Page 1: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

DTG 230 SGas-fired boilers

User Guide

300011506-03

en

Page 2: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

.

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31.1 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31.2 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

1.2.1 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31.2.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31.2.3 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2 Safety instructions and recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53.1 Main parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53.2 Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3.2.1 B3 control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63.2.2 DIEMATIC-m3 control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73.2.3 K3 control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

4 Operating the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84.1 Commissioning the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84.2 Changing the settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

4.2.1 B3 control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84.2.2 DIEMATIC-m3 control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94.2.3 K3 control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

4.3 Switching off the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104.3.1 Precautions to take if there is a danger of frost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104.3.2 Precautions to take in the event of prolonged shutdown (one year or more). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

4.1 Commissioning the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

5 Checking and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116.1 Type plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116.2 Error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

6.2.1 B3 control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116.2.2 DIEMATIC-m3 control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126.2.3 K3 control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

6.3 Incidents and solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

7 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

8 Energy savings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

2 DTG 230 27/02/2018 - 300011506-03

Page 3: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

1. Introduction

1 Introduction

1.1 Symbols used

Caution dangerRisk of injury and damage to equipment. Attention must bepaid to the warnings on safety of persons and equipment.

Specific informationInformation must be kept in mind to maintain comfort.

ReferenceRefer to another manual or other pages in this instructionmanual.

DHW: Domestic hot water

1.2 General

Congratulations on your choice of a high quality product. Westrongly advise you to read the following instructions in order toguarantee the optimal operation of your appliance. We are surethat it will be entirely to your satisfaction and will meet with allof your expectations.

Keep these instructions in a safe place close to the appliance.

In the interest of customers, De Dietrich Thermique SAS arecontinuously endeavouring to make improvements in product quality.All the specifications stated in this document are therefore subject tochange without notice.

1.2.1 Manufacturer's liability

The liability of De Dietrich Thermique SAS as the manufacturer may notbe invoked in the following cases:

- Failure to abide by the instructions on using the appliance, - Faulty or insufficient maintenance of the appliance, - Failure to abide by the instructions on installing the appliance

1.2.2 Installer's liability

The installer is responsible for the installation and commissioning ofthe appliance. The installer must respect the following instructions:

Read and follow the instructions given in the manuals providedwith the appliance,

Carry out installation in compliance with the prevailinglegislation and standards,

Perform the initial start up and carry out any checks necessary

When handing over the installation to the user, the installer will drawthe user's particular attention to the following points:

- The safety of the installation,- The functioning of the installation and the boiler,- Periodic maintenance to be done.

1.2.3 User's liability

To ensure the optimum operation of your appliance, we stronglyrecommend that you abide by the following instructions :

Read and follow the instructions given in the manuals providedwith the appliance.

Call on qualified professionals to:

- Carry out installation in compliance with the prevailing legislationand standards

- Perform the initial start up- Carry out work on the appliance and the installation- Ensure the Appliance is serviced in accordance with the

manufacturer's instructions by a suitable qualified person- Get your installer to explain your installation to you.

327/02/2018 - 300011506-03 DTG 230

Page 4: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

2. Safety instructions and recommendations

2 Safety instructions and recommendations

2.1 Safety instructions

Fire hazardDo not stock products of an inflammable nature close tothe appliance.

If you smell gas, do not use a naked flame, do not smoke,do not operate electrical contacts or switches (doorbell,lights, motor, lift, etc.).1.Shut off the gas supply2.Open the windows3.Extinguish all flames4.Evacuate the premises5.Contact a qualified professional6.Inform the gas supplier

Risk of intoxicationDo not obstruct the air inlets in the room (even partially).

If you smell flue gases1.Switch the appliance off2.Open the windows3.Evacuate the premises4.Contact a qualified professional

Risk of being burntAvoid direct contact with the flame viewport.

Depending on the settings of the appliance:

- The temperature of the flue gas conduits may exceed 60°C- The temperature of the radiators may reach 95°C- The temperature of the domestic hot water may reach 65°C

Risk of damageDo not stock chloride or fluoride compounds close to theappliance.

Install the appliance in frost-free premises.

Do not neglect to service the appliance: Contact a qualifiedprofessional or take out a maintenance contract for the annualservicing of the appliance.

2.2 Recommendations

Only qualified professionals are authorised to work on theappliance and the installation.

Before any work, switch off the mains supply to theappliance.

