global leader capital safety in fall protection

4
Capital Safety 3833 SALA Way Red Wing, Minnesota 55066-5005 Tel: 651.388.8282 Fax: 651.388.5065 www.capitalsafety.com GLOBAL LEADER IN FALL PROTECTION Capital Safety thanks you for your business and looks forward to providing you with the very best Flexiguard solution(s) for your fall protection requirements. Please carefully review the attached system approval drawings to confirm this is exactly what you have ordered and the system(s) meet your requirements. Each Flexiguard system is custom manufactured per order and cannot be returned. Please contact us if you require any changes or have questions so that they can be addressed prior to the system going to production. We appreciate the opportunity to provide you with the very best in fall protection. Capital Safety 800-328-6146

Upload: others

Post on 21-Feb-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GLOBAL LEADER Capital Safety IN FALL PROTECTION

Capital Safety 3833 SALA Way

Red Wing, Minnesota 55066-5005

Tel: 651.388.8282 Fax: 651.388.5065

www.capitalsafety.com

GLOBAL LEADER IN FALL PROTECTION

Capital Safety thanks you for your business and looks forward to providing you with the very best Flexiguard solution(s) for your fall protection requirements.

Please carefully review the attached system approval drawings to confirm this is exactly what you have ordered and the system(s) meet your requirements.

Each Flexiguard system is custom manufactured per order and cannot be returned.

Please contact us if you require any changes or have questions so that they can be addressed prior to the system going to production.

We appreciate the opportunity to provide you with the very best in fall protection.

Capital Safety

800-328-6146

Page 2: GLOBAL LEADER Capital Safety IN FALL PROTECTION

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES

THIS DRAWING AND THE INFORMATION CONTAINEDHEREIN IS AND SHALL REMAIN THE PROPERTY OFCAPITAL SAFETY, AND CANNOT BE USED ORREPRODUCED WITHOUT PERMISSION. ANY MATERIALAND/OR PART SUBSTITUTIONS AND/OR CHANGESMUST BE AUTHORIZED IN WRITING BY CAPITALSAFETY PRIOR TO USE.

Capital Safety3833 SALA WayRED WING, MN 55066-5005651-388-8282SCALE -------- PROE www.capitalsafety.com

TITLEAPPROVAL DRAWINGINITIALS DATE

DRAWN AS 04/11/14

DO NOT SCALEDRAWING

DRAWING NUMBER REVISION

8530619 ASHEET 1 OF 3

REVISION RECORDDATE REV DESCRIPTION DR

04/11/14 A CREATED DRAWING ASSYSTEM FEATURES FOR SAFRIG DAVIT ARM: - 360 ROTATION CAPABILITY. - INTEGRATED RESCUE CAPABILITY . - RIGID ANCHOR POINT RATED FOR ONE USER. - RETRACTABLE DEVICES AND SHOCK ABSORBERS USED WITH THIS PRODUCT MUST HAVE AN AVERAGE ARRESTING FORCE OF NOT GREATER THAN 900 lb (4 kN) AND MEET ANSI Z359.14 TYPE B OR Z359.13 RESPECTIVELY. REFER TO RETRACTABLE DEVICES OR SHOCK ABSORBERS LABELING TO DETERMINE MAXIMUM ALLOWED USER WEIGHT. - UPRIGHT TUBE OUTFITTED WITH A FOLDABLE ROTATION HANDLE. - DAVIT ARM ROTATION TO BE CONTROLLED USING A ROTATION LOCK AND LIMITING MECHANISM. ROTATION CAN BE LIMITED TO A SET RANGE OR ROTATION CAN BE LOCKED COMPLETELY. - HIGH STRENGTH DURABLE STEEL CONSTRUCTION. - ALL COMPONENTS ARE POWDER COATED SAFETY YELLOW. - ALL HARDWARE IS GRADE 8 ZINC PLATED. - 550 lb. (249 kg) APPROX. OFFSET ASSEMBLY WEIGHT.

FEATURES FOR SAFRIG COUNTERWEIGHT BASE: - 1,152 lb. (523 kg) APPROX. DRY WEIGHT (AS SHIPPED). - 5,000 lb. (2268 kg) APPROX. WEIGHT WHEN FILLED WITH CONCRETE. - HIGH STRENGTH DURABLE STEEL CONSTRUCTION. - DOES NOT REQUIRE ANY VEHICLE COUNTERWEIGHT. - ALL HARDWARE IS GRADE 8 ZINC PLATED. - ALL COMPONENTS ARE POWDER COATED SAFETY YELLOW. - INTEGRATED FORK POCKETS FOR EASY SYSTEM POSITIONING I-SAFE READYTOTAL SYSTEM WEIGHT: APPROX. 5,550 lb. (2517 kg) WITH CONCRETESYSTEM SAFETY FACTOR: 2:1MEETS OR EXCEEDS OSHA REQUIREMENTS

