GE 1X03 ENGINEERING PRACTICES LAB (ELECTRICAL)
LIST OF EXPERIMENTS
1. Residential House Wiring Using Switches, Fuse, Indicator Lamp and Energy
Meter
2. Calibration of Ammeter
3. Calibration of Voltmeter
4. Measurement of Power Using Wattmeter
5. Measurement of Power Factor
6. Measurement of Resistance To Earth Of Electrical Equipment
7. Staircase Wiring
8. Tube Light Wiring
9. Study of Electric Iron-Box
pg. 1
RESIDENTIAL HOUSE WIRING USING SWITCHES, FUSE,
INDICATOR LAMP AND ENERGY METER
AIM:-
To make simple residential house wiring using switches, fuse, indicator, filament lamps and energy meter.
APPARATUS REQUIRED:-
1. Wiring Board
2. Connecting Wires
3. Lamps
4. Fuse
5. Indicator
6. Energy meter
THEORY:-
A switch is used to make or break the electric circuit. It must make the contact finely. Under some abnormal conditions it must retain its rigidity and keep its alignment between switch contacts. Different types of switches are as follows.
1. Surface or Tumbler switch
a. Single way switch b. Two way switch
2. Flush Switch
3. Pull or Ceiling switches
4. Rotary snap switches
5. Push button switch
6. Iron- Clad watertight switches
The fuse arrangement is made to break the circuit in the fault or overloaded
conditions. The energy meter is measuring the units (KWhr) consumed by the
various loads.
CIRCUIT DIAGRAM:-
pg. 2
1-Φ Energy meter10 A
M L P
Fuse D C V
230 V 50 HZ P Switch Switch Single phase 1 2AC Supply S Indicator
Lamp Lamp 1 Lamp T 2 S 10 A
N Fuse
PROCEDURE:-
1. Mark the bulb and switch positions.
2. Give the connections as per the circuit diagram.
3. Switch on the supply.
4. Check the lamps are glowing or not in the corresponding switches are
kept in the ON position.
5. Check whether the energy meter responding to the load.
RESULT:-
Thus the simple house wiring by using switches, fuse, indicator, filament lamps and
energy meter was studied.
Viva Questions:
1. What are the different types of house wiring used in non-industrial premises?
2. What are the advantages of non metallic PVC wiring?
3. What are the accessories used for conduit wiring?
4. How the selection of size of the cable is decided?
5. What are the types of lamp holder?
CALIBRATION OF AMMETER
Aim:pg. 3
1. To measure the current in a given circuit by standard ammeter and to calibrate
the nonstandard ammeter by using the standard ammeter.
2. To find the error and percentage error in the given ammeter with respect to the
standard ammeter.
Apparatus required:
1. Single phase autotransformer 1 KVA ()
2. Standard Ammeter (0-10A) MI
3. Nonstandard Ammeter (0-10A) MI
4. Lamp load
Formula used:
1. Error = AS – AN
AN – Nonstandard Ammeter reading
AS – Standard Ammeter reading
2. Error = (AS – AN) X 100/AS
Circuit Diagram:
Tabular Column
S.No
Standard Ammeter
reading (AS)
Nonstandard Ammeter
reading (AN)
Error
(AS -AN)
Percentage Error (AS – AN) X 100/AS
pg. 4
Model Graph:
% Error (in %)
Current Ic (in Amp)
Procedure:
1. Make the connections as per the circuit diagram.
2. The autotransformer is varied to the rated voltage.
3. The readings on the standard and nonstandard ammeter are noted by varying the
lamp load.
4. The readings are tabulated.
Result:
Thus the current in the circuit was measured by the standard ammeter and the non standard ammeter was calibrated.