Check regularly that the installation contains water and ispressurised.Keep the appliance accessible at all times.Avoid draining the installation.The appliance should be on Summer or Antrifreeze mode rather thanswitched off to guarantee the following functions:

- Antifreeze protection- Protection against corrosion on domestic hot water tanks fitted

with a titanium anode

4 DTG 230 27/02/2018 - 300011506-03

Page 5: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

3. Description

3 Description

3.1 Main parts

7 to 13 sections 14 sections

1. Control panel2. Factory fitted bridge

Connection for gas pressure switch (Option - Package GC191)Natural gas: 12.5 mbarPropane: 20 mbar

3. a: Gas valve - Stage 1b: Gas valve - Stage 2

4. a: Flame inspection window - Stage 1b: Flame inspection window - Stage 2

5. a: Ignition electrodeb: Ionization probe

6. Safety box7. Valve connector - Stage 28. Safety control box and valve connector - Stage 19. Downdraught thermostat

7-9 sections: delivered with the boiler10-14 sections: Option (Package GC22) - Factory fitted bridge

Russia: The downdraught thermostat is compusory for allmodels of boiler and must be fitted systematically. Thedowndraught thermostat is delivered with thedocumentation package.

10. Not used (Factory fitted bridge)11. Factory fitted bridge

- Connection for cyclical tightness controller (Option - PackageCY41)or- Connection for safety valve (Option - Package GC191)

527/02/2018 - 300011506-03 DTG 230

Page 6: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

3. Description

3.2 Control panel

3.2.1 B3 control panel

1. General ON (1) / OFF (0) switch

2. Burner alarm indicator + Reset buttonThis light comes on when the safety control box is in safetylockout (out of order).

3. Switch TEST-STB/ /: Heating and domestic hot water are in operation: Only domestic hot water is in operation

Position TEST-STB: Temporary action to test the safetythermostat

4. Safety thermostat with manual resetSet to 110° C

5. Timed circuit breaker (4 A)

6. Pump shutdown switch

7. Electronic thermostat (30 to 90 °C)

8. Heating on light

9. Location for flue gas thermometer (optional)

10. Switch for selecting the number of burner stages(2-stage boilers)

11. Digital display- Light 8 lit: Boiler temperature display- Light 13 lit: Domestic hot water display

When preparing domestic hot water12. Electronic thermostat (10 to 80 °C)

13. Domestic hot water on light

14. Location for hour run meter (Option)

6 DTG 230 27/02/2018 - 300011506-03

Page 7: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

3. Description

3.2.2 DIEMATIC-m3 control panel

Electromechanical components

1. General ON (1) / OFF (0) switch

2. Burner alarm indicator + Reset buttonThis light comes on when the safety control box is in safetylockout (out of order).

3. Switch AUTO/ /TEST-STBAUTO: Automatic control

: Manual controlTEST-STB: Temporary action to test the safety thermostat

4. Safety thermostat with manual resetSet to 110° C

5. Timed circuit breaker (4 A)

6. Pump shutdown switch

7. Boiler thermostat (30 to 90 °C)

8. Boiler thermometer

9. Switch for selecting the number of burner stages(2-stage boilers)

10. Connector USB

14. Boiler heat curve

15. Flap

16. Display

Display

1 Text and numerical display2 Graphic display bar for the programme in circuit A, B or C

3 Light area: Reduced temperature heating period or tank load disabled

4 Dark area: Comfort temperature heating period or tank load enabled

5 Flashing cursor showing the current time

6 Number display (current time, adjusted values, parameters, etc.)

7 Number of the boiler for which the parameters are displayed

8 The arrows flash when setting values can be modified using the + and - keys

9 Circuit operation symbolsOpening the 3-way valve

Closing the 3-way valve

Displayed circuit pump on

A B C Name of the circuit displayed

10Arrows indicating the chosen time programme (P1, P2, P3 or P4) for the circuit displayed, A, B, C, or the activation of the manual summer mode

11 Symbols indicating that the following inputs/outputs are activeDHW load pump on

Summer mode (Automatic / Manual)

Burner on

Operation with modulating burnerNot used

Operation with 2-stage burner

Burner on with 1 stage

Burner on with 2 stages

727/02/2018 - 300011506-03 DTG 230

Page 8: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

3. Description

3.2.3 K3 control panel

1. General ON (1) / OFF (0) switch

2. Burner alarm indicator + Reset buttonThis light comes on when the safety control box is in safetylockout (out of order).

3. Switch AUTO/ /TEST-STBAUTO: This position enables automatic operation of theinstallation in accordance with DIEMATIC-m 3 regulationcontrols.

