° 27 1800 4000 > 90 44 I BI 1,5
INCA 184 37 DALI 60° 0197426136DALI 60° 37 2650 3000 > 90 44 I BI 1,5
INCA 184 37 DALI 74° 0197426137DALI 74° 37 2650 3000 > 90 44 I BI 1,5
INCA 184 37 4 DALI 60° 0197426146DALI 60° 37 2650 4000 > 90 44 I BI 1,5
INCA 184 37 4 DALI 74° 0197426147DALI 74° 37 2650 4000 > 90 44 I BI 1,5
Recessed LED lighting fixture. Direct light.Body of polycarbonate and frame of steel powdercoated in white RAL9003 Reflector of specular polished aluminium. Optical opening angles of 60° or 74°Dimmable driver for 12W and 15W versions.Mounting plate for T profile false ceilings on request.
INCA 184
INDOOR LIGHTING
4150
184
220MIN.FORO INCASSO
DIAMETRO 110 mm
250
250
500
750
1000
1250
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0
180
Diam=185mm
Semipiani C
180.0 0.0
Angle Gamma
Cut out of 170 mm diameter
Kg
46
GALLERIE E TUNNELINDOOR LIGHTING
DESCRIPTIONCode Power Lumen Kelvin CRI IP Class Colour Weight
INCA 236 13 DK 0197511140DK 99° 13 1100 4000 80 20-44 I BI 1,5INCA 236 15 DK 0197511130DK 99° 15 1100 3000 80 20-44 I BI 1,5INCA 236 26 DK 0197520140DK 99° 26 2000 4000 80 20-44 I BI 1,9INCA 236 28 DK 0197520130DK 99° 28 2000 3000 80 20-44 I BI 1,9INCA 236 46 DK 0197530140DK 99° 46 3000 4000 80 20-44 I BI 2,4INCA 236 40 DK 0197509190DK 99° 40 900 RGB W 80 20-44 I BI 2,4
INCA 236 13 SV 0197511140SV 99° 13 1100 4000 80 20-44 I BI 1,5INCA 236 15 SV 0197511130SV 99° 15 1100 3000 80 20-44 I BI 1,5INCA 236 26 SV 0197520140SV 99° 26 2000 4000 80 20-44 I BI 1,9INCA 236 28 SV 0197520130SV 99° 28 2000 3000 80 20-44 I BI 1,9INCA 236 46 SV 0197530140SV 99° 46 3000 4000 80 20-44 I BI 2,4INCA 236 40 SV 0197509190SV 99° 40 900 RGB W 80 20-44 I BI 2,4
RGB W RGB + Intelligent white - da 2700 a 6500 K
Recessed LED lighting fixture. Direct light.Body of and frame of galvanized steel powdercoa-ted in white RAL9003.Specular metalized polycarbonate (DK) or white (SV) reflector. Optical opening angle of 99°Driver with active temperature control for 2000 and 3000lm versionsDriver with passive temperature control for 1100lm versionsOn request dimmable drivers available (10-100%)Mounting plate for T profile false ceilings on re-quest.3-pole connectors Wieland GST 18i3 or Wago Win-sta 770 on requestStandard version in IP20, IP44 with diffuser or de-corative glass on request
INCA 236 DK - SV
SV
DK
45378
453
125
236220
250MIN.
100
100
200
300
400
500
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0
180
Diam=236mm
Semipiani C
180.0 0.0
For IP44 version, o r d e r c los ing glass
Angle Gamma
Cut out of 224 mm diameter
Kg
47
GALLERIE E TUNNELINDOOR LIGHTING
Recessed LED lighting fixture. Direct light.Body and frame of of steel powdercoated in white RAL9003 Reflector of polished aluminium. Dimmable DALI driver on request.