Viva Questions:
1. State the type of Ammeter
2. How the Ammeter to be connected in a circuit
3. State the purpose of Autotransformer in the circuit
4. State the reasons for error in Ammeter
5. State the precaution to be observed when conducting the experiment.
CALIBRATION OF VOLTMETER
Aim:
1. To measure the voltage in a given circuit by standard voltmeter and to
calibrate the nonstandard voltmeter by using the standard voltmeter.
pg. 5
2. To find the error and percentage error in the given voltmeter with respect to the
standard voltmeter.
Apparatus required:
1. Single phase autotransformer 1 KVA
2. Standard voltmeter (0-300) V MI
3. Nonstandard voltmeter (0-300) V MI
4. Lamp load
Formula used:
1. Error = VS – VN
VN – Nonstandard Voltmeter reading
VS – Standard Voltmeter reading
2. Error = (VS – VN) X 100/VS
Circuit Diagram:
10 A
P
D 230 V 50 HZ P
Single phase S
AC Supply T S V V
(0-300V) MI (0-300V) MI Non – Std Non - Std
N
10 A 1 – Φ, 230V / (0-270) V Auto Transformer
pg. 6
Tabular Column:
S.No
Standard Voltmeterreading (VS)
Nonstandard Voltmeter
reading (VN)
Error(VS -VN)
Percentage Error(VS -VN)X100/VS
Model Graph:
% Error
(In %)
Voltage Vc (in Volts)
Procedure:
1. Make the connections as per the circuit diagram.
2. The autotransformer is varied and the readings on the standard and
nonstandard voltmeter readings are taken.
3. The readings are tabulated and the percentage error is calculated.
Result:
Thus the voltage in the circuit was measured by the standard voltmeter and the non standard voltmeter was calibrated.
Viva Questions
1. State the type of voltmeter
2. How the voltmeter to be connected in a circuit?
3. State the purpose of Autotransformer in the circuit
4. State the reasons for error in voltmeter
5. State the precaution to be observed when conducting the experiment.
pg. 7
MEASUREMENT OF POWER USING WATTMETER
Aim:
To measure the power in the AC circuit with the help of a single-phase wattmeter.
Apparatus required:
1. Single phase autotransformer 1 KVA, (0-300V)
2. Wattmeter 300V, 10A UPF
3. Connecting wires
4. Lamp load
5. Voltmeter (0-300) V MI
6. Ammeter (0-10) A MI
Formula used:
1. Indicated value of power = Measured value X Multiplication factor
Actual power = VI Cos Watts
Where, V-Voltmeter reading
I - Ammeter reading, Assumed power factor Cos Φ = 1
Indicated power-Actual power
2. % Error= ------------------------------------- X 100
Actual Power
Circuit Diagram:
300V, 10A, UPF, Watt Meter (0-10) A MI
10 A M L
P A
D C V
P 230V, 50 HZSingle phase S AC Supply V (0-300V) MI T
S
N 1- Φ, 230V / (0-270) V 10 A Auto TransformerTabulation:
pg. 8
S.No VoltageVolts
Current(Amp)
Wattmeter reading (Watts) ActualPower
(Watts)
%ErrorMeasured
ValueIndicated
value
Model graph:
Current I (in Amp)
% Error (in %)
Procedure:
1. The circuit connections are made as per the circuit diagram.
2. Initially no load is applied
3. The autotransformer is varied to the rated voltage.
4. The values of voltmeter, ammeter and wattmeter on no load condition is noted.
5. By varying the load in steps the corresponding readings of ammeter, voltmeter
and wattmeter are noted.
6. The % Error is calculated.
Result:
Thus the power in the circuit was measured by the wattmeter and the % error was
calculated.
Viva Questions:
1. Mention two types of wattmeter
2. How are current coil terminal of a wattmeter identified
3. How are pressure coil terminal of a wattmeter identified
4. If wattmeter pointer tends to deflect in the reverse direction, what is the action
to be taken.
5. What is meant by Multiplication Factor as applied to wattmeter
6. State precautions to be observed while conducting the experiment
MEASUREMENT OF POWER FACTOR
pg. 9
Aim:
To measure power factor for the load in the given circuit.