: The boiler no longer takes orders from the DIEMATIC-m 3regulation into account. The boiler is regulated by the boilerthermostat(s).TEST-STB: Temporary action to test the safety thermostat

4 Operating the appliance

4.1 Commissioning the boiler

Initial commissioning must be done by a qualifiedprofessional.

1. Check the water pressure in the installation. Top up with morewater if necessary.

2. Open the gas valve.

3. Make the settings on the control panel:

B3 control panel:

- Turn the switch TEST-STB/ / to .- Turn the pump shutdown switch to - Set the boiler thermostat to the desired setting.- When preparing domestic hot water: Set the DHW thermostat to

the desired setting. Setting 6 (approx 60) recommended.

DIEMATIC-m3 control panel:

- Turn the AUTO / / TEST STB switch to AUTO.- Turn the pump shutdown switch to - Set the boiler thermostat to maximum (between 7½ and 9).

K3 control panel (Secondary boiler in cascade with aDIEMATIC-m3 boiler):

- Set switch AUTO / / TEST STB to the AUTO position.

4. Turn the burner switch to 2 (2 stage version)

5. Check that the safety thermostat has not triggered. Remove thesafety thermostat hood and press the reset button with ascrewdriver.

6. Set the On/Off switch to 1.

Only for DIEMATIC-m3 control panel:When the boiler is switched on, the tank exchanger is purgedfor one minute if a tank is connected and its temperature islower than 25°C.If disgassing has already taken place, press the MODE key tosuspend disgassing.

Only for DIEMATIC-m3 control panel:On commissioning, it is necessary to select the desiredlanguage with the + and - keys and confirm with the MODE key.

4.2 Changing the settings

4.2.1 B3 control panel

Heating temperature setting: Set the boiler thermostat to thedesired setting.

Setting the domestic hot water temperature: Set the DHWthermostat to the desired setting.

8 DTG 230 27/02/2018 - 300011506-03

Page 9: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

3. Description

4.2.2 DIEMATIC-m3 control panel

Keys accessible when the flap is closed Keys accessible when the flap is open

4.2.3 K3 control panel

Heating temperature setting: Set the boiler thermostat to thedesired setting.

Make all other settings on the master boiler fitted with a DIEMATIC-m3 control panel Press the key.

Adjustment keysMODE Various operating modes can be selected by successively

pressing key MODE:AUTOMATIQUEDAY 7/7: Forced operation at permanent Day temperatureDAY (Until midnight): Forced operation at temporary DaytemperatureNIGHT 7/7: Forced operation at permanent NighttemperatureNIGHT (Until midnight): Forced operation at temporaryNight temperatureDAYS ANTIFREEZ: Antifreeze mode for the number ofdays setHOLIDAY7/7: Permanent antifreeze mode

Restart key for a DHW calorifier loadAUTOMATIQUEDHW: Restarts DHW load until midnightDHW 7/7: DHW load is forced permanentlyAfter a few seconds, the display disappears but the mode isactivated.

Display key for the various counters (number of burner start-ups, number of burner operating hours, etc.)Set temperatures Day (Heating / DHW / Pool)Set temperatures Night (Heating / DHW)Access key to the secondary boilers (Control panel K3) in a cascade

If using only one boiler, this key is inactive.Setting the gradients for circuits A, B and CSetting the parallel offsets DECAL.// DEP.A, DECAL.// DEP.B or DECAL.// DEP.C for the heating curves on circuits A, B or C.If the Day setting for one of the circuits, A, B or C, is above 30°C, you no longer have access parallel offset on this circuit.

+/- Adjustment keys

Adjustment keysEnter (per 1/2 hour) the comfort temperature period or tank load enabled (dark area).Enter (per 1/2 hour) the reduced temperature period or tank load disabled (light area).

STANDARDSimultaneously pressing the 2 keys, and

, resets all of the time programmes.

Return key

Page scrolling

Line scrolling

Scroll of boilers connected

Manual "Summer" shutdown key. The heating is switched off and DHW production is ensured.

Fitter settings access key

DO NOT USE

927/02/2018 - 300011506-03 DTG 230

Page 10: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

3. Description

4.3 Switching off the boiler

Set the On/Off switch to 0.

DIEMATIC-m3 control panelThe panel must always be supplied with 230V voltage:

- to ensure the anti-grip of the heating pump,

- to ensure Titan Active System® operation when a titanium anodeis protecting the DHW tank.