DESCRIPTIONCode Power Lumen Kelvin CRI IP Class Colour Weight
INCA Q 13 0197711148 80° 13 1050 4000 80 20 I BI 2
INCA Q 15 0197711138 80° 15 1050 3000 80 20 I BI 2
INCA Q 26 0197720148 80° 26 1950 4000 80 20 I BI 2
INCA Q 28 0197720138 80° 28 1950 3000 80 20 I BI 2
INCA Q 46 0197730148 80° 46 2950 4000 80 20 I BI 2
INCA Q 50 0197730138 80° 50 2950 3000 80 20 I BI 2
INCA Q
INDOOR LIGHTING
226
100 22
6
150MIN.
250
250
500
750
1000
1250
0˚ 15˚15˚ 30˚30˚
45˚45˚
60˚60˚
75˚75˚
90˚90˚
105˚105˚
120˚180˚
cd/klm
0
180
Diam=185mm
Semipiani C
180.0 0.0
Angle Gamma
Cut out of 210x210 mm
Kg
48
GALLERIE E TUNNEL
CODE Input V DC W/m LED/m IP ColourDimensions
mm
FS353020xxyy 12 0 24 1,8 ÷ 2,4 30 20 WHITE 8 x 5000
FS356020xxyy 12 0 24 4,8 60 20 WHITE 8 x 5000
FS356065xxyy 12 0 24 4,8 60 65 WHITE 8 x 5000
FS356067xxyy 12 0 24 4,8 60 67 WHITE 8 x 5000
FS503020xxyy 12 0 24 7,2 30 20 WHITE 10 x 5000
FS503065xxyy 12 0 24 7,2 30 65 WHITE 10 x 5000
FS506020xxyy 12 0 24 14,4 60 20 WHITE 10 x 5000
FS506065xxyy 12 0 24 14,4 60 65 WHITE 10 x 5000
FS506067xxyy 12 0 24 14,4 60 67 WHITE 10 x 5000
FS503020xxRGB 12 0 24 7,2 30 20 RGB 10 x 5000
FS503065xxRGB 12 0 24 7,2 30 65 RGB 10 x 5000
FS506020xxRGB 12 0 24 14,4 60 20 RGB 10 x 5000
FS506065xxRGB 12 0 24 14,4 60 65 RGB 10 x 5000
FS506067xxRGB 12 0 24 14,4 60 67 RGB 10 x 5000
Flexible LED strip in indoor IP20 and outdo-or IP65 and IP67 version.Colour temperatures of 2700°K, 4000°K and 5000°K in white or RGBSupplied in 5m rolls. Can be cut in any part to allow various length requirements.End caps and supply cable are included.Requires external LED driver (12V DC or 24V DC), wattage according to W/m, normal or specific for RGB LED.3M double sided glue tape included.
To complete the product code when ordering please substitute the following variables:
xx -> supply tension : 12 for 12V DC or 24 for 24V DCyy -> colour temperature: 2k for 2700°K or 4k for 4000°K or 5k for 5000°K
Example given:
FS503065xxyy -> FS503065122k = IP65 strip 30 Led/m 12V DC 2700°K
LED STRIP
49
GALLERIE E TUNNEL
Standalone DMX controlling device
DMX interface suitable for light scene progamma-
tion.
Needs to be configurated. Easy configuration
through specific program (32bit).
Connection to PC via USB port. After programma-
tion the controller can work as a standalone device.
Memory in stand alone mode.
Connection to network by XLR connector
Cables for connection not included
In stand alone mode the device has to be con-
nected to a 5V DC power supply unit with USB con-
nection (not included)
Software for configuration and light scene mana-
gement included
Recommended use with VST DMX power supply
Management: DMX 512
Power supply: DC 5 V
DMX channels: 60
CONTROLLER DMX
DESCRIPTION Code USB
Channels DMX Gates Memory capability Dimensions(mm)
WeightLive
modeStand alone
IN/OUT DMX
channels20 60 125
L L1 B H
Controller DMX
00054632 1,1 128 60 4 + 2 125 sTeps 45 sTeps - 90 92 79 40 93
Kg
50
GALLERIE E TUNNEL
Notes
51
GALLERIE E TUNNEL
Printed GRAFICHE LUVRITI (Provaglio di Iseo • Bs)
october 2012
select Lightwww.Select-Light.comLighting Shop
Tienda, Proyectos y Distribución
Light
+34 902 995 715