Apparatus required:
1. Single phase autotransformer 1 KVA, 230/ (0-270) V
2. Voltmeter (0-300) V, MI
3. Ammeter (0-10) A MI
4. Wattmeter 300V, 10A, UPF
5. Load
6. Connecting wires
Theory:
The numerical value of cosine of the phase angle between the applied voltage and the
current drawn from the supply voltage gives the power.
It is denoted by cos Φ.
For pure resistive circuit power factor value is 1 and for pure inductive or capacitive
circuit’s power factor is 0. For the other combinations the power factor is defined as
lagging or leading i.e whether the resultant current lags or leads the supply voltage.
Circuit Diagram:
(0-10) A MI 300V, 10A, UPF, Watt Meter
10 A M L
P A
C V D230 V 50 PHZ SSingle phase T AC S V (0-300V) MI
N
10 A 1- Φ, 230V / (0-270) V LAMP LOAD
Auto Transformer
Tabular Column:
pg. 10
Multiplication factor =
S.NoVoltage
VoltsCurrent(Amp)
Wattmeter reading (Watts) PowerFactorcos Φ
MeasuredValue
Indicatedvalue
Formula used:
Power measured by wattmeter = VI cos
Actual power =VI
V - Voltmeter reading in volts
I - Ammeter reading in Amps
Power factor cos Φ = P ow e r m ea su r e d b y w a ttm e t e r ( VI cos Φ )
Actual Power (VI)
Procedure:
The circuit connections are made as per the circuit diagram.
The autotransformer is varied to the rated voltage.
The values of voltmeter, ammeter and wattmeter are noted for the various load
conditions
Finally by using the formula the value of power factor is calculated.
Result:
Thus the power factor in the given circuit was measured.
TUBE LIGHT WIRING
Aim:pg. 11
To prepare wiring for a fluorescent tube light with switch control. Tool required:
1. Screw driver2. Hammer3. Cutting Plier4. Line tester
Components required:
1. Switch2. Tube light with fitting3. Joint clips4. Wires5. Screws6. Switch board
FLUORESCENT LAMP WIRING:-
STARTER
230V, 1- Φ
CHOKE P 50Hz, AC N
Working of the Fluorescent tube light
The fluorescent lamp circuit consists of a choke, starter, a fluorescent tube and a frame.
pg. 12
The length of the commonly used fluorescent tube is 100cm and its power rating is
40W and 230V.
The tube is filled with argon and a drop of mercury. When the supply is switched on, the
current heats the filaments and initiates emission of electrons. After one or two seconds,
the starter circuit opens and makes the choke to induce a momentary high voltage surge
across the two filaments. Ionization takes place through argon and produces bright light.
Procedure:
1. Mark the switch and tube light location points and draw lines for wiring on the
wooden board.
2. Place wires along the lines and fix them with the help of clips.
3. Fix the switch and tube light fitting in the marked positions.
4. Complete the wiring as per the wiring diagram
5. Test the working of the tube light by giving electric supply to the circuit.
Result: The wiring for the tube light was completed and tested.
STAIRCASE WIRINGAIM:
To study the working principle of staircase wiring.pg. 13
APPARATUS REQUIRED
S.no Name of the components Range Quantity
1 Lamp 60w 1
2 Two-way Switch 2
3 Screw Driver 1
4 Connecting Wires 1
5 Lamp Holder 1
Circuit Diagram:
Procedure:
pg. 14
1. Mark switch and bulb location points and draw lines for wiring on the wooden
board.
2. Place wires along the lines and fix them with the help of clamps
3. Fix the two-way switches and bulb holder in the marked positions on the
wooden board.
4. Complete the wiring as per the wiring diagram.
5. Test the working of the bulbs by giving electric supply to the circuit.
Result
The staircase wiring is completed and tested.