Use the mode:- summer to shut down the heating.- antifreeze to shut down the boiler if you are to be absent.

4.3.1 Precautions to take if there is a danger of frost

Heating circuit:Use a correctly dosed antifreeze to prevent the heating waterfreezing. If this cannot be done, drain the system completely. In allcases, consult the fitter.

Domestic hot water circuit:Drain the domestic water tank and pipes.

4.3.2 Precautions to take in the event of prolonged shutdown (one year or more)

- Close the gas valve- The boiler and the chimney must be swept carefully.

- Close the door of the boiler to prevent the internal circulation of air.

5 Checking and maintenance

Make the following checks at least 1 time a year:- Checking the ignition burner- Safety devices- Water level- Checking burner safety- Checking the safety thermostat- Checking the downdraught thermostat

Carry out the following maintenance at least 1 time a year:- Cleaning main burner and ignition burner- Cleaning of the heating body- Cleaning painted surfaces

10 DTG 230 27/02/2018 - 300011506-03

Page 11: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

6. Troubleshooting

6 Troubleshooting

6.1 Type plate

Before informing the fitter of a fault, make a note of the followinginformation:Type of gas used

Boiler typeManufacturing dateYear (01 = 2001, 02 = 2002, ...)WeekSerial no. of the applianceThis information can be found on the rating plate stuck to thefront plate of the boiler.

6.2 Error messages

6.2.1 B3 control panel

XX-XX

Message Faults Probable causes Action

AL 50 Boiler sensor The sensor circuit has been broken or short circuited.

The installation is stopped.Advise the installer.

AL 52 Domestic hot water sensor The sensor is cutThe installation continues to operate but domestic hot water heating is no longer covered.Advise the installer.

AL td

Titanium anode

The titanium anode is in open circuit or the tank is empty. Production of domestic hot water is stopped. This may be

reactivated for 24 hours by disconnecting and reconnecting the power supply to the boiler.Advise the installer.AL tc

A short circuit has occurred on the titanium anode or connection reversed.

1127/02/2018 - 300011506-03 DTG 230

Page 12: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

6. Troubleshooting

6.2.2 DIEMATIC-m3 control panel

The last ten failures are memorised in the paragraph #DEF.HISTORY

6.2.3 K3 control panel

No error messages displayed. See DIEMATIC-m3 control paneldisplay.

Message Probable causes Action

SHOW REM.CTRL The message SHOW REM.CTRL indicates the presence of an override on a remote control.

To cancel the overrides on all remote controls, press the AUTO key for 5 seconds.

REVISION Boiler service required. Advise the installer.

DISGASWhen connecting voltage, if the hot water tank temperature is below 25 ºC, the boiler carries out a domestic water exchanger purge cycle.

Wait 1 minute.

AUX1.SENS.FAILAUX2.SENS.FAILUNIV.SENS.FAILDHW 2 S. FAIL

The sensor circuit has been broken or short circuited. Advise the installer.

BOILER S.FAIL. The sensor circuit has been broken or short circuited.

If the boiler sensor fails, the burner is controlled by the boiler thermostat and the heating and DHW circuits operate normally.Advise the installer.

OUTSI. S.FAIL. The sensor circuit has been broken or short circuited.

The boiler setting is equal to BOILER MAX. but can be limited by the boiler thermostat to a lower value.- The valve setting is no longer ensured but monitoring the maximum temperature of the circuit after the valve is ensured.- Valves may be manually operated.- Reheating the domestic hot water remains ensured.Advise the installer.

DHW S. FAILURE The sensor circuit has been broken or short circuited.

To ensure domestic hot water production, set the switch AUTO/ /TEST-

STB to .

Advise the installer.OUTL S.A FAIL.OUTL S.B FAIL.OUTL S.C FAIL.

The sensor circuit has been broken or short circuited.

The circuit concerned goes from automatic to manual mode: The pump operates.Advise the installer.

ROOM S.A FAIL.ROOM S.B FAIL.ROOM S.C FAIL.

The sensor circuit has been broken or short circuited.

The circuit concerned operates without any influence from the room sensor.Advise the installer.

SMOKE S.FAIL. The sensor circuit has been broken or short circuited.

This failure has no impact on the operating modes.Advise the installer.

SWIM.A S.FAILSWIM.B S.FAILSWIM.C S.FAIL

The sensor circuit has been broken or short circuited.

Pool reheating is independent of its temperature.Advise the installer.