AS DRAWN

AS NOTED

REDRAW AND RESUBMITDATE:

APPROVAL SIGNATURE DRAWINGS APPROVED

THIS DOCUMENT CONTAINS INFORMATION THAT MAY BE PRIVILEDGED OR CONFIDENTIAL AND IS THE PROPERTY OF CAPITAL SAFETY. IT IS INTENDED SOLEY FOR THE PARTIES TO WHOM IT IS ADDRESSED. SUCH PROPRIETARY INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED TO ANY OTHER PARTIES FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN PERMISSION OF CAPITAL SAFETY. IT IS THE END USERS RESPONSIBILITY TO REVIEW, CONFIRM, AND APPROVE THE DESIGN DETAILS CONTAINED HEREIN. ANY DESIGN CHANGES AND/OR ADJUSTMENTS NEEDING TO BE MADE AFTER THE SIGNING OF THIS DOCUMENT MUST IMMEDIATELY BE COMMUNICATED TO CAPITAL SAFETY HOWEVER, ONCE THE SIGNED APPROVAL IS RECEIVED AND FABRICATION HAS COMMENCED, NO DESIGN CHANGES OR ADJUSTMENTS OR RETURNS WILL BE ALLOWED. FINAL LEAD TIME WILL BE ESTABLISHED BASED ON THE RETURNED AND DATED APPROVAL DOCUMENT BACK TO CAPITAL SAFETY.

CONCRETE NOT INCLUDED

VERTICAL MAST

ANCHOR POINT

RESCUE RE-DIRECTIONALPULLEYS

C/W BASE

ROTATION HANDLE

ROTATION LIMITERS

LOCK PIN

RESCUE WINCHMOUNTING BRACKET

Page 3: GLOBAL LEADER Capital Safety IN FALL PROTECTION

4'-6[1372]

BASE LENGTH

20'-11[6376]

OVERALLHEIGHT

20'-0[6096]

ANCHORHEIGHT

5'-9[1753]

ANCHOR OFFSETFROM MAST

3'-9[1143]

ANCHOR CANTILEVERFROM BASE

2'-4 1/8[714]

BASE HEIGHT

4'-6[1372]

BASE WIDTH

3'-6 5/8[1082]

ROTATION HANDLEHEIGHT

4'-11[1498]

WINCHBRACKETHEIGHT

8[203]DAVIT WIDTH

53.25[1353]

OUTER FORKPOCKET SPACER

10.75[273]

FORK POCKETWIDTH

30.25[768]

INNER FORKPOCKET SPACING

3.50[89]FORKPOCKETHEIGHT

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES

THIS DRAWING AND THE INFORMATION CONTAINEDHEREIN IS AND SHALL REMAIN THE PROPERTY OFCAPITAL SAFETY, AND CANNOT BE USED ORREPRODUCED WITHOUT PERMISSION. ANY MATERIALAND/OR PART SUBSTITUTIONS AND/OR CHANGESMUST BE AUTHORIZED IN WRITING BY CAPITALSAFETY PRIOR TO USE.

Capital Safety3833 SALA WayRED WING, MN 55066-5005651-388-8282SCALE -------- PROE www.capitalsafety.com

TITLEAPPROVAL DRAWINGINITIALS DATE

DRAWN AS 04/11/14

DO NOT SCALEDRAWING

DRAWING NUMBER REVISION

8530619 ASHEET 2 OF 3

SEE DETAIL A

DETAIL ASCALE 0.080

FORK POCKET DIMENSIONS

Page 4: GLOBAL LEADER Capital Safety IN FALL PROTECTION

15'-4[4663]

MAX SAFEWORKING RADIUS

30MAX. SAFEWORKING

ANGLE

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES

THIS DRAWING AND THE INFORMATION CONTAINEDHEREIN IS AND SHALL REMAIN THE PROPERTY OFCAPITAL SAFETY, AND CANNOT BE USED ORREPRODUCED WITHOUT PERMISSION. ANY MATERIALAND/OR PART SUBSTITUTIONS AND/OR CHANGESMUST BE AUTHORIZED IN WRITING BY CAPITALSAFETY PRIOR TO USE.

Capital Safety3833 SALA WayRED WING, MN 55066-5005651-388-8282SCALE -------- PROE www.capitalsafety.com

TITLEAPPROVAL DRAWINGINITIALS DATE

DRAWN AS 04/11/14

DO NOT SCALEDRAWING

DRAWING NUMBER REVISION

8530619 ASHEET 3 OF 3

360 DAVIT ROTATION