MEASUREMENT OF RESISTANCE TO EARTH OF ELECTRICAL EQUIPMENT
pg. 15
Aim:
To measure the resistance to earth / insulation resistance of the order of mega ohms.
Theory:
For this experiment we have to use the Megger. Is is an instrument for testing the
insulation resistance of the order of mega ohms.
Principle:
A megger consists of an emf source and a voltmeter. The voltmeter scale is calibrated
in ohms. In measurement, the emf of the self-contained source should be equal that of
the source used in calibration.
The deflection of the moving system depends on the ratio of the currents in the coils
and is independent of the applied voltage. The value of unknown resistance can be
found directly from the scale of the instrument. Figure shows detailed diagram of a
megger. It consists of a hand driven dc generator a emf about 500v.the permanent dc
meter has two moving coils. First one is deflecting coil and another another one is
controlling coil. The deflecting coil is connected to the generator through a resistor R2.
The torque due to the two coils opposes each other. It consists of three terminals E
(earth terminal) and L (line terminal) and G (guard wire terminal).
Operation:
When the terminals are open circuited, no current flows through the deflecting coil. The
pg. 16
torque to the controlling coil moves the pointer to one end of the scale. When the
terminals are short circuited, the torque due to the controlling coil and the pointer is
deflected to the other end of the scale i.e. Zero mark. In between the two extreme
positions the scale is calibrated to indicate the value of unknown resistance directly.
The unknown insulation resistance is the combination of insulation volume resistance
and surface leakage resistance. The guard wire terminal makes the surface leakage
current to bypass the instrument hence only insulation resistance is measured.
Result:
Thus the measured value of the resistance to earth / insulation resistance of the
unknown material is = ----- M
STUDY OF ELECTRIC IRON-BOX
The electric iron is used to iron the clothes. It is of two types (a) ordinary electric iron
(b) Automatic type.
Ordinary Iron:
It has following main parts: Sole plate, heating element, pressure plate,
hood assembly
Sole Plate:
It is made of cast iron and its bottom is nickel plate which is very shining like glass.
The top of the plate has a smooth surface and two has threaded holes.
Heating Element:
The heating element is made from flat nichrome wire wound on a mica sheet. The
bottom and the top of the element is covered with thick mica sheets and are riveted
with the element. The elements are available to different wattages like 450, 750
and 1000 Watt. The element of ordinary iron differs from the element used in
automatic iron in construction and wattage. In ordinary iron 450W or 750W element
is used. Whereas in automatic iron 750W or 1000W element is used.
Pressure Plate:
The pressure plate is made of cast iron. Its shape resembles with the heating
element. Pressure plate sets and presses the element on sole plate with the help of
two machine screws and nuts. It must be tightly fitted. If this plate is kept loose, the
element will fuse quickly. The surface bottom side of the pressure plate must be
smooth like sole plate. Any projected portion in any of the two plate’s pressure plate
and sole plate will fuse the element quickly.
Hood Assembly:
It is used to cover all the above stated parts. It is made of iron sheet with nickel
plating. Terminal box to give connection to the element is also housed in the handle
pg. 17
in many irons and in iron sheet in many other types. For readymade handles are
available in the markets.
Automatic Iron:
In such iron box the extra part than the ordinary iron is the thermostat assembly
which disconnects the supply from the element automatically when the press reaches
its preset heat range. This iron is costlier than the ordinary iron. A dial knob is fitted
outside and on the cover and under the handle. On this dial cotton, rayon, woolen
words are written. By giving rotation the knob is set accordingly. When the iron
temperature increases beyond the preset limit, the thermostat opens a pair of contact
point to interrupt the current flow. Then when the temperature drops below the preset
limit, the thermostat recluses the contact points. Turning of heat control knob place
more or less pressure on a spring. This then determines how far the thermostat must
warm before the contacts open and thus what temperature is required for this action.
The figure shows the wires, iron Connector, plug and an ordinary iron.
Circuit Diagram:
pg. 18