SOLAR S.FAIL The sensor circuit has been broken or short circuited.

Reheating domestic hot water using the solar panel is no longer ensured.Advise the installer.

ST.TANK S.FAIL The sensor circuit has been broken or short circuited.

The hot water storage tank reheating operation is no longer assured.Advise the installer.

TA-S SHORT-CIR The Titan Active System® is short-circuited.Domestic hot water production is shut down and can be restarted using key

. The tank is no longer protected.

Advise the installer.

TA-S DISCONNEC The Titan Active System® is on an open circuit.Domestic hot water production is shut down and can be restarted using key

. The tank is no longer protected.

Advise the installer.

TA-S FAILURE Internal problem. Switch off the current. Advise the installer.

12 DTG 230 27/02/2018 - 300011506-03

Page 13: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

6. Troubleshooting

6.3 Incidents and solutions

The burner is not working:- Check the boiler thermostat settings.- Shutdown by the safety thermostat due to accidental overheating

Check that the safety thermostat has not triggered. To restart theboiler, reset the safety thermostat. Remove the safety thermostathood and press the reset button with a screwdriver. Carry out thestart-up operations again. Call your fitter.

- Check the circuit breaker

- The safety control box is malfunctioning (Fault indicator lightilluminated)

Press the resetting button of the burner. Call your fitter.

The burner is operating but the radiators are cold:- Bleed the radiators.- Top up the primary circuit with water.

If it is often necessary to top up the installation with water, contactyour fitter.

- Check that the heating pump is operating correctly.- Check the position of the 3 position switch.

B3 control panel: TEST-STB/ / on .DIEMATIC-m3 control panel: AUTO/ /TEST STB on AUTO.K3 control panel: AUTO/ /TEST STB on AUTO

- Check the boiler thermostat settings.

1327/02/2018 - 300011506-03 DTG 230

Page 14: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

7. Technical specifications

7 Technical specifications

(1) At nominal output (Stage 2)(2) Boiler temperature: 80 °C(3) Electrical power of the boiler only with no accessories

Conditions of use:- Max. safety temperature: 110 °C- Max. operating pressure: 6 bar- Thermostat adjustable from 30 to 90°C- Safety thermostat: 110 °C

8 Energy savings

Here are a few tips for saving energy:- Install reflector panels behind the radiators.- Do not cover the radiators. Do not hang curtains in front of the

radiators.- Insulate pipes to prevent thermal losses and condensation.- Do not obstruct aeration grates (even partially). They help to

reduce humidity in the home. The more humid a home, the moreheating it consumes.

- Turn heating off when airing a room (5 minutes a day is sufficient)Avoid deregulating the thermostat. Switch the On/Off switch to Off.

- Do not shut down heating completely if you are absent. Lower thethermostat by 3-4°C.

- Use the sun's heat as much as possible.- Take showers rather than baths. Use a water-saving shower head.

DTG 230-...S 7 8 9 10 11 12 13 14

Useful outputStage 1 kW 27 36 36 45 45 54 54 54Stage 2 kW 54 63 72 81 90 99 108 117

Smoke temperature (1) (2) °C 135 135 135 135 135 135 135 135Minimum output temperature °C 30 30 30 30 30 30 30 30Maximum output temperature °C 90 90 90 90 90 90 90 90

Maximum operating pressure bar (MPa) 6 (0,6) 6 (0,6) 6 (0,6) 6 (0,6) 6 (0,6) 6 (0,6) 6 (0,6) 6 (0,6)

Electrical connection V/Hz 230/50 230/50 230/50 230/50 230/50 230/50 230/50 230/50

Electrical power (1) (3)

B3DIEMATIC-m3K3

W202119

202119

202119

202119

202119

202119

202119

202119

Gas connection inch R1 R1 R1 R1 R1 R1 R1 R1Heating connection inch R1 1/2 R1 1/2 R1 1/2 R1 1/2 R1 1/2 R1 1/2 R1 1/2 R1 1/2Internal diameter flue gas nozzle mm 160/180 180 180 200 200 200 225 225Water content l 29 32.6 36.2 39.8 43.4 47 50.6 54.2Net weight (without water) kg 230 257 283 305 334 357 386 408

14 DTG 230 27/02/2018 - 300011506-03

Page 15: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

7. Technical specifications

WarrantyYou have just purchased one of our appliances and we thank you

for the trust you have placed in our products. Please note that your

appliance will provide good service for a longer period of time if it is

regularly checked and maintained. Your fitter and our customer

support network are at your disposal at all times.

Warranty terms

Starting from the purchase date shown on the original fitter's

invoice, your appliance has a contractual guarantee against any

manufacturing defect.

The length of the guarantee is mentioned in the price catalogue.

The manufacturer is not liable for any improper use of the appliance

or failure to maintain or install the unit correctly (the user shall take

care to ensure that the system is installed by a qualified fitter). In

particular, the manufacturer shall not be held responsible for any

damage, loss or injury caused by installations which do not comply

with the following:

- applicable local laws and regulations

- specific requirements relating to the installation, such as national

and/or local regulations

- the manufacturer's instructions, in particular those relating to the

regular maintenance of the unit

- the rules of the profession

The warranty is limited to the exchange or repair of such parts as

have been recognised to be faulty by our technical department and

does not cover labour, travel and carriage costs. The warranty shall

not apply to the replacement or repair of parts damaged by normal

wear and tear, negligence, repairs by unqualified parties, faulty or

insufficient monitoring and maintenance, faulty power supply or the

use of unsuitable fuel. Sub-assemblies such as motors, pumps,

electric valves etc. are guaranteed only if they have never been

dismantled.

France

The preceding dispositions are not exclusive of benefits for the

purchaser of the legal guarantee as stated in Civil Code articles

1641 to 1648.

Poland

Warranty conditions are included in the warranty card.

Switzerland

The application of the warranty is subject to the terms and

conditions of sale, delivery and warranty of the company marketing

our products.

Belgium

The preceding dispositions about the contractual guarantee are not

exclusive of profit if the need arises for the purchaser in Belgium of

the applicable legal dispositions on hidden defects.

Italy

The duration of our warranty is shown on the certificate delivered with the appliance.

Our liability as manufacturer may not be invoked in respect of incorrect use of the appliance, incorrect or insufficient maintenance thereof, or incorrect installation of the appliance (you must therefore ensure that installation and maintenance operations are carried out respectively by a qualified professional and by an after sales service company).

Russia

The foregoing provisions in no way affect the rights of the

consumer, which are guaranteed by the legislation of the Russian

Federation as regards hidden defects.

The terms and conditions of warranty and the terms and conditions

of application of the warranty are indicated on the warranty form.

The warranty shall not apply as regards the replacement or repair

of wearing parts under normal use. Such parts include

thermocouples, injection nozzles, flame control and ignition

systems, fuses and gaskets.

Turkey

Due to the laws and regulations the product life for this product is

10 years. During that time the producer and/or the distributor has

to provide after sales services and spare parts.

Other countries

The above provisions do not restrict the benefit of the legal laws

regarding hidden defects applicable in the buyer's country.

1527/02/2018 - 300011506-03 DTG 230

Page 16: Gas-fired boilers DTG 230 S - De Dietrich heating … · 3. Description 3.2 Control panel 3.2.1 B3 control panel 1. General ON (1) / OFF (0) switch 2. Burner alarm indicator + Reset

© CopyrightAll technical and technological information contained in these technical instructions, as well as anydrawings and technical descriptions supplied, remain our property and shall not be multipliedwithout our prior consent in writing.Subject to alterations.

27/02/2018

DE DIETRICH THERMIQUE

57, rue de la Gare F- 67580 MERTZWILLER - BP 30

AD

001N

U-A

K

DUEDI S.r.l.

DE DIETRICH SERVICE

BDR Thermea (Czech republic) s.r.o

www.duediclima.it

www.dedietrich.cz

Distributore Ufficiale Esclusivo

De Dietrich-Thermique Italia

www.dedietrich-heiztechnik.com

Freecall 0800 / 201608

Jeseniova 2770/56

130 00 Praha 3

+49 (0)25 72 / 9161-0

+49 (0)25 72 / 9161-102

[email protected]

Via Passatore, 12 - 12010

San Defendente di Cervasca

CUNEO+39 0171 857170

+39 0171 687875

[email protected]

+420 271 001 627

[email protected]

IT

DE DIETRICH THERMIQUE Iberia S.L.U.

www.dedietrich-calefaccion.es

C/Salvador Espriu, 11

08908 L’HOSPITALET de LLOBREGAT+34 935 475 850

[email protected]

ES

CZ

DE DIETRICH THERMIQUE S.A.S

129164, .

8 800 [email protected]

300011544-001-03300021283-001-03300011523-001-03300011525-001-03300011527-001-03300011531-001-03300011504-001-03300011506-001-03